Aerosol penetration through surgical masks.

BACKGROUND: Surgical masks are used in hospitals to reduce postoperative infection in patients. The presence of aerosols containing pathogens makes it desirable to protect the medical staff as well. METHODS: The collection efficiencies of surgical masks measured with two aerosol-size spectrometers. The flow rates through the masks were varied from 5 to 100 L/min to study the flow dependency. For comparison, several industrial-type respirators were also tested. RESULTS: A surgical mask consisting of filter material performed better than did a surgical mask consisting only of a shell with a coarse pore structure. The latter passed 80% of submicrometer-sized aerosols with little flow dependency, whereas the penetration of submicrometer-sized aerosols through the mask made of filter material ranged from 25% at a flow rate of 5 L/min to 70% at 100 L/min. CONCLUSIONS: The mask that has the highest collection efficiency is not necessarily the best mask from the perspective of the filter-quality factor, which considers not only the capture efficiency but also the air resistance. Although surgical mask media may be adequate to remove bacteria exhaled or expelled by health care workers, they may not be sufficient to remove the submicrometer-size aerosols containing pathogens to which these health care workers are potentially exposed.

Aerosols

Characteristics of face seal leakage in filtering facepieces.

Several studies have found that aerosol size, testing method, leak size, leak position, sampling probe location, and the mixing condition inside the respirator affect the results of fit factor measurements. This study focuses on the effect of leak shape and filter resistance because leaks have been reported to vary in shape from circular to slit-like. Four leaks of different shape but the same cross-sectional area were used to study their effect on aerosol penetration. Dust-mist and high-efficiency particulate air filtering facepieces provided different filter resistances. An aerodynamic particle sizer and a laser aerosol spectrometer were used to measure the particle size-dependent aerosol concentrations inside and outside the respirators. The filtering facepieces were sealed to a mannequin and artificial leaks were inserted near the right cheek. Aerosol penetration was measured for five flow rates ranging from 5 to 100 L/min. The pressure drop across the mask was monitored with an inclined manometer. At a given pressure differential, a slit-like leak and multiple circular leaks have been found to pass less aerosols than a single circular leak of equal cross-sectional area because the leak flow decreases with an increase in leak shape complexity. If there is substantial lack of face seal fit and the breathing rate is low, a HEPA respirator may provide less protection than a dust-mist respirator because the pressure drop is considerably higher for a HEPA respirator, resulting in more aerosol flow through the leak.

Aerosols

Aerosol penetration through filtering facepieces and respirator cartridges.

Air-purifying respirators must be certified following the National Institute for Occupational Safety and Health (NIOSH) filter test criteria (30 CFR 11). The criteria specify a range for the mean particle size and the measure of spread permissible for the test aerosol. The authors' experiments have shown that aerosol penetration as a function of particle size differs considerably among certified respirators of the same type. Filtering facepieces (disposable respirators) and cartridges of the dust-mist, dust-mist-fume, and high-efficiency particulate air type were tested. The respirators were sealed to mannequins in a test chamber. The aerosol concentrations inside and outside the respirator were measured by an aerodynamic particle sizer and a laser aerosol spectrometer over a particle size range of 0.1 to 15 microns. Five flow rates ranging from 5 to 100 L/min were used to study flow dependency. The aerosol penetration through the filters is presented as a function of particle size. Aerosol penetration and pressure drop are combined to express the performance of each filter in terms of "quality factor." Under the same test conditions, the quality factor of one respirator may be as much as 6.6 times more than that of another respirator of the same type. The filter quality factor has a greater aerosol size dependency as airflow and aerosol size increase. In general, cartridges have a larger surface area than filtering facepieces but not necessarily lower filter penetration or higher filter quality.(ABSTRACT TRUNCATED AT 250 WORDS)

Aerosols

An investigation of dust generation by free falling powders.

To identify the dust generation processes, aluminum oxide powder was dropped as a free falling slug in a test chamber. The effect of the slug's mass, diameter, and drop height upon the aerosol concentration and size distribution was measured with an aerodynamic particle sizer. To differentiate between aerosol generated during the free fall and at the end of the fall, the slug was dropped either onto a flat surface or into a container of water that suppressed dust generation associated with the impact at the end of the fall. Aerosol generation occurred during the slug's free fall as well as at the end of the fall. The falling solid induced an airflow that followed the falling solid to the end of the fall. This induced airflow contained the aerosol generated during the free fall. At the end of the free fall, the induced airflow, combined with air jets created on impact, dispersed the aerosol throughout the test chamber. Additional measurements were made by using "neutral buoyancy" helium-filled bubbles to visualize the airflow in the test chamber. The airflow and ensuing turbulence were sufficient to keep large, inspirable particles suspended throughout the test chamber for periods greater than 10 min. During experimental work, the effect of drop height, mass, and slug diameter upon aerosol generation by a single slug of powder was studied. The results indicated that the manner in which a powder is handled may be as important as material dustiness as measured by a dustiness tester. Aerosol generation can be reduced by minimizing the contact between the falling powder and the air.

Aerosols

Simplified pressure method for respirator fit testing.

