PubMed Health⌕ Search

Biomedical subjects

Kazuhiro Homma

Publications and source records attributed to Kazuhiro Homma.

4 recordsLinked to original sources

In vivo isotropic 3D diffusion tensor mapping of the rat brain using diffusion-weighted 3D MP-RAGE MRI.

The purpose of this study was to examine the potential of diffusion-weighted (DW) three-dimensional (3D) MP-RAGE MRI for diffusion-tensor mapping of the rat brain in vivo. A DW-3D-MP-RAGE (3D-DWI) sequence was implemented at 2.0 T using six gradient orientations and a b value of 1000 s/mm2. In this sequence, the preparation sequence with a "90 degrees RF-motion proving gradient (MPG): MPG-180 degrees RF-MPG-90 degrees RF" pulse train (DW driven equilibrium Fourier transform) was used to sensitize the magnetization to diffusion. A centric k-space acquisition order was necessary to minimize saturation effects (T1 contamination) from tissues with short relaxation time. The image matrix was 128x128x128 (interpolated from 64x64x64 acquisitions), which resulted in small isotropic DW image data (voxel size: 0.273x0.273x0.273 mm3). Moreover, 3D-DWI-derived maps of the fractional anisotropy (FA), relative anisotropy (RA) and main-diffusion direction were completely free of susceptibility-induced signal losses and geometric distortions. Two well-known commissural fibers, the corpus callosum and anterior commissure, were indicated and shown to be in agreement with the locations of these known stereotaxic atlases. The experiment took 45 min, and shorter times should be possible in clinical application. The 3D-DWI sequence allows for in vivo 3D diffusion-tensor mapping of the rat brain without motion artifacts and susceptibility to distortion.

Animals↗

Time-resolved diffuse optical tomographic imaging for the provision of both anatomical and functional information about biological tissue.

We present in vivo images of near-infrared (NIR) diffuse optical tomography (DOT) of human lower legs and forearm to validate the dual functions of a time-resolved (TR) NIR DOT in clinical diagnosis, i.e., to provide anatomical and functional information simultaneously. The NIR DOT system is composed of time-correlated single-photon-counting channels, and the image reconstruction algorithm is based on the modified generalized pulsed spectral technique, which effectively incorporates the TR data with reasonable computation time. The reconstructed scattering images of both the lower legs and the forearm revealed their anatomies, in which the bones were clearly distinguished from the muscles. In the absorption images, some of the blood vessels were observable. In the functional imaging, a subject was requested to do handgripping exercise to stimulate physiological changes in the forearm tissue. The images of oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentration changes in the forearm were obtained from the differential images of the absorption at three wavelengths between the exercise and the rest states, which were reconstructed with a differential imaging scheme. These images showed increases in both blood volume and oxyhemoglobin concentration in the arteries and simultaneously showed hypoxia in the corresponding muscles. All the results have demonstrated the capability of TR NIR DOT by reconstruction of the absolute images of the scattering and the absorption with a high spatial resolution that finally provided both the anatomical and functional information inside bulky biological tissues.

Algorithms↗

Diffusion-weighted three-dimensional MP-RAGE MR imaging.

The advantages of three-dimensional (3D) acquisition are that you obtain thinner and more slices with better profiles, and better signal-to-noise ratio for an equivalent slice thickness. Three-dimensional acquisition is preferable for obtaining contiguous thin-slice MR images. However, the acquisition time extends compared with the two-dimensional acquisition because the second phase-encode axis is applied by the 3D acquisition. Therefore, 3D acquisition should be a high-speed imaging method. In this paper, a new diffusion-sensitive 3D magnetization-prepared rapid gradient-echo (3D MP-RAGE) sequence was studied. In this sequence, a preparation phase with a 90 degrees RF-motion proving gradient (MPG): MPG-180 degrees RF-MPG-90 degrees RF pulse train (diffusion-weighted driven-equilibrium Fourier transform) was used to sensitize the magnetization to diffusion. Centric k-space acquisition order is necessary to minimize saturation effects from tissues with short relaxation times. From phantom experimental results, the effect of the diffusion weighting was changed by the centric vs. sequential k-space acquisition order. The effect of centric k-space acquisition order was larger than the effect of sequential k-space acquisition order. The contrast of centric k-space acquisition order became equal to the contrast of conventional diffusion-weighted spin echo. From rat experimental results, small isotropic diffusion-weighted image data (voxel size: 0.625 x 0.625 x 0.625 mm3) were obtained. This sequence was useful in vivo.

Acetone↗

Stable nitroxide Tempol ameliorates brain injury by inhibiting lipid peroxidation in a rat model of transient focal cerebral ischemia.

Oxygen free radicals have been implicated in the pathogenesis of cerebral ischemia and reperfusion injury. 4-Hydroxy-2,2,6,6-tetramethylpiperidene-1-oxyl (Tempol) has been reported as a stable nitroxide and a membrane-permeable free radical scavenger. This study was performed to investigate the mechanism of Tempol in attenuating ischemia-reperfusion injury in a rat model of transient focal cerebral ischemia. We measured the cerebral 2,3-dihydroxybenzoic acid (DHBA) level as the amount of hydroxyl radical production using a microdialysis technique with salicylic acids trapping during ischemia and reperfusion. The concentration of cerebral thiobarbituric acid reactive substances (TBARS), representing the extent of lipid peroxidation by free radicals, and the area of cerebral infarction were also measured. The level of cerebral 2,3-DHBA was increased during ischemia and reperfusion, especially during the early reperfusion stage at the periphery of the infarct area (nearly 500-fold). Intravenous administration of Tempol at the time of reperfusion reduced 2,3-DHBA production (Vehicle group: 472.2+/-196.2, Tempol group: 238.3+/-77.2) and the cerebral TBARS level (Vehicle group: 541.7+/-84.7, Tempol group: 339.0+/-147.2 nmol/g), and decreased the size of the cerebral infarction (Vehicle group: 202.2+/-98.4, Tempol group: 98.5+/-13.7 mm(3)). In contrast, Tempol administered 15 min prior to reperfusion reduced neither the TBARS level nor the size of the infarction. These results indicate that Tempol administration at the time of reperfusion reduced lipid peroxidation by scavenging free radicals, resulting in a reduction of the infarct size.

Animals↗