PubMed Health⌕ Search

Biomedical subjects

K Sairyo

Publications and source records attributed to K Sairyo.

At least 19 recordsLinked to original sources

Preservation of C7 spinous process does not influence the long-term outcome after laminoplasty for cervical spondylotic myelopathy.

Axial pain is one of the major complications after laminoplasty, and preservation of C7 spinous process during the procedure can reduce the axial pain. However, it has not been elucidated whether laminoplasty preserving the C7 spinous process can maintain neurological improvement for a long time. The purpose of our retrospective study was to investigate the long-term neurological outcome after open-door laminoplasty preserving the C7 spinous process for cervical spondylotic myelopathy (CSM). Clinical and radiological outcomes were analysed in 42 patients who underwent open-door laminoplasty preserving C7 spinous process and followed up for more than 5 years. Neurological function was evaluated by means of the Japanese Orthopaedic Association (JOA) scoring system for cervical myelopathy. Axial pain was assessed using a visual analog scale (VAS) at the last examination. Alignment and motion of the cervical spine were measured from radiographs, and magnetic resonance imaging (MRI) was used to evaluate postoperative compression at C7. The mean JOA score was 9.4 before surgery and 12.0 at the latest follow-up. The mean VAS score in 26 patients score was 9.7/100. No compression of the spinal cord was observed in any MRI at the latest follow-up. Preservation of the C7 spinous process does not influence the long-term outcome of CSM after laminoplasty. Although we did not have a comparative group, the procedure described here should be considered as the solution.

Adult↗

Adult onset tethered cord syndrome associated with intradural dermoid cyst. A case report.

STUDY DESIGN: A case report and a review of literature. OBJECTIVES: To describe a rare case of adult onset tethered cord syndrome associated with intradural dermoid cyst. SETTING: General Orthopedics, Japan. METHODS: A 50-year-old woman was referred to us because of right leg pain and pollakiuria. Neurological examinations and radiological assessments including myelography, computerized tomography scan and Magnetic resonance image were carried out. We diagnosed it as the adult onset tethered cord syndrome associated with an intradural cystic lesion. RESULTS: The cystic lesion was totally removed following laminectomy from L5 through S4. Histologically, the tumor was diagnosed as a dermoid cyst. CONCLUSIONS: Intradural dermoid could produce adult onset tethered cord syndrome, but it was not reported in the English literatures to our knowledge.

Cauda Equina↗

Extruded lumbar osseous endplate causing long-term radiculopathy in an adult: an endoscopic excision.

In this report, we described an adult case that had a long-term radiculopathy due to an extruded osseous endplate of the lumbar spine at the L5-S1 intervertebral disc level. The osseous material inside the extruded material was not absorbed, and it had continued compressing the nerve root for one year. Endoscopically, the bony fragment was successfully removed. After the surgery, the patient's symptom disappeared, and neurological deficits became normalized. In conclusion, we propose that surgical intervention should be taken into account for the treatment of HNP, when the extruded material contains bony fragment such as osseous endplate.

Adult↗

Biomechanical comparison of lumbar spine with or without spina bifida occulta. A finite element analysis.

STUDY DESIGN: Biomechanical study using finite element model (FEM) of lumbar spine. OBJECTIVES: Very high coincidence of spina bifida occulta (SBO) has been reported more than in 60% of lumbar spondylolysis. The altered biomechanics due to SBO is one considerable factor for this coincidence. Thus, in this study, the biomechanical changes in the lumbar spine due to the presence of SBO were evaluated. SETTING: United States of America (USA). METHODS: An experimentally validated three-dimensional nonlinear FEM of the intact ligamentous L3-S1 segment was used and modified to simulate two kinds of SBO at L5. One model had SBO with no change in the length of the spinous process and the other had a small dysplastic spinous process. Von Mises stresses at pars interarticularis were analyzed in the six degrees of lumbar motion with 400 N axial compression, which simulates the standing position. The range of motion at L4/5 and L5/S1 were also calculated. RESULTS: It was observed that the stresses in all the models were similar, and there was no change in the highest stress value when compared to the intact model. The range of motion was also similar in all the models. The lumbar kinematics of SBO was thus shown to be similar to the intact model. CONCLUSION: SBO does not alter lumbar biomechanics with respect to stress and range of motion. The high coincidence of spondylolysis in spines with SBO may not be due to the mechanical factors.

