PubMed Health⌕ Search

Biomedical subjects

Károly Vékey

Publications and source records attributed to Károly Vékey.

At least 19 recordsLinked to original sources

Analysis of sterols by high-performance liquid chromatography/mass spectrometry combined with chemometrics.

A newly developed high-performance liquid chromatography/mass spectrometry (HPLC/MS) method has been successfully used to analyze plasma concentrations of various phytosterols (cholestanol and beta-sitosterol) and cholesterol metabolites (desmosterol and lathosterol). This was based on an unusual solvent combination of water/methanol vs. methanol/acetone/n-hexane applied on a Purospher Star RP-18e (125 x 2 mm, 3 microm) column, which proved excellent for the separation, identification and quantification of plasma sterols. Simple solid-phase extraction preparation of plasma samples was performed, followed by the developed fast and robust HPLC separation. Results on four groups of people were compared, those with low, normal and high plasma cholesterol levels and those with high cholesterol levels on statin therapy, and the results were evaluated using linear discriminant analysis (LDA). Variable selection for LDA was achieved using backward removal selection. Highly discriminatory variables were the ratios of desmosterol to sitosterol and of lathosterol to total plasma cholesterol. The latter ratio was also excellent for distinguishing subjects on statin therapy. The success rate of classification was 100%. The present pilot study shows the potential of HPLC/MS analysis and chemometrics for studying cholesterol-related disorders and warrants future full-scale medical study.

Cholestanol↗

Combination of sustained off-resonance irradiation and on-resonance excitation in FT-ICR.

Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry is becoming more widely used among the mass spectrometric techniques and has excellent figures of merit. Ion activation and fragmentation via sustained off-resonance irradiation (SORI) collision-induced dissociation (CID) is commonly used in FT-ICR. However, one of the limitations of SORI-CID is that only low-energy processes are typically observed in the product ion spectra. Here we present another option for performing CID in FT-ICR, a combination of SORI and on-resonance excitation (RE), termed SORI-RE. In comparison to SORI, this method produces more abundant ions resulting from higher energy fragmentation pathways. The result is the observation of a significant abundance of both higher and lower energy fragmentation pathways in the same mass spectrum. The comparison of SORI, RE, and SORI-RE spectra may lead to mechanistic insights as the relative abundances of certain fragment ions change as a function of internal energy deposition. This technique is simple to incorporate in existing instruments, does not require hardware or software modification, and requires only an additional 20-40 ms acquisition time. The technique is illustrated for a peptide (YGGFL), two disaccharides differing in the position of the glycosidic linkage (2alpha-mannobiose, 3alpha-mannobiose), an oligosaccharide (Alditol XT), a small protein (ubiquitin), and an inorganic cation (UO2+). Examples of higher energy fragmentation pathways enhanced by SORI-RE include the formation of immonium ions and oligosaccharide cross-ring cleavages.

Enkephalin, Leucine↗

Mass spectrometric and quantum-chemical study on the structure, stability, and chirality of protonated serine dimers.

Stability and structure of homo- and heterochiral protonated serine (Ser) dimers were investigated by a combination of mass spectrometry and ab initio quantum chemical calculations. This established that the energy difference between the most stable homo- and heterochiral forms is very small: tandem mass spectrometry with Cooks' kinetic method yielded a negligible difference in Gibbs free energy (0.2+/-0.2 kJ mol(-1)). The various isomeric forms of (Ser)2 H+ and their energetics were determined by extensive electronic-structure calculations, which yielded homo- and heterochiral forms of the isomers with distinctly different relative energies. The most stable homochiral isomer is stabilized by two hydrogen bonds and is far more stable than any other homochiral isomer. The most stable heterochiral isomer has completely different features, and it is characterized by a salt-bridge structure. This clearly shows that salt-bridge structures do exist in the gas phase even in comparatively small molecules and in the absence of particularly basic or acidic functional groups.

Mass Spectrometry↗

High performance liquid chromatography-mass spectrometry based chemometric characterization of olive oils.

