PubMed Health⌕ Search

Biomedical subjects

Kathryn Dawson

Publications and source records attributed to Kathryn Dawson.

4 recordsLinked to original sources

Simultaneous integrated boost intensity-modulated radiotherapy for locally advanced head-and-neck squamous cell carcinomas: II--clinical results.

PURPOSE: To perform a Phase I radiation dose-escalation trial to determine the maximal tolerable dose (MTD) deliverable to the gross tumor volume (GTV) using an accelerated fractionation with simultaneous integrated boost intensity-modulated radiotherapy regimen with parotid gland sparing as the sole therapy in the treatment of locally advanced head-and-neck squamous cell carcinoma. The primary objective was the definition of the MTD using established criteria of quantifying acute dose-limiting toxicity (DLT). Secondary objectives included analysis of failure patterns, tumor control rates, and toxicity. METHODS AND MATERIALS: Between July 1999 and June 2002, eligible patients with bulky Stage II to Stage IVB head-and-neck squamous cell carcinoma, excluding laryngeal primaries, were enrolled. Intensity-modulated radiotherapy was delivered with 6-MV photons using a "sliding-window" technique. Enrollment of 6 patients for each dose level was planned; if DLTs were seen in >2 of 6 patients, the previous dose was to be expanded by an additional 6 patients to confirm that dose level as the MTD. All schedules administered a total of 30 fractions, but with escalating doses per fraction (2.27, 2.36, and 2.46 Gy) to achieve a total dose to the GTV of 68.1, 70.8, and 73.8 Gy, respectively. The remaining target tissues were constrained to receive the same dose in all patients regardless of the GTV dose level. The clinical target volume, defined as tissue within 1 cm around the GTV (at high risk of subclinical disease), received 60 Gy in 30 fractions of 2.0 Gy. The electively irradiated target volume, defined as the clinically uninvolved lymph node-bearing tissues, received 54 Gy in 30 fractions of 1.8 Gy. The parotid glands were spared to the degree possible without compromising target coverage. Acute toxicity was scored weekly using National Cancer Institute Common Toxicity Criteria. DLT was defined as any Grade 4 acute toxicity or any acute toxicity requiring either a dose reduction or a treatment break of >5 treatment days. RESULTS: Of 18 men and 2 women (average age, 57 years; range, 37-80 years), 17 presented with oropharyngeal primary tumors, and 1 each with squamous cell carcinoma of the oral cavity, nasopharynx, and hypopharynx. None of the 6 patients at dose level 1, and 2 of the 6 patients initially enrolled at dose level 2, developed DLT. Both patients treated at dose level 3 required a 3-day treatment break and dose reduction after rapid development of Grade 3 toxicity (by Day 15). Six additional confirmatory patients subsequently enrolled at dose level 2 completed treatment without DLT. At least 50% of the total parotid gland volume received <30 Gy in 14 patients (average, 54% of volume), with an average mean dose of 32 Gy. In contrast, >/=50% of the distal parotid gland volume received <25 Gy in 15 patients (average, 63% of volume), with an average mean dose of 24 Gy. With a median follow-up of 20 months from the date of enrollment and 28 months for surviving patients, the actuarial 2-year local control (primary site), regional control (nodal sites), and distant control rate was 76.3%, 66.7%, and 71.8%, respectively. CONCLUSION: Dose level 2, 70.8 Gy in 30 fractions of 2.36 Gy, was defined as the MTD deliverable to the GTV using this accelerated fractionation with simultaneous integrated boost intensity-modulated radiotherapy regimen with parotid gland sparing as the sole treatment for locally advanced head-and-neck squamous cell carcinoma. Adequate parotid sparing was achievable in most cases. Early toxicity, tumor control, and survival rates compared favorably with the outcomes after other accelerated regimens.

Adult↗

Temperatures within the lumbar disc and endplates during intradiscal electrothermal therapy: formulation of a predictive temperature map in relation to distance from the catheter.

