PubMed Health⌕ Search

Biomedical subjects

K T Schomacker

Publications and source records attributed to K T Schomacker.

At least 19 recordsLinked to original sources

Long-term effects of photodynamic therapy on fluorescence spectroscopy in the human esophagus.

Clinical interest in laser-induced fluorescence (LIF) spectroscopy and photodynamic therapy (PDT) is growing rapidly and may ultimately lead to close parallel use of these techniques. However, variations in LIF due to photosensitizer retention as well as tissue damage and healing processes may interfere with autofluorescence-based diagnostic methods. We have investigated the compatibility of these two techniques by quantifying PDT-induced changes in LIF in the human esophagus. Fluorescence spectra were collected endoscopically at excitation wavelengths (lambda ex) of 337, 400 and 410 nm in 32 patients. Measurements were performed immediately before and after PDT treatment with porfimer sodium and during follow-up procedures. In the months following PDT regions of reepithelialized squamous showed reduced autofluorescence in comparison with untreated squamous regions (P = 0.0007). Photosensitizer fluorescence was undetectable with lambda ex = 337 nm during follow-up procedures, whereas for lambda ex = 400 and 410 nm porfimer sodium fluorescence was noted for nearly a year after treatment. Therefore, residual photosensitizer fluorescence is likely to affect certain LIF-based diagnostic techniques during a period when patients are at high risk for tumor recurrence. Modification of LIF systems and/or the use of alternative photosensitizers may be required to optimize the detection of lesions in the post-PDT patient. Given the potential of LIF as a method for surveillance following cancer therapy, further investigation of the compatibility of specific LIF approaches with cancer pharmaceuticals may be warranted.

Esophageal Neoplasms↗

In vivo fluence rate and fractionation effects on tumor response and photobleaching: photodynamic therapy with two photosensitizers in an orthotopic rat tumor model.

The effect of fluence rate and light fractionation on phototoxicity was investigated in vivo in an orthotopic rat bladder tumor model. Two photosensitizers, benzoporphyrin derivative monoacid ring A and 5-aminolevulinic acid-induced protoporphyrin IX, were studied. For a given cumulative light dose of 30 J/cm2, enhanced tumor destruction was observed from both photosensitizers when using either lower fluence rates or fractionated light delivery. Photobleaching experiments in vivo demonstrated that the photobleaching rate, however, was not fluence rate dependent. The fluence rate and light fractionation effects on tumor phototoxicity lead to rapid local depletion in oxygen concentration that inhibited subsequent photochemical reactions necessary for efficient photodestruction of tumor cells. Nicotinamide did not enhance photodynamic therapy efficacy, suggesting that the added increase of oxygen within the tumor was not sufficient to enhance photodestruction of hypoxic cell fractions. The independence of the photobleaching rate with fluence rate suggests distinct mechanisms, at least in part, of photodestruction of the tumor and the photosensitizer and that the rate of photosensitizer photo-bleaching may not always be an appropriate monitor for singlet oxygen availability and photodynamic therapy dosimetry.

Aminolevulinic Acid↗

Mucosal exposure to light during routine endoscopy.

BACKGROUND: The spectral irradiance delivered by a variety of gastrointestinal endoscopes was measured as a function of wavelength and used to estimate the amount of light delivered to the mucosal surface during routine endoscopic procedures. METHODS: Spectral irradiances from seven different endoscopes were measured using a commercial spectroradiometer calibrated against a National Institute of Standards and Technology traceable source. RESULTS: The largest maximum irradiance was 8.0 W/cm2 obtained from an endoscope used in transillumination mode. In the typical viewing mode, the largest maximum irradiance measured was 1.6 W/cm2. The majority of the light energy delivered by these gastrointestinal endoscopes was in the visible wavelength region (400 to 700 nm). DISCUSSION: The measurements revealed surprisingly high light exposures in the visible wavelength range. In fact, the estimated tissue exposures can exceed by 40-fold the standards established for skin exposure to light set forth by the American National Standards Institute. Because gastrointestinal endoscopy is widely viewed to be safe, it is probable that the gastrointestinal tract has significant tolerance to light exposure.

Calibration↗

Diagnosis of bladder carcinoma using protoporphyrin IX fluorescence induced by 5-aminolaevulinic acid.

