PubMed Health⌕ Search

Biomedical subjects

Kazuo Miyasaka

Publications and source records attributed to Kazuo Miyasaka.

At least 19 recordsLinked to original sources

Effect of treatment time on outcome of radiotherapy for oral tongue carcinoma.

PURPOSE: To investigate the importance of total treatment time on the outcome of external beam radiotherapy (EBRT) followed by internal brachytherapy for the treatment of oral tongue carcinoma. METHODS AND MATERIALS: Ninety-four patients with T1-T2N0 squamous cell carcinoma of the oral tongue were treated using 35-40 Gy EBRT followed by 35-40 Gy interstitial (137)Cs brachytherapy between 1985 and 1995. The interval between the end of EBRT and the start of interstitial treatment varied for numerous unavoidable reasons, with a mean of 25.3 days and standard deviation of 3.5 days. The median follow-up period was 59.1 months (range 6-146). RESULTS: The actuarial survival rate of all cases was 78.4% at 5 years. The 5-year local control rate for those with T1 and T2 was 92.8% and 62.7%, respectively (p < 0.05). The local control rate of the primary tumor in patients with a total treatment time >43 days was statistically lower than that of patients with a total treatment time < or =43 days in all patients (p < 0.05) and in the subgroup of Stage T2 patients (p < 0.05). Multivariate analysis revealed that the local control rates in all cases were significantly related to the T stage (T2 or not), total treatment time (>43 days or not), and location of disease (posterior or not). Regression analysis for 5-year local control as a function of treatment duration showed a 2% loss of local control per day of treatment extension >30 days (r = 0.94, p < 0.01). CONCLUSION: The total treatment time was associated with the local control rate in the RT of oral tongue carcinoma. The loss in local control was estimated to be 2.0% per additional day in our series for oral tongue carcinoma.

Adult↗

Hypofractionated stereotactic radiotherapy alone without whole-brain irradiation for patients with solitary and oligo brain metastasis using noninvasive fixation of the skull.

PURPOSE: To evaluate the efficacy and toxicity of hypofractionated stereotactic radiotherapy (HSRT) using noninvasive fixation of the skull on solitary or oligo brain metastatic patients as an alternative to stereotactic radiosurgery (SRS) using invasive fixation. PATIENTS AND METHODS: The subjects were 87 patients who had 4 or fewer brain metastases (50 solitary, 37 oligometastases). Treatment was conducted on 159 metastases by using a linac-based stereotactic system. The median isocentric dose was 35 Gy in 4 fractions. Whole-brain irradiation was not applied as an initial treatment. For the salvage treatment of metachronous brain metastases, repeat HSRT or whole-brain irradiation was applied. RESULTS: The actuarial 1-year local tumor control rate was 81%. Treatment-related complications were observed in 4 patients in the early period (<3 months) and in 2 patients in the late period. The median survival period was 8.7 months. Metachronous brain metastases occurred in 30 patients, and none of the 18 patients who were eligible for salvage HSRT refused to receive it again. CONCLUSIONS: Hypofractionated stereotactic radiotherapy achieved tumor control and survival equivalent to those of SRS reported in the literature. The results suggested that HSRT could be an alternative for solitary or oligo brain metastatic patients with less toxicity and less invasiveness compared to SRS.

Actuarial Analysis↗

Alveolar echinococcosis: MR findings in the liver.

PURPOSE: To clarify the magnetic resonance (MR) imaging findings of alveolar echinococcosis in the liver. MATERIALS AND METHODS: Thirty-five patients with 50 lesions histologically proven to be alveolar echinococcosis were evaluated with MR imaging. Lesions were assessed with regard to the distribution pattern of solid and cystic components and pattern of contrast material enhancement. RESULTS: Cystic components exhibited two patterns at T2-weighted MR imaging: small round cysts and large and/or irregular cysts. Forty-eight lesions (96%) contained small round cysts. Twenty-six lesions (52%) had large and/or irregular cysts. Forty-five lesions (90%) were associated with a solid component. MR imaging characteristics were categorized into five types: multiple small round cysts without a solid component (two lesions [4%], type 1), multiple small round cysts with a solid component (20 lesions [40%], type 2), a solid component surrounding large and/or irregular cysts with multiple small rounds cysts (23 lesions [46%], type 3), a solid component without cysts (two lesions [4%], type 4), and a large cyst without a solid component (three lesions [6%], type 5). In most cases (97%), contrast enhancement was weak. CONCLUSION: The MR findings of alveolar echinococcosis in the liver are multiple small round cysts with a weakly enhanced solid component. The cystic component can be a large and/or irregular lesion, and such lesions are depicted clearly at T2-weighted MR imaging.

