PubMed Health⌕ Search

Biomedical subjects

Katrin Salchert

Publications and source records attributed to Katrin Salchert.

10 recordsLinked to original sources

Electrostatic interactions modulate the conformation of collagen I.

The pH- and electrolyte-dependent charging of collagen I fibrils was analyzed by streaming potential/streaming current experiments using the Microslit Electrokinetic Setup. Differential scanning calorimetry and circular dichroism spectroscopy were applied in similar electrolyte solutions to characterize the influence of electrostatic interactions on the conformational stability of the protein. The acid base behavior of collagen I was found to be strongly influenced by the ionic strength in KCl as well as in CaCl(2) solutions. An increase of the ionic strength with KCl from 10(-4) M to 10(-2) M shifts the isoelectric point (IEP) of the protein from pH 7.5 to 5.3. However, a similar increase of the ionic strength in CaCl(2) solutions shifts the IEP from 7.5 to above pH 9. Enhanced thermal stability with increasing ionic strength was observed by differential scanning calorimetry in both electrolyte systems. In line with this, circular dichroism spectroscopy results show an increase of the helicity with increasing ionic strength. Better screening of charged residues and the formation of salt bridges are assumed to cause the stabilization of collagen I with increasing ionic strength in both electrolyte systems. Preferential adsorption of hydroxide ions onto intrinsically uncharged sites in KCl solutions and calcium binding to negatively charged carboxylic acid moieties in CaCl(2) solutions are concluded to shift the IEP and influence the conformational stability of the protein.

Amino Acid Sequence↗

Gene-expression profiling of CD34+ hematopoietic cells expanded in a collagen I matrix.

CD34+ hematopoietic stem/progenitor cells (HSCs) reside in the bone marrow in close proximity to the endosteal bone surface, surrounded by osteoblasts, stromal cells, and various extracellular matrix molecules. We used a bioartificial matrix of fibrillar collagen I, the major matrix component of bone, as a scaffold for ex vivo expansion of HSCs. CD34+ HSCs were isolated from umbilical cord blood and cultivated within reconstituted collagen I fibrils in the presence of fms-like tyrosine kinase-3 ligand, stem cell factor, and interleukin (IL)-3. After 7 days of culture, the cell number, number of colony-forming units (CFU-C), and gene-expression profile of the cultured cells were assessed. Although the total expansion factor of CD34+ cells was slightly lower when cells were cultivated in the collagen I gel, the frequency of CFU-C was greater than in control suspension cultures. Gene-expression analysis with microarray chip technology revealed the upregulation of more than 50 genes in the presence of collagen I. Among these, genes for several growth factors, cytokines, and chemokines (e.g., IL-8 and macrophage inhibitory protein 1alpha) could be confirmed using quantitative polymerase chain reaction. Furthermore, greater expression levels of the negative cell-cycle regulator BTG2/TIS21 and an inhibitor of the mitogen-activated protein kinase pathway, DUSP2, underline the regulatory role of the extracellular matrix. Together, these data show that the expansion of CD34+ cord blood cells in a culture system containing a three-dimensional collagen I matrix induces a qualitative change in the gene-expression profile of cultivated HSCs.

Antigens, CD34↗

Fibronectin displacement at polymer surfaces.

The interactions of fibronectin with thin polymer films are studied in displacement experiments using human serum albumin. Fibronectin adsorption and exchange on two different maleic anhydride copolymer surfaces differing in hydrophobicity and surface charge density have been analyzed by quartz crystal microbalance and laser scanning microscopy with respect to adsorbed amounts, viscoelastic properties, and conformation. Fibronectin is concluded to become attached onto hydrophilic surfaces as a "softer", less rigid protein layer, in contrast to the more rigid, densely packed layer on hydrophobic surfaces. As a result, the fibronectin conformation is more distorted on the hydrophobic substrates together with remarkably different displacement characteristics in dependence on the adsorbed fibronectin surface concentration and the displacing albumin solution concentration. While the displacement kinetic remains constant for the strongly interacting surface, an acceleration in fibronectin exchange is observed for the weakly interacting surface with increasing fibronectin coverage. For displaced amounts, no change is determined for the hydrophobic substrate, in contrast to the hydrophilic substrate with a decrease of fibronectin exchange with decreasing coverage leading finally to a constant nondisplaceable amount of adsorbed proteins. Furthermore, the variation of the albumin exchange concentration reveals a stronger dependence of the kinetic for the weakly interacting substrate with higher rates at higher albumin concentrations.

Journal Article↗

Immobilization of an anticoagulant benzamidine derivative: effect of spacer arms and carrier hydrophobicity on thrombin binding.

