PubMed Health⌕ Search

Biomedical subjects

Karel Slais

Publications and source records attributed to Karel Slais.

17 recordsLinked to original sources

Capillary isoelectric focusing and fluorometric detection of proteins and microorganisms dynamically modified by poly(ethylene glycol) pyrenebutanoate.

The nonionogenic pyrene-based tenside, poly(ethylene glycol) pyrenebutanoate, was prepared and applied in capillary isoelectric focusing with fluorometric detection. This dye was used here as a buffer additive in capillary isoelectric focusing for a dynamic modification of the sample of proteins and microorganisms. The values of the isoelectric points of the labeled bioanalytes were calculated with use of the fluorescent pI markers and were found comparable with pI of the native compounds. The mixed cultures of proteins and microorganisms, Escherichia coli CCM 3954, Staphylococcus epidermidis CCM 4418, Proteus vulgaris, Enterococcus faecalis CCM 4224, and Stenotrophomonas maltophilia, the strains of the yeast cells, Candida albicans CCM 8180, Candida krusei, Candida parapsilosis, Candida glabrata, Candida tropicalis, and Saccharomyces cerevisiae were reproducibly focused and separated by the suggested technique. Using UV excitation for the on-column fluorometric detection, the minimum detectable amount was down to 10 cells injected on the separation capillary.

Bacteria↗

Capillary isoelectric focusing of proteins and microorganisms in dynamically modified fused silica with UV detection.

We suggest a method for the reproducible and efficient capillary isoelectric focusing of proteins and microorganisms in the pH gradient 3-10. The method involves the segmental injection of the simple ampholytes, the solution of the selected electrolytes, and the sample mixture of bioanalytes and carrier ampholytes to the fused silica capillaries dynamically modified by poly(ethylene glycol), PEG 4000, which is added to the catholyte, the anolyte and injected solutions. In order to receive the reproducible results, the capillaries were rinsed by the mixture of acetone/ethanol between analyses. For the tracing of the pH gradients the low-molecular-mass pI markers were used. The simple proteins and the mixed cultures of microorganisms, Saccharomyces cerevisiae CCM 8191, Escherichia coli CCM 3954, Candida albicans CCM 8180, Candida parapsilosis, Candida krusei, Staphylococcus aureus, Streptococcus agalactiae CCM 6187, Enterococcus faecalis CCM 4224, Staphylococcus epidermidis CCM 4418 and Stenotrophomonas maltophilia, were focused and separated by the method suggested. The minimum detectable number of microbial cells was 5x10(2) to 1x10(3) with on-column UV detection at 280 nm.

Bacteria↗

Changes in diffusion parameters, energy-related metabolites and glutamate in the rat cortex after transient hypoxia/ischemia.

It has been shown that global anoxia leads to dramatic changes in the diffusion properties of the extracellular space (ECS). In this study, we investigated how changes in ECS volume and geometry in the rat somatosensory cortex during and after transient hypoxia/ischemia correlate with extracellular concentrations of energy-related metabolites and glutamate. Adult male Wistar rats (n = 12) were anesthetized and subjected to hypoxia/ischemia for 30 min (ventilation with 10% oxygen and unilateral carotid artery occlusion). The ECS diffusion parameters, volume fraction and tortuosity, were determined from concentration-time profiles of tetramethylammonium applied by iontophoresis. Concentrations of lactate, glucose, pyruvate and glutamate in the extracellular fluid (ECF) were monitored by microdialysis (n = 9). During hypoxia/ischemia, the ECS volume fraction decreased from initial values of 0.19 +/- 0.03 (mean +/- S.E.M.) to 0.07 +/- 0.01 and tortuosity increased from 1.57 +/- 0.01 to 1.88 +/- 0.03. During reperfusion the volume fraction returned to control values within 20 min and then increased to 0.23 +/- 0.01, while tortuosity only returned to original values (1.53 +/- 0.06). The concentrations of lactate and glutamate, and the lactate/pyruvate ratio, substantially increased during hypoxia/ischemia, followed by continuous recovery during reperfusion. The glucose concentration decreased rapidly during hypoxia/ischemia with a subsequent return to control values within 20 min of reperfusion. We conclude that transient hypoxia/ischemia causes similar changes in ECS diffusion parameters as does global anoxia and that the time course of the reduction in ECS volume fraction correlates with the increase of extracellular concentration of glutamate. The decrease in the ECS volume fraction can therefore contribute to an increased accumulation of toxic metabolites, which may aggravate functional deficits and lead to damage of the central nervous system (CNS).

Animals↗

Capillary isoelectric focusing of microorganisms in the pH range 2-5 in a dynamically modified FS capillary with UV detection.