In this study the effective discrimination of extra virgin olive oils is described using HPLC-MS, combined with chemometric evaluation. The presented method is simple since the diluted oil sample is directly injected into the system, without any preliminary chemical derivatization or purification step. Separation of diacylglycerols, triacylglycerols and sterols occurs within 20 min and is achieved using an octadecyl-silica column. Detection is performed by positive APCI mass spectrometry which provided sensitivity to detect over 50 compounds in the sample. After extraction of data, stepwise discriminant function analysis is used to select the variables with the highest discriminative power. These variables are used to perform linear discriminant analysis and classify/predict the samples. One-hundred per cent classification and 99% prediction rate was achieved for olive oils obtained from Nocellara, Biancolilla and Cerausola cultivars. Reliability of prediction was tested by cross validation.

Chromatography, High Pressure Liquid↗

Amino acid cluster formation studied by electrospray ionization mass spectrometry.

The association properties of natural and non-natural amino acids were studied in detail using electrospray ionization mass spectrometry. The results show a highly diverse cluster formation behavior of amino acids. There are differences regarding the degree of clustering (average cluster size), the presence or absence of one or several 'magic' clusters of special stability and the influence of chirality on cluster stability. Cluster formation does not show a good correlation with simple physico-chemical properties (such as solubility), indicating that it is a specific process and not only a simple aggregation during evaporation/ionization. A systematic study of cluster formation of serine derivatives reveals that all functional groups play a prominent role in the binding of the magic octamer. The results support the idea of the zwitterionic character of the octamer. Electrospray ionization of the side-chain acetylated serine shows the formation of a very stable tetramer with a strong preference for homochirality. The results suggest that Ser8 is made up of two tetramer subunits, held together by hydrogen bonds of the side-chain.

Amino Acids↗

Internal energy distribution in electrospray ionization.

Internal energies and energy distributions were studied using the 'survival yield' method developed previously. In addition to conventional benzylpyridinium salts, protonated esters (fragmenting by rearrangement) and protonated leucine enkephalin were also used, extending the validity of the technique. Fragmentation processes were studied in the cone voltage region and modeled by the RRKM-based MassKinetics program. The results show that the shapes of the energy distributions are similar to thermal distributions. The mean internal energies are very similar for all compound classes studied, and show a linear increase with collision energy in the 10-50 eV region.

Energy Transfer↗

Glycosylation site analysis of human alpha-1-acid glycoprotein (AGP) by capillary liquid chromatography-electrospray mass spectrometry.

A new anionic surfactant (RapiGest SF) was successfully used for site-specific analysis of glycosylation in human alpha-1-acid glycoprotein (AGP). By means of this analytical approach combined with capillary HPLC-mass spectrometry (and tandem mass spectrometry), the N-linked glycosylation pattern of AGP was explored. On the basis of mass matching and MS/MS experiments ca 80 different AGP-derived glycopeptides were identified. Glycosylation shows a markedly different pattern for the various glycosylation sites. At sites I and II, triantennary complex-type oligosaccharides predominate and at sites III, IV and V, tetra-antennary complex-type oligosaccharides predominate. Sites IV and V show the presence of additional N-acetyl lactosamine (Gal-GlcNAc) units (even higher degree of branching and/or longer antennae are also present).

Chromatography, Liquid↗

Combination of solid-phase affinity capture on magnetic beads and mass spectrometry to study non-covalent interactions: example of minor groove binding drugs.

