PubMed Health⌕ Search

Biomedical subjects

Kazuhiko Ishihara

Publications and source records attributed to Kazuhiko Ishihara.

At least 19 recordsLinked to original sources

Temporal and spatially controllable cell encapsulation using a water-soluble phospholipid polymer with phenylboronic acid moiety.

Temporal and spatially controllable cell encapsulation based on a water-soluble phospholipid polymer is reported in this study. Phospholipid polymers, i.e., poly(2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate-co-p-vinylphenylboronic acid) (PMBV), were synthesized. A series of hydrogels was prepared between the water-soluble PMBV and other water-soluble polymers having multi-valent alcoholic groups, such as poly(vinyl alcohol) (PVA). The PMBV/PVA hydrogels were formed not only in water, but also in a cell culture medium, and dissociated by the excess addition of low molecular weight di-valent hydroxyl compounds, such as d-glucose. The PMBV/PVA hydrogel was applied as a cell-container which has three-dimensional matrices for the reversible encapsulation of living cells without any response in it. Uniform cell seeding can be achieved using the hydrogels due to the homogenous gel formation of PMBV and PVA in the cell culture medium. Fibroblast cells were encapsulated in the PMBV/PVA hydrogel and maintained for 1 week. After dissociation of the PMBV/PVA hydrogel, the cells were seeded on conventional tissue culture polystyrene. The cells adhered and proliferated as usual on the plate. That is, the PMBV/PVA hydrogel will be useful as a cell-container, which can maintain the cells without any significant adverse effect on the entrapped cells.

Animals↗

Development of gene vectors for pinpoint targeting to human hepatocytes by cationically modified polymer complexes.

We developed a vector that might enable gene therapy of metabolic liver disease or hepatoma. Here we demonstrate the use of cationically modified biocompatible phospholipid polymer conjugated with hepatitis B surface (HBs) antigen for the specific transfer of genes into human hepatocytes. Poly(2-methacryloyloxyethyl phosphorylcholine (MPC)- co-N,N-dimethylaminoethyl methacrylate (DMAEMA)-co- p-nitrophenylcarbonyloxyethyl methacrylate(NPMA))(polyMDN) was prepared as a frame of vector. The specific expression of sFlt-1 or GFP by polyMDN conjugated with HBs containing plasmid (plasmid/polyMDN-HBs), polyMDN containing plasmid (plasmid/polyMDN), plasmid only and PBS were assessed in tumor cells (HepG2 or WiDr) in vitro and in vivo. The histological findings, organ weight changes, and degree of liver dysfunction were examined in the mice administered by several reagents. The sFlt-1 and GFP expression was observed only in the HepG2 cells transfected with sFlt-1 or GFP/polyMDN-HBs. None of the side effects mentioned above was observed. In conclusion, these results suggest that polyMDN-HBs is a human hepatocyte-specific gene delivery vector that might not have serious side effects.

Adenocarcinoma↗

Biocompatibility and drug release behavior of spontaneously formed phospholipid polymer hydrogels.

