Lung and chest wall impedances in the dog: effects of frequency and tidal volume.

Dependences of the mechanical properties of the respiratory system on frequency (f) and tidal volume (VT) in the normal ranges of breathing are not clear. We measured, simultaneously and in vivo, resistance and elastance of the total respiratory system (Rrs and Ers), lungs (RL and EL), and chest wall (Rcw and Ecw) of five healthy anesthetized paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz) delivered at a constant mean lung volume. Each dog showed the same f and VT dependences. The Ers and Ecw increased with increasing f to 1 Hz and decreased with increasing VT up to 200 ml. Although EL increased slightly with increasing f, it was independent of VT. The Rcw decreased from 0.2 to 2 Hz at all VT and decreased with increasing VT. Although the RL decreased from 0.2 to 0.6 Hz and was independent of VT, at higher f RL tended to increase with increasing f and VT (i.e., as peak flow increased). Finally, the f and VT dependences of Rrs were similar to those of Rcw below 0.6 Hz but mirrored RL at higher f. These data capture the competing influences of airflow nonlinearities vs. tissue nonlinearities on f and VT dependence of the lung, chest wall, and total respiratory system. More specifically, we conclude that 1) VT dependences in Ers and Rrs below 0.6 Hz are due to nonlinearities in chest wall properties, 2) above 0.6 Hz, the flow dependence of airways resistance dominates RL and Rrs, and 3) lung tissue behavior is linear in the normal range of breathing.

Airway Resistance↗

Lung and chest wall impedances in the dog in normal range of breathing: effects of pulmonary edema.

We evaluated the effect of pulmonary edema on the frequency (f) and tidal volume (VT) dependences of respiratory system mechanical properties in the normal ranges of breathing. We measured resistance and elastance of the lungs (RL and EL) and chest wall of four anesthetized-paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz), delivered at a constant mean airway pressure. Measurements were made before and after severe pulmonary edema was produced by injection of 0.06 ml/kg oleic acid into the right atrium. Chest wall properties were not changed by the injection. Before oleic acid, EL increased slightly with increasing f in each dog but was independent of VT. RL decreased slightly and was independent of VT from 0.2 to 0.4 Hz, but above 0.4 Hz it tended to increase with increasing flow, presumably due to the airway contribution. After oleic acid injection, EL and RL increased greatly. Large negative dependences of EL on VT and of RL on f were also evident, so that EL and RL after oleic acid changed two- and fivefold, respectively, within the ranges of f and VT studied. We conclude that severe pulmonary edema changes lung properties so as to make behavior VT dependent (i.e., nonlinear) and very frequency dependent in the normal range of breathing.

Airway Resistance↗

Respiratory impedance spectral estimation for digitally created random noise.

Measurement of respiratory input mechanical impedance (Zrs) is noninvasive, requires minimal subject cooperation, and contains information related to mechanical lung function. A common approach to measure Zrs is to apply random noise pressure signals at the airway opening, measure the resulting flow variations, and then estimate Zrs using Fast-Fourier Transform (FFT) techniques. The goal of this study was to quantify how several signal processing issues affect the quality of a Zrs spectral estimate when the input pressure sequence is created digitally. Random noise driven pressure and flow time domain data were simulated for three models, which permitted predictions of Zrs characteristics previously reported from 0-4, 4-32, and 4-200 Hz. Then, the quality of the Zrs estimate was evaluated as a function of the number of runs ensemble averaged, windowing, flow signal-to-noise ratio (SNR), and pressure spectral magnitude shape magnitude of P(j omega). For a magnitude of P(j omega) with uniform power distribution and a SNR less than 100, the 0-4 Hz and 4-200 Hz Zrs estimates for 10 runs were poor (minimum coherence gamma 2 less than 0.75) particularly where Zrs is high. When the SNR greater than 200 and 10 runs were averaged, the minimum gamma 2 greater than 0.95. However, when magnitude of P(j omega) was matched to magnitude of Zrs, gamma 2 greater than 0.91 even for 5 runs and a SNR of 20. For data created digitally with equally spaced spectral content, the rectangular window was superior to the Hanning. Finally, coherence alone may not be a reliable measure of Zrs quality because coherence is only an estimate itself. We conclude that an accurate estimate of Zrs is best obtained by matching magnitude of P(j omega) to magnitude of Zin (subject and speaker) and using rectangular windowing.

Airway Resistance↗

Physiological basis for resonant frequencies in respiratory system impedances in dogs.

