PubMed HealthSearch

Biomedical subjects

K Terayama

Publications and source records attributed to K Terayama.

At least 19 recordsLinked to original sources

Molecular cloning and expression of a second glucuronyltransferase involved in the biosynthesis of the HNK-1 carbohydrate epitope.

A cDNA encoding a novel glucuronyltransferase was cloned from a rat brain cDNA library. The cDNA sequence contained an open reading frame encoding 324 amino acids, with type II transmembrane topology. The amino acid sequence revealed 49% homology to rat GlcAT-P, a glucuronyltransferase involved in the biosynthesis of the HNK-1 carbohydrate epitope of glycoproteins, [Terayama et al. (1997) Proc. Natl. Acad. Sci. USA 94, 6093-6098] and the highest sequence homology was found in the catalytic region. Northern blot analysis indicated that this newly cloned glucuronyltransferase is expressed in the nervous system, consistent with the selective localization of the HNK-1 carbohydrate epitope in the nervous system. Transfection of this cDNA into COS-1 cells induced the expression of the HNK-1 carbohydrate epitope on cell surfaces, and induced the morphological changes in these cells. These results indicated that this newly cloned cDNA is a second glucuronyltransferase involved in the biosynthesis of the HNK-1 carbohydrate epitope.

Amino Acid Sequence

Purification and characterization of a glucuronyltransferase involved in the biosynthesis of the HNK-1 epitope on glycoproteins from rat brain.

The glucuronyltransferase involved in the biosynthesis of the HNK-1 epitope on glycoproteins was purified to an apparent homogeneity from the Nonidet P-40 extract of 2-week postnatal rat forebrain by sequential chromatographies on CM-Sepharose CL-6B, UDP-GlcA-Sepharose 4B, asialo-orosomucoid-Sepharose 4B, Matrex gel Blue A, Mono Q, HiTrap chelating, and HiTrap heparin columns. The purified enzyme migrated as a 45-kDa protein upon SDS-polyacrylamide gel electrophoresis under reducing conditions, but eluted as a 90-kDa protein upon Superose gel filtration in the presence of Nonidet P-40, suggesting that the enzyme forms homodimers under non-denatured conditions. The enzyme transferred glucuronic acid to various glycoprotein acceptors bearing terminal N-acetyllactosamine structure such as asialo-orosomucoid, asialo-fetuin, and asialo-neural cell adhesion molecule, whereas little activity was detected to paragloboside, a precursor glycolipid of the HNK-1 epitope on glycolipids. These results suggested that the enzyme is specifically associated with the biosynthesis of the HNK-1 epitope on glycoproteins. Sphingomyelin was specifically required for expression of the enzyme activity. Stearoyl-sphingomyelin (18:0) was the most effective, followed by palmitoyl-sphingomyelin (16:0) and lignoceroyl-sphingomyelin (24:0). Interestingly, activity was demonstrated only for sphingomyelin with a saturated fatty acid, i.e. not for that with an unsaturated fatty acid, regardless of the length of the acyl group.

Animals

Sarcomatoid renal cell carcinoma with chromophobe cell foci. Report of a case.

We report a case of sarcomatoid renal cell carcinoma with chromophobe cell foci. The patient was a 57-year-old Japanese woman with a renal mass measuring 12x8x8 cm in diameter. Histologically, the tumor was composed predominantly of sarcomatoid renal cell carcinoma with foci of chromophobe cell carcinoma. The patient died of multiple metastases 2 months after operation. To the best of our knowledge, there have been only two reports of the coexistence of sarcomatoid renal cell carcinoma and chromophobe renal cell carcinoma in the literature. Our case indicates that chromophobe cell carcinoma may be connected with sarcomatoid renal cell carcinoma. In such a case, the prognosis may be related to the latter component.

Adenocarcinoma

Cloning and functional expression of a novel glucuronyltransferase involved in the biosynthesis of the carbohydrate epitope HNK-1.

The HNK-1 carbohydrate epitope is characteristically expressed on a series of cell adhesion molecules and also on some glycolipids in the nervous system over a wide range of species from insect to mammal. The HNK-1 epitope is involved in cell-cell and/or cell-substrate interaction and recognition during the development of the nervous system. In this study, we isolated a novel glucuronyltransferase from rat brain, which is a key enzyme of the biosynthesis of the HNK-1 epitope on glycoproteins. Based on the partial amino acid sequences, we isolated cDNA encoding the glucuronyltransferase. The primary structure deduced from the cDNA sequence predicted a type II transmembrane protein with 347 amino acids and had no detectable similarity with any other proteins of known functions, including glucuronyltransferases of the liver and olfactory epithelium. Expression of a soluble recombinant form of the enzyme in COS-1 cells produced an active glucuronyltransferase. The selective expression of the glucuronyltransferase gene in the nervous system was consistent with the almost exclusive localization of the HNK-1 epitope in the nervous system. Transfection of the glucuronyltransferase cDNA into COS-1 cells induced not only expression of the HNK-1 epitope on the cell surface but also marked morphological changes of the cells, suggesting that the HNK-1 epitope associates with the cell-substratum interaction.

