Kazuhiko Himuro

Publications and source records attributed to Kazuhiko Himuro.

4 recordsLinked to original sources

[Image quality and detection performance of a direct digital radiography system].

The physical characteristics of a direct amorphous Selenium (a-Se) digital fluoroscopy and radiography system were investigated. Pre-sampled modulation transfer functions (MTF) were measured using a slit method. Noise power spectra were determined for different input exposures by fast Fourier transform of uniformly exposed samples. The MTFs of direct digital radiography systems showed significantly higher values than those of indirect digital radiography and screen-film systems. The direct digital radiography systems showed higher noise levels compared with those of indirect systems under roughly the same exposure conditions. Contrast-detail analysis was performed to compare detection by direct digital radiography systems with that of the screen-film (FUJI HG-M2/UR2) systems. The average contrast-detail curves of digital and film images were obtained from the results of observation. Image quality figures (IQF) were also calculated from the individual observer performance tests. The results indicated that digital contrast-detail curves and IQF are, on average, are equal those of the screen-film system.

Fourier Analysis↗

Physical imaging properties and low-contrast performance of a newly developed flat-panel digital radiographic system.

We investigated the clinical usefulness of a newly developed flat-panel detector (FPD) system by comparing its physical imaging properties and low-contrast detectability with those of a current FPD system. The newly developed CsI-based indirect FPD (Canon, CXDI-40C) and current Gd(2)O(2)S-based FPD (Canon CXDI-11) systems were used. Characteristic curves, resolution properties, radiographic noise, detective quantum efficiencies (DQEs) and low-contrast detectability for both systems were measured. The new FPD system showed considerably lower noise levels than those of the current FPD system. DQE (0) s of the new and current FPD systems were 75% and 35%, respectively. Observer performance tests of the contrast-detail (C-D) phantom indicated that the new FPD system can significantly improve low-contrast performance over that obtainable with the current FPD system under the same conditions of exposure. The new FPD system provided approximately 50% reduction in exposure while providing comparable detectability. The newly developed FPD system provides radiographic images with excellent inherent physical image quality and low-contrast performance.

Cesium↗

[Full-field digital mammography with amorphous silicon-based flat- panel detector: physical imaging characteristics and signal detection].

The physical characteristics of a clinical amorphous silicon-based flat-panel imager for full-field digital mammography were investigated. Pre-sampled modulation transfer functions (MTF) were measured by using a slit method. Noise power spectra were determined for different input exposures by fast Fourier transform. The MTFs of full-field digital mammography systems showed significantly higher values than those of the computed radiography (CR) system. The full-field digital mammography system showed a lower noise level than that of the CR system under the same exposure conditions. Contrast detail analysis has been performed to compare the detectability of the full-field digital mammography system with that of the screen-film (Min-R 2000/Min-R 2000) system. The average contrast-detail curves of digital and film images were obtained from the results of observation. Image quality figures (IQF) were also calculated from the individual observer performance tests. The results indicated that the digital contrast-detail curves and IQF, on average, are superior to those of the screen-film system.

Fourier Analysis↗

[Canon's flat-panel detector].

We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ) ) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm(-1), but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system were better than those of FCR system a little at lower spatial frequencies than 1.6 mm(-1), but the overall NEQ of FPD and FCR systems were worse than that of S/F system at all spatial frequencies. Comparison of chest phantom images showed that the FPD produced images with quality comparable to or higher than those of the FCR system. From these results, we can expect that the FPD is useful machine by using digital image processing and so on in the radiology department.

Image Processing, Computer-Assisted↗