OBJECTIVE: To report the results of a clinical study investigating the diagnosis of malignant and dysplastic bladder lesions by protoporphyrin IX (PPIX) fluorescence and to compare them with those from earlier studies. PATIENTS AND METHODS: The study included 55 patients with suspected bladder carcinoma (at initial diagnosis or at tumour follow-up visits); 130 bladder biopsies from 49 patients were classified by pathological analysis. All patients received an intravesical instillation of 50 mL of a 3% 5-aminolaevulinic acid (ALA) solution a mean of 135 min before cystoscopy, which was then performed under white and blue light. Malignant/dysplastic lesions showing red fluorescence under blue-light excitation were noted and the increase in detection rate calculated. RESULTS: There were 63 benign and 67 malignant/dysplastic areas biopsied; 10 malignant/dysplastic lesions (four transitional cell carcinoma, two carcinoma in situ, four dysplasia) were not detected during routine white-light cystoscopy but were identified under blue light. Fluorescence cystoscopy improved the overall diagnosis of malignant/dysplastic bladder lesions by 18% over standard white-light cystoscopy. The improvement was greater for dysplastic lesions and carcinoma in situ (50%). However, the improvement over standard cystoscopy was less than that found by other groups. CONCLUSION: The ALA-based fluorescence detection system significantly enhanced the diagnosis of malignant/dysplastic bladder lesions. However, determining the optimum drug exposure time requires further investigation using well-characterized instrumentation and study protocols, which would then allow comparison of the results from different groups.

Adult↗

Burn wound assessment in porcine skin using indocyanine green fluorescence.

BACKGROUND: An accurate assessment of deep dermal burns within the first week after burn is still an unresolved clinical problem. Infrared-excited fluorescence of indocyanine green was examined as a method of early determination of burn depth. METHODS: Burns of varying depths were placed on the paraspinal region, flank, and abdomen of swine using a heated brass block. Fluorescence images of the burns were recorded 1, 24, 48, and 72 hours later. RESULTS: The ratio of fluorescence in 64 burn wounds relative to adjacent normal tissue identified wounds that healed and did not heal within 21 days with an accuracy of 100%, after accounting for the age of the burn. Higher fluorescence ratios were observed in newly placed burns relative to older burns having comparable depths. CONCLUSION: Deep partial-thickness burns were differentiated from deep dermal full-thickness burns in a porcine skin burn model independent of body location. Diagnosis was possible between 1 and 72 hours after injury.

Animals↗

Laser ablation of burns: initial clinical trial.

BACKGROUND: Scanning, high-powered carbon dioxide laser ablation of eschar may facilitate blood conservation in patients with burns. METHODS: Twenty-one children with full-thickness burns that required serial excisions were enrolled in a Human Studies Committee approved protocol in which a full-thickness wound was ablated with a rapidly scanned continuous wave carbon dioxide laser system. A control wound was sharply excised, and both wounds were immediately autografted. End points were engraftment at 7 days and serial Vancouver scar scores. RESULTS: The children had an average age of 8.3 +/- 1.2 years, weight of 36.3 +/- 4.9 kg, and burn size of 40% +/- 5.1%. The study wounds were ablated with an average energy of 99.2 +/- 5.7 W; there was no bleeding from 19 successfully ablated wounds. Initial engraftment averaged 94.7% +/- 3.5% in the control sites and 94.7% +/- 3.3% in the study sites (P = 1.0). There was no significant difference in Vancouver scar scores at an average follow-up of 32.0 +/- 5.2 weeks. CONCLUSIONS: This pilot study follows a successful trial of this concept in a porcine model and demonstrates the technical feasibility of laser vaporization of burn eschar in humans with immediate autografting. Further refinement of the technique is required before it can be generally recommended.

Adolescent↗

Colonic polyp differentiation using time-resolved autofluorescence spectroscopy.

BACKGROUND: Steady-state autofluorescence spectroscopy has been examined previously as a technique for distinguishing polyp types during colonoscopy. Although time-resolved methods have shown promise for tissue diagnosis in vitro, they have never been applied endoscopically. The aim of this study was to examine the feasibility of performing time-resolved autofluorescence spectroscopy in vivo and to determine the diagnostic accuracy of the technique as applied to colonic dysplasia. METHODS: A time-resolved spectrometer was used to measure the spectrally resolved transient decay of laser-induced autofluorescence emission from colonic tissue in vivo. RESULTS: Seventeen patients with 24 polyps (13 adenomatous, 11 non-adenomatous) were studied. The autofluorescence decay from adenomas was faster than that from non-adenomas. The measured decay time provided a means of distinguishing adenomas from non-adenomas with a sensitivity of 85%, a specificity of 91%, a positive predictive value of 92%, and a negative predictive value of 83%. CONCLUSIONS: Time-resolved autofluorescence spectroscopy is a promising optical diagnostic technique for determining polyp types in vivo.

