PubMed Health⌕ Search

Biomedical subjects

K Sasakura

Publications and source records attributed to K Sasakura.

10 recordsLinked to original sources

Development of a sensitive enzyme-linked immunosorbent assay for eotaxin and measurement of its levels in human blood.

The CC chemokine eotaxin is potent eosinophil-selective chemoattractant, and it is thought that the function of eotaxin is closely related to the recruitment of eosinophils in certain inflammatory reactions. In order to learn more about the biological role of this molecule, we have developed a new sandwich ELISA method to measure human eotaxin using two monoclonal anitibodies and purified recombinant eotaxin as a standard. The minimal detectable concentration of eotaxin in this assay was 1.5 pg/ml, and the working range was 3.1--200 pg/ml with low CVs (< 10%). Both within- and between-run precision levels were less than 6.7% of the CVs. The dilution curves of two serum and two spiked plasma samples showed good linearity and the recovery range was 92.8--103.3%. No cross-reactivity was found with other similar chemokines. MCP-1, MCP-2, MCP-3, MCP-4, eotaxin-2 and RANTES. This assay was sensitive enough to measure the circulating eotaxin levels of healthy volunteers. However, the eotaxin levels in serum samples (mean+/-SD; 68.6+/-13.4 pg/ml, n=15) were significantly higher than those in matched plasma samples (19.2+/-5.4 pg/ml) separated from blood collected in tubes containing EDTA. Kinetic studies revealed that the eotaxin levels in serum markedly increased depending on the elapsed time before separation from blood cells, but such changes in EDTA-plasma were negligible up to 4 h at 25 degrees C. Our new ELISA is an accurate and useful method for quantifying human eotaxin in blood and demonstrates that the process of preparing blood samples affects the measurement of the eotaxin levels.

Chemokine CCL11↗

A simple immunoradiometric assay for measuring the entire molecules of adrenomedullin in human plasma.

We developed a one-step two-site immunoradiometric assay (IRMA) using two kinds of monoclonal antibodies, which enables us to directly measure the entire molecules of adrenomedullin (AM) (the sum of mature-type AM (abbreviated, m-AM) amidated at the C-terminus and Gly-extended non-amidated AM) in human plasma using a small amount of sample (100 microl) without prior extraction. The detection limit of this assay was 0.5 pmol/l for a 100-microl sample. Intra- and inter-assay precisions were 3.4-7.3% and 5.8-7.6%, respectively. The dilution curves of plasma samples showed good linearity and analytical recovery was 89-118%. The mean total AM in plasma of healthy subjects was 9.00+/-2.13 pmol/l, whereas m-AM was 1.05+/-0.24 pmol/l. This method, together with our previously reported simplified method to specifically measure m-AM (Ohta et al., Clin Chem 1999;45:244-251), allows facile estimation of the plasma concentration of AM-Gly by subtracting m-AM from the total AM measured by the procedure described in this paper. We were able to show that the concentration of total AM in patients with sepsis was markedly higher than that in the healthy controls and that the ratios of m-AM/total AM were significantly different between the controls and patients.

Adrenomedullin↗

One-step direct assay for mature-type adrenomedullin with monoclonal antibodies.

Adrenomedullin (AM) is a potent hypotensive peptide. Plasma contains mature-type AM (m-AM), which is amidated at the carboxy terminus, and an intermediate, AM-Gly. We developed a one-step two-site IRMA specific for determining human m-AM with monoclonal antibodies. The detection limit was 0.5 pmol/L, and the working range (CV <15%) was 1-300 pmol/L. Dilution of plasma samples showed good linearity. The recovery of added AM was 91-118%. The intra- and interassay imprecision values (CVs) were 4.4-8.2% and 5.5-8.3%, respectively. The assay had no cross-reactivity with AM-Gly or other peptides similar to AM. The mean (+/- SD) plasma human m-AM concentration of 61 healthy subjects was 1.18 +/- 0.65 pmol/L. In conclusion, our IRMA makes it possible to specifically measure m-AM, using a small amount of plasma sample (0.2 mL) by a one-step overnight assay without prior extraction. Our simplified method would be suitable for clinical studies on AM, especially when large numbers of samples must be processed.

Adrenomedullin↗

Structure-function studies of human leptin.

