Reproducibility of organ position using voluntary breath-hold method with spirometer for extracranial stereotactic radiotherapy.

PURPOSE: To evaluate in healthy volunteers the reproducibility of organ position using a voluntary breath-hold method with a spirometer and the feasibility of this method for extracranial stereotactic radiotherapy in a clinical setting. METHODS AND MATERIALS: For this study, 5 healthy volunteers were enrolled. After training sessions, they held their breath at the end-inspiration and the end-expiration phase under spirometer-based monitoring. Computed tomography (CT) scans were performed twice at each respiratory phase, with a 10-min interval, on 2 separate days. The total number of CT scans was four at each respiratory phase. After CT volume data were transferred to a three-dimensional treatment-planning system, digitally reconstructed radiographs (DRRs) were calculated for anterior-posterior and left-right beams. Verification was performed with DRRs relative to the diaphragm position, bony landmarks, and the isocenter in each healthy volunteer at each respiratory phase. To evaluate intrafraction reproducibility, we measured the distance between diaphragm position and bony landmarks. To evaluate interfraction reproducibility, we measured the distance between diaphragm position and the isocenter. Reproducibility and setup error were defined as the average value of the differences between each DRR with regard to the first DRR. RESULTS: Intrafraction reproducibility of the caudal-cranial direction was 4.0 +/- 3.5 mm at the end-inspiration phase and 2.2 +/- 2.0 mm at the end-expiration phase. Interfraction reproducibility of the caudal-cranial direction was 5.1 +/- 4.8 mm at the end-inspiration phase and 2.1 +/- 1.8 mm at the end-expiration phase. The end-expiration phase was more stable than the end-inspiration phase. CONCLUSIONS: The voluntary breath-hold method with a spirometer is feasible, with relatively good reproducibility. We are encouraged about the use of this technique clinically for extracranial stereotactic radiotherapy.

Diaphragm↗

Coronary artery calcium scoring using 16-MDCT and a retrospective ECG-gating reconstruction algorithm.

OBJECTIVE: Our aim was to compare detection, quantification, and cardiovascular risk stratification of coronary artery calcium (CAC) between electron beam CT and 16-MDCT with retrospective reconstruction. SUBJECTS AND METHODS. One hundred patients underwent both electron beam CT and 16-MDCT, and coronary artery calcium score, volume, and mass were obtained. RESULTS: Correlation between the two CT scanners was high for both calcium score (r(2) = 0.955), volume (r(2) = 0.952), and mass (r(2) = 0.977). Although electron beam CT is viewed as the gold standard, the sensitivity and specificity in the detection of CAC using 16-MDCT with a threshold of 130 H were 98.7% and 100%, respectively. The variability of calcium scores between the two CT scanners (26.5%) was comparable with two electron beam CT scanners reported previously. The variability of calcium volume (20.7%) and mass (20.3%) was lower than that of the score (Student's t test, r = 0.05, 0.01). In clinical cardiovascular risk stratification based on two CT calcium scores, the Cohen's kappa value was 0.929. There was no significant difference between the two scanners using Wilcoxon's signed rank test (p = 0.157). CONCLUSION: The 16-MDCT scanner with retrospective reconstruction, showing high agreement for detection and quantification of CAC with electron beam CT, holds promise in the detection of coronary artery atherosclerosis.

Algorithms↗

Estimating the stenosis probabilities in arteriosclerosis obliterans using generalized estimating equations.

For each of 211 arteriosclerosis obliterans patients, the degree of stenosis of arteries at four sites were examined at Hiroshima University Hospital to analyse the relationship between the degree of stenosis and age, sex and site. The generalized estimating equations using a proportional odds model for the stenosis probability with exchangeable correlation was applied to this clustered, ordered polytomous data. Since the correlations between the responses were quite small, we could apply the independence estimating equations. The best mean model selected by Akaike information criterion suggested that age dependency of the stenosis probability was not observed in the central sites but was observed in the peripheral sites, and symmetry of the risk of stenosis was seen in the left and right sites. Details of the analysis will be described.

Adult↗

[Is intravenous contrast enhancement effective in improving CT diagnosis of hepatic disease?].

PURPOSE: The purpose of this study was to evaluate the effectiveness of contrast enhancement in the diagnosis of hepatic disease. MATERIALS AND METHODS: 2761 cases involving CT of the liver and abdomen were analyzed using logistic analysis. CT was either helical-CT (SDCT) or multi-detector CT (MDCT), with power injector. RESULTS: Contrast enhancement use was 92% in liver disease and 95% in tumor cases. A typical case involved a 66-year-old man given 2-4 ml/sec of contrast material using dual injection. CT imaging was done in the equilibrium stage. The use of contrast material was effective for the diagnosis of liver tumor except in the qualitative diagnosis of hepatocellular carcinoma with SDCT where the odds ratio was 0.084. CONCLUSION: Intravenous contrast enhancement was effective for the CT diagnosis of hepatic tumor. Dynamic CT was effective using MDCT, and dual injection of contrast material was also valid for SDCT. Multiphasic studies were needed for detecting liver tumors not only on MDCT but also on SDCT. CT imaging during the equilibrium phase alone is inadequate to document diagnosis of metastatic liver tumors. The addition of various phasic contrast materials during CT was effective in evaluating liver tumors that showed angiogenesis.