Adenomatous Polyps↗

Autofluorescence guided biopsy for the early diagnosis of bladder carcinoma.

PURPOSE: We validate the usefulness of laser-induced autofluorescence for the detection of bladder carcinoma. MATERIALS AND METHODS: We obtained and analyzed fluorescence spectra from 75 patients in whom bladder cancer was suspected. Tissue fluorescence was excited by a nitrogen laser using a quartz optical fiber placed in gentle contact with the area of interest. The laser-induced autofluorescence spectrum was recorded using an intensified optical multichannel analyzer system. Spectra were corrected for the spectral response of the optical system, and the ratios of laser-induced autofluorescence intensities (I) at 385 and 455 nm. (I385/I455) were determined. We had previously established this ratio as a diagnostic algorithm. We included only suspicious bladder lesions (erythematous, edematous, raised and so forth) that were difficult to diagnose by cystoscopy as well as areas from which random biopsies were obtained. The fluorescence ratio algorithm was applied to 130 bladder areas. RESULTS: Of the 130 biopsies obtained during routine cystoscopy 107 (82%) were nonmalignant by histological classification. In contrast, because laser-induced autofluorescence effectively guides biopsies towards malignant lesions, only 30 biopsies (72% fewer) would have been obtained from nonmalignant tissue if the fluorescence ratio that identifies 95% of malignant lesions (95th percentile) had been selected as the decision criterion during standard cystoscopy. CONCLUSIONS: By guiding the surgeon to suspicious lesions that are most likely to be malignant, laser-induced autofluorescence substantially decreases the number of biopsies obtained from nonmalignant tissue during cystoscopy to diagnose bladder carcinoma.

Aged↗

Spectroscopic measurement of diffuse reflectance for enhanced detection of bladder carcinoma.

OBJECTIVES: To assess the diagnostic potential of diffuse reflectance spectroscopy for the detection of bladder carcinoma during cystoscopy. Our hypothesis is that neovasculature in neoplastic (dysplastic and malignant) regions will lead to a blood absorption "signature" that is different from that of normal tissue. METHODS: Diffuse reflectance measurements have been performed in 14 patients undergoing mucosal biopsies or transurethral resection of a bladder tumor. A quartz optical fiber was advanced through the working channel of a cystoscope and placed in gentle contact with the bladder surface. A standard cystoscopy xenon light source was used for illumination and the reflectance spectra were recorded using an optical multichannel analyzer (OMA) system. From the spectra, the relative concentrations of hemoglobin (Hb), oxyhemoglobin (HbO2), oxygen saturation (HbO2%), and the total amount of blood (arbitrary units) were calculated to assess their usefulness in differentiating between neoplastic and benign bladder areas. RESULTS: The spectra of 26 bladder areas (9 malignant areas including 4 carcinomata in situ, 2 dysplastic lesions, and 15 benign areas) have been analyzed. Only the total amount of blood was a useful parameter for the differentiation between neoplastic and benign bladder areas. The sensitivity, specificity, and positive and negative predictive values of this method for neoplastic tissue were found to be 91%, 60%, 63%, and 90%, respectively. CONCLUSIONS: The measurement of diffuse reflectance is a fast, simple, and noninvasive method which allows in vivo determination of bladder blood perfusion. The total blood concentration was increased in neoplastic bladder tissue, making it a tool for tissue diagnosis. The relatively low specificity is a result of inflammatory areas also exhibiting an increased total blood concentration. This pilot study encourages further studies to assess the usefulness of reflectance measurements for enhanced detection of bladder cancer.

Aged↗

Carbon dioxide laser ablation with immediate autografting in a full-thickness porcine burn model.

