PubMed Health⌕ Search

Biomedical subjects

Kazuhiko Tanaka

Publications and source records attributed to Kazuhiko Tanaka.

At least 19 recordsLinked to original sources

Influence of acidic eluent for retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography on a weakly acidic cation-exchange resin in the H+ -form.

Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.

Anions↗

Mechanisms of wave fractionation at boundaries of high-frequency excitation in the posterior left atrium of the isolated sheep heart during atrial fibrillation.

BACKGROUND: High-frequency fractionated electrograms recorded during atrial fibrillation (AF) in the posterior left atrium (PLA) and elsewhere are being used as target sites for catheter ablation. We tested the hypothesis that highly periodic electric waves emerging from AF sources at or near the PLA give rise to the most fractionated activity in adjacent locations. METHODS AND RESULTS: Sustained AF was induced in 8 isolated sheep hearts (0.5 micromol/L acetylcholine). Endocardial videoimaging (DI-4-ANEPPS) and electric mapping of the PLA enabled spatial characterization of dominant frequencies (DFs) and a regularity index (ratio of DF to total power). Regularity index showed that fractionation was lowest within the area with the maximal DF (DFmax domain; 0.19+/-0.02) and highest within a band of &3 mm (0.16+/-0.02; P=0.047) at boundaries with lower-frequency domains. The numbers of spatiotemporal periodic episodes (25.9+/-2.3) and rotors per experiment (1.9+/-0.7) were also highest within the DFmax domain. Most commonly, breakthrough waves at the PLA traveled toward the rest of the atria (76.8+/-8.1% outward versus 23.2+/-8.1% inward; P<0.01). In both experiments and simulations with an atrial ionic model, fractionation at DFmax boundaries was associated with increased beat-to-beat variability of conduction velocity and directionality with wavebreak formation. CONCLUSIONS: During stable AF, the PLA harbors regular, fast, and highly organized activity; the outer limit of the DFmax domain is the area where the most propagation pattern variability and fractionated activity occur. These new concepts introduce a new perspective in the clinical use of high-frequency fractionated electrograms to localize sources of AF precisely at the PLA and elsewhere.

Animals↗

Vacancy ion-exclusion chromatography of inorganic acids on a weakly acidic cation-exchange resin column.

Vacancy ion-exclusion chromatography (VIEC) for inorganic acids such as H(2)SO(4), HCl, H(3)PO(4), HNO(3), HI and HF is tested on a polymethacrylate-based weakly acidic cation-exchange resin column in the H(+)-form. That is, mixture of inorganic acids in the mobile phase is adsorbed to the resin phase passing through the separation column, and each vacant peak induced by injecting water is determined. Retention times are dependent on the degrees of retention for each analyte in the resin phase. In VIEC, well-shaped peaks of inorganic acids are produced, leading to efficient separations. However, retention behaviors of inorganic acids were strongly affected by the concentrations of the acids in the mobile phase. Sulfosalicylic acid was mixed with inorganic acids in the mobile phase prior to the introduction of a separation column in order to obtain the well-resolutions in the lower concentrations of the acids. By using this method, the separations of inorganic acids could be achieved in the range of 0.01-1 mM, and the linear ranges could be extended over two-orders of magnitude. This is considered since the protonated carboxylic groups fixed on the resin phase were increased with increasing the acid concentrations in the mobile phase, and the penetration effects for the acids to the resin phase were thus enhanced. The detection limits (S/N=3) were below 1.0 microM for all analyte acids. Precision values for retention times were below 0.32% and for peak area were below 0.91%.

Acids↗

Correlation between plasma glucagon-like peptide 2 levels and proliferative makers in small intestinal injury in rats induced by methotrexate administration.

Glucagon-like peptide 2 (GLP-2) is a potent intestinal epithelium-specific growth factor that has been shown to reduce the severity of inflammatory disorders of the intestine in rodent models. We examined whether a relationship exists between plasma level of GLP-2 and the degree of intestinal injury induced by chemotherapeutic agents in the rat. Methotrexate (MTX) was administrated orally for 6 consecutive days at doses of 1.25, 2.5, and 5.0 mg/kg body weight per day. Mucosal samples of rat duodenum, jejunum, and ileum were used for assessment of mucosal weight, DNA and protein content. Plasma GLP-2 levels were measured on day 8. MTX significantly reduced body weight. The values of all indices tended to decrease in all segments with increases in MTX dose. Plasma GLP-2 levels were significantly higher in the MTX 2.5 mg/kg/d group (p<0.05) and the MTX 5.0 mg/kg/d group (p<0.01) than in the control group. Correlations were found between plasma GLP-2 levels and mucosal weight, DNA and protein content. We concluded that plasma GLP-2 levels reflect the degree of intestinal injury following MTX administration in this preclinical model.