Aged↗

[Concurrent chemoradiation experience of recurrent gastric cancers resistant to TS-1].

We report our experience with concurrent chemoradiation for recurrent gastric cancers resistant to TS-1. From April 2000 to March 2003, we treated 10 consecutive patients with radiation and the concurrent single chemotherapy agent of TS-1 or CPT-11. Of the 10 patients, 3 (30%) had a complete response, 4 (40%) a partial response, and 3 (30%) stable disease, yielding an overall response rate of 70% (7/10). Three patients are alive and cancer-free, 5 patients died with cancers, and 2 patients are living with cancers as outpatients. The clinical benefit response was 90% (9/10). No patient has had either acute or late complication. Concurrent chemoradiation is feasible and seems to offer good results for recurrent gastric cancers resistant to TS-1.

Aged↗

Use of multidetector row CT with volume renderings in right lobe living liver transplantation.

Multidetector row CT is a feasible diagnostic tool in pre- and postoperative liver partial transplantation. We can assess vascular anatomy and liver parenchyma as well as volumetry, which provide useful information for both donor selection and surgical planning. Disorders of the vascular and biliary systems are carefully observed in recipients. In addition, we evaluate liver regeneration of both the donor and the recipient by serial volumetry. We present how multidetector row CT with state-of-the-art three-dimensional volume renderings may be used in right lobe liver transplantation.

Blood Volume↗

Hepatic arterial infusion of 5-fluorouracil and cisplatin for unresectable or recurrent hepatocellular carcinoma with tumor thrombus of the portal vein.

BACKGROUND AND OBJECTIVES: This study was designed to evaluate the efficacy of hepatic arterial infusion of 5-fluorouracil (5-FU) and cisplatin (CDDP) for unresectable or recurrent hepatocellular carcinoma (HCC) with tumor thrombus of the trunk or first branches of the portal vein (PVTT). METHODS: Seven unresectable or recurrent HCC patients with PVTT were enrolled in this study. A one-week course of chemotherapy consisted of intraarterial administration of CDDP (10 mg on days 1-5) for 1 h and 5-FU (250 mg on days 1-5) for 24 h, followed by cessation of administration for the subsequent 2 days (days 6 and 7). Three or more sequential courses of chemotherapy were given through an implanted reservoir. RESULTS: Serum alpha-fetoprotein (AFP) levels before the chemotherapy were >20 ng/ml in six of the seven patients. Serum AFP levels were decreased in four of the six patients after chemotherapy, including two patients (cases 1 and 7) whose AFP levels later returned to normal. Six of the seven patients had measurable lesions in the liver, with a response rate of 33%. In three of the seven patients (43%), PVTTs decreased in size or disappeared after chemotherapy. The mean and median survival periods of all patients were 8.0 and. 7.5 months, respectively. CONCLUSIONS: The chemotherapy described in this report is beneficial in terms of survival for HCC patients with PVTT for whom transcatheter arterial embolization or surgical treatment is contraindicated.

Aged↗

Three-dimensional navigator for retroperitoneal laparoscopic nephrectomy using multidetector row computerized tomography.

PURPOSE: We evaluated the efficacy of a 3-dimensional (D) navigator for retroperitoneal laparoscopic nephrectomy. MATERIALS AND METHODS: A total of 21 patients with malignant localized renal (16) or ureteral (5) neoplasms underwent multi-detector row computerized tomography. The 3-D navigator was created using volume rendering technique. These findings were compared with videos obtained during laparoscopy. RESULTS: The 3-D navigator depicted all renal arteries (100% sensitivity) and 24 of the 25 renal veins (96% sensitivity). Hilar anatomy, including the tumor, major vessels and adrenal gland, and their relationships were visualized as in laparoscopic views. CONCLUSIONS: The 3-D navigator has a potentially important role in retroperitoneal laparoscopic nephrectomy. It is able to guide surgeons and aid in avoiding operative risks and possible complications.

Adult↗

Comparison of small intestinal submucosa-covered and noncovered nitinol stents in sheep iliac arteries: a pilot study.

