PubMed Health⌕ Search

Biomedical subjects

Katharina Marten

Publications and source records attributed to Katharina Marten.

13 recordsLinked to original sources

Computer-aided detection and automated CT volumetry of pulmonary nodules.

With use of multislice computed tomography (MSCT), small pulmonary nodules are being detected in vast numbers, constituting the majority of all noncalcified lung nodules. Although the prevalence of lung cancers among such lesions in lung cancer screening populations is low, their isolation may contribute to increased patient survival. Computer-aided diagnosis (CAD) has emerged as a diverse set of diagnostic tools to handle the large number of images in MSCT datasets and most importantly, includes automated detection and volumetry of pulmonary nodules. Current CAD systems can significantly enhance experienced radiologists' performance and outweigh human limitations in identifying small lesions and manually measuring their diameters, augment observer consistency in the interpretation of such examinations and may thus help to detect significantly higher rates of early malignomas and give more precise estimates on chemotherapy response than can radiologists alone. In this review, we give an overview of current CAD in lung nodule detection and volumetry and discuss their relative merits and limitations.

Adult↗

Pulmonary embolism at multi-detector row CT of chest: one-year survival of treated and untreated patients.

PURPOSE: To retrospectively assess outcome in patients with clinically unsuspected pulmonary embolism (PE) at chest multi-detector row computed tomography (CT). MATERIALS AND METHODS: Institutional review board approval and informed consent were not required. PE was assessed in consecutive CT scans in 1966 patients (mean age, 60 years; range, 15-96 years; male-female ratio, 1.79) and graded with severity score. Studies with true-positive and false-negative radiologic diagnoses were determined. Coexisting morbidity, anticoagulant therapy (ACT), complications, and 1-year outcome were reviewed. Statistical evaluation included Mann-Whitney U test, chi(2) test, Poisson regression, and Kaplan-Meier statistics. RESULTS: Scans were PE positive in 117 patients. Clinical data review was complete in 96 patients; 63 of 96 patients had malignancy; in 58, PE was not suspected. In 38 of these 58 patients, radiology report findings were false-negative (mean severity score, 20.21 +/- 17.88 [standard deviation] and 9.55 +/- 7.12 for those with true-positive and false-negative findings, respectively; P = .012). Forty-nine patients received therapeutic ACT; 21, prophylactic ACT; and 26, no treatment. PE severity was higher in patients with therapeutic ACT versus those without (P < .001). Bleeding complications were more frequent with therapeutic ACT (two early deaths, five major nonfatal hemorrhages) than without (one minor hemorrhage; P = .037). There were eight early deaths (therapeutic ACT, seven; without ACT, one; P = .037). Positive predictors of early death included severity score >28, use of systemic thrombolytic therapy, occurrence of major hemorrhage, and new-onset cardiac or renal failure (P = .001-.043). Negative predictors were report with false-negative findings and no therapeutic ACT (P = .007-.037). Predictors of late death (n = 25) were older age, malignancy, and renal failure (P = .001-.043). CONCLUSION: Clinically unsuspected PE may remain undetected at routine chest CT; these patients have favorable short-term outcome without therapeutic ACT.

Adolescent↗

Acute pulmonary embolism on MDCT of the chest: prediction of cor pulmonale and short-term patient survival from morphologic embolus burden.

