PubMed Health⌕ Search

Biomedical subjects

K Scott Phillips

Publications and source records attributed to K Scott Phillips.

6 recordsLinked to original sources

Recent advances in surface plasmon resonance based techniques for bioanalysis.

Surface plasmon resonance (SPR) is a powerful and versatile spectroscopic method for biomolecular interaction analysis (BIA) and has been well reviewed in previous years. This updated 2006 review of SPR, SPR spectroscopy, and SPR imaging explores cutting-edge technology with a focus on material, method, and instrument development. A number of recent SPR developments and interesting applications for bioanalysis are provided. Three focus topics are discussed in more detail to exemplify recent progress. They include surface plasmon fluorescence spectroscopy, nanoscale glassification of SPR substrates, and enzymatic amplification in SPR imaging. Through these examples it is clear to us that the development of SPR-based methods continues to grow, while the applications continue to diversify. Major trends appear to be present in the development of combined techniques, use of new materials, and development of new methodologies. Together, these works constitute a major thrust that could eventually make SPR a common tool for surface interaction analysis and biosensing. The future outlook for SPR and SPR-associated BIA studies, in our opinion, is very bright. Surface plasmon resonance (SPR) is a powerful and versatile spectroscopic method for biomolecular interaction analysis (BIA) and has been well reviewed in previous years. This updated 2006 review of SPR, SPR spectroscopy, and SPR imaging explores cutting-edge technology with a focus on material, method, and instrument development. A number of recent SPR developments and interesting applications for bioanalysis are provided. Three focus topics are discussed in more detail to exemplify recent progress. They include surface plasmon fluorescence spectroscopy, nanoscale glassification of SPR substrates, and enzymatic amplification in SPR imaging. Through these examples it is clear to us that the development of SPR-based methods continues to grow, while the applications continue to diversify. Major trends appear to be present in the development of combined techniques, use of new materials, and development of new methodologies. Together, these works constitute a major thrust that could eventually make SPR a common tool for surface interaction analysis and biosensing. The future outlook for SPR and SPR-associated BIA studies, in our opinion, is very bright.

Biological Assay↗

Surface plasmon resonance imaging analysis of protein-receptor binding in supported membrane arrays on gold substrates with calcinated silicate films.

A new method to fabricate supported bilayer membrane (SBM) arrays for surface plasmon resonance (SPR) imaging analysis is demonstrated in this work. Thin silicate films are produced on gold SPR substrates using layer-by-layer assembly, followed by calcination. Etching into the glassified substrates using photolithographic techniques generates nanowells of desirable size and depth. Atomic force microscopy and SPR imaging analysis show that the features are well-defined, and the etching process appears to have a surface smoothing effect. After the wells are oxidized with strong acid, vesicles spontaneously fuse onto them to form supported membranes with a high degree of lateral mobility. Fluorescence recovery after photobleaching measurements yielded a diffusion coefficient of 1.1 mum2/s. To demonstrate the feasibility for high-throughput receptor-ligand interaction analysis, binding of cholera toxin (CT) to SBM arrays containing 5 mol % ganglioside GM1 receptor was carried out with SPR imaging. The results showed excellent well-to-well reproducibility (8% RSD at 60 nM CT) and marked detection sensitivity.

Calcium↗

Immunosensing of Staphylococcus enterotoxin B (SEB) in milk with PDMS microfluidic systems using reinforced supported bilayer membranes (r-SBMs).

A versatile and novel method has been developed for microfluidic immunosensing of the food-borne pathogen Staphylococcus enterotoxin B (SEB) in poly(dimethylsiloxane) (PDMS) chips. Supported bilayer membranes (SBMs) were generated by vesicle fusion in oxidized PDMS microchannels for minimizing non-specific adsorption of biomolecules. The stability of SBMs was strengthened with a streptavidin layer to make them air-stable and allow for subsequent display of the biotin-functionalized antibodies. The reinforced supported bilayer membranes (r-SBMs) are fluid, exhibiting a lateral diffusion coefficient of approximately 1.9 microm(2) s(-1), and no detectable change of mobility was found after dehydration/rehydration. This is a substantial improvement over phosphatidylcholine (PC) membranes on PDMS, which suffered a roughly 10% reduction in the mobile fraction and 30% decrease in mobility after dehydration. Non-specific protein adsorption in the membrane-treated channels was reduced 100-1000 fold as compared to PDMS surfaces without a membrane coating. A flow-based microfluidic immunosensor for SEB was developed using antibodies linked to the r-SBMs in PDMS channels, and a detection limit of 0.5 ng mL(-1) was obtained from the linear portion of the calibration curve. The microchip was applied to detection of SEB in milk, and similar response and sensitivity were obtained, demonstrating the sensor's remarkable performance for real world samples. The r-SBMs overcome the stability hurdle in SBM-modified surfaces, opening up possibilities for transport and storage of membrane-functionalized microchips in the dehydrated form without compromising the performance, and facilitating the commercialization of disposable SBM-based microdevices.

