PubMed Health⌕ Search

Biomedical subjects

Kazuto Yamashita

Publications and source records attributed to Kazuto Yamashita.

10 recordsLinked to original sources

Evaluation of total intravenous anesthesia with propofol or ketamine-medetomidine-propofol combination in horses.

Objective-To compare the anesthetic and cardiorespiratory effects of total IV anesthesia with propofol (P-TIVA) or a ketamine-medetomidine-propofol combination (KMP-TIVA) in horses. Design-Randomized experimental trial. Animals-12 horses. Procedure-Horses received medetomidine (0.005 mg/kg [0.002 mg/lb], IV). Anesthesia was induced with midazolam (0.04 mg/kg [0.018 mg/lb], IV) and ketamine (2.5 mg/kg [1.14 mg/lb], IV). All horses received a loading dose of propofol (0.5 mg/kg [0.23 mg/lb], IV), and 6 horses underwent P-TIVA (propofol infusion). Six horses underwent KMP-TIVA (ketamine [1 mg/kg/h {0.45 mg/lb/h}] and medetomidine [0.00125 mg/kg/h {0.0006 mg/lb/h}] infusion; the rate of propofol infusion was adjusted to maintain anesthesia). Arterial blood pressure and heart rate were monitored. Qualities of anesthetic induction, transition to TIVA, and maintenance of and recovery from anesthesia were evaluated. Results-Administration of KMP IV provided satisfactory anesthesia in horses. Compared with the P-TIVA group, the propofol infusion rate was significantly less in horses undergoing KMP-TIVA (0.14 +/- 0.02 mg/kg/min [0.064 +/- 0.009 mg/lb/min] vs 0.22 +/- 0.03 mg/kg/min [0.1 +/- 0.014 mg/lb/min]). In the KMP-TIVA and P-TIVA groups, anesthesia time was 115 +/- 17 minutes and 112 +/- 11 minutes, respectively, and heart rate and arterial blood pressure were maintained within acceptable limits. There was no significant difference in time to standing after cessation of anesthesia between groups. Recovery from KMP-TIVA and P-TIVA was considered good and satisfactory, respectively. Conclusions and Clinical Relevance-In horses, KMP-TIVA and P-TIVA provided clinically useful anesthesia; the ketamine-medetomidine infusion provided a sparing effect on propofol requirement for maintaining anesthesia.

Anesthesia, Intravenous↗

Experimental study on stability of a high-porosity expanded polytetrafluoroethylene graft in dogs.

PURPOSE: The purpose of the present study was to evaluate the stability of a high-porosity expanded polytetrafluoroethylene (ePTFE) graft, which has been shown to possess excellent biocompatibility and tissue integration. METHODS: The graft used in the present study was a high-porosity ePTFE graft , which had an average internodal distance of approximately 60 microm and a random node architecture with tortuous path channels extending from the outer to the inner surface. Eleven beagle dogs (each group n = 3 or 4) weighing 10-12 kg were used. The graft, with a 6 mm inside diameter and a 30-40 mm length, was implanted into the canine abdominal aorta and retrieved after 2-80 weeks. The deformation of the graft was evaluated by conventional computed tomography (CT). The radial tensile strength, longitudinal tensile strength, and suture retention strength of the graft were measured after 2-80 weeks. RESULTS: CT studies showed no anastomotic aneurysm or deformation of the graft. Physical tests demonstrated no significant deterioration in suture retention strength, radial tensile strength or longitudinal tensile strength for periods ranging from 2-80 weeks compared to pre-implantation grafts. CONCLUSION: The graft possesses adequate stability that ensures safe and effective clinical use.

Animals↗

Anesthetic and cardiovascular effects of balanced anesthesia using constant rate infusion of midazolam-ketamine-medetomidine with inhalation of oxygen-sevoflurane (MKM-OS anesthesia) in horses.