Adolescent↗

Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy.

PURPOSE: To examine the feasibility and reliability of insertion of internal fiducial markers into various organs for precise setup and real-time tumor tracking in radiotherapy (RT). MATERIALS AND METHODS: Equipment and techniques for the insertion of 2.0-mm-diameter gold markers into or near the tumor were developed for spinal/paraspinal lesions, prostate tumors, and liver and lung tumors. Three markers were used to adjust the center of the mass of the target volume to the planned position in spinal/paraspinal lesions and prostate tumors (the three-marker method). The feasibility of the marker insertion and the stability of the position of markers were tested using stopping rules in the clinical protocol (i.e., the procedure was abandoned if 2 of 3 or 3 of 6 patients experienced marker dropping or migration). After the evaluation of the feasibility, the stability of the marker positions was monitored in those patients who entered the dose-escalation study. RESULTS: Each of the following was shown to be feasible: bronchoscopic insertion for the peripheral lung; image-guided transcutaneous insertion for the liver; cystoscopic and image-guided percutaneous insertion for the prostate; and surgical implantation for spinal/paraspinal lesions. Transcutaneous insertion of markers for spinal/paraspinal lesions and bronchoscopic insertion for central lung lesions were abandoned. Overall, marker implantation was successful and was used for real-time tumor tracking in RT in 90 (90%) of 100 lesions. No serious complications related to the marker insertion were noted for any of the 100 lesions. Using three markers surgically implanted into the vertebral bone, the mean +/- standard deviation in distance among the three markers was within 0.2 +/- 0.6 mm (range -1.4 to 0.8) through the treatment period of 30 days. The distance between the three markers gradually decreased during RT in five of six prostate cancers, consistent with a mean rate of volume regression of 9.3% (range 0.015-13%) in 10 days. CONCLUSIONS: Internal 2.0-mm-diameter gold markers can be safely inserted into various organs for real-time tumor tracking in RT using the prescribed equipment and techniques. The three-marker method has been shown to be a useful technique for precise setup for spinal/paraspinal lesions and prostate tumors.

Adenocarcinoma↗

Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system.

PURPOSE: To investigate the three-dimensional (3D) intrafractional motion of liver tumors during real-time tumor-tracking radiotherapy (RTRT). MATERIALS AND METHODS: The data of 20 patients with liver tumors were analyzed. Before treatment, a 2-mm gold marker was implanted near the tumor. The RTRT system used fluoroscopy image processor units to determine the 3D position of the implanted marker. A linear accelerator was triggered to irradiate the tumor only when the marker was located within a permitted region. The automatically recorded tumor-motion data were analyzed to determine the amplitude of the tumor motion, curve shape of the tumor motion, treatment efficiency, frequency of movement, and hysteresis. Each of the following clinical factors was evaluated to determine its contribution to the amplitude of movement: tumor position, existence of cirrhosis, surgical history, tumor volume, and distance between the isocenter and the marker. RESULTS: The average amplitude of tumor motion in the 20 patients was 4 +/- 4 mm (range 1-12), 9 +/- 5 mm (range 2-19), and 5 +/- 3 mm (range 2-12) in the left-right, craniocaudal, and anterior-posterior (AP) direction, respectively. The tumor motion of the right lobe was significantly larger than that of the left lobe in the left-right and AP directions (p = 0.01). The tumor motion of the patients with liver cirrhosis was significantly larger than that of the patients without liver cirrhosis in the left-right and AP directions (p < 0.004). The tumor motion of the patients who had received partial hepatectomy was significantly smaller than that of the patients who had no history of any operation on the liver in the left-right and AP directions (p < 0.03). Thus, three of the five clinical factors examined (i.e., tumor position in the liver, cirrhosis, and history of surgery on the liver) significantly affected the tumor motion of the liver in the transaxial direction during stereotactic irradiation. Frequency analysis revealed that for 9 (45%) of the 20 tumors, the cardiac beat caused measurable motion. The 3D trajectory of the tumor showed hysteresis for 4 (20%) of the 20 tumors. The average treatment efficiency of RTRT was 40%. CONCLUSIONS: Tumor location, cirrhosis, and history of surgery on the liver all had an impact on the intrafractional tumor motion of the liver in the transaxial direction. This finding should be helpful in determining the smallest possible margin in individual cases of radiotherapy for liver malignancy.