Prevention of blood coagulation is very often a prerequisite for successful medical devices. For that purpose, passivation of the key coagulation enzyme thrombin through the derivatization of the material's surface with an amidine-based molecule has been found to be promising. To further enhance the efficiency of this approach, thin layers of maleic anhydride copolymers offering different physico-chemical characteristics were tethered with carboxyl terminated polyethylene glycol to covalently immobilize a benzamidine-type derivative. The free carboxyl surface groups produced by the attachment of polyethylene glycol (PEG) were quantified by Ag(+) labeling and subsequent XPS detection. The film thickness as well as the carboxyl group content were found to be clearly dependent on the copolymer hydrophobicity and the nature of the PEG molecule. For the assessment of the anchorage of the thrombin to the benzamidine-derivative functionalized surfaces, the substrates were immersed in a buffered thrombin solution and the enzyme adsorption was studied using immunostaining/confocal laser scanning microscopy. Higher degrees of thrombin binding were observed for substrates configured with the hydrophilic compared to the more hydrophobic copolymer. Moreover, surface-bound spacers based on alpha,omega-heterobifunctional PEG amino acids (alphaAm,omegaAc-PEG) also enhanced the benzamidine surface density in comparison to homofunctional PEG diacids (alphaAc,omegaAc-PEG) because of a lower degree of carboxyl inactivation due to PEG 'bridging'. Altogether, the choice of copolymer coatings and the type of PEG spacers were demonstrated to enhance the efficiency of the thrombin scavenging by the covalently immobilized coagulation inhibitor.

Adsorption↗

Dynamic alterations of fibronectin layers on copolymer substrates with graded physicochemical characteristics.

Desorption and exchange of preadsorbed fibronectin layers in pure buffer solution and solutions of human serum albumin or fibronectin, respectively, were studied in dependence on the physicochemical characteristics of maleic acid copolymer films used as substrates. Although the preadsorbed amount of fibronectin differed only slightly, the protein was found to exhibit a significantly enhanced anchorage at the more hydrophobic polymer surface as compared to the more hydrophilic and more negatively charged polymer surface. The preadsorbed fibronectin layer was most efficiently exchanged by fibronectin (i.e., in the homodisplacement process) while pure buffer solution and human serum albumin solutions induced desorption or exchange of fibronectin to lower and similar degrees. An increase of the total adsorbed amount of protein due to additional adsorption of fibronectin or human serum albumin accompanied the partial exchange of the preadsorbed fibronectin in the displacement experiments. Evaluation of the kinetics of desorption and exchange of fibronectin at any of the substrates revealed two kinds of surface-attached protein populations--a fast desorbing species and a species with a slow desorption and exchange rate. By a multivariate regression analysis the surface characteristics of the polymer substrate were confirmed to determine the degree of protein desorption and exchange while the dynamics of the layer alteration was found to solely depend on the diffusion behavior of the proteins.

Chemical Phenomena↗

Comparison of flow cytometry and laser scanning cytometry for the analysis of CD34+ hematopoietic stem cells.

BACKGROUND: Characterization of hematopoietic stem cells (HSCs) by laser scanning cytometry (LSC) was compared with conventional flow cytometry (FCM). The method was evaluated for application in the development of advanced cell culture substrates that were supposed to support the ex vivo expansion of HSC. For this purpose, adherent HSCs were grown in culture on thin polymer films coated with reconstituted collagen I fibrils and subsequently analyzed by LSC. METHODS: CD34+ HSCs were isolated from cord blood by immunomagnetic separation and cultivated on polymer films coated with reconstituted collagen I fibrils. Cell surface antigens (CD34, CD29) were stained with antibodies, and nuclei were labeled with a DNA stain (TO-PRO-3 iodide) that does not interfere with the fluorochromes of the antibodies. Fluorescence intensity of the adherent cells was measured by means of LSC. Before and after in vitro expansion for time periods of up to 7 days, suspension cells were analyzed with LSC and FCM. RESULTS: LSC-based analysis enabled reliable quantification of CD34+ cells with bright antigen expression before cell culture. At this stage, LSC and FCM data for CD34 expression at given HSC samples largely coincided. After in vitro expansion, LSC data deviated from FCM data for cells with dim CD34 antigen expression, whereas the fluorescence intensity of the CD29 antigen remained comparable. The deviation between LSC and FCM data for CD34dim was attributed to the better resolution of weak fluorescence by FCM. Based on the preceding evaluation of the method, LSC analysis could be applied to characterize HSCs cultivated on collagen I-coated polymer films without detachment of the cells from the substrate. CONCLUSIONS: LSC-based analysis allows for the automated evaluation of adherent HSCs. Although resolution of weakly expressed antigens can be achieved more precisely with FCM, the method provides a valuable tool to study interactions of HSCs with bioartificial substrates.

