PubMed Health⌕ Search

Biomedical subjects

Kap No Lee

Publications and source records attributed to Kap No Lee.

9 recordsLinked to original sources

Improved sensitivity and physical properties of sol-gel protein chips using large-scale material screening and selection.

Protein chips are a powerful emerging technology with extensive biomedical applications. However, the development of optimal, economical surface materials capable of maintaining the activity of embedded proteins is a challenge. Here, we introduce a new optimized, low-cost, sol-gel biomaterial for use in protein chips with femtogram-level sensitivity. A novel protein chip material with significantly improved physical properties and sensitivity was produced using unique screening and selection methods. Using this platform, the sensitive, specific detection of the interactions between an HIV antigen and its antibody and between a cyclin-kinase protein pair was observed. This study is the first to demonstrate the detection of protein-protein interactions on sol-gel microarrays and describes an important improvement in the physical properties of sol-gel-derived protein chip materials for biomedical research.

Antibodies↗

Decrease in plasma adiponectin concentrations in patients with variant angina pectoris.

BACKGROUND: Plasma adiponectin is decreased in patients with coronary artery diseases, especially in patients with acute coronary syndrome (ACS). However, the correlation between plasma adiponectin and variant angina pectoris (VAP) has not been verified. Plasma adiponectin concentrations between VAP and other coronary artery diseases was compared in the present study. The association between plasma adiponectin concentration and VAP was also investigated. METHODS AND RESULTS: Plasma adiponectin concentrations in the VAP group (n=101) were compared with those of the ACS group (n=117), the stable angina pectoris group (n=108), and the normal coronary group (n=81). Plasma adiponectin concentrations in VAP and ACS were significantly lower than that of the normal coronary group (6.6+/-5.4 vs 5.2+/-4.0 vs 9.0 +/-6.2 microg/ml, p<0.001, respectively). Multivariate analysis indicated that plasma adiponectin (odds ratio (OR) 0.735, 95% confidence interval (CI) 0.621-0.855, p=0.011), smoking (OR 2.012, 95% CI 1.210-3.880, p=0.020), and age (OR 0.976, 95% CI 0.957-0.997, p=0.022) correlated independently with the development of VAP. CONCLUSIONS: Our results suggest that a decrease in plasma adiponectin concentration might be associated with the development of VAP.

Adiponectin↗

Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays.

Three fourth-generation antigen/antibody combination assays (Elecsys, AxSYM, Architect HIV) and two third-generation (AxSYM, Centaur) HIV antibody immunoassays were evaluated. The evaluation panel of 479 samples included: nine tissue culture derived HIV-1 strains at four different p24 antigen concentrations (n=36), a p24 antigen sensitivity panel (n=10), 149 HIV-1 or HIV-2 confirmed antibody positive samples, ten anti-HIV-1 positive low titer samples, three seroconversion panels (n=21), and 253 HIV negative samples. The Architect had the best sensitivity for detection of HIV-1 antigen across eight HIV-1 subtypes, followed by the AxSYM while the Elecsys could not detect the highest antigen concentration evaluated (25 pg/mL) for eight of nine virus isolates. All assays showed 100% sensitivity for detection of HIV-1, group M, group O, and HIV-2 antibody positive samples. The Architect Ag/Ab Combo assay detected the first positive bleed of the three seroconversion panels and detected infection 4-26 days earlier than the third generation assays. Based on evaluation of 253 negative samples, assay specificity varied from 98.0% to 99.6%. The Architect HIV Ag/Ab Combo exhibited the best performance for specificity and detection of p24 antigen leading to closure of seroconversion window and demonstrating its utility for early diagnosis of HIV infection.

Antigen-Antibody Complex↗

The genomic heterogeneity among Mycobacterium terrae complex displayed by sequencing of 16S rRNA and hsp 65 genes.

The species identification within Mycobacterium terrae complex has been known to be very difficult. In this study, the genomic diversity of M. terrae complex with eighteen clinical isolates, which were initially identified as M. terrae complex by phenotypic method, was investigated, including that of three type strains (M. terrae, M. nonchromogenicum, and M. triviale ). 16S rRNA and 65-kDa heat shock protein (hsp 65) gene sequences of mycobacteria were determined and aligned with eleven other references for the comparison using similarity search against the GenBank and Ribosomal Database Project II (RDP) databases. 16S rRNA and hsp 65 genes of M. terrae complex showed genomic heterogeneity. Amongst the eighteen clinical isolates, nine were identified as M. nonchromogenicum, eight as M. terrae, one as M. mucogenicum with the molecular characteristic of rapid growth. M. nonchromogenicum could be subdivided into three subgroups, while M. terrae could be subdivided into two subgroups using a 5 bp criterion (>1% difference). Seven isolates in two subgroups of M. nonchromogenicum were Mycobacterium sp. strain MCRO 6, which was closely related to M. nonchromogenicum. The hsp 65 gene could not differentiate one M. nonchromogenicum from M. avium or one M. terrae from M. intracellulare. The nucleotide sequence analysis of 16S rRNA and hsp 65 genes was shown to be useful in identifying the M. terrae complex, but hsp 65 was less discriminating than 16S rRNA.