Computer Systems↗

Tolerance of organs at risk in small-volume, hypofractionated, image-guided radiotherapy for primary and metastatic lung cancers.

PURPOSE: To determine the organ at risk and the maximum tolerated dose (MTD) of radiation that could be delivered to lung cancer using small-volume, image-guided radiotherapy (IGRT) using hypofractionated, coplanar, and noncoplanar multiple fields. MATERIALS AND METHODS: Patients with measurable lung cancer (except small-cell lung cancer) 6 cm or less in diameter for whom surgery was not indicated were eligible for this study. Internal target volume was determined using averaged CT under normal breathing, and for patients with large respiratory motion, using two additional CT scans with breath-holding at the expiratory and inspiratory phases in the same table position. Patients were localized at the isocenter after three-dimensional treatment planning. Their setup was corrected by comparing two linacographies that were orthogonal at the isocenter with corresponding digitally reconstructed images. Megavoltage X-rays using noncoplanar multiple static ports or arcs were used to cover the parenchymal tumor mass. Prophylactic nodal irradiation was not performed. The radiation dose was started at 60 Gy in 8 fractions over 2 weeks (60 Gy/8 Fr/2 weeks) for peripheral lesions 3.0 cm or less, and at 48 Gy/8 Fr/2 weeks at the isocenter for central lesions or tumors more than 3.0 cm at their greatest dimension. RESULTS: Fifty-seven lesions in 45 patients were treated. Tumor size ranged from 0.6 to 6.0 cm, with a median of 2.6 cm. Using the starting dose, 1 patient with a central lesion died of a radiation-induced ulcer in the esophagus after receiving 48 Gy/8 Fr at isocenter. Although the contour of esophagus received 80% or less of the prescribed dose in the planning, recontouring of esophagus in retrospective review revealed that 1 cc of esophagus might have received 42.5 Gy, with the maximum dose of 50.5 Gy. One patient with a peripheral lesion experienced Grade 2 pain at the internal chest wall or visceral pleura after receiving 54 Gy/8 Fr. No adverse respiratory reaction was noted in the symptoms or respiratory function tests. The 3-year local control rate was 80.4% +/- 7.1% (a standard error) with a median follow-up period of 17 months for survivors. Because of the Grade 5 toxicity, we have halted this Phase I/II study and are planning to rearrange the protocol setting accordingly. The 3-year local control rate was 69.6 +/- 10.6% for patients who received 48 Gy and 100% for patients who received 60 Gy (p = 0.0442). CONCLUSIONS: Small-volume IGRT using 60 Gy in eight fractions is highly effective for the local control of lung tumors, but MTD has not been determined in this study. The organs at risk are extrapleural organs such as the esophagus and internal chest wall/visceral pleura rather than the pulmonary parenchyma in the present protocol setting. Consideration of the uncertainty in the contouring of normal structures is critically important, as is uncertainty in setup of patients and internal organ in the high-dose hypofractionated IGRT.

Adult↗

Clinical assessment of hepatic functional reserve using 99mTc DTPA galactosyl human serum albumin SPECT to prognosticate chronic hepatic diseases--validation of the use of SPECT and a new indicator.

