PubMed Health⌕ Search

Biomedical subjects

Kazuki Nakanishi

Publications and source records attributed to Kazuki Nakanishi.

At least 19 recordsLinked to original sources

Performance of monolithic silica capillary columns with increased phase ratios and small-sized domains.

Monolithic silica capillary columns for HPLC were prepared from tetramethoxysilane to have smaller sized domains and increased phase ratios as compared to previous materials, and their performance was evaluated. The monolithic silica columns possessed an external porosity of 0.65-0.76 and a total porosity of 0.92-0.95 and showed considerably higher performance and greater retention factors in a reversed-phase mode after chemical modification than columns previously reported. An octadecylsilylated monolithic silica column with the smallest domain size (through-pores of approximately 1.3 microm and silica skeletons of approximately 0.9 microm) showed a plate height of less than 5 microm at optimum linear velocities (u) of 2-3 mm/s in 80% acetonitrile for a solute having retention factors of approximately 1, and approximately 7 microm at u = 8 mm/s. With a permeability similar to that of a column packed with 5-microm particles, the monolithic silica columns were able to attain column efficiencies comparable to that of particulate columns packed with 2-2.5-microm particles, and showed performance in the "forbidden region" for the previous columns. The performance of the monolithic column can be compared favorably with that of a particle-packed column when 15,000-30,000 or more theoretical plates are desired at a pressure drop of 20-40 MPa or lower. The increased homogeneity of the co-continuous structures, in addition to the small-sized domains, contributed to the higher performance as compared to previous monolithic silica columns.

Benzene Derivatives↗

High-throughput protein digestion by trypsin-immobilized monolithic silica with pipette-tip formula.

Based on the monolithic silica gel materials with hierarchical pore structure and on the SPE devices (MonoTip) developed thereof, a trypsin-immobilized monolithic silica in a pipette tip (MonoTip Trypsin) suitable for digesting proteins has been newly developed. The surface of monolithic silica fixed into the tip was chemically modified with trypsin via an aminopropyl group. Trypsin-immobilized monolith successfully performed a rapid digestion of reduced and alkylated proteins with only a few times pipetting operation for the pre-treatment procedure of chromatographic analysis. The novel solid-phase digestion tool using monolithic silica allows a high-throughput trypsin proteolysis of bio-substances in proteomics.

Chromatography, High Pressure Liquid↗

Mutual consistency between simulated and measured pressure drops in silica monoliths based on geometrical parameters obtained by three-dimensional laser scanning confocal microscope observations.

The geometrical properties of co-continuous macroporous silica monoliths have been studied by laser scanning confocal microscopy (LSCM) and a comparison has been made with those obtained by conventional mercury intrusion method. Tetrahedral skeleton model (TMS), which mimics the gel skeleton shape of monoliths, was compared with real monoliths in terms of macropore and porosity using the geometrical parameters extracted from the LSCM observations. Liquid flow behavior through the macroporous silica monoliths was examined in comparison with those simulated using TSM, based on the geometrical properties obtained from LSCM observations. Heterogeneity in macropore topology and connectivity in pores and skeletons are suggested to contribute to the improvement of the model structure for macroporous monoliths.

Microscopy, Confocal↗

Anisotropic siloxane-based monolith prepared in confined spaces.

When bicontinuous gels are prepared via sol-gel method in a 2-dimensionally (2D) confined space, the gel skeletons in the vicinity of interface of a mold are elongated perpendicular to the interface. This phenomenon was attributed to the dynamic wetting of polymerizing siloxane phase onto the interface of the mold under gravity. In this paper, we report the successful preparation of monolithic columns with an oriented pillar structure in a variety of 2D confined spaces. Starting from a solution, which consists of methyltrimethoxysilane (MTMS), the macroporous structure is prepared in situ by a completely spontaneous process. In the oriented pillar structure, bicontinuous siloxane skeletons deformed or disappeared and most pillars are oriented along the direction of gravity. Gel morphologies with the pillar structure were examined by scanning electron microscopy (SEM) and laser scanning confocal microscopy (LSCM). Geometrical information on gel morphologies was numerically derived from the obtained 3D LSCM images.

Acetamides↗

High-performance liquid chromatographic enantioseparations on capillary columns containing monolithic silica modified with amylose tris(3,5-dimethylphenylcarbamate).

