Teleradiology for consultation between practitioners and radiologists.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to K S Berbaum.
Explore the source record for details and available documents.
RATIONALE AND OBJECTIVES: The purpose of this study is to compare the diagnostic accuracy of interpreting clinical neonatal radiographs using a commercially available digital workstation versus conventional radiographic images. METHODS: The case sample consists of 100 chest or abdominal radiographs from the neonatal intensive care unit in which diagnosis was confirmed. Four radiologists served as observers. During two initial reading sessions, half of the studies were viewed on digital radiography monitors and the other half by plain film. Observers indicated whether each patient had normal or abnormal findings and their degree of confidence in this judgment. Six weeks later, observers viewed cases on the alternate presentation system. Two statistical analyses were performed: the data from each observer were treated as a separate experiment in the first analysis; the data from all observers were combined using a new method in the second analysis. RESULTS: No differences between areas under receiver operating characteristic (ROC) curves for viewing on the picture archiving and communication system (PACS) console and plain film were found for any observer (0.86 versus 0.86, 0.89 versus 0.86, 0.88 versus 0.85, 0.83 versus 0.82). CONCLUSIONS: The study suggests that for pediatric plain film images, video images offer diagnostic information comparable with that of conventional radiographs for neonatal examinations.
The authors review and classify errors in 182 cases that were presented at problem case conferences between August 1986 and October 1990. Errors were classified by means of a system developed 20 years ago and by means of a system developed within the past several years. The authors found that sources of error have changed very little. Errors usually involved failure to consult old radiologic studies or reports, limitations in imaging technique, acquisition of inaccurate or incomplete clinical history, location of a lesion outside the area of interest on an image, lack of knowledge, failure to continue to search for abnormalities after the first abnormality was found, and failure to recognize a normal biologic variant. Errors included 126 perceptual errors (64 false-negative, 15 false-positive, and 47 misclassification errors) and 56 mishaps, including 38 complications and 18 communication errors. In seven cases nonperception errors occurred because established departmental routines were not followed, and in nine cases a new departmental routine was established after a complication occurred. Departmental policy exerts less effect on perception and interpretation errors.
A three-dimensional system for dosimetric calculation of radiation from interstitial brachytherapeutic implants was developed and was compared with conventional dosimetry performed with a commercial two-dimensional system. Software programs written for this study enabled the authors to place radioactive sources in the correct reconstructed anatomic locations, compute the isodose distribution around these sources, and display the isodose curves in their correct relationship to anatomic structures. Eight radiation oncologists evaluated the usefulness of both systems. Verification studies in phantoms and in 20 patients with gold-198 implants in the prostate gland showed that the experimental system was very accurate in volume reconstruction, seed localization, isodose distribution, point-dose calculation, and computation of dose-volume histograms. Although the dose depictions in the two systems matched almost exactly, statistically significant differences existed in interpretation of the dosimetric data generated by both systems. For example, the oncologists consistently believed that the dose to the prostate was lower when the three-dimensional system was used (P less than or equal to .0001).
To identify magnetic resonance (MR) imaging characteristics of normal patellar tendons and those affected by tendinitis, the authors evaluated MR images obtained in 10 healthy volunteers, in 50 patients who underwent MR imaging for evaluation of knee structures other than the patellar tendon, in 11 patients with patellar tendinitis, and in two athletes with patellar tendon injuries. Normal tendons had uniformly low signal intensity on T1-, T2-, and proton-density-weighted images and displayed distinct margins, and the anteroposterior (AP) diameter slightly increased proximally to distally. It was concluded that the AP diameter of a normal tendon, in its proximal portion, should not exceed 7 mm. In patellar tendinitis, the tendon showed increased signal intensity on T1-, T2-, and proton-density-weighted images and increased AP diameter proximally. The margins of affected tendons were indistinct, especially posterior to the thickened segment. In all groups studied, women had thicker proximal tendons than did men.