RATIONALE: It is generally known that scintigraphy of 99mTc diethylenetriamine pentaacetic acid-galactosyl human serum albumin (99mTc-GSA) is useful for assessing hepatic functional reserve. For hepatic functional indicators, the index of the calculated planar image has been used in previous studies. However, there have been few reports that suggest that the indicators calculated from static SPECT data would be useful for the assessment of hepatic function. The aims of this study were to establish a simple method for assessing hepatic functional reserve using the liver SPECT of 99mTc-GSA and to apply this method for rich stratification in patients with chronic hepatic diseases. METHODS: A liver phantom (a 50% concentration of 99mTc solution) was used to compare the planar and SPECT methods. According to the definition of the new indicator, the liver SPECT of 99mTc-GSA was divided by a syringe SPECT of 99mTc-GSA and was called the liver uptake ratio (LUR). We correlated the LUR and the liver uptake ratio calculated according to the blood-sampling method. 99mTc-GSA SPECT was performed in 137 patients with hepatic diseases, including chronic hepatic diseases, and 20 healthy volunteers. The LUR was correlated between the formed subtypes for all subjects. RESULTS: The acquired phantom-count ratio calculated by the SPECT method was more accurate than that acquired by the planar method. A good correlation was obtained between the LUR and the blood-sampling method (r = 0.971). The LUR was significantly lower in subjects with severe cirrhosis than in healthy subjects or those with chronic hepatitis and mild cirrhosis, and it was significantly lower in subjects with chronic hepatitis and mild cirrhosis than in healthy subjects. The LUR was significantly correlated with other hepatic function tests. Based on LUR, the chronic hepatic diseases were divided into two groups: Group A, with LURs 30% and higher, and Group B, with LURs below 30%. An LUR of 30% marked the 25th percentile of the mild-cirrhosis group. The cumulative survival rates were lower in Group B than in Group A. CONCLUSION: The SPECT method was superior to the planar method for assessing LURs. LUR was a suitable indicator of 99mTc-GSA clearance from the blood pool and of binding to the asialo-glycoprotein receptor. LUR is a simple and clinically useful indicator for the assessment of hepatic functional reserve in chronic hepatic diseases.

Chronic Disease↗

Visualization of the corticospinal tract pathway using magnetic resonance axonography and magnetoencephalography for stereotactic irradiation planning of arteriovenous malformations.

Corticospinal tract (CST) information using anisotropic diffusion-weighted imaging and magnetoencephalography were integrated into radiosurgical planning for two patients with deeply seated arteriovenous malformation. The volume of CST receiving >10 Gy, >15 Gy, and maximum dose of CST could be reduced when plans were created with the aid of CST information compared with plans without the information. The results indicate that the use of CST information might reduce the risk of post-radiosurgical motor disturbance resulting from radiation necrosis.

Arteriovenous Malformations↗

Focal fractionated radiotherapy for intramedullary spinal arteriovenous malformations: 10-year experience.

OBJECT: Radiosurgical treatment of spinal arteriovenous malformations (AVMs) is becoming a practical therapeutic option as methodology improves, but no comparative study has yet been published on focal fractionated radiotherapy. The authors report their experience with conventional and hypofractionated radiotherapy for spinal AVM. METHODS: Candidates for this study were patients who experienced symptoms due to an intramedullary AVM but were ineligible for embolization or surgery. Of 21 patients with spinal AVMs, 10 cases in a 10-year period met this criterion. Angiography and contrast-enhanced computerized tomography scanning were used for treatment planning in all cases. Fractionated radiotherapy was performed using a linear accelerator, extracranial immobilization system, and frequent orthogonal linacographic verification. The starting radiation dose was 32 Gy in two, 36 Gy in three, and 40 Gy in two patients, in a regimen involving 1.8 to 2-Gy daily fractions; this was recently changed to a hypofractionation schedule of 30 Gy (in eight sessions) in one and 20 Gy (in four sessions) in two patients. RESULTS: The follow-up period ranged from 26 to 124 months (median of 49 months). There were no hemorrhages nor any adverse reactions attributable to irradiation. Of the seven patients who consented to undergo follow-up angiography, the nidus size decreased in five, but complete obliteration did not occur in any patient. CONCLUSIONS: Because no patient experienced adverse effects, the maximum tolerable radiation dose for the spinal cord associated with an AVM could not be identified, although it presumably is higher than those administered. The lack of rebleeding in patients in whom complete angiographic occlusion was absent suggests that the natural history of spinal AVMs may be less aggressive than previously reported.

Adolescent↗

Anterior spinal artery and artery of Adamkiewicz detected by using multi-detector row CT.

