PubMed Health⌕ Search

Biomedical subjects

Katrien François

Publications and source records attributed to Katrien François.

12 recordsLinked to original sources

Stentless and stented aortic valve replacement in elderly patients: Factors affecting midterm clinical and hemodynamical outcome.

OBJECTIVE: To report on the midterm results of aortic valve replacement (AVR) with stented and stentless bioprosthesis in an elderly population by analyzing the factors affecting survival and hemodynamical performance. METHODS: In a retrospective study, 145 patients with a Toronto stentless prosthesis are compared with 110 patients with a stented Carpentier-Edwards valve. The 5- to 10-year clinical outcome, transprosthetic gradients, and early and late left ventricular mass (LVM) regression are analyzed in view of specific prosthesis- and patient-related factors. RESULTS: Actuarial survival at 5 years is 82% after stentless AVR versus 68% after stented AVR (p < 0.001) in elderly patients. However, there was no difference in survival at 8 years, being 55.9% and 59.5%, respectively. Univariate analysis revealed that advanced age at the time of operation, NYHA class IV, use of a stented xenograft, presence of patient-prosthesis mismatch (PPM) (IEOA < or = 0.85 cm2/m2), and severe preoperative left ventricular (LV) hypertrophy (LVMI > 180 g/m2) affected survival adversely. But multivariate analysis determined only age, NYHA class IV and excessive LV hypertrophy as independent predictors of late mortality. Stented and stentless xenografts were equally effective in terms of transprosthetic gradients and LVMI regression. The use of a stentless valve significantly reduced the occurrence of PPM (18% vs 41%, p < 0.01). Early LVMI regression at 1 year was optimized by the avoidance of PPM, indicated by a higher absolute (43.7+/-28.3 g/m2 vs 58.6+/-33.8 g/m2, p = 0.003) and relative (25.0+/-12.7% vs 31.4+/-14.9%, p=0.004) mass regression. However, late LV remodeling was predominantly affected by systemic hypertension and severe preoperative LV hypertrophy, resulting in the incomplete LVMI resolution in 61.3% and 66.7% of these patients, respectively. CONCLUSION: In elderly patients, aortic valve replacement appears to be equally effective with a stentless or stented bioprosthesis. Midterm clinical outcome is mainly determined by patient-related factors such as age, advanced NYHA class, and severity of preoperative LV hypertrophy. Regarding post-AVR left ventricular remodeling, patient-prosthesis mismatch influences the early phase, whereas arterial hypertension affects the late regression more. However, the left ventricular remodeling is continuously compromised by the preoperative presence of excessive hypertrophy, despite the efficacy of the aortic valve replacement.

Aged↗

Primary impairment of left ventricular function in Marfan syndrome.

BACKGROUND: Cardiovascular involvement in Marfan syndrome is mainly characterized by progressive dilatation of the proximal aorta. Whether left ventricular dysfunction is present in these patients is not clear at present. OBJECTIVES: Assess left ventricular function in patients with Marfan syndrome, free of significant valvular heart disease, using a combination of MRI and Tissue Doppler imaging (TDI). METHODS AND RESULTS: A total of 26 Marfan patients (mean age=32.0+/-10.9, 12 men) without significant valvular heart disease, and 26 age- and sex-matched controls were studied. Left ventricular volumes and ejection fraction were measured with magnetic resonance imaging. Systolic and diastolic function parameters were assessed using conventional echocardiography and TDI. When compared to controls, Marfan patients showed impairment of left ventricular contractile function as expressed by a reduced ejection fraction (53.5+/-9.0% vs. 59.6+/-6.7%, p=0.009), an increased end-systolic volume (36.0+/-9.5 vs. 29.5+/-6.7 ml/m(2), p=0.007), and reduced peak systolic velocities at the basal septal and lateral myocardial wall (5.2+/-1.4 vs. 6.4+/-1.3 cm/s, p=0.003 and 6.0+/-2.2 vs. 7.5+/-2.3 cm/s, p=0.03, respectively). Diastolic function was impaired with an increased deceleration time of the E wave (171+/-41 ms vs. 141+/-36 ms, p=0.006). Peak early diastolic velocity at the mitral valve annulus was significantly lower (9.6+/-2.4 cm/s vs. 11.9+/-3.3 cm/s, p=0.006). CONCLUSION: These data provide evidence for mild, but significant impairment of left ventricular systolic and diastolic function in Marfan patients, not related to valvular heart disease.

Adult↗

Stentless vs. stented aortic valve replacement: left ventricular mass regression.

