PubMed Health⌕ Search

Biomedical subjects

K R Subramanian

Publications and source records attributed to K R Subramanian.

3 recordsLinked to original sources

Novel neutral network approach to call admission control in high-speed networks.

This paper presents a novel Call Admission Control (CAC) scheme which adopts the neural network approach, namely Minimal Resource Allocation Network (MRAN) and its extended version EMRAN. Though the current focus is on the Call Admission Control (CAC) for Asynchronous Transfer Mode (ATM) networks, the scheme is applicable to most high-speed networks. As there is a need for accurate estimation of the required bandwidth for different services, the proposed scheme can offer a simple design procedure and provide a better control in fulfilling the Quality of Service (QoS) requirements. MRAN and EMRAN are on-line learning algorithms to facilitate efficient admission control in different traffic environments. Simulation results show that the proposed CAC schemes are more efficient than the two conventional CAC approaches, the Peak Bandwidth Allocation scheme and the Cell Loss Ratio (CLR) upperbound formula scheme. The prediction precision and computational time of MRAN and EMRAN algorithms are also investigated. Both MRAN and EMRAN algorithms yield similar performance results, but the EMRAN algorithm has less computational load.

Algorithms↗

Anatomic modeling from unstructured samples using variational implicit surfaces.

We describe the use of variational implicit surfaces (level sets of an embedded generating function modeled using radial basis interpolants) in anatomic modeling. This technique allows the practitioner to employ sparsely and unevenly sampled data to represent complex biological surfaces, including data acquired as a series of non-parallel image slices. The method inherently accommodates interpolation across irregular spans. In addition, shapes with arbitrary topology are easily represented without interpolation or aliasing errors arising from discrete sampling. To demonstrate the medical use of variational implicit surfaces, we present the reconstruction of the inner surfaces of blood vessels from a series of endovascular ultrasound images.

Animals↗

Accurate 3D reconstruction of complex blood vessel geometries from intravascular ultrasound images: in vitro study.

We present a technique that accurately reconstructs complex three dimensional blood vessel geometry from 2D intravascular ultrasound (IVUS) images. Biplane x-ray fluoroscopy is used to image the ultrasound catheter tip at a few key points along its path as the catheter is pulled through the blood vessel. An interpolating spline describes the continuous catheter path. The IVUS images are located orthogonal to the path, resulting in a non-uniform structured scalar volume of echo densities. Isocontour surfaces are used to view the vessel geometry, while transparency and clipping enable interactive exploration of interior structures. The two geometries studied are a bovine artery vascular graft having U-shape and a constriction, and a canine carotid artery having multiple branches and a constriction. Accuracy of the reconstructions is established by comparing the reconstructions to (1) silicone moulds of the vessel interior, (2) biplane x-ray images, and (3) the original echo images. Excellent shape and geometry correspondence was observed in both geometries. Quantitative measurements made at key locations of the 3D reconstructions also were in good agreement with those made in silicone moulds. The proposed technique is easily adoptable in clinical practice, since it uses x-rays with minimal exposure and existing IVUS technology.

Animals↗