PubMed Health⌕ Search

Biomedical subjects

Kanako Yamaguchi

Publications and source records attributed to Kanako Yamaguchi.

7 recordsLinked to original sources

A pilot randomized control study to evaluate endoscopic resection using a ligation device for rectal carcinoid tumors.

AIM: Rectal carcinoid tumors smaller than 10 mm can be resected with local excision using endoscopy. In order to remove rectal carcinoid tumors completely, we evaluated endoscopic mucosal resection with a ligation device in this pilot control randomized study. METHODS: Fifteen patients were diagnosed with rectal carcinoid tumor (less than 10 mm) in our hospital from 1993 to 2002. There were 9 males and 6 females, with a mean age 61.5 years (range, 34-77 years). The patients had no complaints of carcinoid syndrome symptoms. Fifteen patients were randomly divided into 2 groups: 7 carcinoid tumors were treated by conventional endoscopic resection, and 8 carcinoid tumors were treated by endoscopic resection using a ligation device. RESULTS: All rectal carcinoid tumors were located at the middle to distal rectum. The size of the tumors varied from 3 mm to 10 mm and background characteristics of the patients were not different in the two groups. The rate of complete removal of carcinoid tumors using a ligation device (100%, 8/8) was significantly higher than that of conventional endoscopic resection (57.1%, 4/7). The three patients had tumor involvement of deep margin, for which additional treatment was performed. No complications occurred during or after endoscopic resection using a ligation device. All patients in the both groups were alive during the 3-year observation period. CONCLUSION: Endoscopic resection using a ligation device is a useful and safe method for resection of small rectal carcinoid tumors.

Adult↗

Effect of thermal cycling on bond strengths of single-step self-etch adhesives to bovine dentin.

The purpose of this study was to clarify the effect of thermal cycling on dentin bond strengths of single-step self-etch adhesives. Five commercially available single-step self-etch systems were used. The adhesives were applied to the dentin surfaces of bovine incisors, and then light-irradiated. Resin composites were condensed into a mold and light-irradiated. Bonded specimens were divided into two groups and stored in water at 37 degrees C for 24 h without thermal cycling, or in water at 37 degrees C for 24 h followed by 10,000 thermal cycles between 5 degrees C and 60 degrees C. Ten samples per group were tested for shear strength at a crosshead speed of 1.0 mm/min. The data were analyzed by Student's t test and Tukey HSD test at a probability level of 0.05. After 24 h of storage in water, the mean dentin bond strengths ranged from 9.3 MPa to 14.0 MPa. After 10,000 thermal cycles, the mean bond strengths remained unchanged. Failure after the test was commonly due to adhesive breakdown associated with partial cohesive failure of the resin. The present results suggest that the benefit of using single-step self-etch systems, in terms of simplifying the clinical procedure, might be acceptable even after thermal stresses.

Acid Etching, Dental↗

Effect of CPP-ACP paste on mechanical properties of bovine enamel as determined by an ultrasonic device.

OBJECTIVE: The purpose of this study was to determine the effect of Casein Phosphopeptide-Amorphous Calcium Phosphate (CPP-ACP) paste on demineralization of bovine enamel by measuring changes in the ultrasound transmission velocity. METHODS: The enamel specimens were prepared by cutting bovine teeth into blocks. The specimens were stored in 0.1 M lactic acid buffer solution (pH 4.75, Ca 0.75 mM, P 0.45 mM) for 10 min twice a day, and then stored in the artificial saliva (pH 7.0). Other specimens were stored in a 10-times diluted solution of CPP-ACP paste and a placebo paste without CPP-ACP for 10 min, followed by 10 min immersion into a demineralization solution twice a day before storage in the artificial saliva. The propagation time of longitudinal ultrasonic waves was measured by a Pulser-Receiver (Model 5900, Panametrics) with a transducer (V112, Panametrics). Six specimens were used for each condition, and one-way ANOVAs followed by the Tukey HSD tests (alpha = 0.05) were done. RESULTS: The sonic velocity was found to decrease with time for specimens stored in the demineralization solution. On the other hand, a significant increase in sonic velocity was found for specimens stored in the CPP-ACP solution. CONCLUSIONS: From the result of this study, it was suggested that the conditions of de- and remineralization of the enamel structure could be measured non-destructively by using an ultrasonic pulse method. It could be concluded that the inorganic components contained in high concentrations in CPP-ACP acted to enhance remineralization of the enamel structure.

Animals↗

Influence of crosshead speed on micro-tensile bond strength of two-step adhesive systems.

OBJECTIVES: The purpose of this study was to determine the influence of crosshead speed on the micro-tensile bond strength of two separate adhesive systems to dentin. METHODS: The systems used were the Clearfil SE Bond (Kuraray Medical) and the Single Bond (3M ESPE) combined with a resin composite Clearfil AP-X (Kuraray Medical). Dentin surfaces of bovine madibular incisors were primed with self-etching primer followed by air blowing for Clearfil SE Bond, or etched with phosphoric acid followed by rinsing with distilled water for Single Bond, and adhesive was applied. The resin composite was then built up in three layers and light activated. After 24 h storage in water, specimens were sectioned and trimmed to a cross-sectional area of 1 mm(2) and subjected to a micro-tensile bond-strength test. Ten samples per test group were tested at crosshead speeds of 0.5, 1.0, 5.0 and 10.0 mm/min. Micro-tensile bond-strength values (in MPa) were calculated from the peak load at failure divided by the specimen surface area. Two-way ANOVA was performed at the 0.05 probability level. RESULTS: The mean dentin bond strength at different crosshead speeds ranged from 34.6 to 37.1MPa for Clearfil SE Bond and from 44.3 to 50.4 MPa for Single Bond. There was no significant difference among the same adhesive systems with the different crosshead speeds tested. SIGNIFICANCE: The influence of the crosshead speed might be negligible when measuring micro-tensile bond strengths.