The aim of this retrospective study was to evaluate the time-related regression of left ventricular hypertrophy after stentless vs. stented aortic valve replacement. From January 1992 to December 2002, 145 patients had a Toronto stentless porcine valve and 106 had a stented Carpentier-Edwards aortic valve replacement. Over a 10-year follow-up, survival was superior in the Toronto group vs. the Carpentier-Edwards group (84% vs. 74% at 4 years; 78% vs. 68% at 6 years; p < 0.001). A significant and constant reduction of peak and mean transvalvular gradients after valve replacement resulted in substantial regression of left ventricular mass index in both groups, which did not reach statistical significance. However, this phenomenon stopped at 3 years, and left ventricular mass index increased slowly after 5 years. Stentless and stented bioprostheses both showed good early and late clinical and hemodynamic outcomes, with the advantage of better midterm survival for stentless xenografts.

Adult↗

Aortic valve replacement with Toronto SPV in elderly patients: 10-year results.

A retrospective assessment of clinical and echocardiographic variables was performed in 145 patients who received a Toronto SPV aortic valve replacement. The majority (90%) of these elderly patients (mean age, 75.5 +/- 7.4 years) were preoperatively in New York Heart Association class III-IV. Operative mortality was 4.8%. Follow-up was complete up to 10 years and revealed few valve-related complications: thromboembolism (7), bleeding (4), and prosthesis dysfunction necessitating reoperation (3). Late mortality was cardiac-related in 11.7% and noncardiac-related in 17.2%. Actuarial survival was 83% at 5 years and 63% at 8 years. Echocardiography showed low transvalvular gradients (peak, 17.5 +/- 7.5 mm Hg; mean, 9.2 +/- 4.2 mm Hg) resulting in a significant reduction in left ventricular mass index during the first 3 years. Independent of the transprosthetic gradient, left ventricular mass index tended to increase again beyond the 5th year, which correlated positively with the presence of arterial hypertension in this older population. The Toronto SPV bioprosthesis offers an aortic valve substitute with excellent long-term hemodynamics, resulting in significant early left ventricular mass regression. Considering the limitations of this selected elderly population, the clinical outcome and survival up to 10 years are encouraging, with few observed valve-related events.

Aged↗

Outcome analysis of major cardiac operations in low weight neonates.

BACKGROUND: From June 1995 to January 2003, 49 consecutive neonates of less than 2,500 g underwent early surgery for congenital heart disease. A retrospective analysis was performed to evaluate the early to medium term outcome. METHODS: Major cardiac surgery for congenital heart defects included a complete correction in 31 patients (group I) and a palliative procedure in 18 patients (group II). Mean age at operation was 15.2 days (1 day-90 days) and mean weight was 2,190 g (1,300 g-2,500 g). Twenty-four children (49%) were born prematurely. All neonates were critically ill and 47% were already ventilated preoperatively. Heart defects included mainly ventricular septal defect (10), tetralogy of Fallot complexes (8), aortic coarctation (8), transposition complexes (7), single ventricle anomalies (4), pulmonary atresia with intact septum (4), interrupted aortic arch (3), totally anomalous pulmonary venous return (3), and common atrioventricular septal defect (2). RESULTS: Overall surgical mortality was 18%: 4 neonates died after definitive repair and 5 after palliation; representing, respectively, 13% and 28% of each group. Postoperative morbidity occurred in half of the patients (53%). Age, weight, prematurity, type of first surgical procedure, and use of cardiopulmonary bypass did not influence the early outcome. After a mean follow-up of 2.82 years (2 months to 6 years), survival was 87% in the correction group and 54% in the palliation group. All children were in NYHA class I-II. Freedom from reintervention at 18 months was 68% after correction versus 8% after palliation. CONCLUSIONS: Cardiac surgery for congenital malformations in critically ill, low weight neonates can be achieved with acceptable mortality, at the cost of an increased morbidity. Early outcome seems independent of age, weight, prematurity, use of extracorporeal perfusion, and type of first intervention. Moreover, primary correction appears to result in an early survival benefit, remaining constant over time.

Birth Weight↗

Successful management of a large pulmonary cement embolus after percutaneous vertebroplasty: a case report.

Percutaneous vertebroplasty is increasingly used for the treatment of vertebral compression fractures. Local leakage of polymethylmethacrylate cement into the perivertebral space is a common complication, but important systemic effects have rarely been reported. The authors describe the case of a 52-year-old patient with central pulmonary embolism after percutaneous vertebroplasty of the eleventh thoracic vertebral body. The large cement embolus was removed from the right pulmonary artery with a hybrid technique combining an interventional catheter procedure with an open heart operation. The patient made an uneventful recovery. The authors review how appropriate arthroplasty techniques might minimize the risk of this dreadful complication.

