Solvent and temperature gradients in separation of synthetic oxyethylene-oxypropylene block (co)polymers using high-temperature liquid chromatography.

Chromatographic behavior of synthetic block (co)oligomer samples (EO)n(PO)m(EO)n and (PO)n(EO)m(PO)n with different distribution of propylene oxide (PO) and ethylene oxide (EO) monomer units was investigated on three types of stationary phases on zirconium dioxide support: Zr-PS (polystyrene), Zr-carbon, and Zr-carbon C18. The effects of the distribution and sequence of the oxyethylene and oxypropylene monomer units on the chromatographic retention depend on the type of the stationary phase, but are strongly affected by the organic modifier (methanol or ACN) in aqueous-organic mobile phase. Special attention was focused on the influence of the mobile-phase composition on the separation according to the EO and PO distribution. Zirconia-based columns are stable at elevated temperatures and can be used in high-temperature LC (HTLC); hence, we investigated the temperature effects on the chromatographic behavior up to 90 degrees C. The applications of solvent and temperature gradients were compared on the zirconia stationary phases in the RP mode.

Carbon↗

Retention and selectivity tests of silica-based and metal-oxide bonded stationary phases for RP-HPLC.

Chromatographic properties of silica-, zirconia- and alumina-based columns with octadecyl-, polyethylene glycol- and pentafluorophenylpropyl-bonded stationary phases were tested. Selectivities of nine columns for LC were characterized using chromatographic methods including Walters, Engelhardt, Tanaka and Galushko hydrophobicity and silanol activity tests, measurements of methylene selectivity in various aqueous-methanol and aqueous-acetonitrile mobile phases and of gradient lipophilic capacity as a measure of the effect of the sample hydrophobicity on gradient-elution separations. A semi-empirical interaction indices model, assuming a predominant role of the solvophobic interactions of test compounds with different polarities, was compared with the linear free energy relationships approach taking into account selective polar interactions. The interaction indices model was applied to both non-polar stationary phases bonded on silica, alumina and zirconia supports, and to the non-modified adsorbents in the normal-phase LC. The retention data of isomeric naphthalene disulfonic acids were used to compare the attractive and repulsive ionic interactions of the columns in purely aqueous mobile phases. The results of the hydrophobicity and polarity tests were consistent, and allowed column characterization and classification. Silanol activity was important with octadecyl silica columns, but was relatively insignificant with bonded polyethylene glycol and pentafluorophenylpropyl phases on silica gel support. Polar interactions with the alumina and zirconia support materials significantly affect the retention.

Journal Article↗

Two-dimensional liquid chromatography normal-phase and reversed-phase separation of (co)oligomers.

Many samples contain compounds with various numbers of two or more regular structural groups. Such "multidimensional" samples (according to the Giddings' notation) are best separated in orthogonal chromatographic systems with different selectivities for the individual repeat structural groups, described by separation factors. Correlations between the repeat group selectivities characterize the degree of orthogonality and suitability of chromatographic systems for two-dimensional (2D) separations of two-dimensional samples. The range of the structural units in that can be resolved in a given time can be predicted on the basis of a model describing the repeat group selectivity in the first- and second-dimension systems. Two-dimensional liquid chromatographic system combining reversed-phase (RP) mode in the first dimension and normal-phase (NP) mode in the second dimension were studied with respect to the possibilities of in-line fraction transfer between the two modes. Hydrophilic interaction liquid chromatography (HILIC) with an aminopropyl silica column (APS) is more resistant than classical non-aqueous NP systems against adsorbent desactivation with aqueous solvents transferred in the fractions from the first, RP dimension to the second dimension. Hence, HILIC is useful as a second-dimension separation system for comprehensive RP-NP LCxLC. A comprehensive 2D RP-NP HPLC method was developed for comprehensive 2D separation of ethylene oxide-propylene oxide (EO-PO) (co)oligomers. The first-dimension RP system employed a 120 min gradient of acetonitrile in water on a C18 microbore column at the flow-rate of 10 microL/min. In the second dimension, isocratic HILIC NP with ethanol-dichloromethane-water mobile phase on an aminopropyl silica column at 0.5 mL/min was used. Ten microliter fractions were transferred from the RP to the HILIC NP system at 1 min switching valve cycle frequency.

Acetonitriles↗

Phase system selectivity and two-dimensional separations in liquid column chromatography.

Correlations between the separation selectivity in aqueous and non-aqueous reversed-phase systems and in normal-phase LC systems were investigated for samples containing different numbers of two repeat structural elements. Such samples are best separated in "orthogonal" two-dimensional chromatographic systems, showing selectivity for one type of the repeat structural element only in the first dimension and for the other structural element only in the second dimension. The number of resolved compounds improves as the degree of orthogonality of the separation systems increases with decreasing correlation between the selectivities for the sample structural distribution in the two dimensions. Orthogonal systems with non-correlated selectivities for each repeat structural element provide the highest number of separated peaks and regular arrangement of the peaks over the two-dimensional retention space according to the individual structural element distribution and the best use of the available peak capacity. Fully orthogonal systems are difficult to find in practice. Partially orthogonal system with correlated selectivities for one structural type distribution, but with one system non-distinguishing the distribution for the other structural element are still useful for the two-dimensional separations. The correlations between the selectivities for repeat regular structural increments were employed to evaluate the suitability of phase systems for two-dimensional HPLC separations. The selectivity correlation in various reversed-phase and normal-phase systems was evaluated for two sample types: (1) Various RP columns show significantly inversely correlated selectivities for acyl lengths and numbers of double bonds distribution, but the differences in the double bond selectivity can be used for practical separations of triacylglycerols with the same equivalent carbon numbers. (2) Synthetic EO-PO block (co)oligomers with two-dimensional distribution of oxyethylene and oxypropylene monomer units were separated according to the two distribution types using on-line two-dimensional reversed-phase-normal-phase LC with a C18 column in the first dimension and an aminopropyl silica column in the second dimension.

