PubMed Health⌕ Search

Biomedical subjects

Kazuhiko Oka

Publications and source records attributed to Kazuhiko Oka.

4 recordsLinked to original sources

Modeling and optimization for a prismatic snapshot imaging polarimeter.

Thin birefringent prisms placed near an image plane introduce sinusoidal fringes onto a 2D polarized scene making possible a snapshot imaging polarimeter, which encodes polarization information into the modulation of the fringes. This approach was introduced by Oka and Kaneko [Opt. Express 11, 1510 (2003)], who analyzed the instrument through the Mueller calculus. We show that the plane-wave assumption adopted in the Mueller theory can introduce unnecessary error in a polarimeter design. To directly take prism effects such as beam splitting and deviating into accounts we introduce a geometric imaging model, which allows for a versatile simulation of the birefringent prisms and provides a means for optimization. A calcite visible system is investigated as an example, which essentially shows how each design parameter affects the overall image quality and how to modify the polarimeter design to optimize overall performance. The approach is applicable to any prismatic imaging polarimeter with different prism materials and different working wavelengths.

Journal Article↗

Stabilization of a channeled spectropolarimeter by self-calibration.

A novel method to stabilize a channeled spectropolarimeter is described. The fluctuating retardations of the high-order retarders used in the spectropolarimeter are calibrated in parallel to the measurement of the wavenumber-dependent state of polarization (SOP) of light. Both the calibration of the retarders and the measurement of the SOP can be made simultaneously using a single light to be measured, and hence the resultant wavenumber-dependent SOP is almost immune to fluctuation of the retardations. The effectiveness of this method is experimentally demonstrated with retardation fluctuations induced by a temperature change up to 40 degrees C.

Journal Article↗

Optical pulse compression to 3.4 fs in the monocycle region by feedback phase compensation.

We compensated for chirp of optical pulses with an over-one-octave bandwidth (495-1090 nm; center wavelength of 655.4 nm) produced by self-phase modulation in a single argon-filled hollow fiber and generated 3.4-fs, 1.56 optical-cycle pulses (500 nJ, 1-kHz repetition rate). This was achieved with a feedback system combined with only one 4-f phase compensator with a spatial light modulator and a significantly improved phase characterizer based on modified spectral phase interferometry for direct electric-field reconstruction. To the best of our knowledge, this is the shortest pulse in the visible-to-infrared region.

Journal Article↗

Birefringent imaging spectrometer.

A Fourier-transform imaging spectrometer, believed to be novel, based on the Savart polariscope is presented. There is no slit in this instrument, which means that it has a high throughput. The principle and the system configuration are described. Several preliminary experimental results are shown.

Journal Article↗