To elucidate the structural requirement of human leptin for its functions, the wild-type, mutant-type, C-terminal deletion, and N-terminal deletion were expressed in Escherichia coli and purified in soluble forms. These leptin analogs were intracerebroventrically injected into C57BL/6J ob/ob mice, and their in vivo biological activities were evaluated. The mutant-type leptin lacking a C-terminal disulfide bond reduced food intake at doses of more than 15 pmol/mouse, which was as effective as the wild-type leptin. C-terminal deletion without the loop structure, also significantly, but to a lesser extent, reduced food intake at doses of more than 90 pmol/mouse. However, N-terminal deletions showed no effect on food intake. We also evaluated the effects of the leptin analogs on radiolabeled leptin binding to its receptor in the choroid plexus using autoradiography. An excess of unlabeled mutant-type leptin as well as wild-type leptin led to complete inhibition of binding. C-terminal deletions led to weak inhibitory activity, whereas N-terminal deletions caused no inhibitory activity. These results clearly demonstrate that the N-terminal region of leptin is essential for both its biological and receptor binding activities. The amino acid sequence of the C-terminal loop structure is also important for enhancing these actions, whereas the C-terminal disulfide bond is not needed.

Animals↗

Immunoradiometric assay for the N-terminal fragment of proatrial natriuretic peptide in human plasma.

Recently, the N-terminal fragment of proatrial natriuretic peptide (N-terminal proANP) has been proposed as a marker of chronic congestive heart failure. In this study, we established a two-step immunoradiometric assay using monoclonal antibodies and synthetic N-terminal proANP (1-67) as a standard. It allows us to measure plasma N-terminal proANP in only 4 h without prior extraction. The detection limit of this assay was 15 pmol/L for a 100 microL sample of plasma. Within-run CVs ranged from 1.7% to 2.9% and between-run CVs ranged from 4.2% to 5.1%. The dilution curves of plasma samples showed good linearity and analytical recovery was 89-104%. The mean (+/-SD) N-terminal proANP in plasma of 33 healthy subjects was 188 (+/-71) pmol/L and 1030 (+/-411) pmol/L in 25 patients with heart failure. Our immunoradiometric assay is rapid and precise enough for routine determination of N-terminal proANP in human plasma.

Antibodies, Monoclonal↗

Development of a sensitive ELISA for human leptin, using monoclonal antibodies.

A new, sensitive ELISA for human leptin in plasma and cerebrospinal fluid (CSF) was developed, using monoclonal antibodies. The lower limit of detection of this ELISA was 0.78 pg/assay. Both intra- and interassay imprecision values were <7%. The dilution curves of plasma and CSF showed good linearity, and the recovery was 83.2-95.6%. There was good correlation between plasma leptin concentrations by the ELISA and a commercially available RIA (r = 0.99). Our ELISA is advantageous because it does not require radioisotopes, it produces results in hours rather than days, and more importantly, it improves on the detection limit and plasma interference of the RIA kit. The new ELISA enables measurement of low concentrations of leptin, as are seen in CSF and in plasma of patients with anorexia nervosa.

Adipose Tissue↗

1-Azacycloalkyl-1,4-benzodiazepin-2-ones with antianxiety-antidepressant actions.

A series of 1-azacycloalkyl-1,4-benzodiazepin-2-ones were synthesized from 1-azacycloalkyl-2-benzoylanilines and corresponding imines and then evaluated for their central nervous system activities. Pharmacological data showed that some of these compounds have potent antidepressant properties, as assessed by their antagonism of tetrabenzine (TBZ) induced ptosis and their inhibition of [3H]norepinephrine uptake into rat brain synaptosomes, as well as their moderate antianxiety properties of preventing of pentylenetetrazol (PTZ) convulsion, suppressing conflict behavior, and displacing potential for [3H]diazepam binding. Introduction of a halogen substituent at position 7 of the 1,4-benzodiazepine ring lengthened the anti-PTZ effects, although the peak effect was slightly reduced and clearly enhanced the anti-PTZ and anticonflict properties. Introduction of Cl to the ortho position of the phenyl ring at position 5 greatly reduced the antidepressant properties. The secondary amine function of the azacyclic ring at position 1 was essential for the production of the antidepressant properties. Of these new series, 7-fluoro-5-(2-fluorophenyl)-1,3-dihydro-1-(4-piperidinyl)-2H-1,4-benzodi azepin-2 -one has the potential to become a useful antidepressant drug with a moderate antianxiety property.

Animals↗

Peptidoaminobenzophenones, a novel class of ring-opened derivatives of 1,4-benzoidazepines.

A series of noval peptidoaminobenzophenones has been prepared via several routes and was evaluated for CNS activity. The structure--activity relationships in the series are discussed. In general, dipeptido-N-methylaminobenzophenones showed higher activities than the corresponding NH derivatives. Some compounds had very high activities in antipentylenetetrazole and antifighting tests in mice when orally administered. Very weak toxicity was also found in these compounds. Water solubility of the peptidoaminobenzophenones and their salts were tested. Possible in these compounds. Water solubility of the peptidoaminobenzophenones and their salts were tested. Possible in vivo conversion of peptidoaminobenzophenone by enzymatic cleavage of the terminal amino acid, followed by chemical cyclization to 1,4-benzodiazepine, is also discussed. Such novel open-ring derivatives of 1,4-benzodiazepine may serve as useful CNS agents.

Aggression↗