PubMed Health⌕ Search

Biomedical subjects

K Visscher

Publications and source records attributed to K Visscher.

8 recordsLinked to original sources

Force production by single kinesin motors.

Motor proteins such as kinesin, myosin and polymerase convert chemical energy into work through a cycle that involves nucleotide hydrolysis. Kinetic rates in the cycle that depend upon load identify transitions at which structural changes, such as power strokes or diffusive motions, are likely to occur. Here we show, by modelling data obtained with a molecular force clamp, that kinesin mechanochemistry can be characterized by a mechanism in which a load-dependent isomerization follows ATP binding. This model quantitatively accounts for velocity data over a wide range of loads and ATP levels, and indicates that movement may be accomplished through two sequential 4-nm substeps. Similar considerations account for kinesin processivity, which is found to obey a load-dependent Michaelis-Menten relationship.

Adenosine Triphosphate↗

Single kinesin molecules studied with a molecular force clamp.

Kinesin is a two-headed, ATP-driven motor protein that moves processively along microtubules in discrete steps of 8 nm, probably by advancing each of its heads alternately in sequence. Molecular details of how the chemical energy stored in ATP is coupled to mechanical displacement remain obscure. To shed light on this question, a force clamp was constructed, based on a feedback-driven optical trap capable of maintaining constant loads on single kinesin motors. The instrument provides unprecedented resolution of molecular motion and permits mechanochemical studies under controlled external loads. Analysis of records of kinesin motion under variable ATP concentrations and loads revealed several new features. First, kinesin stepping appears to be tightly coupled to ATP hydrolysis over a wide range of forces, with a single hydrolysis per 8-nm mechanical advance. Second, the kinesin stall force depends on the ATP concentration. Third, increased loads reduce the maximum velocity as expected, but also raise the apparent Michaelis-Menten constant. The kinesin cycle therefore contains at least one load-dependent transition affecting the rate at which ATP molecules bind and subsequently commit to hydrolysis. It is likely that at least one other load-dependent rate exists, affecting turnover number. Together, these findings will necessitate revisions to our understanding of how kinesin motors function.

Adenosine Triphosphate↗

Direct energy transfer from the peripheral LH2 antenna to the reaction center in a mutant of Rhodobacter sphaeroides that lacks the core LH1 antenna.

The light-harvesting apparatus of the photosynthetic bacterium Rhodobacter sphaeroides is composed of a peripheral LH2 complex which directs excitation energy to the LH1/reaction center core. The puf BA genes encoding the LH1 polypeptides have been deleted, producing a photosynthetically-competent strain which contains LH2 and reaction centers. Time-resolved absorption and fluorescence measurements demonstrate that energy is efficiently transferred from LH2 to the reaction center, despite the absence of LH1. Energy trapping takes place in 55 +/- 5 ps at room temperature, compared to the result for the wild-type strain of 60 +/- 5 ps. At 77 K, the results for the mutant and wild type are 75 +/- 5 and approximately 35 ps, respectively; the slower time in the mutant is attributed to the small differences in antenna/reaction center contacts and relative distances that are bound to exist as a consequence of LH1 and LH2 being assembled from different alpha- and beta-polypeptides. Measurements with closed reaction centers provided new information on the nature of fast energy transfer within the B850 pigments of LH2. We conclude that the absorption band is inhomogeneously broadened, and the fast (approximately 10 ps) lifetime observed in the 847-857-nm region is interpreted as very rapid (1-5 ps) hopping of the excitation energy from high-energy to low-energy pigments within the B850 absorption band. Time-resolved anisotropy studies demonstrate that energy-transfer events within B850 occur on a subpicosecond to picosecond time scale.(ABSTRACT TRUNCATED AT 250 WORDS)

Energy Transfer↗

Micromanipulation by "multiple" optical traps created by a single fast scanning trap integrated with the bilateral confocal scanning laser microscope.

