PubMed Health⌕ Search

Biomedical subjects

Karina Grundke

Publications and source records attributed to Karina Grundke.

5 recordsLinked to original sources

Influence of hyperbranched polyesters on the surface tension of polyols.

The influence of hyperbranched polyesters with different functional end groups on the surface tension of mixtures with an oligo(ester diol) was investigated. The temperature dependence of the surface tension of the pure components and of the mixtures was measured by a modified Wilhelmy balance technique. The results indicate that the surface tension of the pure hyperbranched polyesters strongly depends on the functionality of the end groups. The functionalization of the hydroxyl end groups by short alkyl chains (methyl, tert-butyl) reduced the surface tension depending on the degree of substitution. The surface tension of the mixtures with the hydroxyl-terminated hyperbranched polyester was slightly increased at higher concentrations of the hyperbranched polymer compared to the surface tension of the pure ester diol. On the other hand, the surface tension of mixtures could be considerably decreased using 1% of hyperbranched polyester polyols partially substituted with short alkyl chains. In that case, the modified hyperbranched polyesters act as surface active agents. On the molecular level, the enrichment of the modified hyperbranched polyester in the surface region was proven by X-ray photoelectron spectroscopy measurements.

Molecular Structure↗

Constrained sessile drop as a new configuration to measure low surface tension in lung surfactant systems.

Existing methodology for surface tension measurements based on drop shapes suffers from the shortcoming that it is not capable to function at very low surface tension if the liquid dispersion is opaque, such as therapeutic lung surfactants at clinically relevant concentrations. The novel configuration proposed here removes the two big restrictions, i.e., the film leakage problem that is encountered with such methods as the pulsating bubble surfactometer as well as the pendant drop arrangement, and the problem of the opaqueness of the liquid, as in the original captive bubble arrangement. A sharp knife edge is the key design feature in the constrained sessile drop that avoids film leakage at low surface tension. The use of the constrained sessile drop configuration in conjunction with axisymmetric drop shape analysis to measure surface tension allows complete automation of the setup. Dynamic studies with lung surfactant can be performed readily by changing the volume of a sessile drop, and thus the surface area, by means of a motor-driven syringe. To illustrate the validity of using this configuration, experiments were performed using an exogenous lung surfactant preparation, bovine lipid extract surfactant (BLES) at 5.0 mg/ml. A comparison of results obtained for BLES at low concentration between the constrained sessile drop and captive bubble arrangement shows excellent agreement between the two approaches. When the surface area of the BLES film (0.5 mg/ml) was compressed by about the same amount in both systems, the minimum surface tensions attained were identical within the 95% confidence limits.

Animals↗

Unusual wetting dynamics of aqueous surfactant solutions on polymer surfaces.

Static and dynamic contact angles of aqueous solutions of three surfactants--anionic sodium dodecyl sulfate (SDS), cationic dodecyltrimethylammonium bromide (DTAB), and nonionic pentaethylene glycol monododecyl ether (C(12)E(5))--were measured in the pre- and micellar concentration ranges on polymer surfaces of different surface free energy. The influence of the degree of substrate hydrophobicity, concentration of the solution, and ionic/nonionic character of surfactant on the drop spreading was investigated. Evaporation losses due to relatively low humidity during measurements were taken into account as well. It was shown that, in contrast to the highly hydrophobic surfaces, contact angles for ionic surfactant solutions on the moderately hydrophobic surfaces strongly depend on time. As far as the nonionic surfactant is considered, it spreads well over all the hydrophobic polymer surfaces used. Moreover, the results obtained indicate that spreading (if it occurs) in the long-time regime is controlled not only by the diffusive transport of surfactant to the expanding liquid-vapor interface. Obviously, another process involving adsorption at the expanding solid-liquid interface (near the three-phase contact line), which goes more slowly than diffusion, has to be active.

Journal Article↗

Two-level structured self-adaptive surfaces with reversibly tunable properties.

We report a route to fabricate two-level structured self-adaptive surfaces (SAS) of polymer materials. The first level of structure is built by a rough polymer film that consists of needlelike structures of micrometer size. The second level of structure is formed by the nanoscopic self-assembled domains of a demixed polymer brush irreversibly grafted onto the needles. By exposing the surface to solvents that are selective to one of the components of the brush, we reversibly tune the surface properties. The large-scale surface structure amplifies the response and enables us to control wettability, adhesion, and chemical composition of the surface over a wide range.

Journal Article↗

Suitability of hyperbranched polyester for sensoric applications--investigation with reflectometric interference spectroscopy.

Hyperbranched polyesters (HBP) with different end groups (P-OH, P-COOH, P-OAc) were prepared as thin films. Their surface properties were investigated using zeta potential and contact angle measurements. The differences in surface properties between P-OH and P-COOH, on the one hand, and P-OAc, on the other hand, predicted different behavior in sensoric applications. Therefore, the vapor of the homologous series of alcohols from methanol to pentanol was exposed to the thin films. Changes in thickness were observed with reflectometric interference spectroscopy (RIfS). First investigations in a current analytical problem for the detection and discrimination of refrigerants (freons) using P-OH as sensitive layer have been shown. Polydimethylsiloxane (PDMS) and poly(ether urethane) (PUT) were used as reference sensor materials for the RIfS measurements.

Journal Article↗