PubMed Health⌕ Search

Biomedical subjects

Kazushi Marukawa

Publications and source records attributed to Kazushi Marukawa.

7 recordsLinked to original sources

The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurements.

The purpose of this study is, using a 16-section multidetector-row helical computed tomography (MDCT) scanner with retrospective reconstruction, to compare variability in repeated coronary calcium scoring and qualitative scores of the motion artifacts. One hundred forty-four patients underwent two subsequent scans using MDCT. According to Agatston and volume algorithms, the coronary calcium scores during mid-diastole (the center corresponding to 70% of the R-R cycle) were calculated and the inter-scan variability was obtained. Motion artifacts from coronary artery calcium were subjectively evaluated and classified using a 5-point scale: 1, excellent; no motion artifacts; 2, fine, minor motion artifacts; 3, moderate, mild motion artifacts; 4, bad, severe motion artifacts; 5, poor, doubling or discontinuity. Each reading was done by vessels (left main, left descending, left circumflex and right coronary arteries) and the motion artifact score (mean of the scales) was determined per patient. The variability in the low (1.2+/-0.2) and high (2.4+/-0.6) motion artifact score groups was 7+/-6 (median, 6)% and 19+/-15 (16)% on the Agatston score (P<0.01) and 7+/-7 (6)% and 16+/-13 (14)% on the volume score (P<0.01), respectively. In conclusion, motion has a significant impact on the reproducibility of coronary calcium scoring.

Adult↗

Variability of repeated coronary artery calcium measurements on low-dose ECG-gated 16-MDCT.

OBJECTIVE: High reproducibility on coronary artery calcium (CAC) scoring is a key requirement in monitoring the progression of coronary atherosclerosis. Retrospective ECG-gated helical CT has been shown to be superior to prospective gating helical CT in the reproducibility of CAC measurements. However, it brings with it a high level of radiation exposure. The purpose of this study was to compare low- and standard-dose protocols in the variability of CAC scores and in image quality, thereby assessing the feasibility of low-dose retrospective ECG-gated helical CT in CAC measurements. SUBJECTS AND METHODS: Eighty-six patients with CAC were scanned using a tube current setting of 100 mA once and then a tube current setting equivalent to the patient's body weight twice. CAC scores (Agatston and volume) and interscan variability were evaluated. The mean and SD of the CT attenuation values in regions of interest in the aorta were measured, and the value (mean + 2 x SD) was obtained. RESULTS: A high correlation of log(10) (Agatston score + 1) was observed between sequential helical CT scans (r = 0.998). The variability in CAC measurements ranged from 11% to 12% for both the Agatston and volume scores. With the tube current equivalent to body weight, the value (mean + 2 x SD) did not exceed a CT attenuation value of 130 H. CONCLUSION: Low-dose retrospective ECG-gated helical CT-yielding low variability and achieving the level of image quality needed to measure CAC-can be used to monitor patients with coronary atherosclerosis.

Adult↗

Laparoscopic nephron-sparing surgery: preoperative assessment with three-dimensional computed tomography.

OBJECTIVE: For retroperitoneal laparoscopic nephron-sparing surgery using a microwave tissue coagulator, it is helpful to know the relationship between the tumour, collecting system and vessels to prevent urinary leakage and vascular damage. We assessed the efficacy of multiplanar reformation and three-dimensional (3D) CT with the renal collecting system filled with contrast medium. METHODS: Fifteen patients with small renal tumours of less than 3 cm in diameter underwent dynamic CT examination ten minutes after injection of contrast medium of 30 ml. Multiplanar reformation, volume-rendered and maximum intensity projection images were created for determining operative approaches and for planning the operation. RESULTS: In all cases, the distance between the tumour and collecting system was measured on the multiplanar reformation. Accordingly, five cases were indicated for retroperitoneal laparoscopic nephron-sparing surgery using a microwave tissue coagulator. The remaining ten cases, due to the short distance (less than 10mm), were not considered good candidates for this procedure. The relationship between the tumour, collecting system and vessels was well shown on the volume-rendered and maximum intensity projection images. CONCLUSIONS: Multiplanar reformation and 3D-CT are able to give us an understanding of the surrounding structures. They are helpful in defining the indications for retroperitoneal laparoscopic nephron-sparing surgery using a microwave tissue coagulator and preoperative planning of nephron-sparing surgery.