Administration, Oral↗

Selective and simultaneous determination of phosphate and silicate ions in leaching process waters for ceramics glaze raw materials of narutal origin by ion-exclusion chromatography coupled with UV-detection after postcolumn derivatization.

The selective and simultaneous ion-exclusion chromatography (IEC) with UV-detection on a weakly acidic cation-exchange resin column in the H+ -form (TSKgel Super IC-A/C) was developed and applied for the simultaneous determination of phosphate and silicate ions as the water quality parameters required for optimizing the water-leaching process for ceramics glaze raw materials of natural origin including feldspar, woods-ash, and straw-ash. Phosphate and silicate ions in these water-leaching process water samples were separated selectively from the coexisting anions such as sulfate, chloride, nitrate and carbonate ions, based on the ion-exclusion separation mechanism. They were detected selectively and simultaneously by a postcolumn derivatization with molybdenum-yellow using the UV-detector. Under the optimized separation and detection conditions (eluent, 0-1 mM sulfuric acid; reactant, 10 mM sodium molybdate-25 mM sulfuric acid; detector, UV at 370 nm; temperature, 45 degrees C), the linearity of calibration was in the range 0.1 - 10 ppm for both phosphate and silicate ions, and the detection limits at S/N = 3 were 2.58 ppb for silicate ions and 4.75 ppb for phosphate ions. The effectiveness of this method was demonstrated in practical applications to the water-leaching process for some ceramics glaze raw materials.

Aluminum Silicates↗

Effect of amiodarone on the serum concentration/dose ratio of metoprolol in patients with cardiac arrhythmia.

Amiodarone has pharmacokinetic interactions with a number of therapeutic drugs, including warfarin, phenytoin, flecainide, and cyclosporine. Metoprolol is mainly metabolized by CYP2D6, and desethylamiodarone, a metabolite of amiodarone, has a markedly greater inhibitory effect on CYP2D6 than amiodarone. Therefore, the goal of this study was to evaluate the effect of amiodarone and desethylamiodarone on the serum concentration/dose ratio (C/D) of metoprolol in 120 inpatients with cardiac arrhythmias that received either metoprolol and amiodarone (MET+AMD group, n=30) or metoprolol alone (MET group, n=90). The ratio of administered metoprolol was compared between the MET and the MET+AMD groups. The dose of metoprolol and patient age were significantly higher in the MET group when compared with the MET+AMD group (1.00+/-0.480 versus 0.767+/-0.418 mg/kg/day, p<0.050; 68.6+/-10.6 versus 57.6+/-14.1 years, p<0.001, respectively), but the C/D ratio was significantly lower in the MET group than in the MET+AMD group (90.8+/-64.0 versus 136+/-97.8, p<0.01). Furthermore, a significant correlation was found between the C/D ratio and desethylamiodarone concentration (n=30, r=0.371, p<0.01). The results suggest that there is a significant interaction between amiodarone and metoprolol via desethylamiodarone-induced inhibition of CYP2D6. Therefore, careful monitoring of metoprolol concentrations/bioactivity of CYP2D6 is required in the context of co-administration of amiodarone and metoprolol.

Adult↗

High-speed ion-exclusion chromatography of dissolved carbon dioxide on a small weakly acidic cation-exchange resin column with ion-exchange enhancement columns of conductivity detection.

The high-speed ion-exclusion chromatographic determination of dissolved carbon dioxide, i.e., carbonic acid, hydrogencarbonate or carbonate, with conductivity detection was obtained using a small column packed with a weakly acidic cation-exchange resin in the H+-form (40 mm long x 4.6 mm i.d., 3 microm-particle and 0.1 meq./ml-capacity). Two different ion-exchange resin columns, which were a strongly acidic cation-exchange resin in the K+-form and a strongly basic anion-exchange resin in the OH- -form, were connected after the separation column. The sequence of columns could convert dissolved carbon dioxide to KOH having high conductivity response. The enhancement effect for dissolved carbon dioxide could retain even on the vast chromatographic runs, by using the enhancement columns with high ion-exchange capacity above 1.0 meq./ml. The retention time was in 60 s at flow-rate of 1.2 ml/min. The calibration graph of dissolved carbon dioxide estimated as H2CO3- was linear in the range of 0.005-10 mM. The detection limit at signal to noise of 3 was 0.15 microM as H2CO3-. This method was applicable to several rainwater and tap water samples.