A simple and novel approach was developed to detect non-covalent interactions. It is based on combination of solid-phase affinity capture with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). One of the interacting molecules is bound to magnetic beads and is incubated with the target molecules in solution. The complex bound on the solid support is removed from the solution and transferred for MALDI analysis. Mass spectrometry is used only to detect the target compound, which is far more straightforward than detecting the intact non-covalent complex. To demonstrate the applicability of the method, an AT-rich oligonucleotide (5'-CCCCCAATTCCCCC-3') and its complementary biotinylated sequence (5'-biotin-GGGGGAATTGGGGG-3') were hybridized and immobilized to paramagnetic particles by streptavidin-biotin interaction. The immobilized duplex oligonucleotide was reacted with minor groove binding drugs, Netropsin, Distamycin A, Hoechst 33258 and 4',6-diamidino-2-phenylindole. The resulting DNA-drug complex bound to the particles was separated and analyzed by linear MALDI-TOFMS after washing. Drugs were selectively detected in the spectra. Relative binding strengths were also estimated using competitive complexation.

Biotin↗

Electrospray ionization fourier transform ion cyclotron resonance mass spectrometry of human alpha-1-acid glycoprotein.

The ultrahigh resolution and sensitivity of electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry have for the first time been exploited for the characterization of highly sialylated glycoproteins, using human alpha-1-acid glycoprotein as the model compound. An alternative approach to the widely used high-performance liquid chromatography (HPLC) and matrix-assisted laser desorption/ionization (MALDI) assays is described. This new method does not require any enzymatic or chemical digestion (removal of sialyl groups or deglycosylation), chemical derivatization (introduction of chromophore groups), or preliminary chromatographic separation (HPLC or electrophoresis). Following ESI and accumulation of ions in a hexapole ion guide, ions are injected into the ICR cell. A selected mass window from the overall ion population is isolated and axialized prior to detection. After acquisition and Fourier transform of the transient signal the resulted spectrum is evaluated in order to determine the charge state of the detected ions and the isotope pattern of the measured protein glycoform. The presence of ions from the same glycoform with different charge states was confirmed. The advantages and limitations of the technique are discussed. Future prospects and possible applications are indicated.

Amino Acid Sequence↗

An HPLC-MS approach for analysis of very long chain fatty acids and other apolar compounds on octadecyl-silica phase using partly miscible solvents.

A novel approach for analyzing underivatized very long chain fatty acids (C16-C26) and other apolar compounds such as triacylglycerols is described. It is based on reversed-phase HPLC separation followed by mass spectrometric detection. Partly miscible solvents are used for stepwise gradient elution starting with a methanol/water and ending with a methanol/n-hexane binary mixture. The developed technique does not need derivatization, and analysis is fast (fatty acids were separated in 2-min-long chromatograms) and robust. The developed method is also very sensitive; a quantitation limit in the low-picogram range was achieved for fatty acids. The separation mechanism and advantages of the suggested technique are discussed and illustrated in the case of blood analysis and plant oil characterization.

Chromatography, High Pressure Liquid↗

Solid-phase microextraction: a powerful sample preparation tool prior to mass spectrometric analysis.

Sample preparation is an essential step in analysis, greatly influencing the reliability and accuracy of resulted the time and cost of analysis. Solid-Phase Microextraction (SPME) is a very simple and efficient, solventless sample preparation method, invented by Pawliszyn in 1989. SPME has been widely used in different fields of analytical chemistry since its first applications to environmental and food analysis and is ideally suited for coupling with mass spectrometry (MS). All steps of the conventional liquid-liquid extraction (LLE) such as extraction, concentration, (derivatization) and transfer to the chromatograph are integrated into one step and one device, considerably simplifying the sample preparation procedure. It uses a fused-silica fibre that is coated on the outside with an appropriate stationary phase. The analytes in the sample are directly extracted to the fibre coating. The SPME technique can be routinely used in combination with gas chromatography, high-performance liquid chromatography and capillary electrophoresis and places no restriction on MS. SPME reduces the time necessary for sample preparation, decreases purchase and disposal costs of solvents and can improve detection limits. The SPME technique is ideally suited for MS applications, combining a simple and efficient sample preparation with versatile and sensitive detection. This review summarizes analytical characteristics and variants of the SPME technique and its applications in combination with MS.

Animals↗

Accuracy of enthalpy and entropy determination using the kinetic method: are we approaching a consensus?