The anesthetic sparring and cardiovascular effects produced by midazolam 0.8 mg/ml-ketamine 40 mg/ml-medetomidine 0.05 mg/ml (0.025 ml/kg/hr) drug infusion during sevoflurane in oxygen (MKM-OS) anesthesia was determined in healthy horses. The anesthetic sparring effects of MKM-OS were assessed in 6 healthy thoroughbred horses in which the right carotid artery was surgically relocated to a subcutaneous position. All horses were intubated and ventilated with oxygen using intermittent positive pressure ventilation (IPPV). The end-tidal concentration of sevoflurane (ET(SEV)) required to maintain surgical anesthesia was approximately 1.7%. Heart rate and mean arterial blood pressure averaged 23-41 beats/min and 70-112 mmHg, respectively. All horses stood between 23-44 min after the cessation of all anesthetic drugs. The cardiovascular effects of MKM-OS anesthesia were evaluated in 5 healthy thoroughbred horses ventilated using IPPV. Anesthesia was maintained for 4 hr at an ET(SEV) of 1.7%. Each horse was studied during left lateral (LR) and dorsal recumbency (DR) with a minimum interval between evaluations of 1 month. Cardiac output and cardiac index were maintained between 70-80% of baseline values during LR and 65-70% of baseline values during DR. Stroke volume was maintained between 75-85% of baseline values during LR and 60-70% of baseline values during DR. Systemic vascular resistance was not different from baseline values regardless of position. MKM-OS anesthesia may be useful for prolonged equine surgery because of its minimal cardiovascular depression in both of lateral and dorsal recumbency.

Anesthesia, Inhalation↗

Axial correction of pes varus by transverse-opening wedge osteotomy and T-plate fixation with beta-tricalcium phosphate (beta-TCP) transplantation in dachshunds.

Axial correction was performed surgically in two miniature dachshunds presenting with lateral patellar dislocation and limping caused by pes varus. Pes varus had resulted from asymmetric closure of the physis of the distal tibia. Prior to surgery, osteotomy was simulated by measuring X-ray films to determine the distance required for the wedge opening. Transverse-opening wedge osteotomy was performed on the medial side of the distal tibia, and beta-tricalcium phosphate (beta-TCP) was inserted in a wedge shape into the area created by the cuneiform osteotomy. Finally, the tibia was fixed by a veterinary 1.5/2.0-mm T-plate. Both dogs were able to walk a few days after surgery, and the lateral dislocation of the patella normalized almost completely in about one month. At two months, X-ray films showed that the implant had remained in position without any dislocation, and the beta-TCP had fused with the surrounding bone.

Animals↗

Electroretinography using contact lens electrode with built-in light source in dogs.

Electroretinography (ERG) is an effective method for the diagnosis of retinal disease. In the dog, dependable ERG recording is difficult without the use of an expensive device like a Ganzfeld full-field stimulator. The International Society for Clinical Electrophysiology of Vision has defined the standard flash stimulus condition (SF) and evaluation of the retina using the b/a ratio in humans. In dogs, evaluation using the b/a ratio has not been reported, whereas the intensity of SF has been defined. In this study, we performed a convenient ERG recording method using a contact lens electrode with a built-in light source (LED-electrode), and confirmed SF as reported previously. ERG recordings were performed on 15 healthy beagle dogs under sedation. We performed bilateral ERG at 12 different intensities after 30 min dark adaptation. After 10 min light adaptation, we recorded single flash cone and flicker cone response using the SF determined in this study. In this study, SF of 3.0 cd/m(2)/sec (6,000 cd/m(2), 0.5 msec) resulted in b/a=2. The intensity for rod response that recorded only the b-wave was 0.0096 cd/m(2)/sec (80 cd/m(2), 0.12 msec). We could achieve ERG for each response easily and smoothly under sedation, and without general anesthesia. Using an LED-electrode, we could perform more quantitative and reproducible ERG examinations than with traditional methods. We propose that the b/a ratio is the most useful parameter in ERG reporting for evaluating retinal function.

Animals↗

Fixation to the canine bone of artificial implant with new surface structure.

Screw and laser (SL) column by making screw threads and forming small holes using laser irradiation on the base metal and conventional beads coating (BC) columns were embedded into the shaft of canine femurs, and compared the implant fixation to the host bone. The interfacial strength in SL columns was almost equivalent as BC columns, and bone-column contact rate was higher than BC columns significantly at twelve weeks after implantation. The newly devised SL surface had almost equivalent bone fixation strength comparable to the conventional BC surface. Also, this surface should provide a useful porous surface for use in artificial joints since there is no risk of surface structure detachment.

