PubMed Health⌕ Search

Biomedical subjects

Katrien Devreese

Publications and source records attributed to Katrien Devreese.

3 recordsLinked to original sources

Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin cofactor activity assay for the diagnosis of von Willebrand disease.

von Willebrand disease (VWD) is caused by quantitative and/or qualitative defects of von Willebrand factor (VWF). The HemosIL von Willebrand Factor Activity assay, a new automated immunological test to measure VWF activity, was implemented on STAC and compared with the von Willebrand ristocetin cofactor activity (VWF:RCo) aggregation method. Imprecision and dilution studies were also performed. Within-run imprecision was 17.2% and between-run imprecision was 8.3% (coefficients of variation). Dilution studies showed a linearity between 12.5 and 100%. Passing and Bablok regression comparing the HemosIL von Willebrand Factor Activity assay and the aggregation method yielded a slope of 1.25 (95% confidence interval: 1.11-1.38) and intercept of -1.40 (95% confidence interval: -8.07 to 0.00). The correlation coefficient was 0.84 (95% confidence interval: 0.78-0.89). With a cut-off value of 50% for VWF activity, the assay has a sensitivity of 94.1% and a specificity of 92.8%, compared with the VWF:RCo aggregation assay with a cut-off value of 60% producing a sensitivity of 100.0% (specificity 87.6%). With a cut-off value of 60%, the HemosIL von Willebrand Factor Activity assay on STAC is a reliable assay for VWD. VWF:RCo or other functional testing is still required to confirm the diagnosis and for further classification of VWD.

Female↗

Factor V inhibitor: case report.

Acquired inhibitors to coagulation factors are rare, certainly those directed against factor V. A total of around 150 cases have so far been reported, of which the greater part was due to bovine thrombin exposure. We report the case of a patient who developed a factor V inhibitor during a postoperative period. This report describes possible aetiologies, varying clinical conditions and treatment possibilities as described in the literature. Furthermore, this case report is an example of the often unpredictable disease progression in a patient with existence of a factor V inhibitor.

Aged↗

Reference intervals for a complete blood count determined on different automated haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120.

We processed 317 samples from healthy adult volunteers for a complete blood count, including leukocyte differentials and reticulocyte parameters, through five new-generation haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120. From these data non-parametric 2.5-97.5 percentile reference intervals were calculated for all parameters on all analysers. Some differences were found compared with previously reported reference intervals. Reference intervals for platelet parameters and reticulocytes agreed with these usually accepted. For red blood cell parameters, including haemoglobin and haematocrit, and white blood cell count, including absolute white blood cell differentials, our calculated reference intervals were in agreement with less frequently cited earlier reports, but were lower compared to the usually accepted reference intervals.

Adult↗