We prospectively compared current digital subtraction angiography (DSA) with conventional film-screen angiography (FSA) of the lower limb for evaluation of areas of arterial stenosis and degree of arterial visualization. Fifty patients had both DSA and FSA of a single lower limb. Specific anatomic sites (examiner-selected sites) throughout the lower limb were marked on each film by an experienced angiographer (examiner). These sites consisted of the common femoral, superficial femoral, popliteal, anterior tibial, posterior tibial, peroneal, and dorsalis pedis arteries and bypass grafts, when present. The films were then reviewed blindly by two different experienced angiographers (observers). All sites were graded for the degree of arterial narrowing based on a standard scale (grade 1 = normal, grade 5 = occluded) that also included grading for nonvisualization (grade 6). Each observer also selected the most stenotic site in each anatomic area (observer-selected sites). The data were analyzed for the entire lower limb and at specific anatomic sites. DSA sites were judged to be slightly more narrowed (p less than .05) in the superficial femoral artery by both observers and in the common femoral artery, bypass graft, and overall by a single observer. No other significant differences were found in grade of stenosis or vessel visualization for examiner-selected sites. For observer-selected sites, observers agreed on the location of the most stenotic site 76% of the time for FSA and 69% of the time for DSA. No significant difference was found in grade of stenosis or vessel visualization for either observer for the entire lower limb or at specific anatomic sites. These findings were present when all sites chosen were considered and when there was agreement between sites chosen on FSA and DSA for each observer. In conclusion, optimal-quality FSA and DSA produced virtually equivalent results for angiography of the lower limb for both grade of stenosis/occlusion and vessel visualization.
Explore the source record for details and available documents.
This research assessed the usefulness of the Motion History Questionnaire (MHQ) for the prediction of simulator sickness, a form of motion sickness experienced by pilots training in ground-based flight simulators. Four MHQ scoring keys were compared: (1) the original MHQ key which had been validated on a sample of U.S. Navy student pilots exposed to Coriolis forces, (2 and 3) two keys which had been validated on a sample of civilian college students exposed to simulated ship motions, and (4) a simulator sickness key empirically derived in the present research and cross-validated. Navy and Marine Corps aviators (N = 456) filled out the MHQ prior to their regularly scheduled flight simulator training and were divided into validation and cross-validation samples. All scoring keys were predictive of reported symptoms of sickness, but highest correlations were obtained with the empirically-derived simulator sickness (SS) key. It is suggested that the SS key be used for self-testing so that pilots may be made aware of their risk for developing simulator sickness.
The CT findings in 32 patients with pathologically proven metastases to the kidney were compared to findings in 74 patients with renal cell carcinoma. Fourteen CT criteria were chosen to describe and characterize the lesions and 2 radiologists evaluated the CT images retrospectively according to these criteria. Renal metastases were characterized as small, multiple, bilateral, wedge-shaped, less exophytic, and located within the renal capsule. Renal cell carcinomas were single, unilateral, nonwedge-shaped, and exophytic, and easily transgressed the renal capsule. The sensitivity of CT to discriminate renal cell carcinoma from renal metastasis was 93.2% for renal cell carcinoma, and to discriminate renal metastasis from renal cell carcinoma was 75.0% for renal metastases by computer posterior probabilities. This study indicates that CT is useful for distinguishing these clinically important tumors. By using posterior probability, some unnecessary biopsies may be avoided.
The diagnostic value of neonatal examinations using picture archiving and communication systems (PACS) was compared with that of conventional radiographs. A total of 202 consecutive chest or abdominal radiographs from the newborn intensive care unit were digitized for display on a commercially available PACS console. Experimental design was a paired comparison study. Plain films and PACS images were reviewed alternately in unbiased fashion. After the examination was evaluated using the second modality, any change in diagnosis or confidence in diagnosis was noted. Overall evaluation showed slight preference for the PACS modality. Change of diagnosis or in confidence of diagnosis was more than twice as likely to occur with evaluation of PACS (35%) after hardcopy than with evaluation of conventional radiographs (14%) after PACS. Of the variety of image processing features available on PACS, only window and leveling were judged to be of significant value. These results indicate that PACS and conventional radiographs of the neonatal chest and abdomen are of similar diagnostic value.
The authors studied the effect of catheter size on the development of hematomas after catheterization. Four hundred ninety-nine patients who underwent routine diagnostic angiography were randomized to receive either 5-F or 7-F catheters. Small hematomas were more frequent in the 7-F catheter group (P less than .05); however, there was no difference in the frequency of larger hematomas between groups. Compression time was slightly but significantly (P less than .001) longer in the 7-F group. When catheter size; duration of the procedure; and patient age, weight, blood pressure and coagulation status were considered as independent variables, patient weight was the most accurate predictor of hematoma formation. The authors conclude that catheter size does not affect the development of a clinically significant hematoma after diagnostic angiography and that other factors such as patient weight are more important in this regard.
Explore the source record for details and available documents.