Amino Acid Sequence

Papillary carcinoma of the thyroid with exuberant nodular fasciitis-like stroma.

We describe a rare case of papillary carcinoma with extensive proliferation of stromal cells. The stromal cells were immunocytochemically positive for vimentin, alpha-smooth muscle actin and desmin, but negative for cytokeratin, epithelial membrane antigen, S-100, thyroglobulin and CD34. These results and the ultrastructure of the stromal cells, which exhibited the characteristics of both fibroblasts and smooth muscle cells, indicated an origin from myofibroblasts. We conclude that myofibroblastic proliferation may contribute to the stromal response in the slow growth of the papillary carcinoma.

Carcinoma, Papillary

Comparative study of total hip arthroplasty between younger and older patients.

Ten- to 20-year (average, 14 years) results of primary Charnley low friction arthroplasties performed in patients 50 years of age or younger (55 sockets and 53 femoral prostheses) were compared with those in patients older than 50 years (273 sockets and 273 femoral prostheses). The incidence of radiologic loosening of the socket, including revision cases, was higher in the younger (29.1%) than in the older patients (14.3%). The revision rate for aseptic loosening of the socket was higher in the younger (20%) than in the older group (4%). This poor performance of the socket may be attributable to the higher incidences of rheumatoid diseases and accelerated polyethylene wear in the younger patients. In contrast, only 3.8% of the femoral prostheses were radiologically loose, and none of them were revised in the younger patients. These figures were comparable with those in the older patients. Quality of structure of bone available for implant fixation may be important for the durability of the arthroplasty. It was considered inferior on the acetabular side and better on the femoral side in the younger patients than in the older. Continued use of the cemented Charnley femoral prostheses can be justified in young patients, although further research is required for the socket problem.

Adolescent

Long term bone remodeling around the Charnley femoral prostheses.

Femoral bone remodeling after total hip replacement was studied by following patients who received 326 Charnley femoral prostheses for 10 to 20 years (mean, 13.3 years). The radiographic state of the bone remodeling was visually assessed and measured with a digitizer. Demineralization that started proximally and then progressed distally caused cortical thinning, which correlated with widening of the intramedullary canal, not with changes that developed in the periosteal width, and occurred in the medial femoral neck, around the proximal half of the stem, and around the distal half in 87%, 33%, and 10%, respectively. Cortical thinning around the distal half of the stem was always accompanied by proximal thinning, and extensive cortical thinning (both proximal and distal) correlated with both lower clinical scores and radiologic loosening of the femoral prosthesis. A low canal flare index of Noble, a large canal width, and a patient age of 60 years or more were risk factors for extensive cortical thinning. Accelerated polyethylene wear was related to resorption of the medial femoral neck but not to cortical thinning or radiological loosening. Cortical thickening occurred only around the distal half of the stem in 29%. These findings establish a basis for the performance of cemented femoral prostheses, and allow comparison of bone remodeling when evaluating other femoral prostheses.

Adolescent

Hydroxyapatite clay for gap filling and adequate bone ingrowth.

In uncemented total hip arthroplasty, a complete filling of the gap between femoral prosthesis and the host bone is difficult and defects would remain, because the anatomy of the reamed intramedullary canal cannot fit the prosthesis. Therefore, it seems practical to fill the gap with a clay containing hydroxyapatite (HA), which has an osteoconductive character. The clay (HA clay) is made by mixing HA granules (size 0.1 mm or more) having a homogeneous pore distribution and a porosity of 35-48 vol%, and a viscous substance such as a saline solution of sodium alginate (SSSA). In the first experiment, the ratio of HA granules and sodium alginate in SSSA is set for the same handling properties of HA clay and polymethylmethacrylate bone cement (standard viscosity) before hardening. As a result, the ratio is set for 55 wt% of HA in the clay and 12.5 wt% of sodium alginate in SSSA (i.e., HA:sodium alginate:saline solution = 9.8:1:7). In the second study, the gap between the femoral stem and bone model is completely filled with HA clay. However, the gap is not filled only with HA granules or HA granules mixed with saline solution. In the third animal experiment, using an unloaded model, histology shows that HA clay has an osteoconductive property bridging the gap between the implant and the cortical bone without any adverse reaction. HA clay is considered a useful biomaterial to fill the gap with adequate bone ingrowth.

