Selective detection of a catecholamine against electroactive interferents using an interdigitated heteroarray electrode consisting of a metal oxide electrode and a metal band electrode.

We developed an interdigitated array electrode (IDAE) consisting of a metal oxide electrode and a metal band heteroelectrode and employed it for the selective detection of catecholamines. We used an indium-tin oxide (ITO) film as the oxidation electrode of the IDAE because the ITO was able to suppress response currents from L-ascorbic acid (AA) and uric acid (UA), which are major electroactive interferents in biological fluids. However, the ITO film also suppresses the reduction of quinones including oxidized catecholamines. We developed a simple technique for fabricating our hetero IDAE, which also preserves the electrochemical properties of the ITO. When we compared hetero ITO-gold, homo ITO-ITO, and carbon-carbon IDAEs, we found that the hetero IDAE provided both high sensitivity and selectivity for DA detection. We achieved high selectivities for DA against AA and UA. The ratios of the response currents of AA and UA to DA were calculated as 6 and 5%, respectively.

Catecholamines↗

Biocompatible glucose sensor prepared by modifying protein and vinylferrocene monomer composite membrane.

This paper proposes a very simple procedure for preparing a biocompatible sensor based on a protein (bovine serum albumin, BSA), enzyme and vinylferrocene (VF) composite membrane modified electrode. The membrane was prepared simply by first casting vinylferrocene and then coating it with BSA and glucose oxidase immobilised with glutaraldehyde. The sensor response was independent of dissolved oxygen concentration from 3 to 10 ppm and showed good stability for serum sample measurement, unlike the commonly used BSA/enzyme modified electrode. The sensor response was almost unchanged over the measurement time (>10 h) whereas the responses of a BSA and glucose oxidase modified platinum electrode and an osmium-polyvinylpyridine wired horseradish peroxidase modified electrode (Ohara et al., 1993) fell to 68% of their initial value in a serum sample containing 10mM glucose.

Biocompatible Materials↗

An amperometric detector formed of highly dispersed Ni nanoparticles embedded in a graphite-like carbon film electrode for sugar determination.

We achieved improved detection limits for sugars by developing a novel thin film containing 0.8% highly dispersed Ni nanoparticles in disordered graphite-like carbon (Ni-NDC) as a detection electrode for high-performance liquid chromatography. The Ni-NDC film was prepared in one step by a simple radio frequency (rf) sputtering method at a temperature below 200 degrees C. We characterized the film by XPS, TEM, and AFM analysis and found that the average Ni nanoparticle size was 3 nm and that the film consisted of a mixture of Ni, NiO, Ni2O3, and Ni(OH)2. We studied the electrochemical detection of sugars using the 0.8% Ni-NDC film electrode. The film electrode had excellent electrocatalytic ability and good stability compared with a Ni-bulk electrode with regard to the electrooxidation of sugars. We employed the Ni-NDC film as an HPLC detection electrode. We achieved a good separation of four sugars (glucose, fructose, sucrose, lactose) at a relatively low constant detection potential (0.40 V vs Ag/AgCl) and a linearity of over 3 orders of magnitude. We obtained improved detection limits for the investigated sugars, namely, 20, 25, 50, and 37 nM for glucose, fructose, sucrose, and lactose, respectively. This is at least 1 order of magnitude lower than the detection limits obtained with a Ni-bulk electrode with the same measurement condition. The Ni-NDC film electrode also showed good reproducibility with a relative standard deviation of 1.75% for 40 consecutive injections of glucose in a flow system.

Carbon↗

Selective detection of L-glutamate using a microfluidic device integrated with an enzyme-modified pre-reactor and an electrochemical detector.

A microfluidic device integrated with a nanoliter volume enzyme pre-reactor and an enzyme-modified electrode was developed for the highly selective continuous measurement of glutamate (Glu). The device consists mainly of two glass plates. One plate incorporates an electrochemical cell that consists of working electrode (WE), reference electrode (RE) and counter electrode (CE). The WE is modified with a bilayer film of Os-polyvinylpyrridine-based mediator containing horseradish peroxidase (Os-gel-HRP). The WE was operated at -50 mV versus Ag. The other plate has a thin layer flow channel integrated with a pre-reactor. The reactor has a number of micropillars (20 microm in diameter, 20 microm high and separated from each other by a 20 microm gap) modified with ascorbate oxidase (AAOx) to eliminate L-ascorbic acid (AA). The enzymatic oxidation of AA is superior to that obtained with our previously reported pre-electrolysis type micro-reactor since electrochemically reversible transmitters such as catecholamines do not provide a cathodic current at the WE. In addition, the high operation potential of the pre-reactor causes unknown electroactive species, which also cause interference at the detection electrode. As a result, we were able to detect 1 microM Glu continuously at a low flow rate even when AA concentration was 100 microM.

Ascorbic Acid↗

Continuous measurement of glutamate and hydrogen peroxide using a microfabricated biosensor for studying the neurotoxicity of tributyltin.

We first measured the effects of trace levels of an endocrine disruptor, tributyltin (TBT), on the secretion response from nerve cells using a microfabricated biosensor designed for the continuous measurement of L-glutamate and hydrogen peroxide. We observed higher and long-lasting glutamate and hydrogen peroxide concentrations from the cells when cultured rat cortical neurons were exposed to TBT. Glutamate and hydrogen peroxide release was induced even when we reduced the TBT concentration to 10 nM. This concentration is about two orders of magnitude lower than the concentration that induced apoptosis-like cell death. We also report on the effects of NMDA and non-NMDA receptor antagonists, which can help us to understand the mechanism of TBT neurotoxicity.

Animals↗

Differential measurement with a microfluidic device for the highly selective continuous measurement of histamine released from rat basophilic leukemia cells (RBL-2H3).

We fabricated a micro-fluidic device for the highly selective detection of the histamine released from rat basophilic leukemia (RBL) 2H3 cells. The device has two thin layer flow channels, each with one working electrode. One electrode was modified with Os-polyvinylpyridine based mediator containing horseradish peroxidase (Os-gel-HRP) and histamine oxidase (HAOx), the other was modified with Os-gel-HRP without any HAOx. We employed the device for differential measurement by using the HAOx modified electrode for detection and the unmodified electrode as a reference. The detection limit was greatly improved from 190 to 25 nM since the baseline noise level was suppressed. We used differential measurement to observe the histamine released from RBL-2H3 cells when stimulated with dinitrophenylated bovine serum albumin (DNP-BSA) as an antigen. We injected 5 microM of histamine solution into our device and it remained stable for more than 8 h.

Animals↗