PubMed Health⌕ Search

Biomedical subjects

K S Sass

Publications and source records attributed to K S Sass.

3 recordsLinked to original sources

Radiotracer binding to brain microsomes determined by thin-layer chromatography.

A thin-layer chromatography (TLC) assay was developed to monitor the interaction of radiotracers with brain microsomes. Murine brain microsomes were coated onto a zone of a TLC strip, the unreacted sites blocked with gelatin, and the radiotracers chromatographed over the microsomes. Radiotracers bound to the microsomes and were separated from the unreacted materials which migrated at or near the solvent front. Up to 80% of the applied radioactivity bound to the brain microsomes when using 99mTc-(d,l) hexamethyl-propyleneamine oxime (HMPAO) and 123I-(S)-2-hydroxy-3-iodo-6-methoxy-N-[(1-ethyl-2-pyrrolidinyl) methyl]-benzamide (123I-IBZM) as tracers. On the other hand, the presumptive negative control materials p-I-15-phenyl-pentadecanoic acid-123I (123I-IPPA) and 99mTc-mercapto-acetyl triglycine (MAG3) bound poorly (7% and 4%, respectively). 99mTc-ethyl cysteinate dimer (ECD) interacted poorly (9.9%), a result thought to be consistent with its known inability to be metabolized by nonprimate brain tissue. Radiolabeled octreotide analogues (radiolabeled with 111In, I-131 or 99mTc) also bound, and the binding could be reduced by excess unlabeled octreotide. Also, chemical modification by acylation of Lys5 in 111In-labeled octreotide led to decreased binding (approximately 70%) compared to the original radiotracer. Chromatography of the various radiotracers over TLC strips coated only with gelatin was used to monitor nonspecific binding and was low and frequently below 5%. This technique does not require wash steps or centrifugation, and assays are rapidly completed. The assay could be useful in monitoring the interaction of radiotracers with brain microsomes and in evaluating and developing new radiotracers.

Animals↗

Anti-colon/ovarian tumor antigen: localization of colon cancer xenografts in athymic rats.

Tumor localization studies in athymic rats bearing human colon tumors were performed using the radioiodinated monoclonal antibody SP-21 and its F(ab')2. Antibody preparations isolated from ascitic fluid and antibody from bioreactor effluent were used in these studies with similar radioimmunolocalization results. The intact antibody had an optimal localization time of 4-8 days after injection, while the F(ab')2 fragments had an optimal localization time of 3-4 days. Whole-body autoradiography, whole-body immunohistochemistry, and scintigraphy confirmed that the intact antibody and the antibody fragments localized preferentially in the tumor. The antibody distribution within the tumor was uniform, and not confined to the periphery, nor to focal areas within the tumor. Dose-response studies were performed with the intact antibody over a range of 10-100 micrograms/kg of total body weight with no clear-cut relationships observed. Comparisons of different radio-iodination methods indicated that the chloramine-T-based methods resulted in preparations with higher tumor uptake.

Animals↗

A comparison of monoclonal antibodies against distinct colon tumor-associated antigens in immunohistochemistry and in tumor localization.

Monoclonal antibodies to colon/ovary tumor antigen (COTA), carcinoembryonic antigen (CEA), colon-specific antigen (CSA), and colon-specific antigen "protein" (CSAp) were evaluated for specificity, reactivity with normal tissues, and tumor localizations using athymic rats bearing xenografted human colon tumors. Radioiodine labeled anti-CSA and anti-COTA retained immunoreactivity and effectively localized the tumors; anti-CSAp retained immunoreactivity, but localized less effectively; and anti-CEA lost most of its immunoreactivity and localized poorly. Of the antibodies tested, anti-COTA showed potential for human colorectal tumor radiolocalization.

Animals↗