Adsorption↗

Nanoscale glassification of gold substrates for surface plasmon resonance analysis of protein toxins with supported lipid membranes.

Surface plasmon resonance (SPR) spectroscopy, a powerful tool for biosensing and protein interaction analysis, is currently confined to gold substrates and the relevant surface chemistries involving dextran and functional thiols. Drawbacks of using self-assembled monolayers (SAMs) for SPR-related surface modification include limited stability, pinhole defects, bioincompatibility, and nonspecific protein adsorption. Here we report the development of stable nanometer-scale glass (silicate) layers on gold substrates for SPR analysis of protein toxins. The nanoscale silicate layers were built up with layer-by-layer deposition of poly(allylamine hydrochloride) and sodium silicate, followed by calcination at high temperature. The resulting silicate films have a thickness ranging from 2 to 15 nm and demonstrate outstanding stability in flow cell conditions. The use of these surfaces as a platform to construct supported bilayer membranes (SBMs) is demonstrated, and improved performance against protein adsorption on SBM-coated surfaces is quantified by SPR measurements. SBMs can be formed reproducibly on the silicate surface via vesicle fusion and quantitatively removed using injection of 5% Triton X-100 solution, generating a fresh surface for each test. Membrane properties such as lateral diffusion of the SBMs on the silicate films are characterized with photobleaching methods. Studies of protein binding with biotin/avidin and ganglioside/cholera toxin systems show detection limits lower than 1 microg/mL (i.e., nanomolar range), and the response reproducibility is better than 7% RSD. The method reported here allows many assay techniques developed for glass surfaces to be transferred to label-free SPR analysis without the need for adaptation of protocols and time-consuming synthetic development of thiol-based materials and opens new avenues for developing novel bioanalytical technologies for protein analysis.

Avidin↗

Stable and fluid ethylphosphocholine membranes in a poly(dimethylsiloxane) microsensor for toxin detection in flooded waters.

Highly stable and fluid supported bilayer membranes were fabricated by fusion of positively charged ethylphosphocholine (DOPC+) vesicles into poly(dimethylsiloxane) (PDMS) microchannels for immunosensing of cholera toxin (CT) in flooded waters. Compared to phosphatidylcholine (PC) layers in the microchannels, DOPC+ membranes show exceptionally strong resistance to air-dry damage, as demonstrated by fluorescence recovery after photobleaching (FRAP) measurements and protein adsorption studies. In FRAP experiments, the mobile fraction of PC membranes was found to decrease by 10% upon drying/rehydration and the lateral diffusion coefficient decreased from 2.2 to 1.6 microm(2)/s, whereas the mobile fraction and diffusion coefficient for DOPC+ membranes remain virtually unchanged during this process. Characterization by confocal microscopy reveals that only 1% of the DOPC+ membrane in the microchannels was removed by the drying/rehydration process, as compared to 11% for PC. Protein adsorption trends indicate that the charge of DOPC+ membranes allows for tuning of solution conditions to enable the desired protein-membrane interaction to predominate at the interface. A flow-based immunoassay for bacterial toxin was developed with 5% GM1/DOPC+ membranes in PDMS channels, and a detection limit of 250 amol for CT was obtained from the calibration curves. The assay was successfully applied to detection of CT spiked in water samples from the Santa Ana River, with nearly identical response and sensitivity.

Biosensing Techniques↗

Microfluidic immunoassay for bacterial toxins with supported phospholipid bilayer membranes on poly(dimethylsiloxane).

We report a heterogeneous immunoassay for cholera toxin (CT) using supported bilayer membranes (SBMs) in a poly(dimethylsiloxane) (PDMS) microfluidic device. Phosphatidylcholine membranes assembled on plasma-oxidized PDMS by vesicle fusion bring about favorable surface properties, such as improved wettability and protein resistance. Contact angle measurements show that the lipid membranes can preserve hydrophilic surfaces for hours, whereas untreated substrates rapidly undergo hydrophobic recovery. Fluorescence recovery after photobleaching performed in situ reveals that the membranes have relatively high lateral mobility. Experimental data-fitting to theoretical models yields diffusion coefficients of 1.8 +/- 0.7 microm(2)/s on PDMS and 3.4 +/- 0.8 microm(2)/s on glass. Fluorescence studies utilizing tagged proteins show that SBMs reduce nonspecific adsorption of avidin and BSA on PDMS by 2-3 orders of magnitude, as compared to that on plasma oxidized surfaces. SBMs and their protein-resistant properties are not significantly affected by long flow times, indicating good membrane stability. These studies increase our understanding of the relationship between molecular level interactions and membrane properties, allowing for development of a rapid heterogeneous immunoassay for CT in PDMS microchips with cell surface receptor molecules. Using optimized sample injection and buffer washing conditions, microfluidic immunoassay of CT is complete within 25 min, and a dynamic range over 3 orders of magnitude with a detection limit of 8 fmol of toxin is achieved.

Adsorption↗