Carbon Dioxide↗

Prediction of efficacy of interferon treatment of chronic hepatitis C and occurrence of HCC after interferon treatment by a new classification.

One hundred and twenty-one chronic hepatitis C patients were administered interferon (IFN) and divided into two groups: 31 complete responders (CR) with prolonged HCV-RNA negative 1 year after treatment and 90 non-complete responders (non-CR), including partial responders (PR) with transiently negative HCV-RNA and non-responders (NR) with continuously positive HCV-RNA. Liver biopsy specimens were classified into four grades and stages according to the degree of severity and the extent of fibrosis, respectively. No correlation was observed between the rate of IFN efficacy and grading. By staging, however, a difference in the efficacy of IFN was observed between F1 or F2 and F3 (0.05 < p < 0.1 and 0.01 < p < 0.025, respectively). Of the CR, 0% (0/5) were at F0 and 27.9% (24/86) at F1, 42.9% (6/14) at F2, and 6.3% (1/16) at F3. Another group of 118 chronic hepatitis patients (31 CR, 41 PR and 46 NR) followed up for over 2 years after IFN treatment were analyzed. By staging, 7 cases were at F0, 76 at F1, 18 at F2, and 17 at F3. HCC occurred in 1 of the 31 CR cases (representing an annual incidence rate of 1.21%), in 4 of the 41 PR cases (4.08%), and in 4 of the 46 NR cases (3.55%). HCC did not occur in any of the 7 cases at F0 (representing an annual incidence rate of 0%); it occurred in 2 of the 76 cases at F1 (1.01%), in 1 of the 18 cases at F2 (2.28%), and in 6 of the 17 cases at F3 (16.57%). These results suggest that the new classification would be conducive to roughly predicting the efficacy of IFN treatment and the occurrence of HCC after IFN treatment.

Adult↗

Protective effects of capsaicin against cisplatin-induced nephrotoxicity in rats.

Cisplatin-induced nephrotoxicity is related to an increase in lipid peroxidation and oxygen free radicals in a kidney. In the present study, we investigated the effect of the dietary antioxidants, capsaicin (Cap), against cisplatin-induced lipid peroxidation and nephrotoxicity in rats. Nephrotoxicity induced by treatment with a single dose of cisplatin (5 mg/kg body weight i.p.). The animals were divided into 4 groups. Cap (10 mg/kg/d) was given by gavage from the same day of cisplatin injection. Cisplatin administration resulted in significant increases in the kidney weight as a percentage of the total body weight, urine volume, serum creatinine, and blood urea nitrogen by about 132, 315, 797, and 556% in comparison with the control rats, respectively (p < 0.05). Also, the renal tissue from the cisplatin-treated rats showed significant decreases in the kidney glutathione (GSH) content and superoxide dismustase (SOD) activity and a significant increase in malondialdehyde (MDA) production in comparison to the values at 0 h (p < 0.05). Seven days after Cap plus cisplatin treatments, the renal damage induced by cisplatin recovered to a significant statistically level. In addition, Cap prevented the rise of MDA and the reduction of SOD activities. These results suggest that Cap has protective effects against cisplatin-induced nephrotoxicity and lipid peroxidation in rats.

Animals↗

Analysis of carbonic acid in water samples by ion-exclusion chromatography with pure water as eluent.

A simple, sensitive and rapid ion-exclusion chromatographic method for the simultaneous separation of carbonic acid and short chain organic acids (formic acid, acetic acid, and propionic acid) has been developed. A weakly acidic cation exchange resin column TSKgel OApak-A was used for the separation; pure water, owing to its lower background conductance, was employed as eluent in order to obtain high detection sensitivity. A good separation of these weak acids was achieved in 16 min. The linear range of the peak area calibration curve for carbonic acid was from 3.0 mg/L to 500 mg/L. The conductivity detection limit calculated at S/N = 3 was 0.084 mg/L for carbonic acid. The method developed in this work was successfully applied to the determination of carbonic acid in several environmental water samples without any pretreatment.

Journal Article↗

Caged multiwalled carbon nanotubes as the adsorbents for affinity-based elimination of ionic dyes.