Monolithic capillary columns containing native silica were modified by in situ coating with amylose tris(3,5-dimethylphenylcarbamate) and applied for enantioseparations in capillary liquid chromatography. Capillary columns were examined for 10 standard racemic compounds in order to compare the performance of monolithic silica columns with the common, 4.6mm I.D. high-performance liquid chromatographic columns packed with particulate silica. The effects of polysaccharide coating and of the linear velocity of the mobile phase on peak performance were studied. Enantioseparations with an analysis time below 1min were achieved for some chiral analytes.

Amylose↗

High-performance liquid chromatographic enantioseparations on capillary columns containing crosslinked polysaccharide phenylcarbamate derivatives attached to monolithic silica.

Monolithic capillary columns containing native silica gel were covalently modified with 3,5-disubstituted phenylcarbamate derivatives of cellulose and amylose and applied for enantioseparations in capillary LC. The method previously used for covalent immobilization of polysaccharide phenylcarbamate derivatives onto the surface of microparticulate silica gel was successfully adapted for in situ modification of monolithic fused-silica capillary columns. The effects of the nature of polysaccharide and the substituents, as well as of multiple covalent immobilization of polysaccharide derivative on chromatographic performance of capillary columns were studied. The capillary columns obtained using this technique are stable in all solvents commonly used in LC and exhibit promising enantiomer resolving ability.

Amylose↗

Thick silica gel coatings on methylsilsesquioxane monoliths using anisotropic phase separation.

Silica gel coatings on methyltrimethoxysilane (MTMS)-derived monoliths have been studied using wetting transition. Wetting transition is observed in a small confined space, where a coating solution phase-separates into a well-coarsened dimension, making all the phase-separating polymerizing silica phase dynamically flow onto the existing surface of a mold. Bulk coating experiments have shown reductions of both macropore volume and diameter due to the coated layer. Comparing HPLC efficiencies of the coated monolith with those of the non-coated MTMS monolith revealed that the retention factors drastically increased in both normal- and reversed-phase modes. This is attributed to the existence of considerable amounts of accessible micropores left inside the coated layer, where analyte molecules travel and adsorb for a considerable period of time.

Journal Article↗

Short communication performance of octadecylsilylated monolithic silica capillary columns of 530 microm inner diameter in HPLC.

Monolithic silica capillary columns were successfully prepared in a fused silica capillary of 530 microm inner diameter and evaluated in HPLC after octadecylsilylation (ODS). Their efficiency and permeability were compared with those of columns pakked with 5-microm and 3-microm ODS-silica particles. The monolithic silica columns having different domain sizes (combined size of through-pore and skeleton) showed 2.5-4.0-times higher permeability (K= 5.2-8.4 x 10(-14) m2) than capillary columns packed with 3-mm particles, while giving similar column efficiency. The monolithic silica capillary columns gave a plate height of about 11-13 microm, or 11 200-13 400 theoretical plates/150 mm column length, in 80% methanol at a linear mobile phase velocity of 1.0 mm/s. The monolithic column having a smaller domain size showed higher column efficiency and higher pressure drop, although the monolithic column with a larger domain size showed better overall column performance, or smaller separation impedance (E value). The larger-diameter (530 microm id) monolithic silica capillary column afforded a good peak shape in gradient elution of proteins at a flow rate of up to 100 microL/min and an injection volume of up to 10 microL.

Journal Article↗

Experimental validation of the tetrahedral skeleton model pressure drop correlation for silica monoliths and the influence of column heterogeneity.

This paper describes the use of computational fluid dynamics for the calculation of the flow resistance through computer-generated models resembling silica monoliths. This study was undertaken to determine the effect of skeleton heterogeneity on the flow resistance and, more precisely, to test the hypothesis that increased skeleton heterogeneity decreases the flow resistance. To evaluate the proposed model, 24 real silica monoliths have been prepared using the same method, covering a wide range of skeleton sizes (2.2 microm < d(s) < 8 microm) and porosities (0.47 < epsilon < 0.66). The permeability of these monoliths was determined by pressure drop measurements, and structural information was obtained by image analysis of laser scanning confocal microscopy-generated 3D images of the skeleton structure. The results indicate that the presence of preferential flow paths due to an increased heterogeneity of the flow through pore space reduces the flow resistance of monolithic media. It is also shown that the pore size is hence a much better suited scaling dimension than the skeleton size to reduce the permeability of monolithic columns.

Journal Article↗

Silica monolithic membrane as separation medium. Summable property of different membranes for high-performance liquid chromatographic separation.