A simplified pressure method has been developed for fit testing air-purifying respirators. In this method, the air-purifying cartridges are replaced by a pressure-sensing attachment and a valve. While wearers hold their breath, a small pump extracts air from the respirator cavity until a steady-state pressure is reached in 1 to 2 sec. The flow rate through the face seal leak is a unique function of this pressure, which is determined once for all respirators, regardless of the respirator's cavity volume or deformation because of pliability. The contaminant concentration inside the respirator depends on the degree of dilution by the flow through the cartridges. The cartridge flow varies among different brands and is measured once for each brand. The ratio of cartridge to leakflow is a measure of fit. This flow ratio has been measured on human subjects and has been compared to fit factors determined on the same subjects by means of photometric and particle count tests. The aerosol tests gave higher values of fit.

Humans

Effect of work load and respirator wear on postural stability, heart rate, and perceived exertion.

The effects on postural stability (sway) were investigated for different work loads under conditions of wearing a full facepiece respirator and not wearing any respiratory protection device. Fifteen subjects accomplished light (40 W), moderate (85 W), and heavy (125 W) work loads under the two conditions. Measurements of postural sway were made immediately after each load by using a multicomponent, strain gage-type force platform. Changes in each subject's movement pattern of the center of pressure were quantitated and compared to their initial baseline sway tests. Each subject's heart rate and perceived exertion were also recorded during each condition. A statistically significant effect (p = 0.007) caused by work load was observed for total length of sway with or without a respirator. An interaction approaching statistical significance (p = 0.056) between work load and respirator use was found. This indicated that sway increased more quickly and in a more consistently linear fashion with increasing work load under the respirator condition (p = 0.02) compared to the nonrespirator condition. The results from the respirator condition showed linear increases in postural sway length across the entire range of work loads, but sway length in the nonrespirator condition showed an increase only at 125-W work loads. The greater increase in sway during the postural balance test could be attributable to the increasing work load-induced proprioceptive fatigue effect on the nervous system's ability to process signals from proprioception systems incongruent with body sway. The heart rate was significantly higher during respirator wear (an increase in heart rate averaging 5.62 beats/min).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Respirator fit and protection through determination of air and particle leakage.

A laboratory technique for determining the respirator protection factor from a test of fit is described. A dynamic pressure test quantifies the air flow through the leak. Calibration data, stored in a computer, relate the contaminant influx to this air flow, and a similar pressure test determines the flow through the respirator cartridges and, therefore, the dilution characteristics. Contaminant removal characteristics of the cartridges are stored in the computer. The contaminant penetration is calculated from these data on flow and removal efficiency. Through specification of the aerosol size distribution and the method of measurement, protection factors are calculated for specific work environments, work loads and respirator cartridges. The protection factor is shown to be highly dependent on the method of measuring the contaminant and on the cartridges used.

Air Pollutants

Sampling and interpretation errors in aerosol monitoring.

The aerosol recorded by simple filter collection or by sophisticated instrument aerosol monitoring may differ considerably from the original, unsampled aerosol. Through use of particle-sizing instruments and computer modeling, the potential biases in sampling, display, and interpretation are demonstrated. The aerosol-size distribution and, therefore, the reported number or mass concentration may be affected by the characteristics of the sampling inlet, the transport to the sensor and the sensor itself. The particle count in specific size ranges determines the precision of the registered particle-size distribution, depending on the weighting chosen. The type of display, by histograms or cumulative plot, focuses on different aspects of the size distribution, and the calibration of the aerosol monitor may modify it further. Particle-size classification to simulate a specific region of the human respiratory system may be achieved through inertial classification or the sensitivity characteristics of the aerosol sensor. Aerosol monitors using passive sampling register the same aerosol-size distribution as active ones, if the aerosol is transported to the sensor with the same efficiency as in the active mode. The sources of various types of errors are presented using computer simulations of typical aerosol-size distributions, often combined with measurements found in the literature. Presentation of these errors in graphical format allows the health professional to estimate more accurately the health implications of aerosol measurements.

Aerosols

Filter and leak penetration characteristics of a dust and mist filtering facepiece.

The filtering facepiece, also referred to as a disposable respirator, is an extensively used type of respirator without an officially accepted fit testing method. This study describes an aerosol generator and a sampling train, which have been developed for investigating the aerosol penetration characteristics through the filter element and the face seal. Electrostatic attraction and impaction are the two primary filtration mechanisms for micrometer- and supermicrometer-sized aerosols, respectively. Filtration and flow dynamics were found to affect aerosol penetration in distinct ways that allow for the differentiation of the face seal leakage from the filter penetration. The slope of the aerosol size-dependent penetration curve potentially may differentiate the face seal leakage from filter penetration.

Aerosols

Variable-cut particle-size classification by opposing jets.

A new technique of aerodynamic particle-size classification has been developed utilizing axisymmetrically-opposed air jets. For a fixed geometry the cut size can be varied from 0.8 to 3.6 micrometer by changing the jet flow rates. Future designs are expected to extend the useful particle-size range. Particles remain airborne after size separation, permitting the use of continuous, automated methods for analyzing the particle concentration and chemical compositon.

Air Pollutants

Performance of the slotted impactor.

Slotted impactors perform with a sharpness of cut close to the theoretically predicted value, if used under the conditions of the numerical model. Sideways flow entrance and impaction onto a fibrous surface may change the collection efficiency considerably.

Aerosols