OBJECTIVE: To compare the long-term clinical and histologic outcome of immediate autografting of full-thickness burn wounds ablated with a high-power continuous-wave CO2 laser to sharply débrided wounds in a porcine model. SUMMARY BACKGROUND DATA: Continuous-wave CO2 lasers have performed poorly as tools for burn excision because the large amount of thermal damage to viable subeschar tissues precluded successful autografting. However, a new technique, in which a high-power laser is rapidly scanned over the eschar, results in eschar vaporization without significant damage to underlying viable tissues, allowing successful immediate autografting. METHODS: Full-thickness paravertebral burn wounds measuring 36 cm2 were created on 11 farm swine. Wounds were ablated to adipose tissue 48 hours later using either a surgical blade or a 150-Watt continuous-wave CO2 laser deflected by an x-y galvanometric scanner that translated the beam over the tissue surface, removing 200 microm of tissue per scan. Both sites were immediately autografted and serially evaluated clinically and histologically for 180 days. RESULTS: The laser-treated sites were nearly bloodless. The mean residual thermal damage was 0.18+/-0.05 mm. The mean graft take was 96+/-11% in manual sites and 93+/-8% in laser sites. On postoperative day 7, the thickness of granulation tissue at the graft-wound bed interface was greater in laser-debrided sites. By postoperative day 180, the manual and laser sites were histologically identical. Vancouver scar assessment revealed no differences in scarring at postoperative day 180. CONCLUSIONS: Long-term scarring, based on Vancouver scar assessments and histologic evaluation, was equivalent at 6 months in laser-ablated and sharply excised sites. Should this technology become practical, the potential clinical implications include a reduction in surgical blood loss without sacrifice of immediate engraftment rates or long-term outcome.

Animals↗

Cell damage induced by Angiovist-370 and 308nm excimer laser radiation.

BACKGROUND AND OBJECTIVE: Radiographic contrast media containing iodine-labeled organic compounds can be present in the irradiated field during laser angioplasty using 308 nm excimer laser radiation. These compounds absorb light at 308 nm and may undergo photochemical reactions that produce products that damage cells. STUDY DESIGN/MATERIALS AND METHODS: This study was undertaken to determine whether photoproducts that damage human lymphocytes in vitro are formed when Angiovist 370 (AV), a contrast medium containing triiodinated aromatic compounds, is exposed to 308 nm radiation. RESULTS: The absorption spectrum of AV developed a new peak at 360 nm that extended to wavelengths greater than 500 nm when dilute AV solutions were exposed to 308 nm radiation indicating that photoproducts were formed. Irradiating dilute AV solutions above a layer of human lymphocytes caused a dose-dependent decrease in thymidine incorporation using fluence rates between 5.2 x 10(6) and 1.0 x 10(8) W/cm2. Decreased DNA synthesis was independent of the pulse length (10 ns vs. 230 ns) but was lower, at a given dose, when the highest fluence rate was used. Incubation of lymphocytes with preirradiated AV solutions also decreased incorporation of thymidine in a radiation dose-dependent manner. The cell damaging photoproducts in preirradiated AV solutions were unstable; within 15 min, the effectiveness had decreased by approximately 85%. CONCLUSIONS: These results indicate that exposure of AV to 308 nm excimer laser radiation produces photochemical products that damage human cells in vitro.

Angioplasty, Balloon, Laser-Assisted↗

Improved osteoinduction of cortical bone allografts: a study of the effects of laser perforation and partial demineralization.

Massive cortical bone allografts have been found to incorporate slowly into host bone and thus are subject to complications such as nonunion, fatigue fracture, and infection. To better understand and improve the process of osteoinduction in these types of bone grafts, a new experimental model was developed with use of diaphyseal cortical bone grafts from rat tibiae that were prepared by partial demineralization and drilling of 0.33 mm diameter holes with a pulsed, 2.94 microns wavelength, erbium:yttrium-aluminum-garnet laser. Six types of grafts were analyzed: untreated (Type I), demineralized 25 microns deep (Type II), demineralized 150 microns deep (Type III), laser perforated (Type V), laser perforated and then demineralized 25 microns deep (Type V), and laser perforated and then demineralized 150 microns deep (Type VI). The graft was orthotopically transplanted in the tibia of an adult Sprague-Dawley rat and followed for as long as 4 months. Histologic evaluation at 1 and 4 months postoperatively with use of hematoxylin and eosin staining confirmed that there was new bone growth in Types II, III, V, and VI grafts. The amount of growth was estimated by comparing bone mineral density before implantation with values obtained after retrieval of the graft. These measurements were correlated to histomorphometric analysis of graft incorporation. The results show that the processes of partial demineralization (p < 0.000001) and laser perforation with partial demineralization (p < 0.000001) were both significant in enhancing bone growth in this model. New bone growth was significantly increased when the grafts were prepared with extensive demineralization (p < 0.015). This study demonstrates that osteogenesis in cortical bone grafts can be fostered through the process of partial demineralization and laser perforation. To the extent that minimal partial demineralization and laser perforation allow maintenance of structural integrity while altering the osteoinductive properties in such a way as to promote ingrowth of new bone, this experimental model represents an advance in understanding how osteogenesis in cortical bone grafts may be improved.