There is an emerging consensus regarding the applicability of the kinetic method. All parties acknowledge that it is an approximate quantitative technique, capable of yielding not only enthalpy, but also entropy values. Opinions differ mainly on the accuracy of the results but it is agreed that the energy (effective temperature) dependence of kinetic method plots needs to be checked in all but the simplest of cases. When the 'apparent basicity' is found to depend on collision energy (and hence effective temperature), the extended kinetic method must be used. We have performed a large-scale modeling study, involving thousands of randomly selected molecular systems and a variety of experimental conditions, using exact calculations and realistic data sets. The results show that when the measured entropy difference between the two competing reaction channels is less than approximately 35 J mol(-1) K(-1), overall errors (standard deviations) of DeltaH(298) determined by the kinetic method are +/-5 kJ mol(-1); those of DeltaS(298) are +/-10 J mol(-1) K(-1). These include not only inherent errors of the kinetic method, but also errors in ion abundance measurement (5%) and inaccurate knowledge of reference compound thermochemistry (+/-2 kJ mol(-1), on average). We recommend, in general, that these errors be reported in kinetic method studies. When the measured entropy difference between the two competing fragmentation channels is large (>35 J mol(-1) K(-1)), it is likely to be significantly underestimated and errors of the kinetic method increase significantly.

Journal Article↗

Atmospheric pressure chemical ionization mass spectrometry of aldehydes in biological matrices.

Application of high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) for detection of aldehydes in biological samples such as blood, yoghurt, and milk, is reported. Sample preparation is easy, and the presented method is both sensitive and selective. It is based on the widely used dinitrophenylhydrazine derivatization, followed by extraction with n-hexane and a simple reversed-phase HPLC separation. Detection is performed by atmospheric pressure chemical ionization (APCI) in negative ion mode, with detection limits in the low picogram range. Using MS/MS, acetone and propionaldehyde can clearly be distinguished, facilitating propionaldehyde quantitation even in the presence of high acetone levels. Quantitation by direct MS/MS is also feasible, well suited for high-throughput applications, although not as accurate as using HPLC/MS/MS.

Aldehydes↗

Low-temperature SIMS mass spectra of diethyl ether.

For the first time a secondary ion mass spectrum of diethyl ether was obtained at low temperature. The spectrum recording became possible by carefully selecting the range of experimental conditions for the production of a cluster-type spectrum. This range is specified by the threshold for spectrum appearance above the melting temperature of the frozen sample and a fairly short time span of existence of the liquid estimated as only a few minutes. The latter necessitates rather rapid spectrum detection. In practice, about 1 min was available for recording of the cluster-type spectra. The secondary emission mass spectrum of diethyl ether appeared to be rich in peaks: along with abundant protonated clusters M(n).H(+) (n = 1-12), unusually intense [M(n) - H](+) and weaker M(n) (+.) peaks were present accompanied by several sets of fragmented clusters, [M(n) - 15](+), [M(n) - 29](+), [M(n) - 27](+), [M(n) - 45](+), and monohydrates, M(n).H(2)O.H(+). The analysis of all the peaks showed that the pattern of fragment clusters is qualitatively similar to the pattern of fragmentation of the diethyl ether molecular ion under high-energy electron impact. The general features of the behaviour of diethyl ether under low-temperature mass spectrometric conditions were similar to those observed earlier for some other organic solvents.

Journal Article↗

Entropy evaluation using the kinetic method: is it feasible?