The lumped six-element model of the respiratory system proposed by DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956) has often been used to analyze respiratory system impedance (Zrs) data. This model predicts a resonance (relative minimum in Zrs) at fr between 6 and 10 Hz and an antiresonance (relative maximum in Zrs) at far at higher frequencies (greater than 64 Hz). The far is due to the lumped tissue inertance (Iti) and the alveolar gas compression compliance (Cg). An fr and far have been recently reported in humans, but the far was shown to be not related to Iti and Cg, but instead it is the first acoustic antiresonance of the airways due to their axial dimensions). Zrs data to frequencies high enough to include the far have not been reported in dogs. In this study, we measured Zrs in dogs for frequencies between 5 and 320 Hz and found an fr at 7.5 +/- 1.6 Hz and two far at 97 +/- 13 and 231 +/- 27 Hz (far,1 and far,2, respectively). When breathing 80% He-20% O2, the fr shifted to 14 +/- 2 Hz, far,1 did not change (98 +/- 9 Hz), and far,2 increased to greater than 320 Hz. The behavior of fr and far,1 is consistent with the structure-function implied by the six-element model. However, the presence of an far,2 is not consistent with this model, because it is the airway acoustic antiresonance not represented in the model. These results indicate that, for frequencies that include the fr and far,1, the six-element model can be used to analyze Zrs data and reliable estimates of the model's parameters can be extracted by fitting the model to the data. However, more complex models must be used to analyze Zrs data that include far,2.

Airway Resistance↗

Moment analysis of a multibreath nitrogen washout based on an alveolar gas dilution number.

A common method for analyzing a multibreath nitrogen washout (MBNW) is to perform moment analysis and derive the mean dilution number (MDN). A homogeneously mixed alveolar space with zero series dead space (VD = 0) will always result in a MDN = 1, regardless of breathing pattern. A higher MDN implies more inhomogeneity. But, if VD greater than 0, the MDN can become sensitive (artificially high) to VD/VT ratios. We present an alveolar-based mean dilution number (AMDN) that uses the cumulative expired alveolar volume. Unlike the MDN, the AMDN for a homogeneously mixed alveolar space is unity, regardless of VD or VT, and hence should be a more appropriate index of inhomogeneity at the alveolar level. Two sets of experiments were used to compare the AMDN with the MDN. First, a MBNW was performed by five healthy subjects at spontaneous VD/VT and at a low VD/VT achieved by a controlled increase in VT. Here, the MDN decreased from 1.98 +/- 0.1 to 1.79 +/- 0.06, whereas the AMDN was essentially unchanged (1.42 +/- 0.04 to 1.38 +/- 0.06). Second, MBNW values from seven healthy subjects, five with cystic fibrosis, and 10 asthmatic subjects (before and after bronchodilation) were analyzed. Compared with the MDN, the AMDN showed a significantly wider separation between clinical groups. Also, the AMDN demonstrated an increased variability within both sick groups versus a decrease in the healthy group. We conclude that the AMDN is superior to the MDN because of its decreased sensitivity to breathing pattern but increased sensitivity to degree of disease.

Adolescent↗

Physiological interpretations based on lumped element models fit to respiratory impedance data: use of forward-inverse modeling.

Respiratory impedance (Zrs) data at lower (less than 4 Hz) and higher (greater than 32 Hz) frequencies require more complicated inverse models than the standard series combination of a respiratory resistance, inertance, and compliance. In this paper, a forward-inverse modeling approach was used to provide insight on how the parameters in these more complicated inverse models reflect the true physiological system. Forward models are set up to incorporate explicit physiological and anatomical detail. Simulated forward data are then fit with identifiable inverse models and the parameter estimates related to the known detail in the forward model. It is shown that inverse fitting of low frequency data alone will not allow a distinction between frequency dependence due to airway inhomogeneities and frequency dependence due to tissue viscoelasticity. With higher frequency data, a forward model based on an asymmetric branching airways network was used to simulate Zrs from 0.1-128 Hz with increasing amounts of nonuniform peripheral airway obstruction. Here, inverse modeling is more amenable to sensibly separating estimates of airway and tissue properties. A key result, however, is that changes in the tissue parameters of an inverse model (which provides an excellent fit to Zrs data) will appropriately occur in response to inhomogeneous alterations in airway diameters only. The apparent altered tissue properties reflect the decreased communication of some tissue segments with the airway opening and not an explicit change at the tissue level. These phenomena present a substantial problem for the inverse modeler. Finally, inverse model fitting of low and high frequency Zrs data simultaneously with a single model is not helpful for extracting additional physiological detail. Instead, separate models should be applied to each frequency range.