"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discovery of lesions. Detection accuracy of native lesions in chest radiographs, before and after the addition of a simulated nodular lesion, was measured for ten observers. Analysis of data from this and a previous experiment showed that average perceptual accuracy of individual receiver operating characteristic curves was significantly reduced with the addition of the nodules. Plots and analyses of search time revealed that, on average, during a typical 46-second inspection of a case, simulated nodules were found at 18 seconds, native abnormalities at 25 seconds, and false positives occurred at 33 seconds. Time needed to find nodules did not depend on whether native lesions were present; time to find native lesions did not change with addition of nodules; and total search time was the same for images with one, two, or no lesions. The detection results show that the SOS effect was obtained, but that interrupting search in order to measure it also diminishes accuracy. Analysis of the time course data relates SOS to perceptual capture and strategic halting of search.
Explore the source record for details and available documents.
The effects of two urokinase (UK) dose regimens on lysis time, lytic success, primary clinical success, and frequency of complications of peripheral thrombolysis were compared. Seventy-two intraarterial UK infusions were performed by means of standard catheter-directed infusion techniques in 63 patients with symptomatic peripheral arterial or bypass graft occlusions. Patients were prospectively randomized to high-dose (250,000 U/h for 4 hours and then 125,000 U/h) or low-dose (50,000 U/h) regimens. The mean time to complete lysis was 20.8, 26.0, 16.5, and 18.2 hours for the high-dose artery, low-dose artery, high-dose graft, and low-dose graft groups, respectively (P was not significant). Respective mean infusion durations were 27.1, 35.4, 22.2, and 25.3 hours. Clinical success was achieved in 65%-85% of cases. The frequency of complications was equivalent between groups, except for a higher frequency of minor bleeding complications in the high-dose group. The two urokinase dose regimens studied were equally effective in enabling peripheral thrombolysis.
Fifty-three magnetic resonance imaging (MRI) and 25 computed tomography (CT) studies of 53 head and neck masses in pediatric patients were reviewed retrospectively. All lesions had pathologic proof except for 2 metastatic and 2 recurrent lesions, which only had prior pathologic confirmation at their primary sites. These included 12 malignant tumors, 23 benign tumors, 6 inflammatory masses, and 12 congenital lesions. The MRI performance ranged predominantly from good to excellent in detection of the lesion and the extent of involvement and in contrast to the surrounding tissue; when CT comparison was available, MRI proved to be equal to or better than it in detection of these factors and in preoperative diagnosis. Our results suggest that MRI should be the method of choice for the initial evaluation of the pediatric head and neck region, especially in those patients requiring multiple examinations. However, CT and MRI should be used conjunctively in complicated cases, especially those possibly involving lesions with calcifications or bony involvement.
Picture archiving and communications systems (PACS) have emerged as an important part of digital imaging technology. However, the future of PACS is uncertain because its economic viability is in doubt. Cost-effectiveness analysis is an accepted technique for evaluating the economics of new technologies. This paper addresses the cost-effectiveness of PACS and identifies factors that are important in determining the cost of PACS relative to film-based radiology. These include the impact of PACS on physician productivity, maintenance costs, discount rates, and the time period for amortization of capital goods. The effectiveness of PACS is also explored in terms of improvements in diagnostic accuracy and timely diagnosis. Financial and clinical impacts should be integrated to provide information about how PACS expenditures will affect radiology departments, hospitals, and national research and development objectives.
Safety and efficacy of two drug regimens used for sedation and analgesia during lower-extremity angiography were studied. Midazolam (loading dose 14.5 micrograms/kg; maintenance dose, 7.2 micrograms/kg) with or without fentanyl (loading dose, 0.725 micrograms/kg; maintenance dose, 0.362 micrograms/kg) was administered in a blind fashion as an IV bolus to 50 patients. Hemodynamic responses were monitored, and a standardized questionnaire was given to the patient before, immediately after, and 8-24 hr after the procedure. Physicians also were asked questions after the procedure. Heart rate and oxygen saturation were not significantly different before and 2 min after administration or between groups. A small but significant decrease in blood pressure occurred 2 min after the loading dose was given in both groups. Both drug regimens had statistically significant anxiolytic effects; however, anxiolytic effects were superior in the midazolam/fentanyl group (p less than .02). Patients rated the overall effectiveness of anesthesia with midazolam/fentanyl as superior (p less than .02). Analysis of physicians' judgments of the effectiveness of sedation and analgesia showed a statistically significant advantage for the midazolam/fentanyl group (p less than .01). We conclude that midazolam/fentanyl appears to be as safe as and more efficacious than midazolam alone for sedation and analgesia during lower-extremity angiography.