Biomechanical Phenomena↗

Biomechanical rationale of endoscopic decompression for lumbar spondylolysis as an effective minimally invasive procedure - a study based on the finite element analysis.

We evaluated the biomechanical behavior of the endoscopic decompression for lumbar spondylolysis using the finite element technique. An experimentally validated, 3-dimensional, non-linear finite element model of the intact L3 - 5 segment was modified to create the L4 bilateral spondylolysis and left-sided endoscopic decompression. The model of Gill's laminectomy (conventional decompression surgery of the spondylolysis) was also created. The stress distributions in the disc and endplate regions were analyzed in response to 400 N compression and 10.6 Nm moment in clinically relevant modes. The results were compared among three models. During the flexion motion, the pressure in the L4/5 nucleus pulposus was 0.09, 0.09 and 0.16 (MPa) for spondylolysis, endoscopic decompression and Gill's procedure, respectively. The corresponding stresses in the annulus fibrosus were 0.65, 0.65 and 1.25 (MPa), respectively. The stress at the adjoining endplates showed an about 2-fold increase in the Gill's procedure compared to the other two models. The stress values for the endoscopic and spondylolysis models were of similar magnitudes. In the other motions, i. e., extension, lateral bending, or axial rotation, the results were similar among all of the models. These results indicate that the Gill's procedure may lead to an increase in intradiscal pressure (IDP) and other biomechanical parameters after the surgery during flexion, whereas the endoscopic decompression did not change the segment mechanics after the surgery, as compared to the spondylolysis alone case. In conclusion, endoscopic decompression of the spondylolysis, as a minimally invasive surgery, does not alert mechanical stability by itself.

Biomechanical Phenomena↗

Union of defects in the pars interarticularis of the lumbar spine in children and adolescents. The radiological outcome after conservative treatment.

Lumbar spondylolysis can heal with conservative treatment, but few attempts have been made to identify factors which may affect union of the defects in the pars. We have evaluated, retrospectively, the effects of prognostic variables on bony union of pars defects in 134 young patients less than 18 years of age with 239 defects of the pars who had been treated conservatively. All patients were evaluated by CT scans when first seen and more than six months later at follow-up. The results showed that the spinal level and the stage of the defects were the predominant factors. The site of the defects in the pars, the presence or development of spondylolisthesis, the condition of the contralateral pars, the degree of lumbar lordosis and the degree of lumbar inclination all significantly affected union.

Adolescent↗

Effects of active recovery under a decreasing work load following intense muscular exercise on intramuscular energy metabolism.

The effect of active recovery at a decreasing % of MVC following intense muscular exercise on intramuscular pH was investigated in vivo using 31P-MRS. Seven healthy men participated, and their right wrist flexor muscle group was examined. The subjects were asked to flex their right wrist at 60 % of the maximum voluntary contraction (MVC) every 2 s until the intracellular pH in the wrist flexor muscle decreased to 6.4. After the exercise period, the subjects underwent active or passive recovery for 10 min. For the active recovery (AR), the subject was asked to continue exercising at a decreasing % of MVC, decreasing from 25 to 5 % MVC every two min during AR. 31P-MR-spectra were obtained throughout the experiments, and from the spectra the intracellular pH (pHi) was calculated as an indicator of intracellular events. AR data were compared to data collected during passive recovery (PR). During AR, the pHi increased immediately after the exercise period; whereas in that of PR, it did not recover within 5 minutes after exercise. The results suggested that mild exercise was an effective manoeuver to promote recovery from intramuscular metabolic acidosis.

Adult↗

Characteristics of velocity-controlled knee movement in patients with cervical compression myelopathy: what is the optimal rehabilitation exercise for spastic gait?