Hydrogels containing 2-methacryloyloxyethyl phosphorylcholine (MPC) moieties were formed from aqueous solutions with water-soluble MPC polymers with carboxylic acid and alkyl groups because of hydrogen bonding formation. To investigate the biocompatibility and drug release behavior of the hydrogels, we used random- and block-type carboxylic acid MPC polymers, such as poly [MPC-co-methacrylic acid (MA)] (rPMA), poly[MPC-co-4-(2-methacryloyloxyethyl) trimellitic acid (MET)] (rPMT), poly (MA-block-MPC-block-MA) (bPMA) and poly(MET-block-MPC-block-MET) (bPMT), and alkyl MPC polymers, such as poly[MPC-co-n-butyl methacrylate] (PMB) and poly(MPC-co-benzyl methacrylate) (PMBz). We investigated the biocompatibility of the spontaneously formed MPC polymer hydrogels by a hemolysis test and an in vivo injection test. The random MPC polymers having carboxylic acid groups expressed more hemolytic activity compared to the block polymers. The results of the in vivo injection test also indicated low biocompatibility of the carboxylic acid polymers especially at high concentration. The alkyl MPC polymers, the PMB and PMBz showed excellent biocompatibility in both hemolysis and in vivo injection test. However, the hydrogels, the rPMA/PMB hydrogel (rABgel) and the rPMT/PMBz hydrogel (rTZgel) lowered the hemolytic activity of elemental polymers, the rPMA and rPMT. Thus, suppression of the ionization of the carboxylic acid groups is necessary for biocompatibility. We also investigated the drug release behavior with attention to the interaction between the polymer and the drugs. The release behavior of a relatively low-molecular-weight hydrophilic drug, 5-fluorouracil, did not depend on the structure of the polymers. The higher-molecular-weight drugs, ketoprofen and indomethacin, were released faster from the block polymer hydrogel than the random polymer hydrogel, the rABgel, while the highest-molecular-weight drug, doxorubicin, was released faster from the random polymer hydrogel. A probable reason for this is the difference in the molecular structure; that is, the separated hydrophilic and hydrophobic sections in the block polymers constructed pathways where a drug can diffuse. In addition, the rTZgel suppressed the release of a drug with a large number of aromatic rings probably because of the stacking effect. The results of the compression test also suggested the existence of the stacking effect between the rTZgel and the drugs. Based on these results, control of drug release is possible by selecting a reservoir with an appropriate chemical structure to interact with the drug. For example, release of a relatively linear-structured drug with less aromatic rings can be suppressed in the rABgel rather than in the rTZgel. Thus, it can be concluded that if the ionization is suppressed, these MPC polymer hydrogels can be used as a material for a drug reservoir that can be selected according to the drug.

Animals↗

Antibody immobilization to phospholipid polymer layer on gold substrate of quartz crystal microbalance immunosensor.

To modify gold electrode for immunosensor to construct an artificial cell membrane structure, water-soluble amphiphilic phospholipid polymer, poly[2-methacryloyloxyehtyl phosphorylcholine-co-n-butyl methacrylate-co-p-nitrophenyloxycarbonyl poly(ethylene glycol) methacrylate (PMBN)] was applied. The polymer had active ester groups for immobilization of biomolecules and it was converted partially to thiol groups for binding to gold substrates. The partially thiolated PMBN was adsorbed on a gold electrode of quartz crystal microbalance (QCM). Surface characterization of adsorbed PMBN layers was thoroughly investigated with reflectance anisotropy spectroscopy, ellipsometry spectroscopy, dynamic contact angle and X-ray photoelectron spectroscopy measurements. Among several PMBN, having different degree of thiolation, it was concluded that 21.5% thiolated PMBN layer had the most well-ordered phosphorylcholine groups in its outer surface. The proteins adsorption test revealed that the phosphorylcholine group on the outer side of PMBN layers, which was substituted their active ester groups by glycine, showed suppress the non-specific adsorption of proteins, such as bovine serum albumin and gamma-globulin. Also, through antigen-antibody binding evaluation, the anti-C-reactive protein antibody immobilized on the PMBN surface worked well and it was confirmed that denaturation of the antibody on the PMBN layers was hardly occurred in spite of 60 days storage at 4 degrees C. The antibody conjugated phospholipid polymer layer with well-ordered phosphorylcholine group could be outstanding functional membrane for biomedical diagnostic devices without non-specific binding and reduction of immunologic activity of immobilized antibody.

Antibodies↗

Stress response of adherent cells on a polymer blend surface composed of a segmented polyurethane and MPC copolymers.

