PubMed Health⌕ Search

Biomedical subjects

Karl Otto

Publications and source records attributed to Karl Otto.

7 recordsLinked to original sources

Direct aperture optimization for IMRT using Monte Carlo generated beamlets.

This work introduces an EGSnrc-based Monte Carlo (MC) beamlet does distribution matrix into a direct aperture optimization (DAO) algorithm for IMRT inverse planning. The technique is referred to as Monte Carlo-direct aperture optimization (MC-DAO). The goal is to assess if the combination of accurate Monte Carlo tissue inhomogeneity modeling and DAO inverse planning will improve the dose accuracy and treatment efficiency for treatment planning. Several authors have shown that the presence of small fields and/or inhomogeneous materials in IMRT treatment fields can cause dose calculation errors for algorithms that are unable to accurately model electronic disequilibrium. This issue may also affect the IMRT optimization process because the dose calculation algorithm may not properly model difficult geometries such as targets close to low-density regions (lung, air etc.). A clinical linear accelerator head is simulated using BEAMnrc (NRC, Canada). A novel in-house algorithm subdivides the resulting phase space into 2.5 X 5.0 mm2 beamlets. Each beamlet is projected onto a patient-specific phantom. The beamlet dose contribution to each voxel in a structure-of-interest is calculated using DOSXYZnrc. The multileaf collimator (MLC) leaf positions are linked to the location of the beamlet does distributions. The MLC shapes are optimized using direct aperture optimization (DAO). A final Monte Carlo calculation with MLC modeling is used to compute the final dose distribution. Monte Carlo simulation can generate accurate beamlet dose distributions for traditionally difficult-to-calculate geometries, particularly for small fields crossing regions of tissue inhomogeneity. The introduction of DAO results in an additional improvement by increasing the treatment delivery efficiency. For the examples presented in this paper the reduction in the total number of monitor units to deliver is approximately 33% compared to fluence-based optimization methods.

Algorithms↗

Secondary effects of femoral instrumentation on pulmonary physiology in a standardised sheep model: what is the effect of lung contusion and reaming?

Intramedullary nailing is the treatment of choice for patients with femoral shaft fractures. However, there is an ongoing debate in multiple trauma patients with associated lung contusion when primary or secondary definitive stabilisation of the long bone fracture should be performed, as nailing is thought to play an important role in the pathogenesis of adult respiratory distress syndrome (ARDS). In a standardised sheep model, this study aimed to quantify the development of acute pulmonary endothelial changes, to assess the activation of polymorphonuclear leucocytes (PMNL) and to observe the effects on the coagulation system associated with the reamed nailing procedure. Furthermore, the effect of coexisting lung contusion in an experimental model was evaluated. The animals were randomly assigned to one of four different groups (6 animals/group). In control groups, only a sham operation (thoracotomy) was performed, whereas in study groups, lung contusion was induced prior to femoral stabilisation either by external fixation or reamed femoral nailing. Using bronchoalveolar lavage (BAL) pulmonary permeability changes were quantified and PMNL activation was assessed by chemiluminescence. Additionally PMNL diapedesis and interstitial lung oedema were determined by histological analysis. All animals were sacrificed 4 h after the start of the femoral instrumentation. Without an associated lung injury, instrumentation of the femoral canal with the reamed nailing technique induced a transient increase in pulmonary permeability. In the face of an induced lung contusion, reamed femoral nailing resulted in significant increases in PMNL activation, pulmonary permeability and interstitial lung oedema, compared with external fixation. Without pulmonary contusion, reaming of the femoral canal was associated with a transient increase in pulmonary permeability. This was exacerbated in the presence of lung contusion along with increased PMNL activation. External fixation did not provoke similar changes. The findings of this study support the view that reaming of the femoral canal should be avoided in polytrauma patients with severe chest trauma as it could act as an additional stimulus for adverse outcome. Temporary external fixation appears to be a safe method for fracture stabilisation until inflammatory and coagulatory disturbances after trauma have been normalized.

Animals↗

The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapy.

Accurate measurements of the penumbra region are important for the proper modeling of the radiation beam for linear accelerator-based intensity modulated radiation therapy. The usual data collection technique with a standard ionization chamber artificially broadens the measured beam penumbrae due to volume effects. The larger the chamber, the greater is the spurious increase in penumbra width. This leads to inaccuracies in dose calculations of small fields, including small fields or beam segments used in IMRT. This source of error can be rectified by the use of film dosimetry for penumbra measurements because of its high spatial resolution. The accuracy of IMRT calculations with a pencil beam convolution model in a commercial treatment planning system was examined using commissioning data with and without the benefit of film dosimetry of the beam penumbrae. A set of dose-spread kernels of the pencil beam model was calculated based on commissioning data that included beam profiles gathered with a 0.6-cm-i.d. ionization chamber. A second set of dose-spread kernels was calculated using the same commissioning data with the exception of the penumbrae, which were measured with radiographic film. The average decrease in the measured width of the 80%-20% penumbrae of various square fields of size 3-40 cm, at 5 cm depth in water-equivalent plastic was 0.27 cm. Calculations using the pencil beam model after it was re-commissioned using film dosimetry of the penumbrae gave better agreement with measurements of IMRT fields, including superior reproduction of high dose gradient regions and dose extrema. These results show that accurately measuring the beam penumbrae improves the accuracy of the dose distributions predicted by the treatment planning system and thus is important when commissioning beam models used for IMRT.

Film Dosimetry↗

The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy.

