PubMed Health⌕ Search

Biomedical subjects

Karel Stulík

Publications and source records attributed to Karel Stulík.

12 recordsLinked to original sources

Monolithic organic polymeric columns for capillary liquid chromatography and electrochromatography.

This review briefly summarizes the present state of the preparation and use of capillary monolithic columns for liquid chromatography (LC) and electrochromatography (EC). Most important approaches to the preparation of monolithic stationary phases based on organic polymers are outlined and the properties of the monoliths obtained are compared with those of classical particulate phases. A few selected applications of monolithic columns are shown to demonstrate the most important advantages of monolithic capillary columns. It is concluded that both the monolithic and particulate capillary columns are important and that judicious choice of the type suitable for a particular application requires careful consideration of the purpose of the separation and the properties of the solutes to be separated. Monolithic columns are substantially younger than packed ones and thus will require further theoretical and experimental study to further improve their preparation and to enable reliable prediction of their properties and applicability; nevertheless, they are very promising for the future.

Chromatography, Micellar Electrokinetic Capillary↗

Influence of the spectrophotometric detection mode on the separation performance of systems with monolithic capillary columns: on-column and external-cell detection modes.

Poly(butyl methacrylate) monolithic columns were prepared by thermally initiated radical polymerization in fused-silica capillaries of 320 microm i.d. The prepared monolithic columns were tested by capillary liquid chromatography (CLC) combined with a UV-VIS spectrophotometric detector. The influence of the detection configuration (i.e., on-column and external-cell detection modes) on the performance of the chromatographic system was investigated. In the on-column detection mode within the monolith, the detection window was located inside the column section filled with the monolith. With the on-column detection configuration after the monolith, the detection window was positioned just behind the column section containing the monolith. Using the external-cell detection mode, an additional detection capillary, provided with a detection window defining the external-cell, was connected to the monolithic capillary column. These detection modes were critically compared in terms of the principal chromatographic parameters of the system involving the prepared monolithic capillary columns.

Chromatography, Liquid↗

Affinity liquid chromatography and capillary electrophoresis of seminal plasma proteins.

Interactions of boar, bull, and human seminal plasma proteins with heparin and phosphorylcholine were studied by affinity LC using heparin immobilized to a Toyopearl support. A step gradient elution from 0.15 to 1.50 M NaCl was employed to elute the seminal plasma proteins. Relative amounts of the heparin-binding fraction of seminal plasma proteins (H+) in seminal plasma of three species were determined. Further on, the fraction of seminal plasma proteins interacting with phosphorylcholine-binding proteins (P+) was evaluated. P+ proteins were not found in human seminal plasma and their highest amount was present in bull seminal plasma. A CE method was developed for separation of seminal plasma proteins. Various capillaries and separation conditions were tested; the best resolution was obtained in a bare-silica capillary, with a micellar system consisting of a 0.02 M borate buffer and 0.05 M SDS pH 10.0. The optimized conditions were applied to the identification of the components in boar plasma.

Animals↗

Preparation and testing of stationary phases and modified capillaries for affinity chromatography and affinity capillary electrophoresis of pepsin.

Three stationary phases have been prepared for affinity liquid chromatography isolation and separation of porcine and human pepsin. The phases contain 3,5-diiodo-L-tyrosine (DIT) bound to the supports HEMA BIO VS, HEMA BIO E and EPOXY TOYOPEARL. These phases have been tested on a model sample of porcine pepsin A and applied to human pepsin. Fractions have been collected and the chymase activity determined in selected analyses. For affinity CE, capillaries have been prepared by modifying the wall with 3-aminopropyltriethoxysilane, followed either by direct binding of DIT, or by binding L-tyrosine that was subsequently iodated. The dissociation constant K(d) has been determined for the pepsin-DIT complex from the changes in the electrophoretic mobilities.

Animals↗

Topographical properties of polymer films deposited in capillaries for electrophoretic separations of large organic molecules.

Topography and thickness of hydrophilic polymer coatings of fused-silica capillaries for capillary electrophoresis (CE) were investigated using atomic force microscopy (AFM), scanning electron microscopy (SEM), and profilometry. Three hydrogels, poly(2-hydroxyethyl methacrylate) [poly(HEMA)], poly(diethylene glycol monomethacrylate) [poly(DEGMA)], and poly(triethylene glycol monomethacrylate) [poly(TEGMA)], were deposited using two procedures, either by simple physical sorption of the polymers, or by derivatization of the capillary wall surface with glycidyl methacrylate (EPMA) followed by polymerization of the appropriate monomers. The performance of the modified capillaries was tested under CE conditions (decrease in the electroosmotic flow, EOF dependence on pH, separation of milk and standard proteins). It has been found that the most important property of the polymer coating is its thickness, whereas its topography and the degree of its hydrophobicity are less significant. Film deposition by physical adsorption is preferable to polymerization on the derivatized surface.