Acid Etching, Dental↗

Effect of metal conditioners on polymerization behavior of bonding agents.

This study aimed to determine the influence of metal conditioners on the polymerization behavior of bonding agents. Bonding agents of two-step self-etching primer systems and metal conditioners for adhesion of dental metal alloys were used. Double bond conversion was determined by Fourier transform-ation infrared spectroscopy. The percentage of residual double bonds, including pendant and monomeric double bonds, was calculated by comparing the obtained ratio with that of the uncured bonding agent. The degree of conversion of the bonding agents was obtained by subtracting the remaining double bonds from 100%. ANOVA followed by a Tukey HDS test was performed. Degree of conversion of the bonding agents ranged from 86.0 to 87.8%. When the bonding agents were mixed with metal conditioners or solvents of the metal conditioners, double bond conversion of the bonding agents tended to decrease. Within the limitations of this study, which was far removed from clinical situations, the presence of metal conditioners and remaining solvents had adverse effects on the polymerization reaction of bonding agents. Clinicians should be cognizant of the various factors that can influence bond strength of restorative resins to dentin.

Acetone↗

Bonding efficacy of single-step self-etch systems to sound primary and permanent tooth dentin.

Currently, there is little information regarding the bonding efficacy of single-step self-etch systems to primary tooth dentin. This study examined the microtensile bond strength of single-step self-etch systems (Clearfil tri-S Bond and One-Up Bond F Plus) to sound primary and permanent tooth dentin. Adhesives were applied to flat samples of primary and permanent tooth dentin, and resin composites were bonded according to the manufacturers' instructions. After 24 hours of storage in distilled water at 37 degrees C, hour glass-shaped specimens were produced. They were subjected to microtensile testing at a crosshead speed of 1.0 mm/minute. The results were analyzed using 2-way analysis of variance (ANOVA) followed by the Tukey HSD post-hoc test (alpha=0.05). Field-emission scanning electron microscopy (FE-SEM) observations of the adhesive-treated dentin surfaces and the resin/dentin interface were also conducted. The bond strengths of primary tooth dentin were significantly lower than that of permanent tooth dentin for both self-etch systems: 44.7 +/- 10.4 versus 54.3 +/- 9.0 MPa for Clearfil tri-S Bond and 40.6 +/- 9.9 versus 50.0 +/- 8.7 MPa for One-Up Bond F Plus (p<0.001). There was no statistically significant interaction between the type of adhesive system and the dentin substrate (p=0.957). Although there was no statistically significant difference in the mean values among the different adhesive systems (p=0.094), there was a statistically significant difference in mean values among the different dentin substrates (p<0.001), which were lower for primary tooth dentin than for permanent tooth dentin. The failure modes were also independent of the type of dentin but dependent on the adhesive systems, an equal distribution among the 3 types of failure for Clearfil tri-S Bond and cohesive failures in adhesives for One-Up Bond F Plus. FE-SEM observations of dentin to which adhesive had been applied revealed that the smear layer had been removed and the collagen fibers exposed. Though the bond strengths to primary tooth dentin were lower than to permanent tooth dentin, excellent adaptation of the single-step self-etch systems to both dentin substrates was observed by FE-SEM. Further studies are required to determine the long-term clinical performance of these adhesive systems when applied to primary tooth dentin.

Adhesives↗

Effect of air-drying time of single-application self-etch adhesives on dentin bond strength.

This study examined the effect of air-drying time of adhesives on the dentin bond strength of several single-application self-etch adhesive systems. The adhesive/resin composite combinations used were: Adper Prompt L-Pop/Filtek Z250 (AP), Clearfil Tri-S Bond/Clearfil AP-X (CT), Fluoro Bond Shake One/Beautifil (FB), G-Bond/Gradia Direct (GB) and One-Up Bond F Plus/Palfique Estelite (OF). Bovine mandibular incisors were mounted in self-curing resin and wet ground with #600 SiC to expose labial dentin. Adhesives were applied according to each manufacturer's instructions followed by air-drying time for 0 (without air-drying), 5 and 10 seconds. After light irradiation of the adhesives, the resin composites were condensed into a mold (phi4x2 mm) and polymerized. Ten samples per test group were stored in 37 degrees C distilled water for 24 hours; they were then shear tested at a crosshead speed of 1.0 mm/minute. One-way ANOVA followed by Tukey's HSD tests (alpha = 0.05) were done. FE-SEM observations of the resin/dentin interface were also conducted. Dentin bond strength varied with the different air drying times and ranged from 5.8 +/- 2.4 to 13.9 +/- 2.8 MPa for AP, 4.9 +/- 1.5 to 17.1 +/- 2.3 MPa for CT, 7.9 +/- 2.8 to 13.8 +/- 2.4 MPa for FB, 3.7 +/- 1.4 to 13.4 +/- 1.2 MPa for GB and 4.6 +/- 2.1 to 13.7 +/- 2.6 MPa for OF. With longer air drying of adhesives, no significant changes in bond strengths were found for the systems used except for OF. Significantly lower bond strengths were obtained for the 10-second air-drying group for OF. From FE-SEM observations, gaps between the cured adhesive and resin composites were observed for the specimens without the air drying of adhesives except for OF. The data suggests that, with four of the single-application self-etch adhesive systems, air drying is essential to obtain adequate dentin bond strengths, but increased drying time does not significantly influence bond strength. For the other system studied, the bond strength of the non-air dried group was not significantly different from the five second drying time, but prolonged drying was very detrimental to bond strength. For all five of the systems studied, a five-second air-drying time appeared to be appropriate.

Acrylic Resins↗