To better understand the effect of 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymer in improving the biocompatibility of segmented polyurethane (SPU), the expression of heat shock protein (HSP) mRNA in HeLa S3 cells adhered on SPU blended with MPC copolymers was measured. Conventionally, MPC copolymers (PMEH) were synthesized by changing the feed ratios of MPC and 2-ethylhexyl methacrylate. X-ray photoelectron spectroscopic analysis of the SPU/PMEH film indicated that the surface concentration of MPC units on the SPU/PMEH film increased with an increase in PMEH composition. HeLa S3 cells were cultured on SPU/PMEH films. The number of adherent cells on the SPU/PMEH films decreased with an increase in the concentration of PMEH. When the PMEH composition was greater than 0.5 wt %, cell adhesion and proliferation decreased markedly. Expressions of HSP27 and HSP47 mRNA were detected using the reverse transcription-polymerase chain reaction (RT-PCR). After incubation for 24 h, both the HSP mRNA expressions in the HeLa S3 cells showed no significant differences among all samples. In HeLa S3 cells that adhered to the SPU film for 48 h, the expressions of HSP27 and HSP47 mRNA increased significantly when compared with those incubated for 24 h. In contrast, the two kinds of mRNA expressions decreased in the HeLa S3 cells that adhered to the SPU/PMEH films for 48 h. From these results, we concluded that PMEH was quite important in suppressing the stress response of adherent HeLa S3 cells. Therefore, SPU/PMEH blend polymers are useful as implantable biomedical materials.

Adsorption↗

Aldosterone synthesis and cytokine production in human peripheral blood mononuclear cells.

Previously, we reported that spironolactone reduced cytokine production in cultured human peripheral blood mononuclear cells (PBMCs) with angiotensin (Ang) II stimulation. To address the mechanisms underlying this effect, we examined the contribution of aldosterone to cytokine production in cultured human PBMCs with Ang II stimulation. PBMCs expressed the messenger RNA (mRNA) of Ang II type 1 receptor (AT1R) and mineralocorticoid receptor (MR) both spontaneously and after Ang II stimulation, but expressed Ang II type 2 receptor (AT2R) under neither condition. After 24 h of incubation, exogenous Ang II induced the expression of CYP11B2 (a key enzyme of aldosterone synthesis) mRNA and caused aldosterone synthesis. CV-11974 (an AT1R antagonist) reduced Ang II-induced aldosterone synthesis, whereas PD-123319 (an AT2R antagonist) had no effect. The concentration of aldosterone peaked earlier than those of monocyte chemoattractant protein-1 (MCP-1) and tumor necrosis factor-alpha (TNF-alpha). After 48 h of incubation (under the influence of synthesized aldosterone), CV-11974 and spironolactone significantly reduced the Ang II-enhanced production of MCP-1 and TNF-alpha, whereas PD-123319 also had no effect. In conclusion, Ang II induces aldosterone synthesis through AT1R and enhances cytokine production through an AT1R-dependent mechanism and, at least partly, through a MR-dependent mechanism in human PBMCs.

Adult↗

Surface modification on microfluidic devices with 2-methacryloyloxyethyl phosphorylcholine polymers for reducing unfavorable protein adsorption.

Surface modification of polymer materials for preparing microfluidic devices including poly(dimethyl siloxane) (PDMS) was investigated with phospholipids polymers such as poly(2-methacryloyloxylethyl phosphorylcholine(MPC)-co-n-butyl methacrylate) (PMB) and poly(MPC-co-2-ethylhexyl methacrylate-co-2-(N,N-dimethylamino)ethyl methacrylate) (PMED). The hydrophilicity of every surface on the polymer materials modified with these MPC polymers increased and the value of zeta-potential became close to zero. The protein adsorption on the polymer materials with and without the surface modification was evaluated using a protein mixture of human plasma fibrinogen and serum albumin. Amount of proteins adsorbed on these polymeric materials showed significant reduction by the surface modification with the MPC polymers compared to the uncoated surfaces ranging from 56 to 90%. Furthermore, we successfully prepared PDMS-based microchannel which was modified by simple coating with the PMB and PMED. The modified microchannel also revealed a significant reduction of adsorption of serum albumin. We conclude that the MPC polymers are useful for reducing unfavorable protein adsorption on microfluidic devices.