Adsorption↗

Dechlorination ability of municipal waste incineration fly ash for polychlorinated phenols.

Pathways of pentachlorophenol dechlorination have been investigated on municipal waste incineration fly ash at 200 degrees C under nitrogen atmosphere. Thermodynamic calculations have been carried out for these dechlorination conditions using the method of total Gibbs energy minimization for the whole system consisting of gaseous components, i.e., chlorinated phenols, phenol, hydrogen chloride and the Cu3Cl3 trimer and of solid Cu2O and CuCl2 components. The effects of water, temperature and of the amounts of the reaction components on the thermodynamic equilibrium have been discussed and the experimental results compared with the calculated thermodynamic data.

Carbon↗

Some potentialities and drawbacks of contemporary size-exclusion chromatography.

The present state of the chromatographic techniques based on differentiation of solutes according to their molecular sizes is briefly surveyed. Attention is centred on high-performance techniques applied to purification and characterization of natural macromolecules, and on discussion of the chromatographic approaches to the determination of the molecular masses and molecular mass distributions of both natural and synthetic polymers. The basic requirements on the selection of the separation system and the experimental conditions are summarized, demonstrated on a few examples and critically evaluated.

Biopolymers↗

Proteomics of allergens.

The present state of proteomics research is generally outlined and the character of allergenic compounds briefly elucidated. The principles of experimental approaches to isolation, purification, identification and characterization of allergens and to monitoring of their biological activity are described, with emphasis on the most modern methods. Selected examples are given for illustration and important results are summarized in tables.

Allergens↗

Methacrylate monolithic columns of 320 microm I.D. for capillary liquid chromatography.

Monolithic capillary columns (320 microm I.D.) were prepared for capillary liquid chromatography (CLC) by radical polymerization of butylmethacrylate (BMA) and ethylenedimethacrylate (EDMA) in the presence of a porogen solvent containing propan-1-ol, butane-1,4-diol and water. The influence of the contents of the porogen solvent and EDMA in the polymerization mixture on the monolith porosity and column efficiency was investigated. The composition of the polymerization mixture was optimized to attain a minimum HETP of the order of tens of microm for test compounds with various polarities. The separation performance and selectivity of the most efficient monolithic column prepared was characterized by van Deemter curves, peak asymmetry factors and Walters hydrophobicity and silanol indices. It was demonstrated that the 320-microm I.D. monolithic column exhibited CLC separation performance similar to that observed for 100- and 150-microm I.D. monolithic columns reported in the literature; moreover, the 320-microm I.D. column was easier to operate in CLC and exhibited a higher sample loadability.

Chromatography, Liquid↗

Modification of capillary electrophoresis capillaries by poly(hydroxyethyl methacrylate), poly(diethylene glycol monomethacrylate) and poly(triethylene glycol monomethacrylate).

Modification of capillary electrophoresis (CE) capillaries by poly(hydroxyethyl methacrylate) (poly(HEMA), poly(diethylene glycol monomethacrylate) (poly(DEGMA) and poly(triethylene glycol monomethacrylate) (poly(TEGMA), was studied. Methods based on physical adsorption of the modifier and on its chemical binding were compared on the basis of the electroosmotic flow (EOF) reproducibility, the EOF dependence on the pH, the symmetry of the peak of positively charged tyramine, the stability of the coating and the separation of standard and milk proteins in the modified capillaries. Reproducible coatings were obtained by chemical binding of the polymers to the capillary walls and by coating with a solution of a polymer, as also demonstrated by the atomic force microscopy.

Adsorption↗

A contactless conductivity detector for capillary electrophoresis: effects of the detection cell geometry on the detector performance.

The effect of the gap between the electrodes and of their width on the behavior of a capacitively wired contactless conductivity detector was studied. The results obtained have indicated that the detector response can be qualitatively described by a model based on the concept of the effective electrode width which is a complex parameter determined by the gap between the electrodes, the frequency of the input signal and the conductivity of the test solution. The detector sensitivity and the effect on the separation efficiency depend on the difference between the effective and geometric electrode widths. Higher detection sensitivities have been attained for detectors with wide electrodes operating at lower frequencies, however, better separation efficiencies have been achieved using detectors with narrow electrodes and higher operational frequencies. The noise increases with decreasing gap between the electrodes and increasing frequency, especially with detectors employing narrow electrodes.

Calibration↗