Acenocoumarol↗

Lower anticoagulation for mechanical heart valves: experience with the ATS bileaflet valve.

BACKGROUND: The design of the bileaflet ATS (ATS Medical Inc., Minneapolis, USA) mechanical valve incorporates an open pivot at the hinge mechanism. Total washout of the blood at the pivot area was observed using 3-D computational fluid dynamics modelling. This phenomenon could make the valve less vulnerable to clot formation in patients without major thromboembolic risk factors. METHODS: From January 1993 to June 1999, 286 consecutive patients had the ATS valve inserted in the aortic position. Patients were divided into two groups. Group 1 comprised all patients in regular sinus rhythm with good left ventricular function (144 patients). Group 2 included patients in non-sinus rhythm and/or with large hypocontractile left ventricles (142 patients). The anticoagulation regime in group 1 was used to obtain an international normalised ratio (INR) between 1.5 and 2.5. This contrasts with our regular aim to maintain the INR strictly between 2.5 and 3.5 for all mechanical valves, as achieved in group 2. RESULTS: The follow-up period (99% completeness) ranged from 18 to 84 months. Survival (Kaplan-Meier) was 97 and 98% and 92 and 81% at 1 and 5 years in group 1 and group 2, respectively (P = 0.12). Log rank analysis failed to detect a statistical difference in thromboembolism or bleeding between both groups (P > 0.05). However, trends were in favour of group 1. Univariate analysis selected poor ventricular function and an 'erratic' INR value (P = 0.002) as risk factors for death. The sole independent risk factor for bleeding was the use of aspirin (P = 0.025). CONCLUSIONS: The excellent group 1 data and outcome encouraged us to continue our low intensive anticoagulation regime and perhaps should be regarded as a new concept for treatment of selected mechanical valve patients.

Journal Article↗

Left ventricular outflow obstruction in rhabdomyoma of infancy: meta-analysis of the literature.

Primary heart tumors are exceptional in infants and children. Most common is the rhabdomyoma, often associated with tuberous sclerosis (Bourneville's disease). This tumor is generally believed to have no hemodynamic effects in the majority of cases. Recently, severe obstruction of the left ventricular outflow tract by a solitary tumor was diagnosed during pregnancy and emergency surgery was needed soon after birth.

Female↗

Lower-intensity anticoagulation for mechanical heart valves: a new concept with the ATS bileaflet aortic valve.

BACKGROUND AND AIM OF THE STUDY: The design of the bileaflet ATS mechanical valve incorporates an open pivot at the hinge mechanism. Total washout of blood at the pivot area seen using three-dimensional computational fluid dynamics modeling may make the valve less vulnerable for clot formation in patients without major thromboembolic risk factors. METHODS: Between January 1993 and June 1999, the ATS valve was implanted in the aortic position in 286 consecutive patients. Patients were allocated prospectively to two groups: group 1 comprised patients in regular sinus rhythm with good left ventricular (LV) function (n = 144); group 2 included patients in non-sinus rhythm and/or with large hypocontractile left ventricles (n = 142). The anticoagulation regime in group 1 was to achieve an INR of 1.5-2.5, rather than to maintain INR strictly at 2.5-3.5 for mechanical valves (as in group 2). RESULTS: Follow up was 99% complete and ranged from 50 to 120 months. Survival (Kaplan-Meier) was respectively 95% and 90% and 90% and 83% at 2 and 5 years in favor of group 1 (p = 0.0055). Multivariate analysis selected advanced age, poor LV function and 'erratic' INR as risk factors for death. Log rank analysis failed to detect any statistical difference in thromboembolism. Bleeding occurred more frequently in group 2 (p = 0.018); independent risk factors for bleeding were the presence of aspirin (p = 0.0164) and advanced age (p = 0.02). CONCLUSION: The excellent group 1 data and outcome encouraged continuation of the low-intensity anticoagulation regime, and should be regarded as a new concept for the treatment of mechanical valve patients.

Aged↗

Use of an event recorder in the decision for pacemaker implantation in a child with syncope.

UNLABELLED: The use of a patient-triggered and automatic event recorder is documented in a 17-month-old girl presenting with paroxysmal episodes of loss of consciousness. After pacemaker implantation, the paroxysmal attacks disappeared. CONCLUSION: we recommend a more frequent use of the event recorder in the investigation of syncope, especially in small children.

Electrocardiography, Ambulatory↗