OBJECTIVE: To predict cor pulmonale and short-term outcome in patients with pulmonary embolism (PE), we retrospectively investigated three morphology-based MDCT systems for scoring pulmonary artery obstruction. MATERIALS AND METHODS: Eighty-nine consecutive patients (51 men and 38 women; age range, 23-83 years; median, 63.3 years) with an MDCT diagnosis of acute PE were included in the study. Sixty-four patients had a coexisting malignancy. PE severity was assessed by two masked observers using three percentage arterial obstruction indexes: two severity scores adapted from conventional angiography (excluding and including arterial branch obstruction grading: scores A and B, respectively) and a CT-derived severity score (index C). Echocardiographic reports were reviewed for elevation of right ventricular pressure. Obstruction index results were analyzed for correlation with pulmonary artery pressures and for prediction of cor pulmonale and 30-day survival. Statistical analysis included kappa, analysis of variance, linear correlation, chi-square, and logistic regression tests. RESULTS: Kappa values of 0.89, 0.82, and 0.78 were obtained for interobserver agreement on PE severity for indexes A, B, and C, respectively. PE severity was moderate but varied significantly between the scores (for index A: median, 25.0%; range, 6.3-100; for index B: median, 12.5%; range, 3.1-65.6; for index C: median, 7.1%; range, 0.65-65.8; p < 0.0001 [analysis of variance]). Index C correlated best with pulmonary artery pressures (r = 0.69; p < 0.0016) and the presence of cor pulmonale (p = 0.0051; odds ratio [OR], 1.20/percentage increase [95% confidence interval, 1.05-1.35]; for an index C cutoff of 21.3%: p = 0.0001; positive predictive value, 1; negative predictive value, 0.87). Eight patients died within 30 days after CT. The PE severity of indexes A and B was not associated with patient outcome (p > 0.05). With score C, PE severity was a significant predictor of early death (p = 0.018; OR, 1.03/percentage increase [95% confidence interval, 1.00-1.06]; for an index C cutoff of 21.3%: p = 0.018; overall OR, 6.77; positive predictive value, 0.24; negative predictive value, 0.96). CONCLUSION: Mastora score was a significant predictor of cor pulmonale and short-term outcome and may therefore allow therapy and risk stratification in patients with acute PE.

Acute Disease↗

Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria.

The purpose of this study was to compare relative values of manual unidimensional measurements (MD) and automated volumetry (AV) for longitudinal treatment response assessment in patients with pulmonary metastases. Fifty consecutive patients with pulmonary metastases and repeat chest multidetector-row CT (median interval=2 months) were independently assessed by two radiologists for treatment response using Response Evaluation Criteria In Solid Tumours (RECIST). Statistics included relative measurement errors (RME), intra-/interobserver correlations, limits of agreement (95% LoA), and kappa. A total of 202 metastases (median volume=182.22 mm(3); range=3.16-5,195.13 mm(3)) were evaluated. RMEs were significantly higher for MD than for AV (intraobserver RME=2.34-3.73% and 0.15-0.22% for MD and AV respectively; P<0.05. Interobserver RME=3.53-3.76% and 0.22-0.29% for MD and AV respectively; P<0.05). Overall correlation was significantly better for AV than for MD (P<0.05). Intraobserver 95% LoAs were -1.85 to 1.75 mm for MD and -11.28 to 9.84 mm(3) for AV. The interobserver 95% LoA were -1.46 to 1.92 mm for MD and -11.17 to 9.33 mm(3) for AV. There was total intra-/interobserver agreement on response using AV (kappa=1). MD intra- and interobserver agreements were 0.73-0.84 and 0.77-0.80 respectively. Of the 200 MD response ratings, 28 (14/50 patients) were discordant. Agreement using MD dropped significantly from total remission to progressive disease (P<0.05). We therefore conclude that AV allows for better reproducibility of response evaluation in pulmonary metastases and should be preferred to MD in these patients.

Adult↗

Imaging of macrophage-related lung diseases.

Macrophage-related pulmonary diseases are a heterogeneous group of disorders characterized by macrophage accumulation, activation or dysfunction. These conditions include smoking-related interstitial lung diseases, metabolic disorders such as Niemann-Pick or Gaucher disease, and rare primary lung tumors. High-resolution computed tomography abnormalities include pulmonary ground-glass opacification secondary to infiltration by macrophages, centrilobular nodules or interlobular septal thickening reflecting peribronchiolar or septal macrophage accumulation, respectively, emphysema caused by macrophage dysfunction, and honeycombing following macrophage-related lung matrix remodeling.

Capillaries↗

Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings.