BACKGROUND AND PURPOSE: Our purpose was to evaluate the visualization of the artery of Adamkiewicz (AKA) and the anterior spinal artery (ASA) by using multi-detector row CT. Preoperative detection of the AKA and ASA is important for prevention of ischemic complications of thoracoabdominal aortic surgery. METHODS: Data from contrast-enhanced CT of the abdomen of 19 consecutive patients with known or suspected liver disease were evaluated. The scanning range was set from the level of the diaphragm to the lower edge of the liver. After bolus injection of contrast material (100 mL of iohexol, 350 mgI/mL, 5 mL/s), arterial phase scans were obtained by using a four-channel multi-detector row CT scanner. The scanning parameters included a detector row configuration of 4 x 2 mm, a pitch of 5:1, a gantry rotation speed of 0.5 s, 120 kVp, and 150 mAs. Arterial phase coronal multiplanar reconstruction scans obtained parallel to the spinal cord were evaluated by two neuroradiologists. The detectability of ASA and AKA was analyzed. RESULTS: The AKA was visualized on the scans of 13 of 19 patients (68%). The segmental level of AKA origin ranged from T10 to L2. The AKA originated from the left side in nine patients (69%) and the right side in four patients (31%). The ASA was visualized on the scans of all patients (100%). For 16 of the 19 patients, the ASA was detected in its full length from the cranial edge of the scan range. However, the ascending branch of the ASA distal to the junction of the AKA was not detected for the remaining three patients. CONCLUSION: The AKA and ASA can be visualized by using multi-detector row CT with the use of IV administered contrast material. Multi-detector row CT could be a useful tool in the evaluation of spinal vascular structures.

Adult↗

Quantitative cerebral blood flow measurement with dynamic perfusion CT using the vascular-pixel elimination method: comparison with H2(15)O positron emission tomography.

BACKGROUND AND PURPOSE: Blood vessels are usually conspicuous on dynamic CT perfusion images. The presence of large vessels may lead to overestimation of the quantitative value of cerebral blood flow (CBF). We evaluated the efficacy of the vascular-pixel elimination (VPE) method in quantitative CT perfusion imaging, in comparison with positron emission tomography (PET). METHODS: Five healthy volunteers underwent CT perfusion and PET studies. A four-channel multi-detector row CT scanner was used. Dynamic cine scanning was performed after bolus injection of an intravenous contrast agent. CT-CBF was calculated by the central volume principle and deconvolution method. PET was performed after infusion of (15)O-labeled water. PET-CBF was calculated by using a nonlinear least squares method. Average CBF values of the whole section, gray matter, and white matter with both CT and PET were compared after image registration. The comparison was performed with and without VPE. In the VPE method, the vascular pixels were defined by the cerebral blood volume value of the pixel. The threshold of VPE was changed from 5 to 20 mL/100 g. Pixel-by-pixel correlation between CT-CBF and PET-CBF and linear regression analysis were also performed. RESULTS: Without VPE, CT-CBF was overestimated in all subjects. As the VPE threshold decreased, CT-CBF decreased and the correlation coefficient increased. The best correlation was observed at a VPE threshold of 8 mL/100 g in four of the five subjects. Average CT-CBF values, without VPE, of the whole section, gray matter, and white matter were 59.01, 66.73, and 42.53 mL/100 g/min, respectively. With VPE (threshold, 8 mL/100 g), average CT-CBF values of the whole section, gray matter, and white matter were 45.56, 52.75, and 30.38, respectively. The corresponding PET-CBF values were 46.86, 50.89, and 38.20 mL/100 g/min, respectively. CONCLUSION: Vascular pixels should be excluded from the calculation of CT-CBF to avoid overestimation of the CBF values. If vascular pixels are excluded, CBF calculation with CT perfusion imaging is considerably accurate.

Adult↗

Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma.