Airway Obstruction↗

Effects of tidal volume and methacholine on low-frequency total respiratory impedance in dogs.

The frequency dependence of respiratory impedance (Zrs) from 0.125 to 4 Hz (Hantos et al., J. Appl. Physiol. 60: 123-132, 1986) may reflect inhomogeneous parallel time constants or the inherent viscoelastic properties of the respiratory tissues. However, studies on the lung alone or chest wall alone indicate that their impedance features are also dependent on the tidal volumes (VT) of the forced oscillations. The goals of this study were 1) to identify how total Zrs at lower frequencies measured with random noise (RN) compared with that measure with larger VT, 2) to identify how Zrs measured with RN is affected by bronchoconstriction, and 3) to identify the impact of using linear models for analyzing such data. We measured Zrs in six healthy dogs by use of a RN technique from 0.125 to 4 Hz or with a ventilator from 0.125 to 0.75 Hz with VT from 50 to 250 ml. Then methacholine was administered and the RN was repeated. Two linear models were fit to each separate set of data. Both models assume uniform airways leading to viscoelastic tissues. For healthy dogs, the respiratory resistance (Rrs) decreased with frequency, with most of the decrease occurring from 0.125 to 0.375 Hz. Significant VT dependence of Rrs was seen only at these lower frequencies, with Rrs higher as VT decreased. The respiratory compliance (Crs) was dependent on VT in a similar fashion at all frequencies, with Crs decreasing as VT decreased. Both linear models fit the data well at all VT, but the viscoelastic parameters of each model were very sensitive to VT. After methacholine, the minimum Rrs increased as did the total drop with frequency. Nevertheless the same models fit the data well, and both the airways and tissue parameters were altered after methacholine. We conclude that inferences based only on low-frequency Zrs data are problematic because of the effects of VT on such data (and subsequent linear modeling of it) and the apparent inability of such data to differentiate parallel inhomogeneities from normal viscoelastic properties of the respiratory tissues.

Airway Resistance↗

Respiratory impedance and multibreath N2 washout in healthy, asthmatic, and cystic fibrosis subjects.

We measured forced expiratory volume in 1 s (FEV1), respiratory impedance (Zrs) from 4 to 60 Hz, and a multibreath N2 washout (MBNW) in 6 normal, 10 asthmatic, and 5 cystic fibrosis (CF) subjects. The MBNW were characterized by the mean dilution number (MDN) derived by a moment analysis. The Zrs spectra were characterized by the minimum resistance (Rmin), the drop in resistance (Rdrop) from 4 Hz to Rmin, and the first resonance frequency (Fr1). Measurements were repeated after bronchodilation in three normal and all asthmatic subjects. Before bronchodilation, six of the asthmatic subjects showed close to normal FEV1. The Zrs in the normal subjects showed low Rmin (1.9 +/- 0.7 cmH2O.l-1.s), Rdrop (0.4 +/- 0.4), and Fr1 (10 +/- 2 Hz). Four of the mildly obstructed asthmatic subjects had normal Zrs but elevated MDNs (i.e., abnormal ventilation distribution). The other six asthmatic subjects had significantly elevated Rmin (4.1 +/- 0.8), Rdrop (6.3 +/- 5.8), and Fr1 (34 +/- 0.4 Hz) and elevated MDNs. The CF patients had elevated Zrs features and MDNs. After bronchodilation, no changes in FEV1, MDN, or Zrs occurred in the normal subjects. All asthmatic subjects showed increased FEV1 and decreased MDN, but the Zrs was unaltered in the four asthmatic subjects whose base-line Zrs was normal. For the other six asthmatic subjects, there were large decreases in the Rmin, Rdrop, and Fr1. Finally, there was a poor correlation between the MDN and the Zrs features but high correlation between the Zrs features alone. These results imply that significant nonuniform peripheral airway obstruction can exist such that ventilation distribution is abnormal but Zrs from 4 to 60 Hz is not. Abnormalities in Zrs from 4 to 60 Hz occur only after significant overall obstruction in the peripheral and more central airways. Combining Zrs and the MBNW may permit us to infer whether the disease is predominantly in the lung periphery or in the more central airways.