The purpose of this study was to evaluate the performance of a computer-assisted diagnostic (CAD) tool using various reconstruction slice thicknesses (RST). Image data of 20 patients undergoing multislice CT for pulmonary metastasis were reconstructed at 4.0, 2.0 and 0.75 mm RST and assessed by two blinded radiologists (R1 and R2) and CAD. Data were compared against an independent reference standard. Nodule subgroups (diameter >10, 4-10, <4 mm) were assessed separately. Statistical methods were the ROC analysis and Mann-Whitney U test. CAD was outperformed by readers at 4.0 mm (Az = 0.18, 0.62 and 0.69 for CAD, R1 and R2, respectively; P<0.05), comparable at 2.0 mm (Az = 0.57, 0.70 and 0.69 for CAD, R1 and R2, respectively), and superior using 0.75 mm RST (Az = 0.80, 0.70 and 0.70 and sensitivity = 0.74, 0.53 and 0.53 for CAD, R1 and R2, respectively; P<0.05). Reader performances were significantly enhanced by CAD (Az = 0.93 and 0.95 for R1 + CAD and R2 + CAD, respectively, P<0.05). The CAD advantage was best for nodules <10 mm (detection rates = 93.3, 89.9, 47.9 and 47.9% for R1 + CAD, R2 + CAD, R1 and R2, respectively). CAD using 0.75 mm RST outperformed radiologists in nodules below 10 mm in diameter and should be used to replace a second radiologist. CAD is not recommended for 4.0 mm RST.

Adult↗

Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists.

To evaluate the performance of experienced versus inexperienced radiologists in comparison and in consensus with an interactive computer-aided detection (CAD) system for detection of pulmonary nodules. Eighteen consecutive patients (mean age: 62.2 years; range 29-83 years) prospectively underwent routine 16-row multislice computed tomography (MSCT). Four blinded radiologists (experienced: readers 1, 2; inexperienced: readers 3, 4) assessed image data against CAD for pulmonary nodules. Thereafter, consensus readings of readers 1+3, reader 1+CAD and reader 3+CAD were performed. Data were compared against an independent gold standard. Statistical tests used to calculate interobserver agreement, reader performance and nodule size were Kappa, ROC and Mann-Whitney U. CAD and experienced readers outperformed inexperienced readers (Az=0.72, 0.71, 0.73, 0.49 and 0.50 for CAD, readers 1-4, respectively; P<0.05). Performance of reader 1+CAD was superior to single reader and reader 1+3 performances (Az=0.93, 0.72 for reader 1+CAD and reader 1+3 consensus, respectively, P<0.05). Reader 3+CAD did not perform superiorly to experienced readers or CAD (Az=0.79 for reader 3+CAD; P>0.05). Consensus of reader 1+CAD significantly outperformed all other readings, demonstrating a benefit in using CAD as an inexperienced reader replacement. It is questionable whether inexperienced readers can be regarded as adequate for interpretation of pulmonary nodules in consensus with CAD, replacing an experienced radiologist.

Adult↗

Soft copy versus hard copy reading in digital mammography.

The objective of this study was to compare soft copy reading at a mammography work station with hard copy reading of full-field digital mammographic images. Mammograms of 60 patients ( n = 29 malignant, n = 31 benign) performed with full-field digital mammography (Senographe 2000D, GE, Buc, France) were evaluated. Reading was performed based on hard copy prints (Scopix, Agfa, Leverkusen, Germany) and on 2 k x 2.5 k high-resolution monitors (Sun Ultra 60, Sun Microsystems, Palo Alto, California, USA). Four readers with different levels of experience in mammography categorized the mammograms according to the BI-RADS classification. The comparative study was performed by four readers, and at least 2 months elapsed between the reading sessions. Postprocessing, of course, was available only at the work station (windowing and leveling, zooming, inversion). Sensitivity, specificity, and positive predictive value were evaluated. Diagnostic accuracy of the evaluation was determined. Sensitivity for malignant lesions in hard copy versus soft copy reading was 97% vs 90%, 97% vs 97%, 93% vs 97%, and 76% vs 76% for the four readers, respectively. Specificity was 52% vs 68%, 58% vs 74%, 65% vs 48%, and 61% vs 68%. Accuracy for the classification of malignant lesions according to the BI-RADS categories showed no difference between hard copy and soft copy reading. Soft copy reading is possible with the available system and enables radiologists to use the advantages of a digital system.

Breast Neoplasms↗

Flat panel detector-based volumetric CT: prototype evaluation with volumetry of small artificial nodules in a pulmonary phantom.