PURPOSE: To compare the biocompatibility and performance of nitinol endografts covered externally or internally with small intestinal submucosa (SIS) with bare nitinol stents in medium-sized arteries. MATERIALS AND METHODS: Eighteen nitinol Zilver stents were used: six externally SIS-covered endografts (ECEs), six internally SIS-covered endografts (ICEs), and six bare stents (BSs). Devices were implanted in the balloon-injured external iliac arteries (EIAs) of nine female sheep via carotid approach. Arteriograms were obtained before and after implantation and before animal sacrifice at 1, 3, and 6 months. Histologic studies of explanted specimens were performed. RESULTS: Implantation of all BSs, ECEs, and ICEs was successful, but slight luminal narrowing of 19% +/- 5.3% (range, 12%-28%) was seen in ICEs on postimplantation angiograms. At sacrifice, all six BSs and ECEs were patent, with BSs showing a mean angiographic luminal narrowing of 8.4% +/- 7.2% (range, 0%-18%) and ECEs showing a mean angiographic luminal narrowing of 16% +/- 7.5% (range, 6.5%-26%) as a result of neointimal hyperplasia. Four ICEs showed luminal narrowing of 21% +/- 17% (range, 0%-35%) as a result of marked neointimal hyperplasia and two were occluded, one at 3 months and the other at 6 months. ECEs and BSs showed approximately 80% lumen endothelialization at 1 month, which increased to 100% at 3 and 6 months. ICEs did not show complete endothelialization. CONCLUSION: The BS had the least vessel wall reaction. ECEs exhibited early endothelialization with early mild to moderate wall reaction decreasing at the late study stages. ICEs showed extensive wall reaction, possibly as a result of technical problems with SIS attachment.

Alloys↗

Balloon-occluded retrograde transvenous obliteration of gastric fundal varices with hemorrhage.

OBJECTIVE: This study was performed to evaluate the clinical efficacy, feasibility, and complications of balloon-occluded retrograde transvenous obliteration for patients with hemorrhage from gastric fundal varices. SUBJECTS AND METHODS: Between December 1994 and February 2001, 24 consecutive patients with hemorrhage from gastric fundal varices were enrolled in this study. Balloon-occluded retrograde transvenous obliteration consisted of injecting 5% ethanolamine oleate iopamidol through the outflow vessels during balloon occlusion. The treatment was performed during acute bleeding in 11 patients and electively in 13 patients. Among those patients with acute bleeding, six were treated for temporary hemostasis with balloon tamponade, and five were treated endoscopically. RESULTS: Cannulation into the outflow vessels was performed in 23 patients, but the balloon catheter could not be inserted in one patient who had inferior phrenic vein outflow. Complete success was obtained in 88% (21/24) of patients, and partial success was obtained in two patients. In nine of 11 patients with acute bleeding, complete success was achieved. Rebleeding from gastric varices was not observed in patients treated with complete success, whereas two patients treated partially rebled within 1 week of the treatment (rate of rebleeding, 9%). Eradication of gastric varices was obtained in all patients (n = 19) who were examined by endoscopy 3 months after the treatment. Eight patients experienced worsening of esophageal varices. These patients were treated endoscopically because of findings that suggested a risk of hemorrhage. The overall mortality rate was 4% (1/24). No damage to the kidney was observed, although 11 patients had macrohematuria. CONCLUSION: Balloon-occluded retrograde transvenous obliteration followed by any hemostatic procedure might be effective for both prophylaxis of rebleeding and eradication of gastric fundal varices, even in urgent cases.

Adult↗

Technical innovation of cardiac multirow detector CT using multisector reconstruction.

Multisector reconstruction is a newly developed algorithm for multirow detector CT in cardiac study. Using volume data sets obtained by ECG-gated scanning, we can reconstruct cardiac images at any desired phase of the cardiac cycle retrospectively. In retro-processing multiplanar and three-dimensional images, thin-slice images with overlapping increment have a great advantage due to increasing z-axis resolution. In this article, we present principles of the algorithm, a phantom study, clinical applications and perspectives for the future.

Adult↗

Coronary artery calcium scoring using multicardiac computed tomography.

OBJECTIVES: To test the hypothesis that multicardiac-phase computed tomography (CT) improves the quantification of coronary artery calcium. METHODS: Calcium-phosphate on a cardiac phantom and 108 calcified plaques from 50 patients were scanned, and multicardiac-phase images were obtained. Motion artifacts and calcium scores of the calcified plaques were compared between cardiac phases and CT scanners. RESULTS: In the phantom images, motion artifacts differed between cardiac phases; thus, the calcium scores were either higher or lower than the score from the static state. In the patient study, motion artifacts of calcifications on the various coronary branches varied with the cardiac cycle, which profoundly influenced the calcium scores. CONCLUSION: Multicardiac-phase CT has the potential to improve the quantification of coronary artery calcium by determining the cardiac phase where motion artifacts are the least on individual calcified plaques.

Aged↗