Multiwalled carbon nanotubes (MWCNTs) were used as the active elements for the first time for affinity-based elimination of ionic dyes. MWCNTs were encapsulated in cross-linked alginate (ALG) microvesicles using Ba2+ as the bridging ion. The Ba2+-alginate matrix constitutes a cage which holds the physically trapped MWCNTs. The cage carries negative charges on its surface. The cage restricts the access of anions of large molecular weight, such as humic acids, because of electrostatic repulsion. The cage also restricts the access of colloids of large size, because of size exclusion. Ionic dyes partition into the cage and then are captured by MWCNTs probably on the basis of van der Waals interactions occurring between the hexagonally arrayed carbon atoms in the graphite sheet of MWCNTs and the aromatic backbones of the dyes. As a result of these interactions the target species, namely, the ionic dyes, are eliminated efficiently by the MWCNTs of Ba2+-ALG/MWCNT composite adsorbents. The adsorptive capacities for elimination of acridine orange, ethidium bromide, eosin bluish, and orange G (the model species used for this study) were found as high as 0.44, 0.43, 0.33, and 0.31 micromol, respectively, for 1.0 mg of the caged MWCNTs. Adsorptive experiments with carbon nanofibers and activated carbons as the adsorbents were also performed. The MWCNT-based adsorbents provided the best capability for the affinity-based elimination of these targeted species. Biocompatibility experiments performed in vitro and in vivo provided promising results, suggesting potential applications of the caged MWCNTs in in situ environmental remediation.

Adsorption↗

Ion chromatographic determination of hydroxide ion on monolithic reversed-phase silica gel columns coated with nonionic and cationic surfactants.

The determination of hydroxide by ion chromatography (IC) is demonstrated using a monolithic octadecylsilyl (ODS)-silica gel column coated first with a nonionic surfactant (polyoxyethylene (POE)) and then with a cationic surfactant (cetyltrimethylammonium bromide (CTAB)). This stationary phase, when used in conjunction with a 10 mmol/l sodium sulfate eluent at pH 8.2, was found to be suitable for the rapid and efficient separation of hydroxide from some other anions, based on a conventional ion-exchange mechanism. The peak directions and detection responses for these ions were in agreement with their known limiting equivalent ionic conductance values. Under these conditions, a linear calibration plot was obtained for hydroxide ion over the range 16 micromol/l to 15 mmol/l, and the detection limit determined at a signal-to-noise ratio of 3 was 6.4 micromol/l. The double-coated stationary phase described above was shown to be superior to a single coating of cetyltrimethylammonium bromide alone, in terms of separation efficiency and stability of the stationary phase. A range of samples comprising solutions of some strong and weak bases was analyzed by the proposed method and the results obtained were in good agreement with those obtained by conventional potentiometric pH measurement.

Chromatography, Ion Exchange↗

Determination of some aliphatic carboxylic acids in anaerobic digestion process waters by ion-exclusion chromatography with conductimetric detection on a weakly acidic cation-exchange resin column.

The determination of seven aliphatic carboxylic acids, formic, acetic, propionic, isobutyric, n-butyric, isovaleric and n-valeric acids in anaerobic digestion process waters was examined using ion-exclusion chromatography with conductimetric detection. The analysis of these biologically important carboxylic acids is necessary as a measure for evaluating and controlling the process. The ion-exclusion chromatography system employed consisted of polymethacrylate-based weakly acidic cation-exchange resin columns (TSKgel OApak-A or TSKgel Super IC-A/C). weakly acidic eluent (benzoic acid), and conductimetric detection. Particle size and cation-exchange capacity were 5 microm and 0.1 meq./ml for TSKgel OApak-A and 3 microm and 0.2 meq./ml for TSKgel Super IC-A/C, respectively. A dilute eluent (1.0-2.0 mM) of benzoic acid was effective for the high resolution and highly conductimetric detection of the carboxylic acids. The good separation of isobutyric and n-butyric acids was performed using the TSKgel Super IC-A/C column (150 mm x 6.0 mm i.d. x 2). The simple and good chromatograms were obtained by the optimized ion-exclusion chromatography conditions for real samples from mesophilic anaerobic digestors, thus the aliphatic carboxylic acids were successfully determined without any interferences.

Acids↗

Determination of monovalent inorganic anions in high-ionic-strength samples by electrostatic ion chromatography with suppressed conductometric detection.