PURPOSE: The efficacy of a prototypic fluoroscopic real-time tracking radiation therapy (RTRT) system using three gold markers (2 mm in diameter) for estimating translational error, rotational setup error, and the dose to normal structures was tested in 5 patients with spinal schwannoma and a phantom. METHODS AND MATERIALS: Translational error was calculated by comparing the actual position of the marker closest to the tumor to its planned position, and the rotational setup error was calculated using the three markers around the target. Theoretically, the actual coordinates can be adjusted to the planning coordinates by sequential rotation of gamma degrees around the z axis, beta degrees around the y axis, and alpha degrees around the x axis, in this order. We measured the accuracy of the rotational calculation using a phantom. Five patients with spinal schwannoma located at a minimum of 1-5 mm from the spinal cord were treated with RTRT. Three markers were inserted percutaneously into the paravertebral deep muscle in 3 patients and surgically into two consecutive vertebral bones in two other patients. RESULTS: In the phantom study, the discrepancies between the actual and calculated rotational error were -0.1 +/- 0.5 degrees. The random error of rotation was 5.9, 4.6, and 3.1 degrees for alpha, beta, and gamma, respectively. The systematic error was 7.1, 6.6, and 3.0 degrees for alpha, beta, and gamma, respectively. The mean rotational setup error (0.2 +/- 2.2, -1.3 +/- 2.9, and -1.3 +/- 1.7 degrees for alpha, beta, and gamma, respectively) in 2 patients for whom surgical marker implantation was used was significantly smaller than that in 3 patients for whom percutaneous insertion was used (6.0 +/- 8.2, 2.7 +/- 5.9, and -2.1 +/- 4.6 degrees for alpha, beta, and gamma). Random translational setup error was significantly reduced by the RTRT setup (p < 0.0001). Systematic setup error was significantly reduced by the RTRT setup only in patients who received surgical implantation of the marker (p < 0.0001). The maximum dose to the spinal cord was estimated to be 40.6-50.3 Gy after consideration of the rotational setup error, vs. a planned maximum dose of 22.4-51.6 Gy. CONCLUSION: The RTRT system employing three internal fiducial markers is useful to reduce translational setup error and to estimate the dose to the normal structures in consideration of the rotational setup error. Surgical implantation of the marker to the vertebral bone was shown to be sufficiently rigid for the calculation of the rotational setup error. Fractionated radiotherapy for spinal schwannoma using the RTRT system may well be an alternative or supplement to surgical treatment.

Adolescent↗

Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy.

BACKGROUND: The authors developed fluoroscopic real-time tumor-tracking radiation therapy (RTRT) by insertion of a gold marker using bronchofiberscopy to reduce uncertainties in organ motion and set-up error in external radiotherapy for moving tumors. The purpose of the current study was to evaluate RTRT's feasibility in lung carcinoma treatment. METHODS: The three-dimensional position of a 1.0-2.0 mm gold marker in or near the tumor was detected by two sets of fluoroscopies every 0.03 seconds. The treatment beam was gated to irradiate the tumor only when the position of the marker coincided with its planned position using the RTRT system. Bronchofiberscopic equipment for insertion of the marker into the lung tumor was developed and used for 20 lung tumors in 18 patients. Patients were given high dose hypofractionated focal irradiation (35-48 Gy in 4-8 fractions in 4-10 days) with a planning target volume margin of 5 mm for the tumor. RESULTS: The markers were successfully inserted and maintained at the inserted position during and after the radiotherapy in 14 (88%) of 16 peripheral-type lung tumors and in none of four central-type lung tumors, indicating that this method of RTRT was not feasible for central-type lung tumors. Tracking of the marker was successfully performed in 1 of 2 tumors with a 1.0 mm marker and in all of 12 tumors with a 1.5-2.0 mm marker. On the whole, 13 (65%) of the 20 tumors were successfully treated with RTRT. Local tumor control was achieved and maintained for all 12 patients (13 tumors), who were treated with RTRT, with a median followup of 9 months (range, 5-15). Localized radiation pneumonitis was found radiographically at the lung volume that was irradiated with about 20 Gy, without symptoms in all but one patient. CONCLUSIONS: The insertion of a gold marker into or near peripheral-type lung tumors using bronchofiberscopy is a feasible and safe technique. Excellent initial response and low incidence of clinical complications suggest that the high dose hypofractionated focal irradiation using the RTRT system can be a good local treatment for peripheral-type lung tumors.

Adult↗

Small-volume image-guided radiotherapy using hypofractionated, coplanar, and noncoplanar multiple fields for patients with inoperable Stage I nonsmall cell lung carcinomas.