Adsorption↗

Photoinduced phospholipid polymer grafting on Parylene film: advanced lubrication and antibiofouling properties.

Poly(p-xylylene) (Parylene C) coatings have been applied in implantable electronic devices because of their electrical insulation and moisture barrier properties. To provide lubrication and an antibiofouling surface, a biomimetic phospholipid polymer--poly(2-methacryloyloxyethyl phosphorylcholine (MPC))--was grafted from the surface using UV irradiation with benzophenone as an initiator. The poly(MPC) grafting on the Parylene C films was confirmed by attenuated total reflection-Fourier transfer inflated irradiation, X-ray photoelectron spectroscopy and ellipsometry. These analyses indicated that the Parylene C films were completely covered by the poly(MPC)-graft layer with an average thickness of 140 nm under dry condition. The atomic force microscope (AFM) images revealed that the poly(MPC)-graft chains extended under wet condition. However, they formed globular structures under dry condition. Water contact angle measurements revealed a decreased receding angle of 29.5 degrees on the poly(MPC)-grafted surface with a high hysteresis of 41.4 degrees. These results indicate that the poly(MPC)-graft chains gain mobility in a wet environment. The average kinetic friction coefficient of the poly(MPC)-grafted surface in water was 0.018, which was 90% lower than that of the original surface. The in vitro single protein adsorption reduced by over 70% due to the poly(MPC) grafting. The hydrated poly(MPC)-graft chains are considered to provide lubrication and antibiofouling properties. The surface zeta potential measurement clarified the electroneutrality of the poly(MPC)-grafted surface. We concluded that the poly(MPC) grafting from the Parylene C layer significantly improved its surface properties and, subsequently, its biological properties.

Animals↗

Quartz crystal microbalance immunosensors for environmental monitoring.

This paper presents discussion of quartz crystal microbalance (QCM) immunosensors for environmental monitoring. Factors limiting the practical application of antibodies to analytical problems are also presented. Among several candidates for the QCM immunosensor device, selected QCM devices and oscillating circuits were tested thoroughly and developed to obtain highly stable and sensitive frequency signals. The biointerface of QCM immunosensor was designed and controlled to immobilize antibody on the QCM surface, to reduce non-specific binding and to suppress denaturation of immobilizing antibody by self-assembled monolayer technique and artificial phospholipid (2-methacryloyloxyethyl phosphorylcholine (MPC)) polymer. MPC polymer as a antibody-stabilizing reagent was added to reduce non-specific binding of the antigen solution and stabilize the immunologic activity of the antibody-immobilized QCM. In addition, it provides examples for detection and quantitation of environmental samples using QCM immunosensors. The analytical results for fly ash extracted samples of dioxins using the QCM immunosensor indicated a good relationship with GC/MS methods. The integrating protocols of the competitive immunoassay and signal-enhancing step are for detecting low molecular analytes with extremely low detection limits using an QCM immunosensor. Furthermore, its detect limitation was extended from 0.1 to 0.01 ng/ml by the signal-enhancing step when the anti-bisphenol-A antibody conjugated MPC polymeric nanoparticles was used. The QCM immunosensor method has demonstrated its effectiveness as an alternative screening method for environmental monitoring because these results were compared with results obtained through environmental monitoring methods such as ELISA and GC/MS.

Biosensing Techniques↗

Anti-inflammatory effect of spironolactone on human peripheral blood mononuclear cells.

