The role of preoperative bone scan for determining the treatment method for femoral neck fracture.

To evaluate the role of preoperative bone scintigraphy in determining the operative treatment method for femoral neck fracture, we reviewed the data of 83 patients who underwent preoperative bone scanning after femoral neck fracture. Fractures were classified using the Garden staging system. Radioisotope uptake in femoral heads was evaluated visually. Of 28 patients with Garden stage I or II, radioactivity of the femoral head was normal in 26, partially reduced in one, and generally reduced in one patient. Twenty-seven patients were treated by closed reduction and multiple pinning, and one patient was treated by bipolar hemiarthroplasty. Of 55 patients with Garden stage III or IV, femoral-head radioactivity was normal in three, partially reduced in seven and generally reduced in 45 patients. Fifty-four patients were treated by bipolar hemiarthroplasty or total hip arthroplasty, and one patient was treated by closed reduction and multiple pinning. In only one of the 83 cases was the operative method changed because of bone scan findings. Isotope uptake of the femoral head after femoral neck fracture generally corresponded with the degree of fracture displacement. Preoperative bone scans appear to have no significant role to play in determining the operative treatment method for femoral neck fracture.

Adolescent↗

Design of a subcutaneous vascular access device using Ni-Ti SMA clamps for hemodialysis.

A subcutaneous vascular access device which utilizes an Ni-Ti shape memory alloy (Ni-Ti SMA) spring, has been developed as a new method for subcutaneous vascular access in the treatment of hemodialysis patients. Until now, the connection between the SVAD and needle cannot be externally monitored, and the clamp must be opened and closed with a percutaneous needle by a nephrologist. The SMA-SVAD accomplishes the opening and closing of its clamp using two Ni-Ti SMA springs, and a transcutaneous energy transmission system (TET) transmits energy to the Ni-Ti SMA springs without the need for percutaneous wires. Two SMA springs open and close the clamp of the SMA-SVAD, without affecting any of the other parts of the system. Wasted thermal energy is reduced to minimal values via electrical regional heating methods. The state of the SMA-SVAD can be monitored according to the amount of power consumed by the external energy transmitter. In in-vitro experiments, when the clamp was opened and the pressure difference in the hemodialysis machine was set to 50 mmHg, water flow through SMA-SVAD reached 500 ml/min. The maximal surface temperatures of the SVAD and catheter were successfully maintained at proper levels (approximately 38-39 degrees C), approximately 2-3 degrees higher than the temperature of the surrounding tissues. The time elapsed from the initiation of energy transmission until the opening of the SMA clamp was 5 seconds.

Catheters, Indwelling↗

Development of a new pulsatile extracorporeal life support device incorporating a dual pulsatile blood pump.

A new pulsatile extracorporeal life support device (ECLS) has been developed, designed to sustain pulsatile blood flow during emergency cardiopulmonary resuscitations and cardiopulmonary operations. This device features two identical pulsatile pumps that operate alternately and can therefore provide blood inflow in a more uniform manner than similar systems featuring a single-pump configuration. In order to confirm the presumed benefits of this newly-developed dual pulsatile pump configuration, we have conducted a series of in vitro experiments designed to compare the properties of the new system with a single pump system, specifically with regard to pump delivery rate and active filling efficiency. Our results reveal that the dual pump configuration can, indeed, deliver a higher flow than can the single-pump system, and exhibits an active filling efficiency superior to that of the single-pump configuration. We performed a series of animal experiments to measure the pulsatility of the dual-pump configuration in terms of equivalent energy pressure (EEP). In order to measure EEP, we measured femoral arterial pressure and pump outflow. The results of our animal experiments revealed that the newly-developed pulstile ECLS exhibits sufficient pulsatility in terms of the EEP considerations.

Advanced Cardiac Life Support↗

Wireless patient monitoring system for a moving-actuator type artificial heart.

In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

Cell Phone↗

Self-management protocol for a moving-actuator type artificial heart.

In this paper, we describe the development of a self-management protocol for a controller of a moving-actuator type artificial heart, AnyHeart. The developed protocol analyzes motor current signals and detects abnormal pumping statuses. If preset abnormal pumping statuses are detected by an implemented algorithm, a controller triggers an emergency management procedure and transmits an alarm message to predetermined medical and engineering staffs via a cellular phone network to notify them of an abnormal pumping status occurrence and its likely cause. Results of in vitro performance experiments showed that the developed protocol can detect simulated abnormalities in motor current, manage the operating status of the blood pump during an emergency, and transmit an alarm message as desired.

Algorithms↗

Development of counterpulsation algorithm for a moving-actuator type pulsatile LVAD.

A pulsatile left ventricular assist device (LVAD) was used to support the aortic blood pumping function of an injured left ventricle, and as a result helped its recovery. It is important to observe a left ventricle's pumping status and to adjust the operating status of a LVAD to reduce the left ventricle's pumping load and thus to enhance its recovery. To observe the left ventricle's pumping status, an electrocardiogram (ECG) signal is generally used because it is a result of the natural heart's blood pumping function. In this paper, we describe the development of an ECG based counterpulsation control algorithm that prevents simultaneous aortic blood co-pumping by a left ventricle and a moving-actuator type pulsatile LVAD and as a result, reduces the natural heart's pumping load. In addition, to verify the algorithm's applicability for LVAD control we designed three ECG based automatic pump control algorithms that use a developed counterpulsation control algorithm. These algorithms control the operating status of a LVAD automatically and, at the same time, maintain a counterpulsing status. The results of in vitro experiments show that the counterpulsing effect between a left ventricle and a LVAD was successfully produced and that the newly designed automatic pump control algorithms met their own control purposes with a counterpulsing effect.

Algorithms↗

Treatment of mandible fractures using low-profile titanium miniplates: preliminary study.

This study evaluated the short-term results of patients treated with low-profile titanium miniplates for fractures of the mandible. Thirty-one fractures of the mandible in 23 patients were treated by open reduction and internal fixation using thin, low-profile miniplates and 1.3-mm self-threading screws. Duration of intermaxillary fixation ranged from 0 to 25 days. Patients were evaluated for complications during a follow-up period ranging from 6 to 24 months. Seven patients (30.4 percent) experienced complications. These included infection (n = 1), premature occlusal contact (n = 1), wound dehiscence (n = 1), temporomandibular joint disorder (n = 1), and paresthesia (n = 3). All complications were minor and adequately managed with incision and drainage, medication, and elastic traction. Low-profile titanium miniplates can be adequately used for internal fixation in selective mandibular fractures. Advantages of these types of plates include comfort due to the thinness of miniplates and ease of application.

Adolescent↗