Animals↗

An electron microscopic study on the process of acid demineralization of cortical bone.

Demineralization has been shown to foster osteoinductive properties of cortical bone grafts, yet little is known about the process of demineralization and how to control it. The purpose of this study was to investigate the process of cortical bone demineralization by using scanning electron microscopy to evaluate how hydrochloric acid demineralizes cortical bone. Results showed that in the demineralization of diaphyseal cortical bone specimens using hydrochloric acid, a uniformly thick circumferential band of demineralized bone matrix surrounds an inner undecalcified bone core as the process of demineralization occurs. The interface between the demineralized and mineralized section of the bone specimens was extremely sharp. This interface between demineralized and undemineralized bone was noted to advance as a reaction front with increasing demineralization which resulted in continuous shrinkage of the inner cortical bone core. This study suggests that cortical bone demineralization can be best described using an advancing reaction front theory, and this explanation can be used for implementation of the concept of controlled demineralization.

Animals↗

Localization of lipoprotein-delivered benzoporphyrin derivative in the rabbit eye.

PURPOSE: Photodynamic therapy (PDT) using the photosensitizer Benzoporphyrin derivative monoacid (BPD-MA or verteporfin) is currently under investigation for the treatment of choroidal neovascularization. We investigated the localization of this photosensitizer using fluorescence microscopy and quantified its presence in ocular tissues after porphyrin extraction using fluorescence spectroscopy. METHODS: Albino rabbits were administered 2mg/kg BPD-MA pre-complexed with low density lipoprotein (LDL) intravenously, or given no treatment. The eyes were enucleated at intervals between 5 minutes and 24 hours after dye injection and were studied with light and fluorescence microscopy, or dissected for porphyrin extraction. RESULTS: At 5 minutes after dye injection, there was bright fluorescence from the choroid and retinal pigment epithelium (RPE) with trace retinal outer segment fluorescence. After 20 minutes, there was increased photoreceptor outer segment and RPE fluorescence but decreased choroidal fluorescence. By 2 hours no fluorescence remained in either the choroid or the photoreceptors and there was diminished fluorescence of the RPE. Trace RPE fluorescence was still visible at 24 hours. Fluorescence localization of liposomal BPD (2mg/kg) at the earliest (5 minutes) time point was indistinguishable from that of the BPD-LDL complex. Using spectrofluorimetry, the highest BPD-MA levels from the eye were measured in the retina/RPE/uvea complex with lower levels measured from the sclera and other tissues. CONCLUSIONS: BPD-MA with LDL rapidly accumulates in the choroid, RPE, and photoreceptors after intravenous injection. Future studies of PDT with BPD-MA for the treatment of fundus disorders may need to address the relationship between dye localization and photodynamically-mediated injury.

Animals↗

Biodistribution of indocyanine green in a porcine burn model: light and fluorescence microscopy.

BACKGROUND: Infrared-excited fluorescence of intravenously administered indocyanine green (ICG) is being used as a method of early determination of burn depth. METHODS: Fluorescence microscopy and tissue fluorescence were recorded in a porcine burn model and correlated to burn severity and age. RESULTS: Recently placed superficial burns show significant fluorescence compared with adjacent normal tissue as a result of a strong inflammatory reaction in the superficial dermis with minimal vascular occlusion. The magnitude of the inflammatory reaction decreases with time. For deeper burns, vascular occlusion prevents transport of ICG into the burn and the intensity of ICG fluorescence in burn eschar is negligible. CONCLUSION: The intensity of ICG fluorescence measured at the surface of the wound for burns of similar age was shown to decrease exponentially with the depth of the burn. The enhanced fluorescence of partial-thickness burns is attributable to increased permeability, and the decreased signal associated with deeper injuries is attributable to vascular occlusion. These results suggest that it is possible to differentiate burns that will heal spontaneously with minimal granulation from those that will not by measuring the intensity of ICG fluorescence.