Aged↗

Variability of repeated coronary artery calcium measurements by 16-MDCT with retrospective reconstruction.

OBJECTIVE: High reproducibility on coronary calcium scoring is an important factor in monitoring the progression of coronary atherosclerosis. The purposes of this study were, using a 16-MDCT scanner with retrospective reconstruction, to compare the effects of thin-slice images and overlapping image reconstruction on the reproducibility of coronary calcium scoring and to compare 16-MDCT with electron beam CT (EBCT). MATERIALS AND METHODS: Fifty patients underwent two sequential examinations using both EBCT and MDCT. For MDCT, images were reconstructed from the same raw data using the following thicknesses and increments (thickness/increment): 1.25 mm/1.25 mm, 2.5 mm/2.5 mm, and 2.5 mm/1.25 mm. The Agatston, volume, and mass scores were calculated on four pairs of image sets. Statistical analysis was performed to determine significant differences in interscan variability among image acquisition protocols and among measurement algorithms. RESULTS: Overlapping reconstructed images (thickness/increment, 2.5 mm/1.25 mm) obtained on a 16-MDCT scanner showed the lowest variability (mean, 13%; median, 10%) when compared with the Agatston score. CONCLUSION: The use of 16-MDCT with overlapping reconstruction by retrospective reconstruction, yielding low variability of coronary artery calcium measurement on two sequential scans, has an advantage over EBCT in monitoring the progression of atherosclerosis.

Aged↗

Coronary artery calcium scoring using 16-MDCT and a retrospective ECG-gating reconstruction algorithm.

OBJECTIVE: Our aim was to compare detection, quantification, and cardiovascular risk stratification of coronary artery calcium (CAC) between electron beam CT and 16-MDCT with retrospective reconstruction. SUBJECTS AND METHODS. One hundred patients underwent both electron beam CT and 16-MDCT, and coronary artery calcium score, volume, and mass were obtained. RESULTS: Correlation between the two CT scanners was high for both calcium score (r(2) = 0.955), volume (r(2) = 0.952), and mass (r(2) = 0.977). Although electron beam CT is viewed as the gold standard, the sensitivity and specificity in the detection of CAC using 16-MDCT with a threshold of 130 H were 98.7% and 100%, respectively. The variability of calcium scores between the two CT scanners (26.5%) was comparable with two electron beam CT scanners reported previously. The variability of calcium volume (20.7%) and mass (20.3%) was lower than that of the score (Student's t test, r = 0.05, 0.01). In clinical cardiovascular risk stratification based on two CT calcium scores, the Cohen's kappa value was 0.929. There was no significant difference between the two scanners using Wilcoxon's signed rank test (p = 0.157). CONCLUSION: The 16-MDCT scanner with retrospective reconstruction, showing high agreement for detection and quantification of CAC with electron beam CT, holds promise in the detection of coronary artery atherosclerosis.

Algorithms↗

Use of multidetector row CT with volume renderings in right lobe living liver transplantation.

Multidetector row CT is a feasible diagnostic tool in pre- and postoperative liver partial transplantation. We can assess vascular anatomy and liver parenchyma as well as volumetry, which provide useful information for both donor selection and surgical planning. Disorders of the vascular and biliary systems are carefully observed in recipients. In addition, we evaluate liver regeneration of both the donor and the recipient by serial volumetry. We present how multidetector row CT with state-of-the-art three-dimensional volume renderings may be used in right lobe liver transplantation.

Blood Volume↗

Three-dimensional navigator for retroperitoneal laparoscopic nephrectomy using multidetector row computerized tomography.

PURPOSE: We evaluated the efficacy of a 3-dimensional (D) navigator for retroperitoneal laparoscopic nephrectomy. MATERIALS AND METHODS: A total of 21 patients with malignant localized renal (16) or ureteral (5) neoplasms underwent multi-detector row computerized tomography. The 3-D navigator was created using volume rendering technique. These findings were compared with videos obtained during laparoscopy. RESULTS: The 3-D navigator depicted all renal arteries (100% sensitivity) and 24 of the 25 renal veins (96% sensitivity). Hilar anatomy, including the tumor, major vessels and adrenal gland, and their relationships were visualized as in laparoscopic views. CONCLUSIONS: The 3-D navigator has a potentially important role in retroperitoneal laparoscopic nephrectomy. It is able to guide surgeons and aid in avoiding operative risks and possible complications.

Adult↗