PubMed Health⌕ Search

Biomedical subjects

K Terajima

Publications and source records attributed to K Terajima.

11 recordsLinked to original sources

[Development of new hydrophilic catheter kit for self-catheterization: study in pediatric cases].

PURPOSE: To increase the management of self-catheterization in children of school age, a catheter kit consisting of hydrophilic catheter and a packet containing sterilized water was developed. We evaluated the lubricating characteristic and clinical efficacy of this new catheter kit. MATERIALS AND METHODS: The catheter kit used in the study was a pocket-size plastic container in which a polyurethane catheter coated with hydrophilic polymer and a packet containing sterilized water were packed in combination. The lubricating characteristic of catheter was assessed by the measurement of friction value. For clinical assessment, male children aged over 6 years old who were doing self-catheterization at 17 medical institutions nationwide were selected as the subjects. The 32 children who had given informed consent (mean age: 11.6 years old) were asked to use the catheter kit continuously for 1 week. The results were investigated by a questionnaire survey in which the assessment before and after the use was expressed in scores. At the same time, urinalysis and urine culture were examined. RESULTS: The friction value of hydrophilic catheter was equivalent to or less than that observed by applying a lubricant to the conventional catheter. The comparison of conventional catheter with the kit indicated significantly higher scores (assessment in 5 grades expressed in scores) for the portability and operability of the kit. Though there was no significant difference in the ease of insertion between the two catheters, there were several comments that the kit got stuck in the urethra when it was withdrawn. The global assessment gave a significantly higher score to the kit and 30 (94%) of the 32 children wanted to use the kit continuously. No increase in hematuria which caused a clinical problem or no new apparent urinary tract infection occurred after the use of the kit. CONCLUSIONS: Compared with the conventional catheter, the hydrophilic catheter kit highly satisfied a large number of children at the time of self-catheterization. Depending on the condition of children, the kit is considered useful for continued self-catheterization for a long term.

Child↗

Minor cardiac troponin T release in patients undergoing coronary artery bypass graft surgery on a beating heart.

OBJECTIVES: To determine whether and to what extent coronary artery bypass graft (CABG) surgery without extracorporeal circulation is associated with cardiac troponin T (TnT) release. DESIGN: Prospective study. SETTING: A single university hospital. PARTICIPANTS: Twenty-three patients scheduled for minimally invasive CABG surgery. Sixteen patients received one coronary anastomosis, and seven received two. INTERVENTIONS: TnT and creatine kinase-MB (CK-MB) levels were determined immediately before induction of anesthesia (baseline) and at 0, 12, and 24 hours after surgery. Hemodynamic measurements were made, and 5-lead electrocardiograms with continuous automated ST-segment trends were analyzed. MEASUREMENTS AND MAIN RESULTS: All patients had a good cardiac outcome. Median cumulative coronary artery occlusion time was 27 minutes (range, 10 to 49 minutes). TnT levels were undetectable in 91.3% of patients at baseline when a detection limit of 0.01 ng/mL was employed. TnT and CK-MB showed significant elevations at 12 and 24 hours versus baseline. Postoperatively, TnT was detectable in 91.3% of patients, and 17.4% suffered minor myocardial damage, as evidenced by an abnormal increase in TnT greater than 0.2 ng/mL, excluding those exhibiting myocardial infarction. ST segment changes developed in seven patients, persisting for 13.0 minutes (range, 9.5 to 15.8 minutes) and disappearing immediately after coronary artery clamp release. There were no significant correlations between cumulative coronary occlusion time and peak TnT or CK-MB levels. CONCLUSIONS: TnT was detected after surgery in most patients, and significant TnT levels indicative of myocardial injury (>0.2 ng/mL) were detected in only 17% of patients, probably as a result of brief periods of coronary artery occlusion.

Adult↗

Myocardial dysfunction associated with proinflammatory cytokines after esophageal resection.

UNLABELLED: Proinflammatory cytokines have been implicated in mediating myocardial dysfunction associated with major surgery. We investigated the profile of proinflammatory cytokines and the association of cytokine levels with myocardial function after esophagectomy. We studied 12 patients who underwent subtotal esophagectomy. One patient died of multiple organ failure. This patient had the largest interleukin-6 (IL-6) level of all the subjects. IL-6 levels increased from 14.9 +/- 8.7 pg/mL to 498.4 +/- 294.3 pg/mL (P < 0.05) at 6 h postoperatively. Interleukin-8 (IL-8) levels also significantly increased postoperatively. Right ventricular ejection fraction (RVEF) decreased from 44% +/- 1% to 36% +/- 2% (P < 0.05) and 37% +/- 2% (P < 0.05) at 6 h and 12 h postoperatively. Stroke volume index (SVI) decreased significantly at the end of operation and at 6 h and 12 h postoperatively. The changes of RVEF and SVI showed an independent negative correlation with the IL-6 level (r = -0.70, P < 0.001 and r = -0.62, P < 0.001, respectively). In contrast, the change of RVEF and SVI was not correlated with the IL-8 level. Esophagectomy is associated with transient depression of myocardial function. IL-6 may contribute to this postoperative myocardial dysfunction. IMPLICATIONS: We examined the association between myocardial function and proinflammatory cytokines after esophagectomy. Interleukin-6 may be the cytokine that most sensitively reflects the postoperative myocardial dysfunction.

Carcinoma, Squamous Cell↗

Joint proprioception in the elderly with and without hip fracture.