We evaluated the effect of alacepril, CV-11974, and spironolactone on the production of monocyte chemoattractant protein-1 (MCP-1) and tumor necrosis factor-alpha (TNF-alpha) in cultured human peripheral blood mononuclear cells stimulated with angiotensin (Ang) II. Alacepril, CV-11974, and spironolactone significantly reduced the enhanced production of MCP-1 and TNF-alpha induced by exogenous Ang II. Specifically, 10 muM of spironolactone significantly reduced cytokine production, compared to the same dose of alacepril or CV-11974. These findings indicate that spironolactone may contribute to ameliorate the prognosis of patients with cardiovascular diseases by reducing Ang II-induced inflammation, although further exploration including determining the mechanisms would be required.

Adult↗

Biomimetic phosphorylcholine polymer grafting from polydimethylsiloxane surface using photo-induced polymerization.

The biomimetic synthetic phospholipid polymer containing a phosphorylcholine group, 2-methacryloyloxyethyl phosphorylcholine (MPC), has improved the surface property of biomaterials. Both hydrophilic and anti-biofouling surfaces were prepared on polydimethylsiloxane (PDMS) with MPC grafted by surface-initiated photo-induced radical polymerization. Benzophenone was used as the photoinitiator. The quantity of the adsorbed initiator on PDMS was determined by UV absorption and ellipsometry. The poly(MPC)-grafted PDMS surfaces were characterized by XPS, ATR-FTIR and static water contact angle (SCA) measurements. The SCA on PDMS decreased from 115 degrees to 25 degrees after the poly(MPC) grafting. The in vitro single protein adsorption on the poly(MPC)-grafted PDMS decreased 50-75% compared to the unmodified PDMS. The surface friction of the poly(MPC)-grafted PDMS was lower than the unmodified PDMS under wet conditions. The oxygen permeability of the poly(MPC)-grafted PDMS was as high as the unmodified PDMS. The tensile property of PDMS was maintained at about 90% of the ultimate stress and strain after the poly(MPC) grafting. The surface-modified PDMS is expected to be a novel medical elastomer which possesses an excellent surface hydrophilicity, anti-biofouling property, oxygen permeability and tensile property.

Biomimetic Materials↗

Dual mode bioreactions on polymer nanoparticles covered with phosphorylcholine group.

We investigated the preparation of polymer nanoparticles covered with phosphorylcholine (PC) groups and the immobilization of proteins in order to observe dual mode bioreactions on the nanoparticles. For the surface modification on the nanoparticles, a water-soluble amphiphilic phospholipid polymer with PC groups as a hydrophilic moiety was synthesized. In this polymer, an active ester group, which can immobilize proteins, was introduced. Using the phospholipid polymer as a solubilizer, poly(L-lactic acid) nanoparticles were prepared from its methylene chloride solution in an aqueous medium by the solvent evaporation method. The diameter of the nanoparticles was ca. 200 nm and the surface was covered with the PC groups and active ester groups. Proteins could immobilize on the nanoparticles under mild conditions by the reaction between the active ester group and amino group in the proteins. Both an antibody and enzyme were immobilized on the nanoparticles and bioreactions such as the antigen/antibody reaction and enzymatic reaction were observed. When an antigen was added to the suspension of the nanoparticles, aggregation of the nanoparticles occurred and then they precipitated. Also, the enzymatic reaction proceeded well when the enzyme substrate was added to the suspension. Based on these results, we provided polymer nanoparticles functionalized with both the antibody and enzyme, and the dual mode bioreactions could occur. We concluded that the novel polymer nanoparticles could be used for nano-/micro-scaled diagnostic and medical treatment systems.

Antibodies, Monoclonal↗

Asymmetrically functional surface properties on biocompatible phospholipid polymer membrane for bioartificial kidney.