The kinetic method is one of the most widely used experimental techniques for the measurement of thermochemical parameters by mass spectrometry. Recently it has been realized that it can also be used to determine reaction entropies, but the validity of this approach has not been established. This Perspective evaluates kinetic method plots in cases where there is a significant entropy difference between the competing fragmentation channels (i.e. between sample and reference compounds in the dissociating cluster ion). The concept underlying this study is to calculate mass spectra theoretically, based on known thermochemical parameters and as a function of experimental conditions. This can be done accurately using the RRKM-based MassKinetics software. The resulting mass spectra are then interpreted by the kinetic method, yielding DeltaH and DeltaS values. These values are, in turn, compared with the true values used to generate the calculated mass spectra. The results show that the reaction entropy difference between sample and reference has a very large influence on kinetic method plots. This should always be considered when studying energy-dependent mass spectra (using metastable ions or low- or high-energy collision-induced dissociation (CID)), even if only DeltaH is to be determined. Kinetic method plots are not strictly linear and this becomes a serious issue in the case of small molecules showing a large entropy effect. In such cases, results obtained at a low degree of excitation are more accurate. Energy and entropy effects can be evaluated in a relatively straightforward manner: first, the apparent Gibbs energy (DeltaG(app)) and effective temperature (T(eff)) are determined from kinetic method plots (intercept and slope, respectively), obtained from experiments using various degrees of excitation. Second, the resulting DeltaG(app) is plotted against T(eff), the slope yielding DeltaS while the intercept (extrapolation to zero temperature) yields DeltaH. This data evaluation yields more accurate results than alternative methods used in the literature. The resulting DeltaH values are fairly accurate, with errors, in most cases, <4 kJ mol(-1). On the other hand, DeltaS is systematically underestimated by 20-40%. Empirically scaling DeltaS values determined by the kinetic method by 1.35 results in a DeltaS value within 20% (or 10 J mol(-1) K(-1)) of the theoretical value.

Journal Article↗

Formation of solvated ions in the atmospheric interface of an electrospray ionization triple-quadrupole mass spectrometer.

A simple method capable of generating and investigating various solvent clusters and solvated ions was developed. The technique opens a door to studying these complexes on commercially available instruments. Formation of the desired solvated ion in the gas phase was achieved by introducing the appropriate volatile solvent vapour into the curtain gas stream. Capabilities of the technique are illustrated by generating alkali, alkaline earth and transition metal cations solvated by various volatile compounds such as water, methanol and acetonitrile. Depending on the ligands and on the experimental conditions, clusters of 2-100 molecules may be observed. Isotope labelling suggests that these are formed by a re-solvation process in the curtain gas region.

Journal Article↗

Mass spectrometric analysis of combinatorial peptide libraries derived from the tandem repeat unit of MUC2 mucin.

Four 19-member synthetic peptide libraries, based on the TX1TX2T epitope motif of the mucin-2 gastrointestinal glycoprotein (MUC2) and ranging in peptide length from dipeptides to 15-mers (XT, TXT, TQTXT and KVTPTPTPTGTQTXT), were synthesized by combinatorial solid phase peptide synthesis using the portioning-mixing combinatorial approach, and analysed by electrospray ionization mass spectrometry at different (1000-10000) resolutions. Most of the components of the individual libraries could be easily identified in a single-stage molecular mass screening experiment. The resolving power of the instrument becomes an important factor above 800-1000 Da molecular mass, when predominantly multiply charged molecular ions are formed. Approaches to the identification of isobars (glutamine/lysine), isomers leucine/isoleucine) and sequence variations by tandem mass spectrometry, and/or by high-performance liquid chromatography-mass spectrometry are outlined.

Amino Acid Sequence↗

Direct tandem mass spectrometric analysis of amino acids in dried blood spots without chemical derivatization for neonatal screening.

Neonatal screening performed by electrospray tandem mass spectrometry is a powerful technique in clinical diagnostics. In the present paper an alternative to the widely accepted method involving butylation has been developed. In the new method butylation is not required, and multiple reaction monitoring (MRM) was used instead of constant neutral loss scanning. The method was optimized for detection of 23 L-amino acids in their native form. Quantitation was based on isotope-labeled internal standards, calibration curves were linear from 0 to 500 micromol/L, and detection limits were in the range 2-42 micrmol/L. The utility of the present technique is illustrated in the case of one neonate suffering from citrullinaemia.

Amino Acid Metabolism, Inborn Errors↗