Intensity modulated radiation therapy (IMRT) is used to deliver highly conformal radiation doses to tumors while sparing nearby sensitive tissues. Discrepancies between calculated and measured dose distributions have been reported for regions of high dose gradients corresponding to complex radiation fluence patterns. For the single pencil beam convolution dose calculation algorithm, the ability to resolve areas of high dose structure is partly related to the shape of the pencil beam dose kernel (similar to how a photon detector's point spread function relates to imaging resolution). Improvements in dose calculation accuracy have been reported when the treatment planning system (TPS) is recommissioned using high-resolution measurement data as input. This study proposes to improve the dose calculation accuracy for IMRT planning by modifying clinical dose kernel shapes already present in the TPS, thus avoiding the need to reacquire higher resolution commissioning data. The in-house optimization program minimizes a cost-function based on a two-dimensional composite dose subtraction/distance-to-agreement (gamma) analysis. The final modified kernel shapes are reintroduced into the treatment planning system and improvements to the dose calcula tion accuracy for complex IMRT dose distributions evaluated. The central kernel value (radius =0 cm) has the largest effect on the dose calculation resolution and is the focus of this study.

Algorithms↗

Enhancement of IMRT delivery through MLC rotation.

Multileaf collimator (MLC) based intensity modulated radiation therapy (IMRT) techniques are well established but suffer several physical limitations. Dosimetric spatial resolution is limited by the MLC leaf width; interleaf leakage and tongue-and-groove effects degrade dosimetric accuracy and the range of leaf motion limits the maximum deliverable field size. Collimator rotation is used in standard radiation therapy to improve the conformity of the MLC shape to the target volume. Except for opposed orthogonal fields, collimator rotation has not been exploited in IMRT due to the complexity of deriving the MLC leaf configurations for rotated sub-fields. Here we report on a new way that MLC-based IMRT is delivered which incorporates collimator rotation, providing an extra degree of freedom in deriving leaf sequences for a desired fluence map. Specifically, we have developed a series of unique algorithms that are capable of determining rotated MLC segments. These IMRT fields may be delivered statically (with the collimator rotating to a new position in between sub-fields) or dynamically (with the collimator rotating and leaves moving simultaneously during irradiation). This introductory study provides an analysis of the rotating leaf motion calculation algorithms with focus on radiation efficiency, the range of collimator rotation and number of segments. We then evaluate the technique by characterizing the ability of the algorithms to generate rotating leaf sequences for desired fluence maps. Comparisons are also made between our method and conventional sliding window and step-and-shoot techniques. Results show improvements in spatial resolution, reduced interleaf effects and maximum deliverable field size over conventional techniques. Clinical application of these enhancements can be realized immediately with static rotational delivery although improved dosimetric modelling of the MLC will be required for dynamic delivery.

Algorithms↗

Prostate brachytherapy postimplant dosimetry: a comparison of prostate quadrants.

PURPOSE: To investigate postimplant dosimetry for different regions of the prostate gland in patients treated with transperineal 125Iodine brachytherapy implants for low- and intermediate-risk prostate cancer. METHODS AND MATERIALS: Two hundred eighty-four patients treated with permanent interstitial prostate brachytherapy comprised the study population. A nonuniform, urethral-sparing algorithm was used to plan all patients. Prostate contours were outlined on postimplant CT images. Prostate volumes were then divided into four quadrants: anterior-superior quadrant (ASQ), posterior-superior quadrant (PSQ), anterior-inferior quadrant (AIQ), and posterior-inferior quadrant (PIQ). Dose-volume histograms (DVHs) were calculated for the whole prostate and each quadrant. RESULTS: The mean postimplant V(100) +/- 95% confidence (the percent prostate volume encompassed within the isodose surface comprising the prescription dose = 144 Gy) for the ASQ was 78.5 +/- 1.9, which was significantly lower than that of the PSQ, AIQ, and PIQ in which the V(100) plus minus 95% confidence values were 94.9 +/- 0.8, 92.6 +/- 1.2, and 98.7 +/- 0.3, respectively. The mean V(100) +/- 95% confidence for the whole prostate was 90.4 +/- 0.8. Mean values for V(150) and D(90) (the minimum dose in Gy received by 90% of the target volume) for the four quadrants and the whole prostate showed similar results. CONCLUSIONS: Underdosed areas of the planning target volume (PTV), if present, were largely confined to the ASQ, which received a significantly lower dose, on average, compared to the other three quadrants of the prostate.

Aged↗

Exploring the limits of spatial resolution in radiation dose delivery.

Flexibility and complexity in patient treatment due to advances in radiotherapy techniques necessitates a simple method for evaluating spatial resolution capabilities of the dose delivery device. Our purpose in this investigation is to evaluate a model that describes the ability of a radiation therapy device to deliver a desired dose distribution. The model is based on linear systems theory and is analogous to methods used to describe resolution degradation in imaging systems. A qualitative analysis of spatial resolution degradation using the model is presented in the spatial and spatial frequency domains. The ability of the model to predict the effects of geometric dose conformity to treatment volumes is evaluated by varying multileaf collimator leaf width and magnitude of dose spreading. Dose distributions for three clinical treatment shapes, circular shapes of varying diameter and one intensity modulated shape are used in the evaluation. We show that the model accurately predicts the dependence of dose conformity on these parameters. The spatial resolution capabilities of different radiation therapy devices can be quantified using the model, providing a simple method for comparing different treatment machine characteristics. Also, as different treatment sites have different resolution requirements this model may be used to tailor machine characteristics to the specific site.

Brain↗