Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection : results and technical considerations.

BACKGROUND: One of the perceived benefits of dual-chamber implantable cardioverter-defibrillators (ICDs) is the reduction in inappropriate therapy due to new detection algorithms. It was the purpose of the present investigation to propose methods to minimize bias during such comparisons and to report the arrhythmia detection clinical results of the PR Logic dual-chamber detection algorithm in the GEM DR ICD in the context of these methods. METHODS AND RESULTS: Between November 1997 and October 1998, 933 patients received the GEM DR ICD in this prospective multicenter study. A total of 4856 sustained arrhythmia episodes (n=311) with stored electrogram and marker channel were classified by the investigators; 3488 episodes (n=232) were ventricular tachycardia (VT)/ventricular fibrillation (VF), and 1368 episodes (n=149) were supraventricular tachycardia (SVT). The overall detection results were corrected for multiple episodes within a patient with the generalized estimating equations (GEE) method with an exchangeable correlation structure between episodes. The relative sensitivity for detection of sustained VT and/or VF was 100.0% (3488 of 3488, n=232; 95% CI 98.3% to 100%), the VT/VF positive predictivity was 88.4% uncorrected (3488 of 3945, n=278) and 78.1% corrected (95% CI 73.3% to 82.3%) with the GEE method, and the SVT positive predictivity was 100.0% (911 of 911, n=101; 95% CI 96% to 100%). CONCLUSIONS: A structured approach to analysis limits the bias inherent in the evaluation of tachycardia discrimination algorithms through the use of relative VT/VF sensitivity, VT/VF positive predictivity, and SVT positive predictivity along with corrections for multiple tachycardia episodes in a single patient.

Algorithms↗

The effects of atrial pacing on the signal-averaged electrocardiogram in patients with coronary artery disease.

The effects of atrial pacing on the signal-averaged electrocardiogram were studied in 14 patients with remote myocardial infarction and a history of cardiac arrest or sustained ventricular tachycardia (group I) and in 13 patients with coronary artery disease and no history of sustained ventricular tachyarrhythmia (group II). Recordings of the signal-averaged electrocardiogram were obtained at control and during atrial pacing at rates of 80, 100, and 120 beats/min. All patients had recordings analyzed from at least two paced rates. At control, the mean high frequency total duration of the QRS complex (HFTD) was significantly longer in group I versus group II patients (123 +/- 5.6 versus 111 +/- 3.5 msec, p less than 0.05). Although the duration of the QRS signal under 40 microV (D40) was higher in group I versus group II patients (42 +/- 4.7 versus 32.4 +/- 3.5 msec) and the root mean square amplitude of the terminal 40 msec QRS (RMSA) was lower in the group I patients (27 +/- 7.5 versus 38.1 +/- 8.8 microV), these differences did not achieve statistical significance. There was no effect of atrial pacing on the measured signal-averaged parameters of HFTD, D40, and RMSA. Although there was a difference between group I and group II at each paced rate analyzed, atrial pacing did not help to further stratify the groups. In patients with coronary artery disease, atrial pacing is not a useful method of stratifying high-risk patients. Changes in serial signal-averaged electrocardiograms from the same patient are not due to heart rate variability.

Aged↗