PubMed HealthSearch

Biomedical subjects

K R Reynolds

Publications and source records attributed to K R Reynolds.

2 recordsLinked to original sources

Bromodeoxyuridine alternating with radiation for advanced uterine cervix cancer: a phase I and drug incorporation study.

PURPOSE: Preclinical studies show a significant increase in the ratio of the radiosensitizer bromodeoxyuridine (BUdR) in tumors versus the intestinal mucosa during the drug elimination period, compared with the ratio during drug infusion. We constructed a phase I study in patients with locally advanced cervix cancer, using alternating cycles of BUdR and radiation therapy (RT). PATIENTS AND METHODS: Eighteen patients with stage IIB to IVA cervix cancer participated. A treatment cycle consisted of a 4-day BUdR infusion followed by a week of pelvic RT, 15 Gy twice daily in 1.5-Gy fractions. After three cycles, additional BUdR was infused, followed by brachytherapy. The fraction of thymidine replaced by BUdR and the fraction of cells incorporating BUdR were determined in rectal mucosa and tumor biopsies at the end of the first BUdR infusion (day 5), at the middle of the first RT week (day 10), and at the time of brachytherapy. RESULTS: Dose-limiting toxicity was observed in one of 16 patients receiving 1,000 mg/m2/d x 4 days and in both patients receiving 1,333 mg/m2/d x 4 days each cycle. After a median follow-up of 39 months, 12 patients (66%) were free of pelvic disease and nine (50%) were alive and disease free. The ratio of tumor to rectum BUdR incorporation averaged 1.5 to 1.8 and did not differ significantly between day 5 and day 10. A trend toward reduced ratio was observed at brachytherapy. Drug-containing cells in rectal biopsies migrated from the crypts to the mucosal surface. CONCLUSION: In this schedule, 1,000 mg/m2/d is the maximum-tolerated dose of BUdR. BUdR incorporation levels in tumors were consistent with clinically significant radiosensitization. The migration of BUdR-containing rectal mucosa cells from the crypts to the surface at the time of RT suggests that this regimen may offer a relative sparing of the mucosa from radiosensitization.

Adenocarcinoma

Customized gynecologic interstitial implants: CT-based planning, dose evaluation, and optimization aided by laparotomy.

PURPOSE: Interstitial perineal implants may be utilized to deliver a high local radiation dose in the treatment of advanced gynecologic malignancies. Lack of knowledge of the precise anatomic relationships between the implant and the target and critical organs may limit efficacy and increase complication risks. Computed tomography (CT)-based planning, dose evaluation, and optimization of customized interstitial implants, aided by laparotomy, have been developed to overcome these limitations. METHODS AND MATERIALS: Twenty patients with locally advanced gynecologic malignancies treated between May 1990 to October 1996 with external irradiation and one or two implants. Interstitial implants were performed when intracavitary brachytherapy was judged to be inadequate or when the response to external radiation and an intracavitary implant was not satisfactory. Customized interstitial implants were planned using preimplantation CT to determine catheter angles and paths that best implanted the target while avoiding pelvic bones and organs. Laparotomy aimed at lysing bowel adhesions, placement of omental carpet, and refining needle placement. Postimplantation CT was used for loading optimization and dose evaluation. RESULTS: Catheter angles 15-25 degrees were found to adequately implant anteriorly laying targets while avoiding pubic bones and bladder. Adhesiolysis of bowel loops from the vaginal apex was required in patients with prior hysterectomy. Small modifications in catheter placements were made during laparotomy in all implants. Postimplantation CTs showed deviations of the catheter positions compared with the planning CTs and were essential in determining target and organ doses and loading optimization. At a median follow-up of 42 months (range: 9-80 months), local control rate is 55% and disease-free survival 40%. Late complications occurred in 2 of 11 of patients without local recurrence. CONCLUSIONS: CT-based planning, loading optimization, and dose evaluation of customized implants improve radiation dose delivery. Laparotomy enhances implant accuracy and safety. Local tumor control rate is still unsatisfactory. It reflects the shortcomings of technical advances alone in poor prognosis tumors like those selected for this series.

Adenocarcinoma