PubMed Health⌕ Search

Biomedical subjects

K Riemslagh

Publications and source records attributed to K Riemslagh.

3 recordsLinked to original sources

Computer simulation of intraventricular flow and pressure gradients during diastole.

A two-dimensional axisymmetric computer model is developed for the simulation of the filling flow in the left ventricle (LV). The computed results show that vortices are formed during the acceleration phases of the filling waves. During the deceleration phases these are amplified and convected into the ventricle. The ratio of the maximal blood velocity at the mitral valve (peak E velocity) to the flow wave propagation velocity (WPV) of the filling wave is larger than 1. This hemodynamic behavior is also observed in experiments in vitro (Steen and Steen, 1994, Cardiovasc. Res., 28, pp. 1821-1827) and in measurements in vivo with color M-mode Doppler echocardiography (Stugaard et al., 1994, J. Am. Coll. Cardiol., 24, 663-670). Computed intraventricular pressure profiles are similar to observed profiles in a dog heart (Courtois et al., 1988, Circulation, 78, pp. 661-671). The long-term goal of the computer model is to study the predictive value of noninvasive parameters (e.g., velocities measured with Doppler echocardiography) on invasive parameters (e.g., pressures, stiffness of cardiac wall, time constant of relaxation). Here, we show that higher LV stiffness results in a smaller WPV for a given peak E velocity. This result may indicate an inverse relationship between WPV and LV stiffness, suggesting that WPV may be an important noninvasive index to assess LV diastolic stiffness, LV diastolic pressure and thus atrial pressure (preload).

Blood Flow Velocity↗

Left-ventricular pressure gradients: a computer-model simulation.

Both invasive left-ventricular pressure measurements and non-invasive colour M-mode echographic measurements have shown the existence of intraventricular pressure gradients (IVPGs) during early filling. The mechanisms responsible for these IVPG cannot be completely explained by the experiments. Therefore a one-dimensional numerical model is developed and validated. The model describes filling (both velocities and pressures) along a left ventricular (LV) base-apex axis. Blood-wall interaction in the left ventricle with moving boundaries is taken into account. The computational results for a canine heart indicate that the observed IVPGs during filling are the consequence of a complex interaction between, on the one hand, pressure waves travelling in the LV and, on the other hand, LV geometry, relaxation and compliance. The computational results indicate the pressure dependency of wavespeed (0.77-1.90 m-1 s) for different mean intraventricular pressures (0.88-5.00 mmHg) and IVPGs up to 2 mmHg, independent of the ratio of end systolic volume and equilibrium volume. Increasing relaxation rate not only decreases minimum basal pressure (2.8 instead of 3.6 mmHg) but also has a strong influence on the time delay between the minimum basal and apical pressures (14 ms instead of 49 ms). The results sustain the hypothesis that pressure-wave propagation determines IVPGs and that IVPGs are no proof of elastic recoil.

Blood Pressure↗

A three-dimensional analysis of flow in the pivot regions of an ATS bileaflet valve.

Bileaflet heart valves are currently the most commonly implanted type of mechanical prosthetic valve, because of their low transvalvular pressure drop, centralised flow and durability. However, in common with all mechanical heart valves, implanted bileaflet valves show an inherent tendency for blood clot formation at the valve site. Fluid dynamical phenomena associated with blood clotting are elevated blood shear stresses and regions of persistent blood recirculation, particularly when both occur together. Using three-dimensional CFD modelling, combined with enlarged scale experimental modelling, we investigated the blood flow through the ATS bileaflet valve during forward flow, with particular attention to the leaflet pivot regions. Recirculating regions were found both within and downstream of the valve housing ring. Qualitative assessment of the entire cardiac cycle suggested that recirculating blood within the housing ring will be washed away whilst the valve is closed, but as with all bileaflet valve designs recirculating blood downstream of the valve may have a residence time much longer than one cardiac cycle.

Blood Flow Velocity↗