Adolescent↗

Inability to separate airway from tissue properties by use of human respiratory input impedance.

Respiratory input impedance (Zrs) from 2.5 to 320 Hz displays a high-frequency resonance, the location of which depends on the density of the resident gas in the lungs (J. Appl. Physiol. 67: 2323-2330, 1989). A previously used six-element model has suggested that the resonance is due to alveolar gas compression (Cg) resonating with tissue inertance (Iti). However, the density dependence of the resonance indicates that is associated with the first airway acoustic resonance. The goal of this study was to determine whether unique properties for tissues and airways can be extracted from Zrs data by use of models that incorporate airway acoustic phenomena. We applied several models incorporating airway acoustics to the 2.5- to 320-Hz data from nine healthy adult humans during room air (RA) and 20% He-80% O2 (HeO2) breathing. A model consisting of a single open-ended rigid tube produced a resonance far sharper than that seen in the data. To dampen the resonance features, we used a model of multiple open-ended rigid tubes in parallel. This model fit the data very well for both RA and HeO2 but required fewer and longer tubes with HeO2. Another way to dampen the resonance was to use a single rigid tube terminated with an alveolar-tissue unit. This model also fit the data well, but the alveolar Cg estimates were far smaller than those expected based on the subject's thoracic gas volume. If Cg was fixed based on the thoracic gas volume, a large number of tubes were again required. These results along with additional simulations show that from input Zrs alone one cannot uniquely identify features indigenous to alveolar Cg or to the respiratory tissues.

Acoustics↗

Sensitivity analysis of respiratory parameter uncertainties: impact of criterion function form and constraints.

A sensitivity analysis based on weighted least-squares regression is presented to evaluate alternative methods for fitting lumped-parameter models to respiratory impedance data. The goal is to maintain parameter accuracy simultaneously with practical experiment design. The analysis focuses on predicting parameter uncertainties using a linearized approximation for joint confidence regions. Applications are with four-element parallel and viscoelastic models for 0.125- to 4-Hz data and a six-element model with separate tissue and airway properties for input and transfer impedance data from 2-64 Hz. The criterion function form was evaluated by comparing parameter uncertainties when data are fit as magnitude and phase, dynamic resistance and compliance, or real and imaginary parts of input impedance. The proper choice of weighting can make all three criterion variables comparable. For the six-element model, parameter uncertainties were predicted when both input impedance and transfer impedance are acquired and fit simultaneously. A fit to both data sets from 4 to 64 Hz could reduce parameter estimate uncertainties considerably from those achievable by fitting either alone. For the four-element models, use of an independent, but noisy, measure of static compliance was assessed as a constraint on model parameters. This may allow acceptable parameter uncertainties for a minimum frequency of 0.275-0.375 Hz rather than 0.125 Hz. This reduces data acquisition requirements from a 16- to a 5.33- to 8-s breath holding period. These results are approximations, and the impact of using the linearized approximation for the confidence regions is discussed.

Airway Resistance↗

Human respiratory input impedance from 4 to 200 Hz: physiological and modeling considerations.

Recent studies on respiratory impedance (Zrs) have predicted that at frequencies greater than 64 Hz a second resonance will occur. Furthermore, if one intends to fit a model more complicated than the simple series combination of a resistance, inertance, and compliance to Zrs data, the only way to ensure statistically reliable parameter estimates is to include data surrounding this second resonance. An additional question, however, is whether the resulting parameters are physiologically meaningful. We obtained input impedance data from eight healthy adult humans using discrete frequency forced oscillations from 4 to 200 Hz. Three resonant frequencies were seen: 8 +/- 2, 151 +/- 10, and 182 +/- 16 Hz. A seven-parameter lumped element model provided an excellent fit to the data in all subjects. This model consists of an airway resistance (Raw), which is linearly dependent on frequency, and airway inertance separated from a tissue resistance, inertance, and compliance by a shunt compliance (Cg) thought to represent gas compressibility. Model estimates of Raw and Cg were compared with those suggested by measurement of Raw and thoracic gas volume using a plethysmograph. In all subjects the model Raw and Cg were significantly lower than and not correlated with the corresponding plethysmographic measurement. We hypothesize that the statistically reliable but physiologically inconsistent parameters are a consequence of the distorting influence of airway wall compliance and/or airway quarter-wave resonance. Such factors are not inherent to the seven-parameter model.

Adult↗

Reliability of parameter estimates from models applied to respiratory impedance data.