Animals

Effects of various types of extracellular matrices on adhesion, proliferation, differentiation, and c-fos protein expression of porcine thyroid follicle cells.

Thyroid follicles in vivo are embedded in extracellular matrix (ECM). The composing epithelial cells are in close contact with ECM at the basal side. To examine cell-to-ECM interactions, we studied adhesion, proliferation and differentiation of porcine follicle cells monolayer-cultured on type I and IV collagen, fibronectin or laminin. At 3 h in culture, laminin had the lowest rate of cell adhesion. In proliferation, type IV collagen induced the highest level of nuclear bromodeoxyuridine intake. In a functional differentiation, laminin had about 3 times as much triiodothyronine production as the other ECM molecules. In confluent culture cells, we also examined an expression of c-fos protein, a transcription factor that plays crucial roles in signal transduction. Immunocytochemistry detected the protein mainly in the nuclei. Western blot showed that laminin induced the highest level of its expression. Thyrotropin (TSH, 10 mU/ml) did not affect adhesion of the cells on any of the substrata or proliferation of the cells on fibronectin; nor did TSH affect c-fos protein expression of the cells on the substrata except for fibronectin. Our results suggest that type IV collagen and laminin, major components of basement membrane, play positive roles in proliferation and differentiation of follicle cells, respectively, while laminin has no positive effect on adhesion of the cells at early culture; that the cells express c-fos protein even in contact inhibition of growth and its expression is regulated in part by ECM; and that ECM controls some behaviors of the cells in a TSH-dependent or TSH-independent manner.

Animals

Decrease in surface charge density of Klebsiella pneumoniae treated with cefodizime and enhancement of the phagocytic function of human polymorphonuclear leucocytes stimulated by the drug-treated bacteria.

Treatment of Klebsiella pneumoniae 109 with cefodizime, ceftazidime, cefbuperazone, cefotaxime or flomoxef at a sub-minimum inhibitory concentration (sub-MIC) (1/4 MIC) for 1 h altered its morphology. The bacteria treated with cefodizime at sub-MICs (1/8, 1/4 MIC) enhanced the chemiluminescencence (CL) of human polymorphonuclear leucocytes (PMNs), implying an increase in the production of active oxygen species in association with phagocytosis, whereas the cells treated with other cephalosporins at the same sub-MICs did not. Furthermore, a significant decrease in electrophoretic mobility was induced by the bacteria treated with cefodizime at sub-MICs (1/8, 1/4 MIC), but other cephalosporins neither increased nor decreased the electrophoretic mobility significantly. These findings suggested that cefodizime caused a morphological change, with a decrease in negative surface charge density of K. pneumoniae, more easily than ceftazidime, cefbuperazone, cefotaxime or flomoxef, followed by an increase in the phagocytic activity of PMNs.

Cefotaxime

A rare case of primary pulmonary choriocarcinoma in a male: immunohistochemical detection for human chorionic gonadotropin, epidermal growth factor (EGF) and EGF-receptor.

a rare case of primary choriocarcinoma of the lung in a male is described with immunohistochemistry for human chorionic gonadotropin (hCG), epidermal growth factor (EGF) and EGF-receptor. The extragonadal trophoblastic origin of this pulmonary carcinoma was definitely confirmed by an autopsy examination, and hCG-production and hCG-positive staining of the tumor cells. Furthermore, the tumor cells clearly expressed EGF and its receptor which play an important role in the proliferation and differentiation of normal and neoplastic trophoblasts of the uterus. Our present case suggests that EGF may act in an autocrine manner in the tumor cells of primary pulmonary choriocarcinoma.

Aged

Fracture of the tibial tray following PCA knee replacement. A report of two cases.

We report two cases in which fracture of the tibial metal tray was thought to be due to improper design of the tray and heavy polyethylene wear. The bone beneath the fractured portion of the tray was deficient and had been replaced by granulomatous fibrous tissue including numerous polyethylene wear particles and foreign-body giant cells. Osteolysis occurred as a tissue reaction to these particles.

Aged

Arthroscopic reduction and fixation of a completely displaced fracture of the intercondylar eminence of the tibia.