STUDY DESIGN: The isokinetic strength of knee extensors and flexors was measured at various controlled velocities in patients with spastic paraparesis caused by cervical compression myelopathy. OBJECTIVE: To evaluate leg function objectively in patients with myelopathy. SUMMARY OF BACKGROUND DATA: Cervical compression myelopathy causes varying degrees of spastic paresis in the legs and affects the activities of patients. However, the leg function characteristics of the patients have not been fully elucidated. METHODS: Velocity-controlled voluntary knee movements were studied in 39 patients (25 men and 14 women) with compression myelopathy. Their mean age was 60.2 years (range, 44-77 years). The patients were divided into Group A (ambulation without aid, n = 22) and Group AA (ambulation with aid, n = 17). Isometric peak torque values were measured in knee flexor and extensor muscles at 60 degrees of knee flexion, and isokinetic peak torque values were determined in maximal voluntary concentric movements of these muscles at constant angle velocities of 40 degrees, 80 degrees, 120 degrees, 160 degrees, and 180 degrees per second. The relative strength (percentage of isometric peak torque value) of the isokinetic motion was calculated at each velocity. RESULTS: In both groups, the relative strength decreased as the velocity increased, and the degree of reduced strength in the flexors at the high velocities of 160 degrees and 180 degrees per second was significantly greater in Group AA than in Group A (P < 0.05), whereas no significant difference was found in the extensors between the groups. CONCLUSIONS: The results indicate that isokinetic strength at a high velocity may reflect the severity of spastic paresis in the legs resulting from compression myelopathy.

Aged↗

Slippage mechanism of pediatric spondylolysis: biomechanical study using immature calf spines.

STUDY DESIGN: This study analyzed the skeletal-age-dependent strength of the lumbar growth plate to resist anterior shearing forces using the MTS system in the immature calf spine with pars defects. OBJECTIVE: To clarify the pathomechanism of the skeletal-age-dependent incidence of slippage in pediatric patients with pars defects by comparing the strength of the lumbar growth plate among three skeletal age groups. SUMMARY OF BACKGROUND DATA: Isthmic spondylolisthesis occurs and progresses more frequently during the growth period, whereas it is rare afterward. However, little evidence has been demonstrated to elucidate the etiology. METHODS: For this study, 15 lumbar functional spine units were divided into three groups according to their skeletal ages. Five were from neonates (Group 1), five from calves approximately 2 months old (Group 2), and five from calves about 24 months old (Group 3). An anterior shearing force was applied to each specimen until failure, after bilateral pars defects were created. Failure load (newtons) and displacement at failure (millimeters) were calculated from the load-displacement curve. The site of failure was confirmed by plain radiograph. RESULTS: All 15 functional spine units failed at the growth plate. The failure load was 242.79 +/- 46.05 N in Group 1, 986.40 +/- 124.16 N in Group 2, and 2024.54 +/- 245.53 N in Group 3. Statistically significant differences were found among the three groups (P < 0.05). The displacement at failure was 7.52 +/- 1.84 mm in Group 1, 11.10 +/- 2.30 mm in Group 2, and 8.15 +/- 2.66 mm in Group 3. There were no significant differences among the groups. CONCLUSIONS: The results indicate that the strength of the growth plate, the weakest link in this model, against anterior shearing forces depends on the skeletal maturity, and that the biomechanical weakness of the growth plate plays an important role in the slippage mechanism.

Aging↗

The pathomechanism of spondylolytic spondylolisthesis in immature primate lumbar spines in vitro and finite element assessments.

STUDY DESIGN: Immature Chacma baboon (Papio ursinus) spine specimens were used to determine load-displacement behavior as related to disc injury. This was accomplished through the application of A-P shear force until failure of FSUs with pars defects. Several finite element models (FEMs) of the FSU were developed to study the mechanism of slippage in immature baboon lumbar spines. OBJECTIVES: The purpose was to show that spondylolisthesis (olisthesis) always occurs through the growth plate using a model similar to immature human lumbar spines. Using FEMs, the roles of facet orientation, pars interarticularis thickness, and a weak growth-plate in producing slippage were examined. SUMMARY OF BACKGROUND DATA: Progression from spondylolysis (lysis) to olisthesis occurs, most often, during the adolescent growth spurt. The biomechanical literature dealing with the slippage mechanism in the immature lumbar spine does not provide a clear understanding and is sparse. METHODS: Several groups of FSUs were subjected to A-P shear force until failure. The results provided displacement at failure as a function of disc injury and flexion-extension fatigue. A bilateral pars defect was created in each specimen prior to application of A-P shear force using an MTS machine. Failure sites were assessed radiographically and histologically. A nonlinear 3-D FEM of the intact L4-L5 was created from CT scans. The model was modified to predict the effects of a pars fracture, a thin pars, a weak growth plate, and facet orientation on the shear load through the growth plate and stresses in the pars. RESULTS: Experimentally, failures always occurred through the growth-plate in the disc intact and disc-incised groups. In the intact FEM, the growth plate carried21% of the applied A-P shear force. The load increased when the facets were more sagittally oriented. The effect of thin pars and/or weaker growth plate was an increase in stresses in the pars. Changes in the load through the growth plate were minimal. CONCLUSIONS: The weakest link in immature baboon lumbar functional spinal units (FSUs) with lysis during an A-P shear load was the growth plate, between the cartilaginous and osseous end plates. Surgeons may assess this lesion on MRI views, thereby predicting the possible development and preventing progression of olisthesis. Finite element model results predict that more sagittally orientated facets and/or a pars fracture are prerequisites for olisthesis to occur.