OBJECTIVES: Decreased proprioception may contribute to the risk of falls in elderly patients. The purpose of this study is to determine whether patients with hip fractures have decreased hip proprioception compared with aged-matched controls, and whether hip proprioception differs in patients with repaired fractures compared with patients who have undergone prosthetic hip replacement after hip fracture. DESIGN: Retrospective. PATIENTS/PARTICIPANTS: Both hips of twenty-four hip fracture patients and age-matched patients without hip fractures were studied. Hip fracture patients were divided into osteosynthesis (twelve hips) and hemiarthroplasty (twelve hips) groups. INTERVENTION: Reproducibility of index angles (thirty hip flexion and thirty hip abduction) were compared with a six-degree-of-freedom electrogoniometer (instrumented spatial linkage; angular accuracy +/-0.5 degrees). RESULTS: There was no significant difference (flexion, p > 0.20; abduction, p > 0.67) in joint proprioception between fracture and no fracture groups. Likewise, there was no difference (flexion, p > 0.99, abduction; p > 0.74) in joint proprioception between osteosynthesis and hemiarthroplasty groups. CONCLUSIONS: Joint proprioception of hip fracture patients was not found to be diminished compared with age-matched normal controls. Additionally, replacement of the femoral head did not reduce joint proprioception compared with osteosynthesis with an intact femoral head. Maintenance of the femoral head does not seem to be necessary for the maintenance of joint proprioception in elderly hip fracture patients.

Aged↗

Intracapsular components do not change hip proprioception.

We compared joint proprioception in 12 hips in 12 patients with hemiarthroplasty after fracture of the hip, in 12 hips in 11 patients with total hip arthroplasty because of osteoarthritis and in a control group of 12 age-matched patients with no clinical complaints. There was no significant difference (p = 0.05) in joint proprioception in any of the groups. There was no decrease in joint proprioception in the group with total hip arthroplasty compared with the hemiarthroplasty group or with the control group. Other factors such as stretch receptors in the adjacent tendons and muscles may have a greater influence on proprioception in the hip than the intracapsular components.

Aged↗

Screw home motion after total knee replacement.

The objective of this study was to evaluate the effect of muscle force and the posterior cruciate ligament on screw home motion in patients with total knee replacement in a posterior cruciate ligament retaining prosthesis (10 knees) and a posterior cruciate ligament substituting prosthesis (10 knees). Screw home motion was examined with only active extension and with two types of externally loaded active extension (2 kg and body weight). Screw home motion was measured with a 6 degrees of freedom electrogoniometer (instrumented spatial linkage). Retaining the posterior cruciate ligament maintained screw home motion, with and without external load to muscles, whereas substituting the posterior cruciate ligament maintained screw home motion only under the full external load of body weight. This was not seen with a 2-kg external load. As for the normal knee, it appears that screw home motion of a prosthetic knee is influenced, not only by the presence of ligamentous structures, but also by the activity of the muscles. The activity of the muscles may have a much greater effect on screw home motion with currently used prosthetic designs than does the presence of ligamentous structures.

Aged↗

Gait analysis after total knee arthroplasty. Comparison of posterior cruciate retention and substitution.

: The objective of this study was to measure three-dimensional knee motion during gait in patients with total knee replacements which either retained the posterior cruciate ligament (n = 11), or required sacrifice of the posterior cruciate ligament and replacement of its function with a posterior stabilizing articular surface (n = 9). Clinically meaningful translations (anterior and posterior, medial and lateral, proximal and distal) and rotations (flexion and extension, internal and external rotation, abduction and adduction) were measured using an instrumented spatial linkage. Although patients from both groups were able to achieve passive full extension and a minimum of 95 degrees flexion, some of their translations and rotations during free speed walking were consistently less than those in a group of healthy controls. Motion during the swing phase of gait was similar for both knee replacement groups. However, abduction and adduction and proximal and distal translation were larger (but neither difference was significant) for the patients with implants with a posterior stabilizing surface, which suggests that the stabilizing surface may not reliably provide as much stability in these directions as does retention of the posterior cruciate ligament.

Aged↗

Comparison of joint position sense after total knee arthroplasty.

A comparison of joint position sense, determined by reproducibility of index angles and their subsequent change, was performed in 55 knees that had undergoing a semiconstrained total knee arthroplasty. Knees were stratified into groups that represented arthroplasties performed with or without posterior cruciate ligament retention, with or without resurfacing of the patella, and with or without cement for fixation. There was no significant difference in joint position sense among all the arthroplasty groups. Likewise, there was no difference in joint position sense between any of the arthroplasty groups and an age-matched control group of 32 knees in 32 patients who had not previously undergoing a total knee arthroplasty. Knee arthroplasty does not affect joint position sense.

Aged↗

Three-dimensional kinematics of the human knee with intracortical pin fixation.

Knee motion was measured with an instrumented spatial linkage (accuracy, linear +/-500 microns; angular, +/-0.5 degree) fixed with intracortical Kirschner wires in five healthy male volunteers (five knees, judged clinically to be normal). This technique allows an accurate description of the relative angular and linear movements between tibia and femur without the effect of skin movement relative to the bone and without the effect of changing muscle volume. Motion of the tibia relative to the femur was described in terms of three clinically meaningful rotations and three translations between full extension and 60 degrees flexion: (1) abduction and adduction: 3.4 degrees +/- 1.2 degrees; (2) internal and external rotation: 10.6 degrees +/- 2.8 degrees, representing screw home motion; (3) anterior and posterior: 5.2 +/- 1.7 mm, representing roll back phenomenon; (4) proximal and distal: 1.2 +/- 2.7 mm; and (5) medial and lateral: 1.1 +/- 2.6 mm.

Adult↗