A simple method of arthroscopic reduction and fixation of a fracture of the intercondylar eminence of the tibia is described. A 23-year-old man with a completely displaced (Type IIIB) fracture was treated with arthroscopy. A satisfactory reduction was achieved by releasing the medial meniscus, which was entrapped in the fracture site. Link dynamic staples (W. Link, Hamburg, Germany) were used to firmly fix the fracture when the guide tube came downward from the medial mid-patellar portal. The secure fixation of the fragment and the prevention of the need for an arthrotomy facilitated early functional rehabilitation. One year after surgery the patient had a stable, painless joint with a full range of motion. The described method is technically straight-forward and can provide secure fixation of a bone fragment. The Link staples are useful in the fixation of a displaced fracture of the intercondylar eminence of the tibia.

Adult

Predisposing factors in fixation failure of femoral prostheses following primary Charnley low friction arthroplasty. A 10- to 20-year followup study.

To identify factors affecting radiologically detected loosening of the Charnley femoral prosthesis, 326 femoral prostheses with 10- to 20-year followup were studied. After observation of postoperative radiological changes, the criteria for fixation failure detected radiologically, of femoral prostheses were defined as progression or accompanying occurrences of subsidence, demarcation, separation of the prosthesis from cement, cement fracture, or endosteal cavitation. Sixteen femoral prostheses (4.9%) developed radiologically detected fixation failure. Male gender, low canal flare index, low femoral score, large medullary canal width, low implant (cement and stem)/canal ratio, low stem/canal ratio, and varus orientation of the stem affected fixation failure. Inadequate cementing techniques such as low implant/canal and stem/canal ratios and varus stem orientation might be within the surgeon's control and should be avoided. An unfavorable canal geometry (stovepipe canal) and osteopenia of the femur, indicated by a low femoral score, are risk factors that might be out of the surgeon's control, and require future research.

Activities of Daily Living

Risk factors affecting radiological failure of the socket in primary Charnley low friction arthroplasty. A 10- to 20-year followup study.

To identify the factors affecting Hodgkinson Type 3 or 4 radiological demarcation (presence of complete demarcation or migration, respectively) of the Charnley socket, 328 sockets with 10- to 20-year followup were studied. Fifty-five sockets (16.8%) developed Type 3 or 4 demarcation. In the osteoarthrosis group (237 sockets), removal of eburnated bone at the acetabular roof, the presence of large acetabular angles before and after surgery, and high placement of the socket were related to development of Type 3 or 4 demarcation. In the rheumatoid group (32 sockets), young patient age predisposed the socket to Type 3 or 4 demarcation. Rapid polyethylene wear, correlated with young age, male gender, and thin cement mantle in Zones I and II, was another important factor related to Type 3 or 4 demarcation in both groups and in the entire series. These risk factors should be taken into account when assessing the indications for arthroplasty, when performing arthroplasty, and when educating the patient.

Acetabulum

Factors influencing survival of the socket after primary low-friction arthroplasty of the hip.

Two hundred and sixty-seven consecutive primary low-friction arthroplasties, followed for 5 to 18 years after surgery, were studied to assess the factors influencing survival of the socket, using the Kaplan-Meier method. The end point of survival was defined radiologically in two ways: incipient failure (migration of 3 mm or more or rotation of 4 degrees or more) and definite failure (progressive change of position). Twenty-four sockets (9.0%) developed incipient failure, and 14 of them progressed to definite failure. Preservation of the subchondral bone plate or eburnated bone in the acetabular roof, multiple 6-mm anchor holes, and two steps of evolution in socket design (the advent of a pressure-injection socket and than an ogee-flanged socket) benefited socket survival. Polyethylene wear was considered to be the most important factor limiting longevity of the socket.

Adult

Quantitative stress radiography for diagnosis of anterior cruciate ligament deficiency. Comparison between manual and instrumental techniques and between methods with knee flexed at 20 degrees and at 90 degrees.

A portable stress-applying device for stress radiography was developed for daily clinical use. Using this device, stress radiography for the diagnosis of the anterior cruciate ligament (ACL) deficiency was performed with the knee flexed at 20 degrees and at 90 degrees. A 100-N force was chosen as a standardized stress. The subjects were classified into four groups: the manually tested ACL-deficient group (32 knees), the manually tested control group (80 knees), the instrumentally tested ACL-deficient group (14 knees), and the instrumentally tested control group (34 knees). There was no statistical difference in the reliability (sensitivity, specificity, and accuracy) of stress radiography between the manual technique and the instrumental technique. When stress radiography with the knee flexed at 20 degrees and that at 90 degrees were compared, the former was more reliable than the latter. As the manual technique is compromised by a lack of standardization in applied force, a mechanical device is required in quantitative stress radiography. The reliability of stress radiography with the knee flexed at 20 degrees is considered high enough to warrant dispensing with further stress radiography with the knee flexed at 90 degrees for diagnosing ACL deficiency.

Anterior Cruciate Ligament