STUDY DESIGN: Temperatures were measured in human cadaveric lumbar discs during intradiscal electrothermal therapy. OBJECTIVES: To determine if sufficient temperatures for collagen denaturation and nociceptive ablation can be achieved at clinically significant distances from the intradiscal electrothermal therapy heating catheter. SUMMARY OF BACKGROUND DATA: Previous cadaveric studies have contested the ability of the intradiscal electrothermal therapy catheter to produce sufficient temperatures to denature collagen and cause neural ablation within the posterior anulus of the disc. However, these experiments used clinically unrepresentative device placements along the anterolateral anulus. METHODS: Intradiscal electrothermal therapy was performed in 14 human cadaveric discs. Devices were inserted using a standard posterolateral approach to orient the heating catheter along the posterior anulus. Temperature recordings were collected using multiple sensors placed along the posterior anulus, anterior anulus, and endplates. RESULTS: Temperatures greater than 60 C and 65 C were achieved in 14 and 5 specimens, respectively, at distances up to 2 mm from the catheter. Between 2 and 4 mm, more than 60 C was achieved in all specimens. More than 45 C was achieved in all specimens at distances of 9 to 14 mm from the device. CONCLUSIONS: Temperatures sufficient for collagen denaturation and nociceptive ablation were detected at distances greater than previously documented. These data suggest that intradiscal electrothermal therapy's proposed heat-dependent mechanisms of action are achievable in most discs. Among other factors, interspecimen variability of maximum temperatures may help explain the somewhat inconsistent clinical results following intradiscal electrothermal therapy.

Adult↗

Monte Carlo source model for photon beam radiotherapy: photon source characteristics.

A major barrier to widespread clinical implementation of Monte Carlo dose calculation is the difficulty in characterizing the radiation source within a generalized source model. This work aims to develop a generalized three-component source model (target, primary collimator, flattening filter) for 6- and 18-MV photon beams that match full phase-space data (PSD). Subsource by subsource comparison of dose distributions, using either source PSD or the source model as input, allows accurate source characterization and has the potential to ease the commissioning procedure, since it is possible to obtain information about which subsource needs to be tuned. This source model is unique in that, compared to previous source models, it retains additional correlations among PS variables, which improves accuracy at nonstandard source-to-surface distances (SSDs). In our study, three-dimensional (3D) dose calculations were performed for SSDs ranging from 50 to 200 cm and for field sizes from 1 x 1 to 30 x 30 cm2 as well as a 10 x 10 cm2 field 5 cm off axis in each direction. The 3D dose distributions, using either full PSD or the source model as input, were compared in terms of dose-difference and distance-to-agreement. With this model, over 99% of the voxels agreed within +/-1% or 1 mm for the target, within 2% or 2 mm for the primary collimator, and within +/-2.5% or 2 mm for the flattening filter in all cases studied. For the dose distributions, 99% of the dose voxels agreed within 1% or 1 mm when the combined source model-including a charged particle source and the full PSD as input-was used. The accurate and general characterization of each photon source and knowledge of the subsource dose distributions should facilitate source model commissioning procedures by allowing scaling the histogram distributions representing the subsources to be tuned.

Algorithms↗

A randomized, placebo-controlled trial of intradiscal electrothermal therapy for the treatment of discogenic low back pain.

BACKGROUND: Intradiscal electrothermal therapy (IDET) is a treatment for discogenic low back pain the efficacy of which has not been rigorously tested. PURPOSE: To compare the efficacy of IDET with that of a placebo treatment. STUDY DESIGN/SETTING: Randomized, placebo-controlled, prospective trial. PATIENT SAMPLE: Patients were recruited by referral and the media. No inducements were provided to any patient in order to have them participate. Of 1,360 individuals who were prepared to submit to randomization, 260 were found potentially eligible after clinical examination and 64 became eligible after discography. All had discogenic low back pain lasting longer than 6 months, with no comorbidity. Thirty-seven were allocated to IDET and 27 to sham treatment. Both groups were satisfactorily matched for demographic and clinical features. METHODS: IDET was performed using a standard protocol, in which the posterior annulus of the painful disc was heated to 90 C. Sham therapy consisted of introducing a needle onto the disc and exposing the patient to the same visual and auditory environment as for a real procedure. Thirty-two (85%) of the patients randomized to the IDET group and 24 (89%) of those assigned to the sham group complied fully with the protocol of the study, and complete follow-up data are available for all of these patients. OUTCOME MEASURES: The principal outcome measures were pain and disability, assessed using a visual analog scale for pain, the Short Form (SF)-36, and the Oswestry disability scale. RESULTS: Patients in both groups exhibited improvements, but mean improvements in pain, disability and depression were significantly greater in the group treated with IDET. More patients deteriorated when subjected to sham treatment, whereas a greater proportion showed improvements in pain when treated with IDET. The number needed to treat, to achieve 75% relief of pain, was five. Whereas approximately 40% of the patients achieved greater than 50% relief of their pain, approximately 50% of the patients experienced no appreciable benefit. CONCLUSIONS: Nonspecific factors associated with the procedure account for a proportion of the apparent efficacy of IDET, but its efficacy cannot be attributed wholly to a placebo effect. The results of this trial cannot be generalized to patients who do not fit the strict inclusion criteria of this study, but IDET appears to provide worthwhile relief in a small proportion of strictly defined patients undergoing this treatment for intractable low back pain.

Adult↗