Age Factors↗

Effects of ovariectomy on intramuscular energy metabolism in young rats: how does sports-related-amenorrhea affect muscles of young female athletes?

The purpose of this study was to evaluate the effects of ovariectomy on intramuscular energy metabolism in young rats. Twenty-four Sprague-Dawley rats (7 weeks old) were used. Twelve of them underwent ovariectomy (OVX), and the others were sham-operated on. Seven OVX rats were examined 1-week after surgery (OVX-1 group), and the other five, 4 weeks after surgery (OVX-4 group). The gastrocnemius-plantaris-soleus (GPS) muscles group was subjected to the following measurements, and the data were compared with those of the sham group (Sham-1: n = 7, or Sham-4 group: n = 5). From the 31P-MR spectra of the GPS muscles group at rest and during electric stimulation, the muscular oxidative capacity was measured. Maximum tension and wet weight of the whole GPS muscles group were also measured. Body weight in the OVX-4 group was significantly (p < 0.01) larger than that in the Sham-4 group. The weights of the whole GPS muscles group in the Sham-1, Sham-4, OVX-1 and OVX-4 groups were 1.17, 1.51, 1.25 and 1.71 (g), respectively. The muscle weight in the OVX group tended to be greater than that in the Sham group (p < 0.10). The maximum tension and oxidative capacity did not differ significantly among the groups. These data indicated that in young rats, ovariectomy induced an increase in body and muscle weight, but did not affect the maximum tension nor oxidative capacity.

Amenorrhea↗

Evaluation of disuse atrophy of rat skeletal muscle based on muscle energy metabolism assessed by 31P-MRS.

The purpose of this study was to evaluate disuse atrophy of skeletal muscle using a hind-limb suspension model, with special reference to energy metabolism. Twenty-four Sprague-Dawley rats were divided into four groups: control group (C), hind-limb suspended for 3 days (HS-3), for 7 days (HS-7) and for 14 days (HS-14). The gastrocnemius-plantaris-soleus (GPS) muscles in each group were subjected to the following measurements. After a 2-min rest, contraction of the GPS muscles was induced by electrical stimulation of the sciatic nerve at 0.25 Hz for 10 min, then the frequency was increased to 0.5 and 1.0 Hz every 10 min. During the stimulation, twitch forces were recorded by a strain gauge, and 31P-MRS was performed simultaneously. Maximum tension was measured at the muscle contraction induced at 0.25 Hz; the wet weight of the whole and each muscle in the GPS muscles was also measured. From the 31P-MR spectra during muscle contraction, the oxidative capacity was calculated and compared among the groups. The weights of the whole GPS muscles in C, HS-3, HS-7 and HS-14, were 2.66 +/- 0.09, 2.39 +/- 0.21, 2.34 +/- 0.21 and 2.18 +/- 0.14 (g) respectively. Thus, the muscle mass significantly decreased with time (p < 0.05). Among the GPS muscles, the decrease in weight of the soleus muscle was especially remarkable; in the HS-14 group its weight decreased to 60% of that in the C group. We evaluated maximum tension and oxidative capacity as the muscle function. The maximum tensions in C, HS-3, HS-7 and HS-14 were 519 +/- 43, 446 +/- 66, 450 +/- 23 and 465 +/- 29 (g), respectively. This was significantly greater in the C group than in any other groups, however there were no significant differences among the three HS groups. The oxidative capacity during muscle contraction in the C group was higher than in any HS group and it did not further decrease even if the suspension of the limbs was prolonged beyond 3 days. The present study showed that in disuse atrophy, muscle mass and muscle function did not change simultaneously. Thus, it is necessary to develop countermeasures to prevent muscle atrophy and muscle function deterioration independently.

