Towards pointwise motion tracking in echocardiographic image sequences--comparing the reliability of different features for speckle tracking.

In this paper, we studied the problem of feature-based motion tracking in echocardiographic image sequences. We described the relation between possible feature variations and different kinds of tissue motion using a linear convolution model. We also showed that motion-feature decorrelation (which means that the motion parameters estimated using feature tracking fail to represent the underlying tissue motion) compensation is an ill-posed inverse problem. Instead of finding a method that may provide better compensation results than previous approaches, we used an quantitative measure to compare the reliability of tracking features. Experiment results showed that the use of the reliability measure improved the robustness of displacement estimation. With the help of the reliability measure, we compared the performance of different features using simulations and phantom examples. While we noticed that the radio frequency (RF) signal outperforms the B-mode (BM) signal in the analysis of small deformation (e.g., less than 0.1% compression), we also found out that the BM signal works better than the RF signal in the analysis of large deformation (e.g., larger than 2% compression). The use of a band-passed filtered feature does not result in significant improvement in tracking.

Algorithms↗

Use of real-time 3-dimensional transthoracic echocardiography in the evaluation of mitral valve disease.

Three-dimensional (3D) echocardiography (3DE) provides unique orientations of the mitral valve (MV) not obtainable by routine 2-dimensional echocardiography. However, this modality has not been adopted in routine clinical practice because of its cumbersome and time-consuming process. The recent introduction of a full matrix-array transducer has enabled online real-time 3DE (RT3DE) and rendering. This study was designed to: (1) determine the clinical use of RT3DE in patients with MV pathology and in a control group selected for their good acoustic windows (protocol I); and (2) to investigate the feasibility of imaging the MV apparatus in a large group of consecutively imaged patients to determine the acoustic window or perspective from which the MV leaflets, commissures, and orifice are best visualized (protocol II). In protocol I, 65 patients were selected based on MV pathology and good 2-dimensional echocardiography image quality. Protocol II included 150 patients who were consecutively imaged using RT3DE. Images were viewed online (protocol I) and offline on a digital review station (protocol II). RT3DE visualization of the MV apparatus was graded based on the percentage of leaflet dropout and definition. In protocol I, 78% of patients had adequate 3D MV reconstructions with complete visualization of the anterior mitral leaflet (AML) in 84% versus the posterior mitral leaflet (PML) in 77%. The mitral leaflets, commissures, and MV orifice were well seen in 98%; however, the submitral apparatus was only observed in 76% of the patients. RT3DE: (1) correctly identified the prolapsed/flailed scallop in 6 of 8 patients; (2) obtained en face orientation of the MV orifice in 9 of 11 patients with mitral stenosis, allowing accurate measurements of the orifice area and evaluation of the immediate effects of balloon mitral valvuloplasty; and (3) allowed postoperative evaluation of MV repair and the integrity of the struts of a bioprosthetic leaflet. In protocol II, 70% of patients had adequate RT3DE with complete visualization of the AML noted in 55% versus 51% for PML. The mitral leaflets, commissures, and MV orifice were observed in 69%. Irrespective of acquisition window, the AML was best seen from a ventricular perspective. In contrast, the PML was optimally examined from a parasternal window. Both the medial and lateral commissures were equally assessed from either imaging window. In conclusion, RT3DE of the MV is feasible in a large majority of patients. Using different MV acquisitions RT3DE provides important clinical information such as: (1) identification of a prolapsed/flail scallop; (2) measurement of stenotic valve areas; (3) evaluation of MV leaflet integrity postrepair; and (4) identification of a MV perforation. In general the AML is better visualized than the PML. The parasternal window is the optimal approach to visualize both AML and PMLs.

Computer Systems↗

Real-time three-dimensional color Doppler echocardiography overcomes the inaccuracies of spectral Doppler for stroke volume calculation.

Real-time 3-dimensional echocardiography is increasingly used in clinical cardiology. Studies have been shown that this technique can be accurately used to assess both cardiac mass and chamber volumes. We review the work showing that real-time 3-dimensional Doppler echocardiography can be used to accurately calculate intracardiac flow volumes that can potentially be used to assess cardiac function, intracardiac shunt, and valve regurgitation.

