The role of (111)In Capromab Pendetide (Prosta-ScintR) immunoscintigraphy in the management of prostate cancer.

(111)In Capromab Pendetide (ProstaScintR) is a whole murine antibody that is reactive with prostate specific membrane antigen (PSMA), a glycoprotein on the surface of normal and abnormal prostate epithelium. It has proven to be of great value in assisting management decisions in prostate cancer patients who initially present with high risk for metastatic spread, or who develop a picture of recurrent disease after surgery or radiation therapy. Patterns of metastatic lymphatic spread have correlated well with autopsy reports in the literature. Unfortunately, other imaging study and/or histologic confirmation of scintigraphic findings has been difficult to obtain. Prostascint's role in predicting durable complete response (DCR) in postoperative patients having salvage radiotherapy to their prostate fossa is very promising. Further investigative work in larger patient populations is needed to confirm these early results.

Antibodies, Monoclonal↗

Radionuclide renal scan findings in rupture of the ureter: a case report.

Radionuclide renal scan findings in a patient with iatrogenic rupture of the ureter are reported. Although the literature contains reports of the radionuclide scan in rupture of the ureter from other causes, this, to our knowledge is the first description of the scan findings in iatrogenic rupture.

Aged↗

Role of In-111 labeled CYT-103 immunoscintigraphy in the evaluation of patients with recurrent colorectal carcinoma.

An immunoconjugate of the whole antibody, B72.3, has been approved by the FDA. It is labeled with indium-111, which allows imaging studies intended for the diagnosis and staging of colorectal and recurrent ovarian carcinoma. The new diagnostic imaging agent (CYT-103), Oncoscint CR/OV, has found particular use in evaluating patients with recurrent carcinoma. The three major indications for the study are: 1) occult disease--unexplained rise in serum tumor markers (e.g. CEA), with negative work-up including CT; 2) known local recurrence (e.g. liver or rectal area)--surgery is planned, but there is a need to rule out other areas of involvement; 3) clarify equivocal CT or MRI finding--to distinguish whether an abnormality is due to recurrent tumor or scar tissue, fibrosis, or unopacified bowel loop. Oncoscint has proven to be more sensitive than CT in the detection of disease in the pelvis and extrahepatic abdomen. CT remains the modality of choice for the detection of liver metastases. The combined sensitivity of the two modalities is 88% on a per-patient basis.

Adult↗

Measurement of effective renal plasma flow: a comparison of methods.

We have compared two in vitro methods and three variations of kidney background (BG) subtraction within a gamma camera method (41 examinations, 31 patients) for determination of effective renal plasma flow (ERPF) using 131I orthoiodohippurate (OIH). Method I: plasma samples at 20 and 45 min after OIH injection, ERPF = dose X slope/intercept; Method II: 45-min plasma sample, ERPF = -51.1 + 8.21x + 0.019x2, x = dose/45-min plasma activity/I. Individual kidney and total ERPF were determined from gamma camera (GC) methods using renal uptake 1-2 min after injection. All methods were compared against Method I (previously validated against paraaminohippurate (PAH) clearances). Method II, which requires one blood sample is more accurate than GC methods. GC methods are insensitive to operator variability in placement of renal and BG regions of interest. They may be useful to follow changes in relative or total ERPF, but accurate depth correction of renal data is suggested. In vitro, blood sample-based methods are more accurate.