Bacterial Proteins↗

Prevalence of antibodies to the circumsporozite protein of Plasmodium vivax in five different regions of Korea.

Malaria has recently re-emerged in the Republic of Korea (ROK), but only few malaria seroprevalences were reported. We obtained 1014 serum samples from inhabitants of five regions of ROK during the high transmission season between June and August in 2001. The levels of anti-circumsporozoite protein (CSP) antibody were assessed in samples using an indirect enzyme-linked immunosorbent assay (ELISA). The highest IgG seroreactivity against Plasmodium vivax recombinant CSP antigen was found among male residents of Cheolwon gun (13.5%), then Incheon (4.7%). The IgG seroreactivity from other regions ranged from 0.0% to 2.0%. These epidemiological data of seroprevalence in five regions of Korea showed a similar pattern to the annual incidence of malaria in these respective regions. The prevalence of antibodies increased with age, suggesting that the age and area-related prevalence patterns reflected differences in the inoculation rates between age groups and geographic regions. Seroprevalence and annual incidence were positively correlated in some areas of Korea.

Adolescent↗

Experience of the first survey of the pilot project of Asian Quality Assurance Survey program.

The Asian Network for Clinical Laboratory Standardization (ANCLS) decided to start her First Inter-laboratory Quality Assurance survey at the business meeting during the Second Asian Colloquium on October 21-22, 2000 in Kobe, Japan. The first survey materials of Asian Quality Assurance Survey (AQuAS) were distributed in July 2001 to 21 hospitals in the field of chemistry and 22 hospitals in the field of hematology among total 24 participating laboratories from seven Asian countries: Indonesia, Japan, Korea, Malaysia, Philippines, Singapore and Thailand. The survey methods in chemistry and in hematology were somewhat different. In chemistry the survey material was considered as unknown but handled similarly to the sample from the patient. Nineteen routine tests were performed only once. The hematology samples were considered as unknown but handled similarly to control or calibration material. Five parameters were tested five times repetitively and their average for each parameter was calculated. All the results were supposed to be sent back to the office within two weeks. Although it took more than two weeks, the return rate was 100%. The analysis was performed in several ways such as all the results together, by instruments and by methods. Mean, standard deviation (SD), standard deviation index (SDI), coefficient of variation (CV) and variance index score (VIS) were to be calculated in chemistry, and in hematology the same parameter were to be calculated except CV and VIS. In the first survey, the CV in chemistry was not calculated and the analysis by instrument or by methodology was also not attempted since there were not enough participating hospitals to do such analysis. In hematology the analysis was done by instrument only. The survey process was carried out successfully though there were some difficulties in communication tools, transportation methods and handling of specimens due to different weather conditions, and returning the report in the correct unit and to the correct place. The submitted data were acceptable for analysis. There were some differences in the units of measurement in different countries or laboratories. It was necessary to convert some of the units. Some laboratories apparently do not perform certain tests such as calcium, potasium and gamma-glutamyltransferase (gamma-GT). The gamma-GT is the most frequently not performed test. With the experience of this first survey, all the members involved in the survey have been trained well to do future surveys.

Asia↗

Clinical pathologist in Korea--training program and its roles in laboratories.

A rapid development of practice of laboratory medicine in Korea owes its success to the clinical pathologists (CP), who have played a role of a pathfinder for laboratories. The Korean CP postgraduate education (residency) program is unique in that it is exclusively for laboratory medicine. The training program for clinical pathologists includes diagnostic hematology, diagnostic immunology, clinical microbiology, clinical chemistry, blood bank, diagnostic genetics, informatics and laboratory management. The program has produced a strong group of about 600 laboratory physicians, officially clinical pathologists since 1963. Most of Korean clinical pathologists work as laboratory directors, directors of university hospital laboratories or teaching faculty members in medical schools. The roles of clinical pathologists are laboratory management, interpretation of laboratory test results, clinical consulting services to clinicians and patients, ordering secondary tests after reviews of requested test results and utilization management. The clinical pathologists have developed clinical laboratories to be a main contributor for improved medical practice. During the last 40 years under the turbulent healthcare system, clinical pathologists have significantly contributed to safeguard the laboratory interests. The education program and the role of clinical pathologists are described.

Curriculum↗