We studied an applicability of a silica monolithic membrane as separation medium for high-performance liquid chromatography (HPLC). We prepared porous monolithic silica membranes having a three-dimensional network structure to cut and shape into a membrane separation medium. We evaluated chromatographic properties of a variety of solutes using a column containing the membranes with HPLC to elucidate summable property of the membrane separation media. In addition, we made brief study on separation of HbA1c in whole blood with the stacked" membranes having different surface characteristics in one column, which is a membrane column. We confirmed that the membrane column was able to separate HbA1c from other matrix in whole blood to some extent, and it also had an excellent ability for hydrophobic and ion exchange adsorption.

Chromatography, High Pressure Liquid↗

Titania-coated monolithic silica as separation medium for high performance liquid chromatography of phosphorus-containing compounds.

A method of preparing titania-coated monolithic silica stationary phase has been developed to achieve liquid chromatographic separation of phosphorus-containing compounds, which have recently been attracting increasing attention in biochemical research. The titania-coated silica columns exhibited efficient separation with low pressure drop, which is a typical feature of monolithic structures, and also possessed phospho-selectivity, which is a unique property of the titania surface. The material characteristics of titania-coated monolithic silica were examined, and then resin-clad columns were applied to the HPLC analysis of phosphorylated compounds. Highly efficient separation of phosphorylated substances indicated that the novel titania-coated monolithic silica column will find applications as a useful tool in the field of biochemistry, especially in post-genomic analyses.

Journal Article↗

Development of a monolithic silica extraction tip for the analysis of proteins.

In proteomics, pre-treatment of sample is the most important procedure to remove the matrix for interfacing with mass spectrometry (MS). Additionally, for the samples with low concentration, the process of pre-concentration is required before MS analysis. We have newly developed solid-phase extraction (SPE) tool with pipette-tip shape for purification of bio-samples of various characteristics, utilizing monolithic silica gel as medium. The monolithic silica surface was modified with a C18 phase or coated with titania phase. A C18-bonded tip and a non-modified tip were used for sample concentration, desaltination and removal of detergents from sample. A titania-coated tip was also applied for purification and concentration of phosphorylated peptides. This novel pre-treatment method using monolithic silica extraction tip is much effective and suitable for protein analysis.

Chromatography, High Pressure Liquid↗

Microanalysis for MDR1 ATPase by high-performance liquid chromatography with a titanium dioxide column.

MDR1 is clinically important because it is involved in multidrug resistance of cancer cells and affects the pharmacokinetics of various drugs. Because MDR1 harnesses adenosine 5'-triphosphate (ATP) hydrolysis for transporting drugs, examining the effect on ATPase activity is imperative for understanding the interactions between drugs and MDR1. However, conventional assay systems for ATPase activity are not sensitive enough for screening drugs using purified MDR1. Here we report a novel method to measure ATPase activity of MDR1 using high-performance liquid chromatography equipped with a titanium dioxide column. The amount of adenosine 5'-diphosphate (ADP) produced by the ATPase reaction was determined within 2 min with a titanium dioxide column (4.6 mm ID x 100 mm). The relationship between ADP amount and chromatogram peak area was linear from 5 pmol to 10 nmol. This method made it possible to reduce the amount of purified MDR1 required for a reaction to 0.5 ng, about 1/20th of the conventional colorimetric inorganic phosphate detection assay. This method is sensitive enough to detect any subtle changes in ATPase activity of MDR1 induced by drugs and can be applied to measure ATPase activity of any protein.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Simple and comprehensive two-dimensional reversed-phase HPLC using monolithic silica columns.

Simple and comprehensive two-dimensional (2D)-HPLC was studied in a reversed-phase mode using monolithic silica columns for second-dimension (2nd-D) separation. Every fraction from the first column, 15 cm long (4.6-mm i.d.), packed with fluoroalkylsilyl-bonded (FR) silica particles, was subjected to the separation in the 2nd-D using one or two octadecylsilylated (C(18)) monolithic silica columns (4.6-mm i.d., 3 cm). Monolithic silica columns in the 2nd-D were eluted at a flow rate of up to 10 mL/min with separation time of 30 s that meets the fractionation every 15-30 s at the first dimension (1st-D) operated at a flow rate of 0.4-0.8 mL/min. Three cases were studied. (1) In the simplest scheme of 2D-HPLC, effluent of the 1st-D was directly loaded into an injector loop of 2nd-D HPLC for 28 s, and 2 s was allowed for injection. (2) Two six-port valves each having a sample loop were used to hold the effluent of the 1st-D alternately for 30 s for one 2nd-D column to effect comprehensive 2D-HPLC without the loss of 1st-D effluent. (3) Two monolithic silica columns were used for 2nd-D by using a switching valve and two sets of 2nd-D chromatographs separating each fraction of the 1st-D effluent with the two 2nd-D columns alternately. In this case, two columns of the same stationary phase (C(18)) or different phases, C(18) and (pentabromobenzyloxy)propylsilyl-bonded (PBB), could be employed at the 2nd-D, although the latter needed two complementary runs. The systems produced peak capacity of approximately 1000 in approximately 60 min in cases 1 and 2 and in approximately 30 min in case 3. The three stationary phases, FR, C(18), and PBB, showed widely different selectivity from each other, making 2D separations possible. The simple and comprehensive 2D-HPLC utilizes the stability and high efficiency at high linear velocities of monolithic silica columns.

