PubMed Health⌕ Search

Biomedical subjects

K Wårdell

Publications and source records attributed to K Wårdell.

23 records · Page 2Linked to original sources

The cutaneous vascular axon reflex in humans characterized by laser Doppler perfusion imaging.

1. Laser Doppler perfusion imaging was used to map the cutaneous vascular axon response induced by trains of electrical skin stimuli (1 ms, 2 Hz) on the dorsum of the hand, finger and foot in twenty-four healthy subjects. Conduction anaesthesia was applied to nerves supplying the stimulated skin areas. Subtraction of images recorded before and after stimulation was used for data analysis of the intensity and area of the response. 2. The stimulation evoked a localized perfusion increase around the stimulating electrode which lasted approximately 30 min and increased in intensity and area with increasing stimulation strength to a maximum at 20 pulses and 20 mA. The intensity and area of the response was greater on the hand than on the foot. 3. Approximating the response area as a circle, the maximal perfusion increase in the hand extended 9 +/- 3 mm (mean +/- S.D.) outside the perimeter of the stimulating electrode. When stimulating within skin which had been subjected to surface anaesthesia, no response occurred, but when stimulating at the border of surface-anaesthetized skin, the perfusion increase extended 2 +/- 1 mm (mean +/- S.D.) into anaesthetized skin. 4. The results show that the perfusion increase must have been due in part to impulse conduction to, and release of transmitters from, axon endings terminating in skin outside the contact area of the probe. It is concluded that the area of perfusion increase corresponds to the size of the receptive fields of afferent polymodal C fibres.

Adult↗

Evaluation of port wine stain perfusion by laser Doppler imaging and thermography before and after argon laser treatment.

Thirteen patients with port wine stains (PWS) were treated with argon laser therapy. Before and at different points in time following treatment, skin blood perfusion and temperature were mapped with laser Doppler imaging and thermography. In nine patients no elevation in blood perfusion was observed in the PWS in comparison with the surrounding normal skin before treatment. In the remaining four patients a significantly (p less than 0.01) higher blood flow was recorded within the PWS. Immediately after treatment nine patients showed elevated perfusion within the PWS. During the first two days following treatment, all patients showed a gradually decreasing hyperperfusion in the borderline between the PWS lesion and surrounding skin. Immediately after treatment 10 patients had a significantly (p less than 0.01) higher temperature in the PWS than in normal skin. During the first 24 h following treatment, an elevated perfusion was in general accompanied by a tissue temperature increase. Three and a half months after argon laser treatment, three patients showed excellent clinical results with no remaining PWS spots or scarring. Two of these patients had had both elevated perfusion and temperature in the PWS prior to treatment.

Adolescent↗

Differential effect on vasodilatation and pain after intradermal capsaicin in humans during decay of intravenous regional anesthesia with mepivacaine.

BACKGROUND AND OBJECTIVES: When given intracutaneously, capsaicin can cause burning pain by central propagation in thin afferents, as well as neurogenic vasodilatation, reflecting antidromic conduction in the same fibers. We wanted to test the hypothesis that an intravenous regional block (IVRA) inhibits these two phenomena to a similar degree. METHODS: Sixteen healthy volunteers participated. A bilateral IVRA was performed by simultaneously injecting mepivacaine in one arm and normal saline in the other in a randomized, double-blind manner. Ten minutes after release of the tourniquet, neurogenic inflammation was inflicted in each forearm by intracutaneous capsaicin. Microvascular skin blood flow was measured with a laser Doppler perfusion imager. The area of the flare and the flow therein were measured, taking into account the change in baseline caused by mepivacaine treatment and the postischemic hyperemia. Pain was repeatedly evaluated by visual analog scale. RESULTS: The reactive hyperemia following arterial occlusion was less in the mepivacaine-treated arm 10 minutes after tourniquet release (P=.026). Intracutaneous capsaicin elicited a flare in both arms. The area of the flare was smaller 10 minutes after capsaicin (P=.009) in the mepivacaine-treated arm. There was no difference between the arms concerning the mean blood flow within the flare or in ischemic or capsaicin-induced pain. CONCLUSIONS: Mepivacaine, given as an IVRA, had no effect on the post-IVRA sensory function of thin afferents but differentially decreased the spread of the capsaicin-induced flare.

Adult↗

Polarized laser Doppler perfusion imaging--reduction of movement-induced artifacts.

Laser Doppler perfusion imaging (LDPI) enables superficial tissue perfusion assessment, but is sensitive to tissue motion not related to blood cells. The aim was to investigate if a polarization technique could reduce movement-induced artifacts. A linearly polarized laser and a cross-polarized filter, placed in front of the detectors, were used to block specular reflection. Measurements were performed with, and without, the polarization filter, at a single site during horizontal and vertical movement of skin tissue (index finger, twelve subjects, n = 112) and of a flow model (n = 432), with varying surface structures. Measurements were repeated during different flow conditions and at increased skin specular reflection. Statistical analysis was performed using ANOVA models. The perfusion signal was lower (p < 0.001, skin and p < 0.05, flow model) using the polarization filter, due to movement artifact reduction. No significant influence from surface structure was found when using the polarization filter. Movement artifacts were lower (p < 0.05) in the vertical movement direction, however, depending on flow conditions for skin measurements. Increased skin specular reflection gave rise to large movement artifacts without the polarization filter. In conclusion, the polarized LDPI technique reduces movement artifacts and is particularly appropriate when assessing, e.g., ulcers and burns, where specular reflection is high.

Adult↗