Animals↗

Use of the Er:YAG laser for improved plating in maxillofacial surgery: comparison of bone healing in laser and drill osteotomies.

BACKGROUND AND OBJECTIVE: Surgical reconstruction of bony defects in the maxillofacial region involves fixation of bony fragments with mini and micro plates. Bone stabilization during hole drilling is often challenging due to the need to apply pressure when using a conventional mechanical Hall drill. In addition, fragmentation of the fragile bones may occur and complicate the reconstruction. The pulsed Er:YAG laser offers an attractive alternative drilling modality because it does not require physical contact with the bone in order to drill holes, cuts bone with minimal thermal damage, and allows precise control of bone cutting. The objective of this study was to investigate the pulsed Er:YAG laser as an alternative to the mechanical bur by comparing bone healing using both modalities. STUDY DESIGN/MATERIALS AND METHODS: Bone healing in an inferior border defect of the rat mandible was examined using either an Er:YAG laser or a mechanical bur for drilling. The healing of osteotomies in facial bones and of screw holes for plate stabilization of free bone fragments was studied. RESULTS: All defects healed by 4 weeks postoperatively. Histologic evaluation demonstrated no difference in the amount of newly formed woven bone at the osteotomy site or screw holes made by either the laser or the drill. The extent of thermal damage at the osteotomy sites was comparable in laser and mechanically cut bone fragments. CONCLUSIONS: On the basis of this study we suggest that the Er: YAG laser can be used clinically in thin, fragile bones in the maxillofacial region.

Aluminum Silicates↗

Kinetics of cortical bone demineralization: controlled demineralization--a new method for modifying cortical bone allografts.

We investigated the kinetics of hydrochloric acid demineralization of human cortical bone with the objective of developing a method of controlled demineralization for structural bone allografts. It is known that the demineralization of cortical bone is a diffusion rate limited process with a sharp advancing reaction front. The demineralization kinetics of human cortical bone, described as the advance of the reaction front versus immersion time, were determined by measuring extraction of bone mineral in both planar and cylindrical geometries. Mathematical models based on diffusional mass transfer were developed to predict this process. The experimental data fit well with the behavior predicted by the model. The model for planar geometry is applicable to controlled demineralization of cortical bone allografts of irregular shapes such as cortical struts. The model for cylindrical geometry is appropriate when curved surfaces are involved such as in diaphyseal bone allografts. This method of demineralization has direct application to clinical modification of cortical bone allografts to potentially enhance their osteoinductive properties.

Adult↗

Effect of Er:YAG laser holes on osteoinduction in demineralized rat calvarial allografts.

Massive cortical autografts and allografts have been found to incorporate into host bone very slowly and thus are subject to complications such as fatigue fracture and infection. In order to understand and improve the process of osteogenesis in these types of bone grafts, a new experimental model was developed using bone discs from rat calvaria prepared by demineralization and drilling of 0.5 mm diameter holes with a pulsed, 2.94 microns wavelength Erbium:Yttrium-Aluminum-Garnet laser. Four types of bone discs were analyzed: untreated (Type I), demineralized (Type II), laser-ablated (Type III), and laser-ablated then demineralized (Type IV). The discs were transplanted into a subcutaneous site in adult Sprague-Dawley rats and followed for as long as 6 weeks. Histologic analysis of the discs at weekly intervals with use of hematoxylin and eosin staining confirmed the presence of new bone growth in Type-II and Type-IV discs. The amount of new bone growth in each disc was estimated by determining the mineral x-ray attenuation coefficient, which is proportional to mineral density, from digitized radiographs of the discs. The results showed that the processes of demineralization (P < 0.001) and laser ablation with demineralization (p < 0.05) were both significant in enhancing new bone growth in this model. This study demonstrated that osteoinduction can be fostered in cortical bone through the processes of demineralization and laser ablation. To the extent that laser ablation may allow maintenance of structural integrity while altering the surface geometry in such a way as to promote ingrowth of new bone, this experimental model represents an advance in understanding how osteogenesis in cortical bone grafts might be improved.

Animals↗