BACKGROUND: Occasionally, medically compromised and/or elderly patients with nonsmall cell lung carcinomas (NSCLCs) cannot be treated surgically. We investigated small-volume hypofractionated image-guided radiotherapy (IGRT) without the need for breath control in patients with inoperable Stage I NSCLCs. METHODS: Between September 1996 and September 1999, 22 patients with Stage I NSCLCs, including 19 males and 3 females, were treated with IGRT. Among these patients, there were 13 Stage IA and 9 Stage IB tumors. The tumors ranged in size from 14.2 to 58.5 mm, with a median size of 26.7 mm. Of the 22 patients, 19 were unfit for surgical treatment due to poor pulmonary function, complications, and/or advanced age and 3 refused surgery. Computed tomographic scans (CT) of the primary tumor were taken during three respiratory phases and they were analyzed to determine the planning target volume, which included only the primary tumor with allowances for respiratory movement. The radiation doses administered at the edge of the moving tumor during normal breathing were 80% of the prescribed dose, either 48 or 60 Gy given in eight fractions over 2 weeks. Clinical evaluation, chest CT scan, and pulmonary function tests were performed before irradiation and at regular intervals for the post-IGRT follow-up. The median follow-up period was 24 months (range, 2-44 months; mean, 21.8 months) (at least 24 months for survivors). RESULTS: Of 17 tumors assessed at the initial follow-up 2-6 months after treatment (5 complete responses, 11 partial responses, and 1 progressive disease), 16 (94%) were controlled locally. One local recurrence was observed during the follow-up. The lung carcinoma-specific survival rate at 1 year was 94% and the 1-year actuarial recurrence-free survival rate was 71%. The lung carcinoma-specific survival rate at 2 years was 73% and the 2-year actuarial recurrence-free survival rate was 67%. The treatment was well tolerated and no major side effects were observed. Localized radiation pneumonitis was observed in all patients who were examined by CT scan, but the patients were asymptomatic. Parameters of pulmonary function, including vital capacity, total lung capacity, and diffusion capacity for carbon monoxide, decreased very little or not at all, indicating that IGRT rarely deteriorated pulmonary functions. CONCLUSIONS: Small-volume hypofractionated IGRT without breath control is a feasible and beneficial method for the curative treatment of patients with Stage I NSCLCs. It has the potential of a high local tumor control rate and low morbidity.

Aged↗

Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions.

PURPOSE: To quantify three-dimensional (3D) movement of the prostate gland with the patient in the supine and prone positions and to analyze the movement frequency for each treatment position. METHODS AND MATERIALS: The real-time tumor-tracking radiotherapy (RTRT) system was developed to identify the 3D position of a 2-mm gold marker implanted in the prostate 30 times/s using two sets of fluoroscopic images. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within the region of the planned coordinates relative to the isocenter. Ten patients with prostate cancer treated with RTRT were the subjects of this study. The coordinates of the gold marker were recorded every 0.033 s during RTRT in the supine treatment position for 2 min. The patient was then moved to the prone position, and the marker was tracked for 2 min to acquire data regarding movement in this position. Measurements were taken 5 times for each patient (once a week); a total of 50 sets for the 10 patients was analyzed. The raw data from the RTRT system were filtered to reduce system noise, and the amplitude of movement was then calculated. The discrete Fourier transform of the unfiltered data was performed for the frequency analysis of prostate movement. RESULTS: No apparent difference in movement was found among individuals. The amplitude of 3D movement was 0.1-2.7 mm in the supine and 0.4-24 mm in the prone positions. The amplitude in the supine position was statistically smaller in all directions than that in the prone position (p < 0.0001). The amplitude in the craniocaudal and AP directions was larger than in the left-right direction in the prone position (p < 0.0001). No characteristic movement frequency was detected in the supine position. The respiratory frequency was detected for all patients regarding movement in the craniocaudal and AP directions in the prone position. The results of the frequency analysis suggest that prostate movement is affected by the respiratory cycle and is influenced by bowel movement in the prone position. CONCLUSION: The results of this study have confirmed that internal organ motion is less frequent in the supine position than in the prone position in the treatment of prostate cancer. RTRT would be useful in reducing uncertainty due to the effects of the respiratory cycle, especially in the prone position.