Chromatography, Liquid↗

Comparative characteristics of HPLC columns based on quantitative structure-retention relationships (QSRR) and hydrophobic-subtraction model.

The study was aimed at quantitative comparison of retention properties of modern stationary phases for reversed-phase HPLC. Three approaches, the calculated logarithm of octanol/water partition coefficient (clogP)-based model, the molecular modeling descriptors-based model and the hydrophobic-subtraction model, were compared and discussed. Gradient retention time, tR, of a series of test analytes was a dependent variable in the quantitative structure-retention relationship (QSRR) equations describing retention in terms of analytes' structure descriptors. The QSRRs derived were used to characterize in quantitative manner the specific retention properties of nine representative reversed-phase HPLC. Either the theoretically calculated logarithm of octanol/water partition coefficient, or the structural descriptors from molecular modeling were employed to quantitatively characterize the structure of the analytes. The three molecular modeling-derived structural descriptors considered were: the total dipole moment, the electron excess charge of the most negatively charged atom and the water-accessible molecular surface area. In addition to the above standard QSRR approaches, a recently developed parameterization of reversed-phase column selectivity based on the hydrophobic-subtraction model of Snyder et al. [L.R. Snyder, J.W. Dolan, J.W. Carr, The hydrophobic-subtraction model of reversed-phase column selectivity, J. Chromatogr. A 1060 (2004) 77] was considered. According to the hydrophobic-subtraction model, reversed-phase columns are characterized by five selectivity parameters derived from the linear solvation energy relationships (LSER) theory. Values of these parameters are available for more than 300 different columns. It has been demonstrated that the clogP-based model, the molecular modeling descriptors-based model and the hydrophobic-subtraction model provide generally similar classification of the HPLC columns studied. Some differences in column classification by the three approaches considered are discussed in terms of specific properties of individual stationary phases. All the approaches allow a quantitative, although multidimensional, characteristic of HPLC columns, however, the nonempirical QSRR-based approach is simpler and require less labor.

Chromatography, High Pressure Liquid↗

Naphthalene sulphonic acids--new test compounds for characterization of the columns for reversed-phase chromatography.

Non-substituted naphthalene sulphonic acids are strong acids, which are completely ionised in aqueous and aqueous-organic solutions. Because of repulsive electrostatic interactions, they are more or less excluded from the pores of the column packing materials commonly used in reversed-phase chromatography. The ionic exclusion can be suppressed by increasing the ionic strength of the mobile phase. In aqueous sodium sulphate solutions, very good selectivity was observed for isomeric naphthalene di- and tri-sulphonic acids, allowing reversed-phase separations of these strongly ionic compounds without addition of ion-pairing reagents to the mobile phase. The retention of the isomeric acids increases proportionally to the dipole moment, which can be explained by its effect on increasing exposure of the naphthalene ring to hydrophobic interactions with the non-polar stationary phases. Chromatographic behaviour of isomeric naphthalene di- and trisulphonic acids was investigated on 25 different columns for reversed-phase chromatography. The elution order of the isomers is the same on all the columns, but very strong stationary phase effects were observed on the retention and on the band asymmetry, depending on polar interactions with residual silanol groups and other polar adsorption centres in the stationary phases. These effects are independent of the organic solvents, as the tests are performed in purely aqueous mobile phases and allow classification of the columns into several groups.

Chromatography, High Pressure Liquid↗

Stationary-phase effects in gradient high-performance liquid chromatography.

The type of the stationary phase for reversed-phase liquid chromatography significantly affects the sample polarity range that can be covered using gradients of organic solvents in water. The polarity range available for gradient separations of samples containing compounds differing in the lipophilic parts of the molecules can be characterized by "gradient lipophilic capacity", Pl, based on the retention of standard compounds with a repeat lipophilic structural unit, such as a methylene group. The gradient lipophilic capacity is also suitable to characterize the separation possibilities of the columns in non-aqueous reversed-phase gradient elution of strongly non-polar compounds, such as triacylglycerols. In the same way, the suitability of various columns for reversed-phase gradient separations of oligomers can be characterized by "gradient oligomer capacity", as demonstrated in the example of oligo(ethylene glycols). To enable a comparison of the properties of stationary phases independent of column efficiency and dimensions, the gradient lipophilic capacity or the gradient oligomer capacity should be normalized for a "standard" column plate number, gradient range and volume (in column hold-up volume units). The gradient lipophilic capacity or the gradient oligomer capacity and the number of compounds that can be resolved during a gradient run decrease as the initial concentration of the strong solvent in the mobile phase increases and (or) the gradient time decreases. These quantities can be used to select a suitable column and to adjust the optimum gradient profile (the initial composition of the mobile phase and the gradient steepness) with respect to the time of analysis and the number of oligomers or other compounds with regular repeat structural groups that can be resolved during the gradient run.

Chromatography, High Pressure Liquid↗