A new ion chromatographic (IC) system has been established by using micelles of 3-(N,N-dimethylmyristylammonio)propanesulfonate (Zwittergent 3-14) loaded onto a reversed-phase packed column as the separation column with an electronic rotary switching valve packed-bed suppressor for conductometric detection of inorganic anions. An aqueous H3BO3-Na2B4O7 solution has been demonstrated to be the most desirable eluent for this IC system. The relationship between retention time and the concentration of the borate eluent was determined for a series of model anionic analytes and this relationship was found to be opposite to that exhibited in a conventional anion-exchange IC system. The rapid elution and complete separation of monovalent inorganic anions were obtained by initially using a high-concentration borate solution as the eluent for a short-period, and then switching to a lower-concentration borate eluent to complete the separation. Detection limits for nitrite, bromide, nitrate, and chlorate were 0.85, 0.88, 0.95 and 4.8 microM, respectively, when a 7.0 mM Na2B4O7 eluent was used. Moreover, the ability to directly detect these monovalent anions in samples containing high concentrations of sulfate and/or chloride ions provided a major advantage of this approach.

Anions↗

Vacancy ion-exclusion/adsorption chromatography of aliphatic amines on a polymethacrylate-based weakly basic anion-exchange column.

Vacancy ion-exclusion/adsorption chromatography has been applied to investigate the separation behavior of five aliphatic amines (ethylamine, propylamine, butylamine, pentylamine and hexylamine) on a polymethacrylate-based weakly basic anion-exchange column (Tosoh TSKgel DEAE-5PW). This system is consisted of analytes as a mobile phase and water as an injected sample. In the vacancy ion-exclusion/adsorption chromatography, the elution order was as follows: ethylamine < propylamine < butylamine < pentylamine < hexylamine, depending on their hydrophobicity. The retention times of the amines were decreased with decreasing their concentrations in the mobile phase. The retention times and resolutions of the amines were increased by adding a basic compound (e.g., lithium hydroxide or heptylamine) and by increasing the pH of mobile phase (pH > 11). This was because the dissociations of amine samples in the mobile phase were suppressed and thus the hydrophobic adsorption effects were enhanced. The linearity of calibration graphs could be obtained from the peak areas of the amine samples injected to the 0.05, 0.5 and 5 mM of amine mobile phase at pH 11 by heptylamine. The detection limits of aliphatic amines as injected samples were around 1 microM for five aliphatic amines at three different amine mobile phases. From these results, the retention behaviors of aliphatic amines on vacancy ion-exclusion/adsorption chromatography were concluded to be governed by the hydrophobic adsorption effect.

Adsorption↗

Highly sensitive determination of hydrazine ion by ion-exclusion chromatography with ion-exchange enhancement of conductivity detection.

An ion-exclusion chromatography method with ion-exchange enhancement of conductivity was developed for the selective separation and sensitive determination of hydrazine ion from alkali/alkaline earth metal cations and ammonium ion. Hydrazine ion was separated by ion-exclusion/penetration effect from other cations on a weakly basic anion-exchange column in the OH- form (TSKgel DEAE-5PW). Moreover, two different ion-exchange resin columns were inserted between the separating column and conductimetric detector in order to improve the sensitivity of hydrazine ion. The first enhancement column packed with a strongly basic anion-exchange resin in the SO4(2-) form (TSKgel SAX) for hydrazine ion can convert from N2H5OH to (N2H5)2SO4. Moreover, the second enhancement column packed with a strongly acidic cation-change resin in the H+ form (TSKgel SCX) can convert to H2SO4. As a result, the sensitivity of hydrazine ion using two conductivity enhancement columns could be 26.8-times greater than using the separating column alone. This method was effectiveness also for the enhancement of ammonium ion (6.1-times) and sodium ion (1.2-times). The calibration graph of hydrazine ion detected as H2SO4 was linear over the concentration range of 0.001-100 ppm (r2 = 0.9988). The detection limit of hydrazine ion in this system was 0.64 ppb. Therefore, hydrazine ion in real boiler water sample could be accurately determined, avoiding the interference of other cations.

Calibration↗

(P)-helicene displays chiral selection in binding to Z-DNA.

Enantiomeric helicenes of (P)-A and (M)-A were synthesized. The binding of the helicenes to B- and Z-DNA was studied quantitatively by CD, equilibrium dialysis, and fluorescence spectroscopy. Enantiomeric (P)-A not only bound selectively to Z-DNA but also effectively converted the B-DNA conformation to Z-DNA. The enantioselectivity of the helicenes offers a new route for the rational design of inhibitors of biological functions that may depend on Z-DNA.

Base Sequence↗