To obtain a bioartificial kidney composed of a porous polymer membrane and renal cells, a polysulfone (PSf) membrane (PSM) blended with 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer was prepared. The PSM flat membrane with a porous structure could be prepared from the polymer blend containing 1 wt % of the MPC polymer in PSf by the phase inversion technique in a dry-wet process. Asymmetrical surface properties were observed on both sides of the membrane surfaces. That is, the sponge layer formed at the substrate-contacting surface of the membrane had 10-20 microm pores, but the pores in the micrometer range could not be observed for a skin layer formed at the air-contacting surface of the membrane. At the sponge layer surface, the MPC unit composition was 7 times larger than that at the skin layer surface. The amount of proteins adsorbed on the surface corresponded to the MPC unit composition. On the skin layer, a small amount of adsorbed proteins and platelet adhesion could be suppressed compared with those on the sponge layer. However, the skin layer had a moderate protein adsorption, so it showed a sufficient cytocompatibility to enable renal tubule epithelial cells to adhere and proliferate in the membrane. Thus, it functioned well as a renal tubule. Therefore, because of both its hemocompatibility and cytocompatibility, we could conclude that the PSM membrane is useful for as a renal tubule device for a bioartificial kidney.

Adsorption↗

Sequential enzymatic reactions and stability of biomolecules immobilized onto phospholipid polymer nanoparticles.

Polymer nanoparticles for sequential enzymatic reactions were prepared by combining a phospholipid polymer shell with a polystyrene core. The active ester groups for the bioconjugation and phospholipid polar groups were incorporated into the phospholipid polymer backbone using a novel active ester monomer and 2-methacryloyloxyethyl phosphorylcholine. For the sequential enzymatic reactions, acetylcholinesterase, choline oxidase, and horseradish peroxidase-labeled IgG were immobilized onto the nanoparticles. As substrates, acetylcholine chloride, choline chloride, and tetramethylbenzidine were added to the nanoparticle suspension, the acetylcholine chloride was converted to choline chloride, the choline chloride was oxidized by choline oxidase, and hydrogen peroxide was then formed as an enzymatic degradation product. The hydrogen peroxide was used for the next enzymatic reaction (oxidized by peroxidase) with tetramethylbenzidine. The sequential enzymatic reactions on the nanoparticles via degradation products (hydrogen peroxide) were significantly higher than that of the enzyme mixture. This result indicated that the diffusion pathway of the enzymatic products and the localization of the immobilized enzyme were important for these reactions. These nanoparticles were capable of facilitating sequential enzymatic reactions.

Acetylcholinesterase↗

2006 Frank Stinchfield Award: grafting of biocompatible polymer for longevity of artificial hip joints.

Aseptic loosening induced by wear particles from the polyethylene liner is likely the most common cause of long-term total hip arthroplasty failure. We developed a novel hip polyethylene liner with the surface graft of a biocompatible phospholipid polymer, 2-methacryloyloxyethyl phosphorylcholine (MPC), and previously reported the grafting decreased the short-term production of wear particles and the subsequent bone resorptive responses. For clinical application, we investigated the stability of the 2-methacryloyloxyethyl phosphorylcholine grafting during sterilization and the wear resistance of the sterilized liner during longer loading comparable to clinical usage. Radiographic spectroscopy confirmed the stability of the 2-methacryloyloxyethyl phosphorylcholine polymer on the liner surface after the gamma irradiation. We used a hip wear simulator up to 1 x 10(7) cycles to test sterilized cross-linked polyethylene liners with and without 2-methacryloyloxyethyl phosphorylcholine grafting. The 2-methacryloyloxyethyl phosphorylcholine grafting markedly decreased the friction, the production of wear particles, and the wear of the liner surface. These data suggest a marked improvement in the wear resistance of the polyethylene liner by the 2-methacryloyloxyethyl phosphorylcholine grafting for clinically relevant periods after sterilization, indicating 2-methacryloyloxyethyl phosphorylcholine grafting is a promising technology for extending longevity of artificial hips.

Gamma Rays↗

Biocompatible and biodegradable phosphorylcholine ionomers with reduced protein adsorption and cell adhesion.