Animals↗

Biomechanical studies of a dynamized anterior thoracolumbar implant.

STUDY DESIGN: An in vitro investigation into the biomechanical properties of a dynamized anterolateral compression implant that allows controlled subsidence. OBJECTIVES: To determine the extent to which both modes of the anterolateral compression implant (controlled collapsing and rigid) are able to reestablish the stability of the lumbar spine after L4 corpectomy. SUMMARY OF BACKGROUND DATA: Over time, anterior and posterior spinal implants have been associated with progressive angulation, and occasionally implant failure and breakage. To circumvent this occurrence and provide better graft loading, dynamized or collapsing devices for clinical use have been developed. METHODS: Eight fresh calf spines (L1-L6) were placed in a biomechanical testing frame. Pure moments of 6 Nm were loaded onto the intact spine in six directions: flexion, extension, right and left lateral bending, and right and left axial rotation. A total L4 corpectomy then was performed, and the defect grafted with a wooden dowel. Loading was repeated after the specimens were stabilized using the two modes of the anterolateral compression implant in succession. RESULTS: The results showed that both modes of the implant (the rigid mode in particular) restore the stiffness of the unstable spine to normal levels of flexion, extension, and right and left lateral bending, even to levels exceeding normal. These devices, however, fall short of achieving normal stability in right and left axial rotation. CONCLUSION: In the cadaveric calf spine after L4 corpectomy, restoration of stability with a dynamized anterior spinal implant is possible in flexion, extension, and right and left lateral bending, but not in axial rotation.

Animals↗

Effects of specific warm-up at various intensities on energy metabolism during subsequent exercise.

BACKGROUND: To investigate the effects of specific warm-up at various intensities on energy metabolism during subsequent intense exercise. METHODS EXPERIMENTAL DESIGN: specific warm-up was consisted of 3 sets of wrist flexions for 5 min, with each set followed by a 3-min rest. The intensity of specific warm-up was set at 20%, 30% or 40% of maximal voluntary contraction (MVC). The subjects then performed a set of wrist flexions at 60% MVC for 4 min as the criterion exercise. For the control experiment, criterion exercise was done without specific warm-up. PARTICIPANTS: Five healthy volunteers. MEASUREMENTS: using phosphorus-31 magnetic resonance spectroscopy, spectra were obtained from the wrist flexor muscles to determine the ratio of inorganic phosphate to phosphocreatine (Pi/PCr) and intracellular pH. RESULTS: The Pi/PCr during the criterion exercise after specific warm-up at any intensity was not significantly different from that without specific warm-up. The intracellular pH during the criterion exercise after specific warm-up at 30% or 40% MVC was significantly higher than that without specific warm-up. CONCLUSIONS: These results indicate that mild warm-up exercise could inhibit the development of intracellular acidosis during subsequent intense exercise.

Adult↗

Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model.

STUDY DESIGN: An in vitro test of calf spine lumbar segments to compare biomechanical stabilization of a rigid versus a dynamic posterior fixation device. OBJECTIVES: To compare flexibility of a dynamic pedicle screw fixation device with an equivalent rigid device. SUMMARY OF BACKGROUND DATA: Dynamic pedicle screw device studies are not as prevalent in the literature as studies of rigid devices. These devices contain the potential to enhance load sharing and optimize fusion potential while maintaining stability similar to that of rigid systems. METHODS: Load-displacement tests were performed on intact and stabilized calf spines for the dynamic and rigid devices. Stability across a destabilized L3-L4 segment was restored by insertion of either a 6 mm x 40 mm dynamic or rigid pedicle screw fixation device across the L2-L4 segment. The screws then were removed, 7 mm x 45 mm pedicle screws of the opposite type were inserted, and the construct then was re-tested. Axial pull-out tests were performed to assess the likely effects of pedicle screw replacement on the load-displacement data. RESULTS: Results indicated a 65% reduction in motion in flexion-extension and a 90% reduction in lateral bending across the destabilized level for both devices, compared with intact spine values. Reduction in axial rotation motion was much smaller than in other modes. Axial pull-out tests showed no weakening of the bone-screw interface. CONCLUSIONS: Both devices provided significant stability of similar magnitudes in flexion, extension, and lateral bending. In axial rotation, the devices only could restore stability to levels similar to those in an intact spine. The dynamic device offers a design that may enhance load sharing without sacrificing construct stability.