The isoelectric points of many microbial cells lie within the pH range spanning from 1.5 to 4.5. In this work, we suggest a CIEF method for the separation of cells according to their isoelectric points in the pH range of 2-5. It includes the segmental injection of the sample pulse composed of the segment of the selected simple ampholytes, the segment of the bioanalytes and the segment of carrier ampholytes into fused silica capillaries dynamically modified by poly(ethylene glycole). This polymer dissolved in the catholyte, in the anolyte and in the injected sample pulse was used for a prevention of the bioanalyte adsorption on the capillary surface and for the reduction of the electroosmotic flow. Between each focusing run, the capillaries were washed with the mixture of acetone/ethanol to achieve the reproducible and efficient CIEF. In order to trace of pH gradients, low-molecular-mass pI markers were used. The mixed cultures of microorganisms, Escherichia coli CCM 3954, Candida albicans CCM 8180, Candida parapsilosis, Candida krusei, Candida glabrata, Candida tropicalis, CCM 8223, Proteus vulgaris, Klebsiela pneumoniae, Staphylococcus aureus CCM 3953, Streptococcus agalactiae CCM 6187, Enterococcus faecalis CCM 4224 and Staphylococcus epidermidis CCM 4418, were focused and separated by the CIEF method suggested here. This CIEF method enables the separation and detection of the microbes from the mixed cultures within several minutes. The minimum detectable number of microbial cells was less than 10(3).

Electrophoresis, Capillary↗

Miniaturized liquid core waveguide-based fluorimetric detection cell for capillary separation methods: application in CE of amino acids.

A miniaturized post-column fluorimetric detection cell for capillary separation methods based on optical fibers and liquid core waveguides (LCWs) is described. The main part of the detection cell is a fused-silica capillary coated with Teflon AF serving as an LCW. The optical fibers are used both for coupling the excitation source with the detection domain in the LCW and for the axial fluorescence collection from the LCW end. The latter fiber is connected with a compact CCD spectrometer that serves for the rejection of the scattered excitation light and for the fluorescence signal detection. The proposed design offers a compact fluorescence detector for various microcolumn separation techniques without optical elements such as filters or objectives. Moreover, its construction and optical adjustment are very simple and the whole system is highly miniaturized. The function of the detection cell is demonstrated by CE of amino acids labelled by fluorescein-based tags. Separations of different standard amino acid mixtures and plasma samples are presented. The comparison of plasma amino acid levels of individuals being in good health with those of patients with inherited metabolic disorders is also shown.

Amino Acids↗

Mass spectrometric characterization of low-molecular-mass color pI markers and their use for direct determination of pI value of proteins.

The use of low-molecular-mass color pI markers for the determination of pI values of proteins in gel isoelectric focusing (IEF) in combination with mass spectrometry is described. Different types of substituted phenols of known pI values within the mass range 250-400 were used here as pI markers. The pure, synthesized pI markers were studied by MALDI-TOF/TOF MS. Fragmentation studies of the pI markers were also performed. Only stable and well-characterized pI markers were used in this work. The selected pI markers were mixed with proteins, deposited on a gel and separated in a pH gradient. Color pI markers enable supervision of progress of the focusing process and also estimation of the position of the invisible focused bands. The separated bands of the pI markers (containing separated proteins) were excised, and the pI markers were eluted from each gel piece by water/ethanol and identified by MALDI-TOF/TOF MS. From the washed gel pieces the remaining carrier ampholytes were then washed out and proteins were in-gel digested with trypsin. The obtained peptides were measured by MALDI-TOF/TOF MS and the proteins identified via a protein database search. This procedure allows avoiding time-consuming protein staining and destaining procedures, which shortens the analysis time roughly by half. For comparison, IEF gels were stained with Coomassie Brilliant Blue R 250 and proteins in the gel bands were identified according to the standard proteomic protocol. This work has confirmed that our approach can give information about the correct pI values of particular proteins and shorten significantly the time of analysis.

Color↗

Impact of cannabinoid receptor ligands on behavioural sensitization to antiaggressive methamphetamine effects in the model of mouse agonistic behaviour.