Journal Article↗

Structural formation of hybrid siloxane-based polymer monolith in confined spaces.

Structural deformation of phase-separated methylsiloxane gel under the influence of a surface has been studied. Competitive wetting of siloxane gel phase on a surface during phase formation is found to significantly affect the final morphology in a confined space. When the spinodal wavelength is sufficiently shorter than the size of the available space, a uniform bicontinuous structure forms in confined geometry. However, gel skeletons in the vicinity of a surface are elongated with decreasing size of the space, and finally when the size of the space becomes shorter than the spinodal wavelength, all the gel phase wets on a surface, showing a "wetting transition". Homogeneous bicontinuous methylsiloxane gels were successfully prepared, avoiding such structural deformation, in a long cylindrical fused silica capillary and used for capillary HPLC. The capillary gels exhibited excellent separation efficiency of nitrobenzenes and it was found that the surface character can be altered by incorporating surfactants, which will enable more advanced and extended control of surface character, depending on the analytes.

Chromatography↗

High-performance liquid chromatographic enantioseparations on capillary columns containing monolithic silica modified with cellulose tris(3,5-dimethylphenylcarbamate).

Monolithic capillary columns containing native silica gel were modified with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) and used for enantioseparations in capillary liquid chromatography. The method adopted for in situ enantioselective modification of monolithic fused silica capillary columns by coating with CDPMC appears to be fairly simple and fast. High efficiency enantioseparations of test racemic compounds and s(everal chiral drugs were achieved in a short time. It was possible to increase the amount of chiral selector present by multiple coating of monoliths with CDMPC. The baseline enantioseparation of 2,2,2-trifluoro-1-(9-anthryl)ethanol was achieved in an analysis time less than 30 s with this capillary column. In addition, reproducible enantioseparations were obtained when the chiral selector was removed from the monolithic column by flushing it with appropriate solvent and the column recoated.

Carbamates↗

Simple 2D-HPLC using a monolithic silica column for peptide separation.

Separation of peptides by fast and simple two-dimensional (2D)-HPLC was studied using a monolithic silica column as a second-dimension (2nd-D) column. Every fraction from the first column, 5 cm long (2.1 mm ID) packed with polymer-based cation exchange beads, was subjected to separation in the 2nd-D using an octadecylsilylated (C18) monolithic sillica column (4.6 mm ID, 2.5 cm). A capillary-type monolithic silica C18column (0.1 mm ID, 10 cm) was also employed as a 2nd-D column with split flow/injection. Effluentof the first dimension (1st-D) was directly loaded into an injector loop of 2nd-D HPLC. UV and MS detection were successfully carried out at high linear velocity of mobile phase at 2nd-D using flow splitting for the 4.6 mm ID 2nd-D column, or with directconnection of the capillary column to the MS interface. Two-minute fractionation inthe 1st-D, 118-second loading, and 2-second injection by the 2nd-D injector, allowed one minute for gradient separation in the 2nd-D, resulting in a maximum peak capacity of about 700 within 40 min. The use of a capillary column in solvent consumption and better MS detectability compared to a larger-sized column. This kind of fast and simple 2D-HPLC utilizing monolithic silica columns will be useful for the separation of complex mixtures in a short time.

Animals↗

Monolithic silica-based capillary reversed-phase liquid chromatography/electrospray mass spectrometry for plant metabolomics.

Application of C18 monolithic silica capillary columns in HPLC coupled to ion trap mass spectrometry detection was studied for probing the metabolome of the model plant Arabidopsis thaliana. It could be shown that the use of a long capillary column is an easy and effective approach to reduce ionization suppression by enhanced chromatographic resolution. Several hundred peaks could be detected using a 90-cm capillary column for LC separation and a noise reduction and automatic peak alignment software, which outperformed manual inspection or commercially available mass spectral deconvolution software.

Arabidopsis↗