Fluoroscopy↗

Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

PURPOSE: In this work, three-dimensional (3D) motion of lung tumors during radiotherapy in real time was investigated. Understanding the behavior of tumor motion in lung tissue to model tumor movement is necessary for accurate (gated or breath-hold) radiotherapy or CT scanning. METHODS: Twenty patients were included in this study. Before treatment, a 2-mm gold marker was implanted in or near the tumor. A real-time tumor tracking system using two fluoroscopy image processor units was installed in the treatment room. The 3D position of the implanted gold marker was determined by using real-time pattern recognition and a calibrated projection geometry. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within a certain volume. The system provided the coordinates of the gold marker during beam-on and beam-off time in all directions simultaneously, at a sample rate of 30 images per second. The recorded tumor motion was analyzed in terms of the amplitude and curvature of the tumor motion in three directions, the differences in breathing level during treatment, hysteresis (the difference between the inhalation and exhalation trajectory of the tumor), and the amplitude of tumor motion induced by cardiac motion. RESULTS: The average amplitude of the tumor motion was greatest (12 +/- 2 mm [SD]) in the cranial-caudal direction for tumors situated in the lower lobes and not attached to rigid structures such as the chest wall or vertebrae. For the lateral and anterior-posterior directions, tumor motion was small both for upper- and lower-lobe tumors (2 +/- 1 mm). The time-averaged tumor position was closer to the exhale position, because the tumor spent more time in the exhalation than in the inhalation phase. The tumor motion was modeled as a sinusoidal movement with varying asymmetry. The tumor position in the exhale phase was more stable than the tumor position in the inhale phase during individual treatment fields. However, in many patients, shifts in the exhale tumor position were observed intra- and interfractionally. These shifts are the result of patient relaxation, gravity (posterior direction), setup errors, and/or patient movement.The 3D trajectory of the tumor showed hysteresis for 10 of the 21 tumors, which ranged from 1 to 5 mm. The extent of hysteresis and the amplitude of the tumor motion remained fairly constant during the entire treatment. Changes in shape of the trajectory of the tumor were observed between subsequent treatment days for only one patient. Fourier analysis revealed that for 7 of the 21 tumors, a measurable motion in the range 1-4 mm was caused by the cardiac beat. These tumors were located near the heart or attached to the aortic arch. The motion due to the heartbeat was greatest in the lateral direction. Tumor motion due to hysteresis and heartbeat can lower treatment efficiency in real-time tumor tracking-gated treatments or lead to a geographic miss in conventional or active breathing controlled treatments. CONCLUSION: The real-time tumor tracking system measured the tumor position in all three directions simultaneously, at a sampling rate that enabled detection of tumor motion due to heartbeat as well as hysteresis. Tumor motion and hysteresis could be modeled with an asymmetric function with varying asymmetry. Tumor motion due to breathing was greatest in the cranial-caudal direction for lower-lobe unfixed tumors.

Adenocarcinoma↗

Image fusion between 18FDG-PET and MRI/CT for radiotherapy planning of oropharyngeal and nasopharyngeal carcinomas.

PURPOSE: Accurate diagnosis of tumor extent is important in three-dimensional conformal radiotherapy. This study reports the use of image fusion between (18)F-fluoro-2-deoxy-D-glucose positron emission tomography (18FDG-PET) and magnetic resonance imaging/computed tomography (MRI/CT) for better targets delineation in radiotherapy planning of head-and-neck cancers. METHODS AND MATERIALS: The subjects consisted of 12 patients with oropharyngeal carcinoma and 9 patients with nasopharyngeal carcinoma (NPC) who were treated with radical radiotherapy between July 1999 and February 2001. Image fusion between 18FDG-PET and MRI/CT was performed using an automatic multimodality image registration algorithm, which used the brain as an internal reference for registration. Gross tumor volume (GTV) was determined based on clinical examination and 18FDG uptake on the fusion images. Clinical target volume (CTV) was determined following the usual pattern of lymph node spread for each disease entity along with the clinical presentation of each patient. RESULTS: Except for 3 cases with superficial tumors, all the other primary tumors were detected by 18FDG-PET. The GTV volumes for primary tumors were not changed by image fusion in 19 cases (89%), increased by 49% in one NPC, and decreased by 45% in another NPC. Normal tissue sparing was more easily performed based on clearer GTV and CTV determination on the fusion images. In particular, parotid sparing became possible in 15 patients (71%) whose upper neck areas near the parotid glands were tumor-free by 18FDG-PET. Within a mean follow-up period of 18 months, no recurrence occurred in the areas defined as CTV, which was treated prophylactically, except for 1 patient who experienced nodal recurrence in the CTV and simultaneous primary site recurrence. CONCLUSION: This preliminary study showed that image fusion between 18FDG-PET and MRI/CT was useful in GTV and CTV determination in conformal RT, thus sparing normal tissues.

Adult↗