OBJECTIVES: Psychostimulants and cannabinoids can elicit so called behavioural sensitization after repeated administration, a gradually increased behavioural response to a drug. This phenomenon if conditioned by previous pre-treatment with different drug is termed cross-sensitization. The present study was focused on a possible sensitisation to antiaggressive effect of methamphetamine and cross-sensitization to this effect after repeated pre-treatment with cannabinoid CB1 and CB2 receptor ligands with different intrinsic activity (CB1 agonist methanandamide, CB2 agonist JWH 015, and CB1 antagonist AM 251). METHODS: Behavioural interactions of singly-housed mice with non-aggressive group-housed partners were video-taped and behavioural elements of agonistic behaviour of isolates were recorded in four categories: sociable, timid, aggressive and locomotor. RESULTS: Repeated administration of methamphetamine elicited a significant sensitization to its antiaggressive effects. Methanandamide pre-treatment provoked cross-sensitization to this methamphetamine effect, whereas pre-treatment with JWH 015 did not. Combined pre-treatment with methamphetamine+AM 251 suppressed the sensitization to antiaggressive effects of methamphetamine. CONCLUSIONS: Our findings have shown that it is possible to provoke sensitization not only to the stimulatory effects as stated widespread in the literature but also to inhibitory antiaggressive effects of methamphetamine. Furthermore, we confirmed our working hypothesis that it is possible to elicit either cross-sensitization to inhibitory effects of methamphetamine conditioned by repeated pre-treatment with cannabinoid CB1 receptor agonist methanandamide, or suppression of methamphetamine sensitizing influence by co-administration of CB1 receptor antagonist.

Agonistic Behavior↗

Fluorescence detection system for capillary separations utilizing a liquid core waveguide with an optical fibre-coupled compact spectrometer.

A fluorescence detection system for capillary liquid separation methods is described. The system is based on a silica capillary coated with a low refractive index fluoropolymer Teflon AF that serves both as a separation channel and as a liquid core waveguide (LCW). A fibre-coupled laser excites separated analytes in a detection point and arising fluorescence is collected at one end of the LCW capillary into the other optical fibre which brings it to a compact charge-coupled device (CCD) array spectrometer installed in a desktop computer. No additional components such as focusing optics or filters are necessary. This system was used for detecting isoelectrically focused fluorescent low-molecular-mass pI (isoelectric point) markers and fluorescein isothiocyanate (FITC) labelled proteins. The ability of the system to acquire fluorescent spectra is also demonstrated.

Calibration↗

Colored pI standards and gel isoelectric focusing in strongly acidic pH.

Colored, low molecular weight pI markers have been developed for isoelectric focusing (IEF) in acidic pH range. Their isoelectric points (pIs) were determined by direct measurement of the pH of the focused bands after completion of IEF on polyacrylamide gels. The practicable suitability of the proposed pI markers as pI standards for IEF was tested by applying gel IEF. The acidic pH gradient was created either by commercial synthetic carrier ampholytes or by mixture of simple buffers consisting of acids (non-ampholytes) and ampholytic buffers. By applying simple acids, it was possible to extend the acidic pH range beyond those achievable with commercial synthetic carrier ampholytes. By using an experimental arrangement without electrode electrolyte reservoirs with electrodes creating the fixed end of the gel, the strongly acidic pH gradient was stable even for prolonged focusing time.

Buffers↗

Dynamic modification of microorganisms by pyrenebutanoate for fluorometric detection in capillary zone electrophoresis.

Pyrenebutanoate, a fluorescent amphiphilic probe, is suggested here as a capillary zone electrophoresis (CZE) buffer additive for dynamic modification and analysis of microbial cells. Mixed cultures of microorganisms Escherichia coli, Candida albicans, Enterococcus faecalis and Staphylococcus epidermidis were concentrated, resolved by CZE and detected. Using UV excitation for on-column fluorometric detection, a detection sensitivity for the microorganisms on the order of from one to tens of injected cells was achieved.

Candida albicans↗

New azo dyes as colored isoelectric point markers for isoelectric focusing in acidic pH region.

Newly prepared azo compounds and several commercially available indicators were investigated for their applicability as colored isoelectric point (pI) markers for isoelectric focusing (IEF) in the acidic range below pH 5. The majority of compounds described here can serve as primary standards since their pI values were determined by UV-VIS spectrophotometry independently IEF and direct measurement with a pH electrode. Subjected to gel IEF they show narrow and well-observable zones of different colors. Finally, our work resulted in suggestion of a color ladder composed of pI markers covering the pH range from 1.5 to 4.7.

Azo Compounds↗

Two-dimensional gel isoelectric focusing.

