PubMed Health⌕ Search

Biomedical subjects

Kay Niemax

Publications and source records attributed to Kay Niemax.

7 recordsLinked to original sources

Differential surface plasmon resonance imaging for high-throughput bioanalyses.

A new imaging technique for high-throughput surface plasmon resonance (SPR) measurements is described. It is the application of a CCD camera for simultaneous processing of two images at two different wavelengths provided by two laser diodes. The two lasers are brought to resonance by tuning of the angle of incidence so that the detection power and the dynamic range are optimized for the wavelength pair selected. Applying a special differential processing of the two images, SPR measurements can be performed near the shot noise limit taking into account the number of CCD pixels involved. It is shown that the detection limit of imaging methods can be improved significantly if the working point is set near to the reflection minimum instead of choosing the angle with the steepest slope of the reflection curve. The technique is demonstrated by simultaneous measurement of hybridization reactions of three different types of thiolated oligonucleotides in 30 small areas set by a commercial spotter. A noise level of 1.5 x 10(-6) refractive index units (RIU) was obtained for single, 500 x 500 microm2 reaction areas. The noise level was about 6 x 10(-7) RIU when five areas were taken into account. The present arrangement and the particular spotter applied would allow simultaneous measurements of up to 400 binding reactions with a noise level of about 1.5 x 10(-6) RIU.

DNA↗

Production of ultrafine particles by nanosecond laser sampling using orthogonal prepulse laser breakdown.

The particle size distribution and composition of nanosecond laser-generated aerosols from brass samples in atmospheric argon has been measured by low-pressure impaction and subsequent quantitative analysis of the aerosols by total reflection X-ray fluorescence. Ablation was performed applying a Nd:YAG laser at 1.06 microm both without and with a prepulse plasma breakdown generated by a second Nd:YAG laser at 2-60 micros prior to the ablation pulse. The beam of the prepulse laser had orthogonal direction to the ablation laser beam, and the breakdown was produced 2.5 mm above the ablation spot. Ultrafine aerosol particles (<50 nm) were generated in the double-pulse experiment representing practically the total mass impacted, while in single-pulse ablation the proportion of large particles (>0.1 microm) was dominating. The predominance of ultrafine aerosols in the prepulse experiment indicates that particle formation from vapor-phase condensation is the major mechanism, while the appearance of large particles in single-pulse ablation points at fragmentary evaporation in the laser-produced plasma. It was also shown that the total mass impacted in double-pulse ablation increases almost linearly with the power of the prepulse laser. The better atomization and the larger sample mass ablated can be assumed to be the main reasons for the increase of the line intensities in double-pulse laser-induced breakdown spectrometry with orthogonal prepulses reported by several research groups.

Journal Article↗

Double-wavelength technique for surface plasmon resonance measurements: basic concept and applications for single sensors and two-dimensional sensor arrays.

A new technique for on-line monitoring of analyte binding to sensor surfaces by surface plasmon resonance (SPR) detection is described. It is based on differential measurements using two wavelengths provided by two diode lasers. The technique is as simple and robust as the conventional SPR detection measuring the reflected radiation at fixed incidence angle, but it has the advantage of being nonsensitive to variations of the resonance width and providing essentially higher signal/noise ratios. The paper presents the first four channel prototype system for parallel 2D-monitoring at four different spots. One channel is always used as a reference to compensate temperature fluctuations and nonspecific adsorptions. Calibration with sucrose solutions revealed an absolute sensitivity of Deltan approximately 5 x 10(-6). The new technique is tested with a biotin-streptavidin binding and with hybridization/denaturation of DNA. Biotin binding to a streptavidin monolayer is detected with a signal/noise ratio of about 5, which demonstrates the high potential of the new technique for applications in drug discovery. Applications to gene analysis are tested with short oligonucleotides of the sequences used for genotyping human hepatitis C viruses. A selective response to complementary oligonucleotides is observed. The high reproducibility in subsequent cycles of hybridization/denaturation (by formamide or by heating) points out potential applications of the technique in medical diagnostics, food industry, genomics, and proteomics too.

Biosensing Techniques↗

Imaging of the expansion of femtosecond-laser-produced silicon plasma atoms by off-resonant planar laser-induced fluorescence.

Planar laser-induced fluorescence measurements were used to investigate the expansion dynamics of a femtosecond laser-induced plasma. Temporally and spatially resolved measurements were performed to monitor the atoms that were ablated from a silicon target. A dye laser (lambda = 288.16 nm) was used to excite fluorescence signals. The radiation of an off-resonant transition (Si 390.55 nm) was observed at different distances from the target surface. This allowed easy detection of the ablated Si atoms without problems caused by scattered laser light. Abel inversion was applied to obtain the radial distribution of the Si atoms. The atom distribution in the plasma shows some peculiarities, depending on the crater depth.

Journal Article↗

Application of femtosecond laser ablation time-of-flight mass spectrometry to in-depth multilayer analysis.

A femtosecond laser system was used in combination with a time-of-flight mass spectrometer (TOF-MS) for in-depth profiling of semiconductor and metal samples. The semiconductor sample was a Co-implanted (10(17) ions/cm3) silicon wafer that had been carefully characterized by other established techniques. The total depth of the shallow implanted layer was 150 nm. As a second sample, a thin film metal standard had been used (NIST 2135c). This standard consisted of a silicon wafer with nine alternating Cr and Ni layers, each having a thickness of 56 and 57 nm, respectively. An orthogonal TOF-MS setup was implemented. This configuration was optimized until a sufficient mass resolution of 300 (m/delta m) and sensitivity was achieved. The experiments revealed that femtosecond-laser ablation TOF-MS is capable of resolving the depth profiles of these demanding samples. The poor precision of the measurements is discussed, and it is shown that this is due to pulse-to-pulse stability of the current laser system. Femtosecond-laser ablation TOF-MS is shown to be a promising technique for rapid in-depth profiling with a good lateral resolution of various multilayer thin film samples.

Journal Article↗