We have developed a novel micromanipulator consisting of multiple optical traps created by scanning one single beam trap along a variable number of positions. Among other things, this enables the orientation of irregularly shaped and relatively large structures which could not be oriented by just one trap as is demonstrated on long Escherichia coli bacteria filaments. We expect that the multiple trap manipulator will broaden the field of applications of optical trapping as a micromanipulation technique. For example, it facilitates the study of mechanical properties of extended structures as illustrated by a "bending"-experiment using E. coli bacterium filaments. A special application of the multiple trap manipulator is the "indirect trapping" of objects which we did by keeping them held between other optically trapped particles. Indirect trapping makes it possible to trap particles which either cannot be trapped directly due to their optical properties (refractive index) or for which exposure to the laser radiation is undesirable. The multiple optical trap manipulator is controlled interactively by a UNIX workstation coupled to a VME instrumentation bus. This provides great flexibility in the control of the position and the orientation of the optical traps. Micromanipulation makes it desirable to have real time 3D microscopy for imaging and guidance of the optical traps. Therefore we integrated optical micromanipulation and a specially developed real-time confocal microscope. This so called bilateral confocal scanning laser microscope (bilateral CSLM) [Brakenhoff and Visscher, J Microsc 165:139-146, 1992] produces images at video rate.

Lasers↗

Isolation of single yeast cells by optical trapping.

Individual yeast cells can be successfully isolated and recultured on plates with a new isolation method making use of optical trapping with infrared laser light. The cells can be selected on morphological criteria by high resolution microscopy. The isolation device is constructed from two coverslips separated by spacers, in which selected cells are transferred to a plastic capillary, using the optical trap. To test the procedure, selection experiments were done with a mixture of two Saccharomyces cerevisiae strains, distinguishable both in fluorescence microscopy and on agar plates. These experiments showed that only selected cells were isolated, and close to 100% of the isolated stationary-phase cells formed colonies on agar plates, indicating a high recovery. A lower recovery was obtained with exponential-phase cells, possibly because of a higher sensitivity to laser irradiation. Applications for this method may include the isolation of mutants with altered morphology and the isolation of subpopulations of yeast cultures, for their separate investigation or for the initiation of pure cultures.

Infrared Rays↗

Single beam optical trapping integrated in a confocal microscope for biological applications.

Confocal microscopy is very useful in biology because of its three dimensional imaging capacities and has proven to be an excellent tool to study the 3D organization of, for instance, cell structures. This property of confocal microscopy makes it also very suitable for observation during guidance of the three dimensional manipulation of single cells or cell elements. Therefore we decided to integrate a confocal microscope and a single beam optical manipulator into a single instrument. The advantage of optical manipulation over mechanical techniques is that it is non-invasive and therefore may be applied on living (micro-) organisms and cells. The creation of an effective single beam optical trap requires the use of a high numerical aperture (N.A.) objective to focus the laser beam. In this paper we briefly discuss the vertical or axial force exerted on a sphere in a single beam trap. The axial force on a sphere placed on the optical axis, caused by reflection and refraction, is calculated applying a electromagnetic vector diffraction theory to determine the field distribution in the focal region. One of the results is that the particle also experiences a vertical trapping force towards the focusing lens when it is in the strongly convergent part of the field in addition to the known negative signed trapping force in the divergent part of the field. Further we describe an instrumental approach to realize optical trapping in which the optical trap position is controlled by moving the focusing objective only.(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

Four-parameter white blood cell differential counting based on light scattering measurements.

Measurement of the depolarized orthogonal light scattering in flow cytometry enables one to discriminate human eosinophilic granulocytes from neutrophilic granulocytes. We use this method to perform a four-parameter differential white blood cell analysis. A simple flow cytometer was built equipped with a 5-mW helium neon laser that measures simultaneously four light scattering parameters. Lymphocytes, monocytes, and granulocytes were identified by simultaneously measuring the light scattering intensity at angles between 1.0 degrees and 2.6 degrees and angles between 3.0 degrees and 11.0 degrees. Eosinophilic granulocytes were distinguished from neutrophilic granulocytes by simultaneous measurement of the orthogonal and depolarized orthogonal light scattering. Comparison of a white blood cell differentiation of 45 donors obtained by the Technicon H-6000 and our instrument revealed good correlations. The correlation coefficients (r2) found were: 0.99 for lymphocytes, 0.76 for monocytes, 0.99 for neutrophilic granulocytes, and 0.98 for eosinophilic granulocytes. The results demonstrate that reliable white blood cell differentiation of the four most clinically relevant leukocytes can be obtained by measurement of light scattering properties of unstained leukocytes.

Basophils↗