Computer Systems↗

A novel method for the assessment of the accuracy of computing laminar flow stroke volumes using a real-time 3D ultrasound system: In vitro studies.

AIMS: Laminar flow stroke volume (SV) quantification in the ascending aorta or pulmonary artery can provide a measure for determining cardiac output (CO). Comparing flows across different valves can also compute shunt volumes and regurgitant fractions. Quantification methods for 3D color Doppler laminar flow volumes have been developed using reconstructive 3D, but these are cumbersome and time-consuming both in acquisition and measurement. Our study evaluated newly developed color Doppler mapping with real-time live 3D echo to test velocity, spatial and temporal resolution for computing SV. METHODS AND RESULTS: Five rubber tubes (diameters=3.0, 2.25, 2.0, 1.9, 1.7 cm), a freshly dissected porcine aorta (Ao) and a pulmonary artery (PA) (both 2-3 cm diameter) were connected to a pulsatile pump in a water bath. Different SV, from 10 to 80 ml/beat, were studied at pump rates of 40-60 bpm in this phantom model with flow quantified by timed collection. The Nyquist limit was set between 43 and 100 cm/s and frame rate ranged from 14 to 23/s. ECG triggered 3D color Doppler volumes were acquired with a 2-4 MHz probe. The digital scan line data from the 3D volumes, with retained velocity assignments, was exported and analyzed offline by MatLab custom software. Close correlations were found between 3D calculated SV and reference data for all tubes (r=0.98, y=1.14x-1.69, SEE=2.82 ml/beat, p<0.0001). Both Ao and PA flows were also highly correlated with the reference measurements (PA: r=0.98, SEE=3.17 ml/beat; Ao: r=0.99, SEE=3.20 ml/beat). CONCLUSIONS: Real-time 3D color Doppler method could provide an efficient, accurate and reliable method for clinical evaluation and quantification of flow volumes in patients.

Animals↗

The use of live three-dimensional Doppler echocardiography in the measurement of cardiac output: an in vivo animal study.

OBJECTIVES: The purpose of this study was to investigate whether cardiac output (CO) could be accurately computed from live three-dimensional (3-D) Doppler echocardiographic data in an acute open-chested animal preparation. BACKGROUND: The accurate measurement of CO is important in both patient management and research. Current methods use invasive pulmonary artery catheters or two-dimensional (2-D) echocardiography or esophageal aortic Doppler measures, with the inherent risks and inaccuracies of these techniques. METHODS: Seventeen juvenile, open-chested pigs were studied before undergoing a separate cardiopulmonary bypass procedure. Live 3-D Doppler echocardiography images of the left ventricular outflow tract and aortic valve were obtained by epicardial scanning, using a Philips Medical Systems (Andover, Massachusetts) Sonos 7500 Live 3-D Echo system with a 2.5-MHz probe. Simultaneous CO measurements were obtained from an ultrasonic flow probe placed around the aortic root. Subsequent offline processing using custom software computed the CO from the digital 3-D Doppler DICOM data, and this was compared to the gold standard of the aortic flow probe measurements. RESULTS: One hundred forty-three individual CO measurements were taken from 16 pigs, one being excluded because of severe aortic regurgitation. There was good correlation between the 3-D Doppler and flow probe methods of CO measurement (y = 1.1x - 9.82, R(2) = 0.93). CONCLUSIONS: In this acute animal preparation, live 3-D Doppler echocardiographic data allowed for accurate assessment of CO as compared to the ultrasonic flow probe measurement.

Animals↗

Real-time three-dimensional echocardiography using a novel matrix array transducer.

Three-dimensional echocardiography has multiple advantages over two-dimensional echocardiography, such as accurate left ventricular quantification and improved spatial relationships. However, clinical use of three-dimensional echocardiography has been impeded by tedious and time-consuming methods for data acquisition and post-processing. A newly developed matrix array probe, which allows real-time three-dimensional imaging with instantaneous on-line volume-rendered reconstruction, direct manipulation of thresholding, and cut planes on the ultrasound unit may overcome the aforementioned limitations. This report will review current methods of three-dimensional data acquisition, emphasizing the real-time methods and clinical applications of the new matrix array probe.

Echocardiography, Three-Dimensional↗