PubMed Health⌕ Search

Biomedical subjects

Kathinka Peels

Publications and source records attributed to Kathinka Peels.

3 recordsLinked to original sources

Quantification in echocardiography.

Until recently, more than 2200 Swan Ganz catheters were used annually in the operating rooms (OR) and intensive care unit (ICU) of the Catharina Hospital in Eindhoven, The Netherlands. After cardiologists who were specialists in echocardiography (ECHO) trained anesthesiologists in ECHO, the need for these catheters in cardiac and noncardiac surgery was reduced. Initially intended as a local teaching project, an ECHO teaching compact disk (CD) was produced during the training and distributed later worldwide, thanks to a positive review in a major anesthesiology publication. By reducing the number of Swan Ganz catheters, the hospital could finance and acquire two echocardiography machines for the OR and ICU. The availability of these machines resulted in a further reduction of the number of Swan Ganz catheters. However, the need for quantification (eg, measurements of cardiac output) remained. During the creation of the ECHO teaching CD, the idea was born to apply indicator-dilution principles on injected echo contrast. This study was performed in cooperation with the Signal Processing Department of the Eindhoven University of Technology. Advanced signal processing and modelling were used to develop algorithms to enable quantification of intrapulmonary blood volume, ejection-fraction, and flow from the transesophageal echocardiography approach. These quantitative measurements, which can be performed on an outpatient basis, may become a real asset in cardiology, anesthesiology, and intensive care.

Algorithms↗

Percutaneous coronary intervention or bypass surgery in multivessel disease? A tailored approach based on coronary pressure measurement.

The optimal revascularization strategy, percutaneous coronary intervention (PCI) or coronary artery bypass graft surgery (CABG), for patients with multivessel coronary artery disease (MVD) remains controversial. The aim of the present study was to compare the long-term outcomes after selective PCI of only hemodynamically significant lesions (fractional flow reserve, or FFR < 0.75) to CABG of all stenoses in patients with MVD. In 150 patients with MVD referred for CABG, FFR was determined in 381 coronary arteries considered for bypass grafting. If the FFR was less than 0.75 in three vessels or in two vessels including the proximal left anterior descending (LAD) artery, CABG was performed (CABG group). If only one or two vessels were physiologically significant (not including the proximal LAD), PCI of those lesions was performed (PCI group). Of the 150 patients, 87 fulfilled the criteria for CABG and 63 for PCI. There were no significant differences in the angiographic or other baseline characteristics between the two groups. At 2-year follow-up, no differences were seen in adverse events, including repeat revascularization (event-free survival 74% in the CABG group and 72% in the PCI group). A similar number of patients were free from angina (84% in the CABG group and 82% in the PCI group). Importantly, the results in both groups were as good as the surgical groups in previous studies comparing PCI and CABG in MVD. In patients with multivessel disease, PCI in those with one or two hemodynamically significant lesions as identified by an FFR < 0.75 yields a similar favorable outcome as CABG in those with three or more culprit lesions despite a similar angiographic extent of disease.

Adult↗

Transesophageal echocardiographic evaluation of tricuspid valve regurgitation during pacemaker and implantable cardioverter defibrillator lead extraction.

Chronically implanted ventricular pacing and defibrillator (ICD) leads can adhere to the tricuspid valve. This study examined the effect of lead extraction, and laser sheath extraction in particular, on tricuspid valve regurgitation. Lead extraction was first tried with traction using limited force followed by a laser sheath if not successful. Tricuspid valve regurgitation before and after extraction was evaluated with transesophageal echocardiography and graded from 0 (none) to 4 (severe). A change in regurgitation was considered clinically relevant if it increased with two grades or more and resulted in at least grade 3 regurgitation. Fifty ventricular leads were extracted in 43 consecutive patients, including 14 ICD leads. In 20 patients (group I) leads were removed without a (laser) sheath crossing the tricuspid valve, in 23 patients (group II) leads were extracted with lasing across the valve. The mean time from implant was 43 +/- 43 months and 99 +/- 78 months, respectively, (P = 0.007). Tricuspid regurgitation increased in five (12%) patients. In group I only in one patient the laser failed proximal of the valve and forceful traction was subsequently used, and in group II this occurred in four (17%) patients. This difference did not reach statistical significance even excluding the patient from group I (P = 0.111). The increase of tricuspid regurgitation cautions against indiscriminate extraction of superfluous leads. There is a trend that when tools like a laser sheath are necessary the chance of tricuspid valve damage increases.

Defibrillators, Implantable↗