In this paper a recently developed biodegradable phosphorylcholine ionomer (PC ionomer) was evaluated in different biological environments with a focus on the adsorption of proteins (fibrinogen) and the adhesion of cells. Our results have shown that the polar phosphoryl choline (PC) group may be enriched at the surface of cast films with an added hydrophilic environment. X-ray photoelectron spectroscopy confirmed the surface depletion of PC groups in dry conditions, as nitrogen and phosphorous atoms were found in the bulk of the material but not at the outermost surface layer. The surface enrichment leads to a strongly hydrophilic surface that prevents the adsorption of proteins and reduces the adhesion of cells. The non-functional and hydrophobic reference poly(trimethylene carbonate) (PTMC) adsorbs both proteins and cells, thus the wetting and low adhesion behavior of the PC ionomer can be attributed to the introduced PC functionality. Since the in vivo acceptance of biomaterials is determined by their ability to withstand protein adsorption the PC ionomer described in this paper is highly interesting for a number of in vivo applications in which the adsorption of proteins may be critical, for example, blood contact events.

Adsorption↗

Soft contact lens biomaterials from bioinspired phospholipid polymers.

Soft contact lens (SCL) biomaterials originated from the discovery of a poly(2-hydroxyethyl methacrylate) (poly[HEMA])-based hydrogel in 1960. Incorporation of hydrophilic polymers into poly(HEMA) hydrogels was performed in the 1970-1980s, which brought an increase in the equilibrium water content, leading to an enhancement of the oxygen permeability. Nowadays, the poly(HEMA)-based hydrogels have been applied in disposable SCL. At the same time, high oxygen-permeable silicone hydrogels were produced, which made it possible to continually wear SCL. Recently, numerous trials for improving the water wettability of silicone hydrogels have been performed. However, little attention has been paid to improving their anti-biofouling properties and biocompatibility. Since biomimetic phospholipid polymers possess excellent anti-biofouling properties and biocompatibility they have the potential to play a valuable role in the surface modification of the silicone hydrogel. The representative phospholipid polymers containing a 2-methacryloyloxyethyl phosphorylcholine (MPC) unit suppressed nonspecific protein adsorption, increased cell compatibility and contributed to blood compatible biomaterials. The MPC polymer coating on the silicone hydrogel improved its water wettability and biocompatibility, while maintaining high oxygen permeability compared with the original silicone hydrogel. Furthermore, the newly prepared phospholipid-type intermolecular crosslinker made it possible to synthesize a 100% phospholipid polymer hydrogel that can enhance the anti-biofouling properties and biocompatibility. In this review, the authors discuss how polymer hydrogels should be designed in order to obtain a biocompatible SCL and future perspectives.

Biocompatible Materials↗

Nitric oxide synthase activity in rat gastric mucosa contributes to mucin synthesis elicited by calcitonin gene-related peptide.

The majority of research for the calcitonin gene-related peptide (CGRP) in the stomach has been devoted to the submucosal blood flow, and only slight attention has been paid to its involvement in the gastric epithelial function. In this study, we examined the age-related change in the CGRP-containing nerves and its effects on the mucus metabolism. We compared the immunoreactivity for CGRP in the gastric mucosa of 7-week-old rats (young) to that of 52-week-old animals (middle-aged). The effects of CGRP on the mucin biosynthesis were compared using the stomachs from both young and middle-aged rats. The nitric oxide synthase (NOS) activity was measured in the surface and deep mucosa of the gastric corpus. The density of the CGRP nerve fibers was reduced in both the lamina propria and submucosa of the middle-aged rats compared to the young rats. CGRP stimulated the mucin biosynthesis in the cultured corpus mucosa from the 7-week-old rats, but not from the 52-week-old rats. The total NOS activity of the surface layer in the corpus mucosa was markedly reduced in the middle-aged rats compared to the young rats. These findings demonstrate the age-dependent reduction in the CGRP-induced mucin biosynthesis, as well as in the density of the CGRP fibers in the rat stomach. The decreased NOS activity in the surface layer of the oxyntic mucosa in the aged rats may also be a principal cause for the lack of regulation of the mucin biosynthesis by CGRP.

Animals↗