K Ruffieux

Publications and source records attributed to K Ruffieux.

6 recordsLinked to original sources

Resorbable defect analog PLGA scaffolds using CO2 as solvent: structural characterization.

After tooth extraction, the immediate wound treatment by implanting an exact copy of the root could prevent alveolar bone atrophy. The implant should have an interconnected porosity in order to promote tissue in-growth. This communication reports a novel method to realize such net-shaped porous scaffolds fabricated within a few minutes. Porosity and micro-architecture are evaluated by Hg-porosimetry and by image analysis of electron and light microscopy as well as by computed micro-tomography. The total porosity of the scaffold corresponds to (63 +/- 3)%, mainly related to open interconnected porosity. Micro-tomography, as a noninvasive 3D method, is best suited to uncover pores of about 100 microm, a diameter especially important for tissue in-growth. The differentiation between open and closed porosity, however, depends on the method chosen. This effect is attributed to the spherical pores with an orifice only detected in the 3D analysis. Consequently, the closed porosity is overestimated by 8% evaluating 2D images. Finally, the mean pore diameter is found to be 106 and 100 microm for 2D and 3D analysis, respectively. Although the porosity of the scaffold needs to be further optimized for clinical applications, the procedure proposed is a promising route in manufacturing open porous implants without the use of any organic solvent.

Alveolar Bone Loss↗

Degradation of poly(D,L)lactide implants with or without addition of calciumphosphates in vivo.

The study was aimed at examining the in vivo degradation of pure poly(D,L)lactide (PDLLA) or PDLLA with an admixture of calciumphosphates. One rod (20 x 3 x 2 mm) and one cube (3 x 2 x 2 mm) of pure PDLLA, PDLLA with tricalciumphosphate (PDLLA + TCP) or PDLLA with calciumhydrogenphosphate (PDLLA + CHP), respectively, were implanted into the dorsal muscles of 50 male Wistar Albino rats. After definite intervals (from 2nd to 72nd week), pH measurements were performed in the environment of the implants. Afterwards, the cubes with their surrounding tissues were excised for histological examinations, measurements of the outer dimensions and mechanical analyses of the explanted rods were performed. No drop of more than 0.1 pH units was detectable in the tissue surrounding any type of implants. No advantageous effect of the calciumphosphates could be proved. A mild foreign body reaction could be observed around PDLLA implants. After 72 weeks, pure PDLLA had been totally resorbed from the extracellular space, the degradation of calciumphosphate-enriched PDLLA was still in progress. A large amount of inflammations occurred in the tissues surrounding PDLLA with an admixture of slowly degrading TCP or CHP, leading to two abscesses and four fistulas at PDLLA + TCP, and two abscesses and three fistulas at PDLLA + CHP implantation site. Bending strength of pure PDLLA was constant up to the 4th week post-implantation and reduced to 60% of the initial value up to the 12th week. No traces of crystallinity could be observed during the degradation of PDLLA. As a conclusion of the study, complete resorption from the extracellular space and tissue tolerance of pure PDLLA is proved. An admixture of small calciumphosphate particles is not suitable to improve the biocompatibility of PDLLA but leads to a decrease in the mechanical characteristics.

Animals↗

The effect of an addition of sodium hydrogenphosphate to poly(D,L)lactide--results of in vitro examinations.

Aim of the study was to examine the influence of sodium hydrogenphosphate (NaP) on the pH value and the mechanical characteristics of degrading poly(D,L)lactide (PDLLA). Test rods of PDLLA with or without NaP amounting to 1, 10, 25 or 50 mol per 100 mol lactate, the degradation product of PDLLA, were produced by injection molding. Molecular weight and bending strength of the rods were measured before and after an accelerated in vitro-test (55 degrees C, Ringer's solution (RS)). For a long-time degradation test PDLLA-rods with or without 1 mol% NaP were placed in RS or Soerensen buffer solution (SB, pH 7.4) at 37 +/- 1 degrees C. Measurements of pH and determination of length, volume and weight of the samples were done in 2-4 week intervals up to the 52nd week after incubation. A pH-drop was measured in RS or SB containing pure PDLLA after 28 or 36 weeks respectively. Stabilization of the pH value due to admixed NaP delayed the degradation related pH drop for 8 weeks in RS or SB. A strong increase of length, volume and weight was measured in PDLLA + NaP-rods. In conclusion minimal stabilization of pH but also an increase of outer dimensions of the samples was found due to the admixture of NaP to PDLLA. Thus, an addition of substantially higher amounts than 1 mol% NaP in PDLLA can not be recommended, regardless of the positive effects on pH stabilization.

Absorbable Implants↗

[Biomaterials, human tolerance and integration].

Biomaterials and related process engineering in order to obtain optimal surface and structural biocompatibility of implants and devices are presented. Vital-avital composites for tissue engineering, cell culture models, porous ceramics and degradable polymers are introduced as examples. Emphasis is laid on the conversion of basic research results into clinical applications and on the exchange of technologies from the non-medical into the medical field and vice versa.

Animals↗

Autosterilization of biodegradable implants by injection molding process.

Sterilization of degradable implants by standard procedures may damage the parts due to the labile chemical nature of the polymers. This study examined whether the injection molding process used for the production of polymeric parts may itself sterilize the implant due to high temperature, pressure, and shear forces applied. Poly-D,L-lactic acid (PDLLA) and poly-L-lactic acid (PLLA) granules were contaminated with thermoresistant spores of Bacillus stearothermophilus (>10(5) spores/g). Sterile and contaminated granules of both polymers were injection molded and tested for sterility. All 27 samples produced with sterile PDLLA and processed at 120 degrees C and all 18 samples produced with sterile PLLA at 200 degrees C remained sterile after injection molding and handling. However, in five out of 28 PDLLA samples and in one out of 26 PLLA samples produced with contaminated material, spores had survived the process. In conclusion, the injection molding process could not reliably sterilize parts produced with polylactic acid granules that were heavily contaminated with thermoresistant organisms. However, the number of viable spores was significantly reduced by more than 99.99%. Thus, the injection molding process might allow the autosterilization of parts produced with raw material that is not heavily contaminated.

Biocompatible Materials↗