Antigens, CD34↗

Fibronectin anchorage to polymer substrates controls the initial phase of endothelial cell adhesion.

Early stages of the adhesion of human endothelial cells onto a set of smooth polymer films were analyzed to reveal the modulation of cell-matrix interactions by the physicochemical constraints of predeposited fibronectin (FN). Hydrophobic and hydrophilic polymer substrates, consisting of poly(octadecene-alt-maleic anhydride) and poly(propene-alt-maleic anhydride) films, were coated with similar amounts of FN at conditions of either covalent or noncovalent immobilization. The well-defined substrates permit variation of the anchorage of FN at invariant topography, pliability, and molecular composition. Although all of the compared FN coatings were effective in stimulating attachment of endothelial cells, the initial formation of cell-matrix adhesions was found to be controlled by the type of interaction between predeposited FN and the underlying substrate. Covalent linkage and hydrophobic interactions of the predeposited FN with the polymer films interfered with the rapid generation of focal and fibrillar adhesions. It was demonstrated that this was caused by the fact that only weakly bound FN could become readily reorganized by the adherent cells. Upon prolonged culture periods at standard cell culture conditions, secretion and deposition of organized extracellular matrix by the attached cells was found to balance out the differences of the substrates.

Biocompatible Materials↗

Quantitative analysis of immobilized proteins and protein mixtures by amino acid analysis.

Biomolecular surface engineering of materials often requires precise, versatile and efficient quantification of immobilized proteins at solid surfaces. Acidic hydrolysis of surface-bound proteins and subsequent HPLC analysis of fluorescence-derivatized amino acids were adapted and critically evaluated for that purpose. Contaminations and concentration-dependent amino acid retrieval during HPLC were found to influence the accuracy of the method. In addition to the choice of adequate conditions for hydrolysis, derivatization and chromatographic separation extensions of the data evaluation were suggested to improve the accuracy of the approach when applied to single protein systems: comparing the experimentally obtained amino acid ratio to the protein constitution enabled to identify the properly separated and detected amino acids. Those amino acids were selected for a more precise calculation of the amount of immobilized protein. To further increase the accuracy of the method, the retrieval of amino acids corresponding to protein amounts in the range between 0.5 and 4.0 microg was analyzed for a variety of proteins of interest to derive protein-specific correction factors. The evaluation of amino acid data was furthermore applied to quantify binary protein mixtures at similar settings. This method was proven useful to detect the composition of protein mixtures throughout a wide range of absolute and relative concentrations.

Amino Acids↗

Maleic anhydride copolymers--a versatile platform for molecular biosurface engineering.

A platform of thin polymer coatings was introduced for the functional modulation of immobilized bioactive molecules at solid/liquid interfaces. The approach is based on covalently attached alternating maleic acid anhydride copolymers with a variety of comonomers and extended through conversion of the anhydride moieties by hydrolysis, reaction with functional amines, and other conversions of the anhydride moieties. We demonstrate that these options permit control of the physicochemical constraints for bioactive molecules immobilized at interfaces to influence important performance characteristics of biofunctionalized materials for medical devices and molecular diagnostics. Examples concern the impact of the substrate-anchorage of fibronectin on the formation of cell-matrix adhesions, the orientation of endothelial cells according to lateral anti-adhesive micropatterns using grafted poly(ethylene oxide), and the spacer-dependent activity of immobilized synthetic thrombin inhibitors.

Amines↗

In vitro reconstitution of fibrillar collagen type I assemblies at reactive polymer surfaces.

The reconstitution of fibrillar collagen and its assemblies with heparin and hyaluronic acid was studied in vitro. Fibril formation kinetics were analyzed by turbidity and depletion measurements in solutions containing varied concentrations of collagen and glycosaminoglycans. Fibril-forming collagen solutions were further applied for the coating of planar substrates which had been modified with alternating maleic anhydride copolymer films before. The immobilized collagen assemblies were characterized with respect to the deposited amount of protein using ellipsometry and acidic hydrolysis/HPLC-based amino acid analysis, respectively. AFM, SEM, and cLSM were utilized to gain information on structural features and patterns formed by surface-attached fibrils depending on the initial solution concentrations of collagen. The results revealed that the addition of heparin and hyaluronic acid affected both the fibril dimensions and the meshwork characteristics of the surface-bound fibrils.

Amino Acids↗