Many previous studies have fit lumped parameter models to respiratory input (Zin) and transfer (Ztr) impedance data. For frequency ranges higher than 4-32 Hz, a six-element model may be required in which an airway branch (with a resistance and inertance) is separated from a tissue branch (with a resistance, inertance, and compliance) by a shunt compliance. A sensitivity analysis is applied to predict the effects of frequency range on the accuracy of parameter estimates in this model obtained from Zin or Ztr data. Using a parameter set estimated from experimental data between 4 and 64 Hz in dogs, both Zin and Ztr were simulated from 4 to 200 Hz. Impedance sensitivity to each parameter was also calculated over this frequency range. The simulation predicted that for Zin a second resonance occurs near 80 Hz and that the impedance is considerably more sensitive to several of the parameters at frequencies surrounding this resonance than at any other frequencies. Also, unless data is obtained at very high frequencies (where the model is suspect), Zin data provides more accurate estimates than Ztr data. After adding random noise to the simulated Zin data, we attempted to extract the original parameters by using a nonlinear regression applied to three frequency ranges: 4-32, 4-64, and 4-110 Hz. Estimated parameters were substantially incorrect when using only 4- to 32-Hz or 4- to 64-Hz data, but nearly correct when fitting 4- to 110-Hz data. These results indicate that respiratory system parameters can be more accurately extracted from Zin than Ztr, and to make physiological inferences from parameter estimates based on Zin impedance data in dogs, the data must include frequencies surrounding the second resonance.

Airway Resistance↗

Modeling of respiratory system impedances in dogs.

Mechanical impedances between 4 and 64 Hz of the respiratory system in dogs have been reported (A.C. Jackson et al. J. Appl. Physiol. 57: 34-39, 1984) previously by this laboratory. It was observed that resistance (the real part of impedance) decreased slightly with frequency between 4 and 22 Hz then increased considerably with frequency above 22 Hz. In the current study, these impedance data were analyzed using nonlinear regression analysis incorporating several different lumped linear element models. The five-element model of Eyles and Pimmel (IEEE Trans. Biomed. Eng. 28: 313-317, 1981) could only fit data where resistance decreased with frequency. However, when the model was applied to these data the returned parameter estimates were not physiologically realistic. Over the entire frequency range, a significantly improved fit was obtained with the six-element model of DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956), since it could follow the predominate frequency-dependent characteristic that was the increase in resistance. The resulting parameter estimates suggested that the shunt compliance represents alveolar gas compressibility, the central branch represents airways, and the peripheral branch represents lung and chest wall tissues. This six-element model could not fit, with the same set of parameter values, both the frequency-dependent decrease in Rrs and the frequency-dependent increase in resistance. A nine-element model recently proposed by Peslin et al. (J. Appl. Physiol. 39: 523-534, 1975) was capable of fitting both the frequency-dependent decrease and the frequency-dependent increase in resistance. However, the data only between 4 and 64 Hz was not sufficient to consistently determine unique values for all nine parameters.

Airway Resistance↗

Inverse modeling of dog airway and respiratory system impedances.

Mechanical parameters of the respiratory system are often estimated from respiratory impedances using lumped-element inverse models. One such six-element model is composed of an airway branch [with a resistance (Raw) and inertance (Iaw)] separated from a tissue branch [with a resistance (Rt), inertance (It), and compliance (Ct)] by a shunt compliance representing alveolar gas compression (Cg). Even though the airways are known to have frequency-dependent resistance and inertance, these inverse models have been composed of linear frequency-independent elements. In this study we investigated the use of inverse models where the airway branch was represented by a frequency-independent Raw and Iaw, a Raw that is linearly related to frequency and an Iaw that is independent of frequency, and a system of identical parallel tubes the impedance of which was computed from the tube radius and length. These inverse models were used to analyze airway and respiratory impedances between 2 and 1,024 Hz that were predicted from an anatomically detailed forward model. The forward model represented the airways by an asymmetrically branched network with a terminal impedance representative of known Cg, Rt, It, and Ct. For respiratory impedances between 2 and 128 Hz, all models fit the data reasonably well, and reasonably accurate estimates of Cg, Rt, It, and Ct were extracted from these data. For data above 200 Hz, however, only the multiple-tube model accurately fitted respiratory impedances (Zrs). This model fitted the Zrs data best when composed of 27 tubes, each having a radius of 0.148 cm and a length of 16.5 cm.

Animals↗