Animals↗

The pathomechanism of isthmic lumbar spondylolisthesis. A biomechanical study in immature calf spines.

STUDY DESIGN: Anterior shearing force was applied to immature calf lumbar functional spinal units until failure. OBJECTIVES: To clarify the mechanism of slippage in immature calf lumbar spines with pars defects as a first step to understand the mechanism of spondylolisthesis in pediatric human lumbar spines. SUMMARY OF BACKGROUND DATA: Progression from lysis to olisthesis occurs during the adolescent growth spurt. However, the mechanism of slippage in the immature lumbar spine has not yet been understood clearly. METHODS: Bilateral pars defects were created at the rostral vertebra. The specimens then were assigned to one of the two groups: functional spinal units with intact disc (n = 5) and with disc dissected (n = 5). In the former group, the disc was left intact, whereas in the disc dissected group, the anterior longitudinal ligament and 75% of the anterior-to-posterior depth of the disc were incised along the mid-disc plane. Using a uniaxial MTS machine (MTS System, Minneapolis, MN), anteroposterior shearing force was applied to each specimen. Failure load and displacement at failure were calculated from the load--displacement curve. Failure sites also were assessed radiographically and histologically. RESULTS: The five functional spinal units in the intact disc group failed at 973.8 +/- 78.1 N, whereas specimens in the disc dissected group failed at 986.4 +/- 124.2 N. The data showed no significant differences between the two groups. All the specimens showed displacement through the growth plates on radiographs. Histologically, failure was observed to occur between the superior growth plate and osseous endplate of caudal vertebra, indicating that this site is the weakest link. CONCLUSIONS: The results suggest that in the pediatric immature lumbar spine with pars defects, slippage may occur between the growth plate and osseous endplate.

Animals↗

Neurocentral synchondrosis fracture in immature spines associated with pedicle screw type fixation devices.

The purpose of this study is to clarify the weak point in immature lumbar vertebrae associated with pedicle screw instrumentation. Ten immature thoracic and lumbar vertebrae were collected from calf spines. After installation of 6- and 7-mm-diameter pedicle screws into the pedicles of each specimen, pullout force was applied to the screw using the uniaxial MTS system until failure. Tightening torque during installation was measured. From the load-displacement curve, failure load was calculated and failure site was confirmed by radiographs. Inner pedicle diameters were measured after the pullout test, and percent fills of the pedicle screw were calculated. Mean tightening torque was 1.4 or 2.1 (Nm), mean failure load was 852.5 or 1,015.0 (N), and mean percent fill was 81.4 or 93.5% for 6- or 7-mm screws, respectively. Tightening torque and percent fill in 7-mm screws were significantly (p < 0.01) greater than that in 6-mm screws; however, failure load showed no significant difference (p = 0.10) between the two screw groups. Failure by screw pullout occurred at the screw-bone interface or through the neurocentral synchondrosis (NS). NS fractures were observed in 20% of 6-mm screws, 60% of 7-mm screws, and 40% overall, whereas interface failures occurred in 80% of 6-mm screws, 40% of 7-mm screws, and 60% overall. In NS fracture group, tightening torque (p < 0.05) and percent fill (p < 0.01) were significantly greater than in the interface failure group. The results led us to conclude that the mechanism of the NS fracture is unclear. However, NS fracture could be one of the conceivable complications associated with pedicle screw fixation in the immature spine.

Animals↗

Foramen magnum schwannoma with an unusual clinical presentation: case report.

This case report illustrates a patient with a unilateral localized epidural schwannoma at C1-2 level, showing contralateral spinal cord symptoms and signs. The clinical presentation was compared with the neuroradiological examinations showing an epidural cord tumor at the right C1-C2 level. However, the neurological examination revealed contralateral hemiparesis and ipsilateral hemihypoalgesia, indicating a contralateral Brown-Sequard syndrome. We presumed with this slow growing tumor, contralateral cord involvement may result from counter pressure on the spinal cord, which may be generated by cord deviation and by frequent neck rotation.

Brain Neoplasms↗