PURPOSE: To evaluate amorphous silicone-based flat panel detector volumetric CT (VCT) in volumetric assessment of small nodules in a pulmonary phantom, and to perform comparative experiments with 4-row multislice CT (MSCT). MATERIALS AND METHODS: Seventy synthetic nodules (volume range (VR): 0.99-185.77 mm; estimated diameter range (ED): 1.4-7.8 mm) were scanned in spherical shape and after iso-volumetric deformation with VCT and MSCT using 0.63 mm (MSCT I) and 1.25 mm (MSCT II) collimations. Measured volumes and percent measurement errors (PME) were compared between the 3 CT modes before and after nodule deformation. For each measurement pair before and after deformation, the post-deformation relative volumetric inaccuracy (RIA) was determined. Volume, PME, and RIA differences were tested using Wilcoxon and Friedman methods. RESULTS: The volumes of the smallest nodules (VR = 0.99-2.83 mm, ED = 1.4-1.9 mm) were computable only from VCT scans. In VCT, measured volumes and PMEs before and after deformation differed significantly less compared with MSCT (VCT: P = 0.06 and 0.56, respectively; MSCT I: P = 0.0012 and 0.006, respectively; and MSCT II: P < 0.0001 for measured volumes and PMEs). In VCT PMEs of 5.51-32.21 mm nodules (ED = 2.4-4.1 mm) before and after deformation were significantly below MSCT (VCT averages = 1.43-1.91% and 1.98-3.48%, for spherical and deformed nodules, respectively; MSCT I averages = 9.97-26.1% and 12.16-38.10%, respectively; MSCT II averages = 17.79-46.18 and 18.14-54.66%, respectively, P < 0.0001) and RIAs in VCT were significantly below MSCT (VCT: 0.50-2.62%, MSCT I: 3.35-15.97%, and MSCT II: 4.29-18.46%; P = 0.0001-0.0039). CONCLUSION: VCT volumetry is highly accurate in volumetry of smallest nodules with estimated diameters of 1.4-4.1 mm.

Humans↗

Detection of dysplastic intestinal adenomas using enzyme-sensing molecular beacons in mice.

BACKGROUND & AIMS: Proteases play key roles in the pathogenesis of tumor growth and invasion. This study assesses the expression of cathepsin B in dysplastic adenomatous polyps. METHODS: Aged Apc(Min/+) mice served as an experimental model for familial adenomatous polyposis. The 4 experimental groups consisted of (a) animals injected with a novel activatable, cathepsin B sensing near infrared fluorescence (NIRF) imaging probe; (b) animals injected with a nonspecific NIRF; (c) uninjected control animals; and (d) non-APC(Min/+) mice injected with the cathepsin B probe. Lesions were analyzed by immunohistochemistry, Western blotting, reverse transcription-polymerase chain reaction, and optical imaging. RESULTS: Cathepsin B was consistently overexpressed in adenomatous polyps. When mice were injected intravenously with the cathepsin reporter probe, intestinal adenomas became highly fluorescent indicative of high cathepsin B enzyme activity. Even microscopic adenomas were readily detectable by fluorescence, but not light, imaging. The smallest lesion detectable measured 50 microm in diameter. Adenomas in the indocyanine green and/or noninjected group were only barely detectable above the background. CONCLUSIONS: The current experimental study shows that cathepsin B is up-regulated in a mouse model of adenomatous polyposis. Cathepsin B activity can be used as a biomarker to readily identify such lesions, particularly when contrasted against normal adjacent mucosa. This detection technology can be adapted to endoscopy or tomographic optical imaging methods for screening of suspicious lesions and potentially for molecular profiling in vivo.

Adenomatous Polyps↗

The challenge of the solitary pulmonary nodule: diagnostic assessment with multislice spiral CT.

The advent of fast multiscale computed tomography (MSCT) technology has sparked new interest in the noninvasive assessment of the solitary pulmonary nodule (SPN). Fast scanning within a single breath-hold period, simultaneous acquisition of multiple thin slices with subsequent morphologic characterization of the nodule, determination of perfusion patterns as well as growth rates has led to unprecedented improvements in this emerging field. This article reviews the capabilities of MSCT in the diagnostic assessment of the SPN.

Biopsy, Needle↗