Two-dimensional gel isoelectric focusing (2-D gel IEF) is presented as the combination of the same separation method used consecutively in two directions of the same gel. In this new method, after completion of IEF process in the first dimension the gel was cut into the separate strips, each containing selected analytes together with the appropriate part of the original broad pH gradient, and the strips were rotated by 90 degrees (with regard to the first IEF) and left to diffuse overnight. After diffusion the strips were subjected to the second IEF. During the second IEF, the corresponding narrow part of pH gradient in each strip was restored again, however, now along the strip. The progress of the separation process can be monitored visually by using colored low-molecular-weight isoelectric point (pI) markers loaded into the gel simultaneously with proteins. The unique properties of IEF, focusing and resolution power were enhanced by using the same technique twice. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31, respectively) non-separated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolution gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation of complex biological mixtures, similarly as other multidimensional separation techniques applied in proteomics, and can be followed by further processing, e.g., mass spectrometry analysis. The focusing properties of IEF could be useful especially in separation of mixtures, where components are at low concentration levels.

Electrophoresis, Gel, Two-Dimensional↗

Dynamics of gel isoelectric focusing with ampholytic dyes monitored by camera in real-time.

The dynamics of gel isoelectric focusing were studied by using amphoteric low-molecular-mass colored substances (isoelectric point markers). The polyacrylamide gel in slab format was in direct contact with the electrodes. In addition to isoelectric focusing with a pH gradient composed of synthetic carrier ampholytes, pH gradients created by simple buffers of acetic acid, 2-(N-morpholino)ethanesulfonic acid, histidine and N,N,N',N'-tetramethylethylenediamine were applied. The progress of the electrofocusing process was monitored by a charge-coupled device camera and video recording. The gradient profile and dynamics were approximated from the positions of isoelectric point markers, which were focused both on boundaries between individual zones of simple buffers and within the zones themselves. The obtained animated records enabled the observation of the entire real focusing run within fractions of a minute, which is useful both for the understanding and optimization of the focusing.

Buffers↗

Sol-gel column technology for capillary isoelectric focusing of microorganisms and biopolymers with UV or fluorometric detection.

The sol-gel surface modification is used for capillary isoelectric focusing of microorganisms and biopolymers. The coating strongly decreases the electroosmotic flow so that it enables the use of the short capillaries down to 100 mm in the separation length. The examples of capillary isoelectric focusing of the low-molecular-mass pI markers and mixed cultures of microbial populations of Escherichia coli, Candida albicans, Staphylococcus epidermidis, and Enteroccocus faecalis with UV detection are shown. It is possible to quantify bacterial cells according to their peak areas; the minimum detectable number of microbial cells was 5 x 10(2)-1 x 10(3). The compatibility of sol-gel capillaries with sensitive fluorometric detection of fluorescent pI markers together with fluorescein labeled proteins is demonstrated.

Bacteria↗

Pyrenebutanoate as a dynamic protein modifier for fluorometric detection in capillary zone electrophoresis.

Pyrenebutanoate as the amphiphilic fluorescent compound is suggested as a buffer additive in capillary zone electrophoresis (CZE) for a dynamic modification of several protein samples. Using deuterium lamp UV excitation for the on-column fluorometric detection, minimum detectable amounts in the amol-range of the proteins sampled on the CZE capillary was achieved.

Electrophoresis, Capillary↗

Fluorescein-based pI markers for capillary isoelectric focusing with laser-induced fluorescence detection.

We prepared a series of low-molecular-mass fluorescent ampholytes with narrow pI range. These fluorescein-based ampholytes are detection compatible with argon laser-induced fluorescence (LIF) detection. The selected properties, important for their routine use as fluorescent pI markers, were examined. The pI values of new fluorescein-based pI markers were determined by capillary isoelectric focusing (CIEF) using currently available low-molecular-mass pI markers for CIEF with photometric detection. The examples of CIEF with fluorometric detection of new compounds together with fluorescein isothiocyanate (FITC) derivatized proteins are presented.

Animals↗

Involvement of cannabinoid CB1 and CB2 receptor activity in the development of behavioural sensitization to methamphetamine effects in mice.

OBJECTIVES: An increased behavioural response ("behavioural sensitization") to drugs of abuse occurs after repeated treatment. In the present study the possibility of cross-sensitization existence between various cannabinoid receptor ligands--CB1 agonist methanandamide, CB2 agonist JWH 015, and CB1 antagonist AM 251 with methamphetamine was explored. METHODS: Locomotion in the open field was measured in naive mice and in those pre-treated acutely and repeatedly (for 8 days), respectively, with either vehicle or tested drugs. RESULTS: Methamphetamine produced significant sensitization to its stimulatory effect on locomotion. Methanandamide pre-treatment elicited cross-sensitization to methamphetamine effect, whereas pre-treatment with JWH 015 did not. Combined pre-treatment with methamphetamine+AM 251 suppressed sensitization to methamphetamine. CONCLUSIONS: These results suggest that the activity of the endocannabinoid system is involved in the neuronal circuitry underlying the development of sensitization to methamphetamine.

Animals↗