PubMed Health⌕ Search

Biomedical subjects

Kang-Ping Lin

Publications and source records attributed to Kang-Ping Lin.

2 recordsLinked to original sources

Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow method.

The purpose of this work was to develop and validate an automated method for intrathoracic tumour motion estimation from breath-hold computed tomography (BH CT) imaging using the three-dimensional optical flow method (3D OFM). A modified 3D OFM algorithm provided 3D displacement vectors for each voxel which were used to map tumour voxels on expiration BH CT onto inspiration BH CT images. A thoracic phantom and simulated expiration/inspiration BH CT pairs were used for validation. The 3D OFM was applied to the measured inspiration and expiration BH CT images from one lung cancer and one oesophageal cancer patient. The resulting displacements were plotted in histogram format and analysed to provide insight regarding the tumour motion. The phantom tumour displacement was measured as 1.20 and 2.40 cm with full-width at tenth maximum (FWTM) for the distribution of displacement estimates of 0.008 and 0.006 cm, respectively. The maximum error of any single voxel's motion estimate was 1.1 mm along the z-dimension or approximately one-third of the z-dimension voxel size. The simulated BH CT pairs revealed an rms error of less than 0.25 mm. The displacement of the oesophageal tumours was nonuniform and up to 1.4 cm, this was a new finding. A lung tumour maximum displacement of 2.4 cm was found in the case evaluated. In conclusion, 3D OFM provided an accurate estimation of intrathoracic tumour motion, with estimated errors less than the voxel dimension in a simulated motion phantom study. Surprisingly, oesophageal tumour motion was large and nonuniform, with greatest motion occurring at the gastro-oesophageal junction.

Algorithms↗

High frequency block of selected axons using an implantable microstimulator.

Currently, the majority of neural stimulation studies are limited to acute animal experiments due to lack of suitable implantable microstimulation devices. As an initial step to observe the long-term effects of neural stimulation, a system consisting of an external wireless controller and an implantable dual-channel microcontroller-based microstimulator for tripolar high frequency blocking was developed. The system is not only small in size, and thus suitable for short-term implantation, but also has sufficient current output parameter ranges to meet the demand for high frequency blocking experiments. Using this implantable microstimulator, a series of experiments were conducted on New Zealand rabbit's tibial nerve, including frequency and amplitude selection in driving stimulus and blocking effect tests, which were designed to assess the feasibility and efficiency of the device via torque measurements. Our results showed that the implantable microstimulator system gave a satisfactory performance and could be utilized to achieve selective stimulation and blocking on various sizes of nerve fibers. Our implantable microstimulation system is not only a novel tool for neuromuscular control studies but could also provide a basis for developing various types of sophisticated neural prostheses.

Animals↗