Animals↗

The interfacial strength in sputtering-hydroxyapatite-coating implants with arc-deposited surface.

Titanium columns (Ti-6A1-4V) were treated with arc-deposition to roughen the surface enough to anchor the bone, and then coated with hydroxyapatite (HA) at a thickness of 5 micro m by the sputtering technique. Columns were implanted into dog femurs, and fixation of columns to bone due to bone-ingrowth was assessed histologically and with the push-out test. The HA-coated columns were inserted in the shafts of the right femurs of 2 dogs. As a control, columns that were only arc-deposited (non-coated columns) were inserted into the left femurs. The interfacial strength was higher for the HA-coated columns than for the non-coated columns. Coating a rough surface with an HA layer using a sputtering technique reinforces interfacial strength between bone and implants.

Animals↗

Clinical comparison of xylazine and medetomidine for premedication of horses.

OBJECTIVE: To compare the analgesic and cardiopulmonary effects of medetomidine and xylazine when used for premedication of horses undergoing general anesthesia. DESIGN: Randomized clinical trial. ANIMALS: 40 horses. PROCEDURE: Twenty horses were premedicated with medetomidine (10 microg/kg [4.5 microg/lb], i.m.) and the other 20 were premedicated with xylazine (2 mg/kg [0.9 mg/kg], i.m.). Horses were then anesthetized with a combination of guaifenesin and ketamine; anesthesia was maintained with halothane. Additional doses of medetomidine or xylazine were given if horses were not sufficiently sedated at the time of anesthetic induction. After induction of anesthesia, sodium pentothal was administered as necessary to prevent limb movements. Hypotension was treated with dobutamine; hypoventilation and hypoxemia were treated with intermittent positive-pressure ventilation. The quality of anesthetic induction, maintenance, and recovery and the quality of the transition to inhalation anesthesia were scored. RESULTS: Scores for the quality of the transition to inhalation anesthesia were significantly higher for horses premedicated with medetomidine than for horses premedicated with xylazine. However, other scores, recovery times, and numbers of attempts needed to achieve sternal recumbency and to stand were not significantly different between groups. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that medetomidine is suitable for premedication of horses undergoing general anesthesia. Analgesic and cardiopulmonary effects of medetomidine were similar to those of xylazine, except that the transition to inhalation anesthesia was smoother when horses were premedicated with medetomidine, rather than xylazine.

Adrenergic alpha-Agonists↗

Infusion of guaifenesin, ketamine, and medetomidine in combination with inhalation of sevoflurane versus inhalation of sevoflurane alone for anesthesia of horses.

OBJECTIVE: To evaluate effects of infusion of guaifenesin, ketamine, and medetomidine in combination with inhalation of sevoflurane versus inhalation of sevoflurane alone for anesthesia of horses. DESIGN: Randomized clinical trial. ANIMALS: 40 horses. PROCEDURE: Horses were premedicated with xylazine and anesthetized with diazepam and ketamine. Anesthesia was maintained by infusion of guaifenesin, ketamine, and medetomidine and inhalation of sevoflurane (20 horses) or by inhalation of sevoflurane (20 horses). A surgical plane of anesthesia was maintained by controlling the inhaled concentration of sevoflurane. Sodium pentothal was administered as necessary to prevent movement in response to surgical stimulation. Hypotension was treated with dobutamine; hypoxemia and hypercarbia were treated with intermittent positive-pressure ventilation. The quality of anesthetic induction, maintenance, and recovery and the quality of the transition to inhalation anesthesia were scored. RESULTS: The delivered concentration of sevoflurane (ie, the vaporizer dial setting) was significantly lower and the quality of transition to inhalation anesthesia and of anesthetic maintenance were significantly better in horses that received the guaifenesin-ketamine-medetomidine infusion than in horses that did not. Five horses, all of which received sevoflurane alone, required administration of pentothal. Recovery time and quality of recovery were not significantly different between groups, but horses that received the guaifenesin-ketamine-medetomidine infusion required fewer attempts to stand. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that in horses, the combination of a guaifenesin-ketamine-medetomidine infusion and inhalation of sevoflurane resulted in better transition and maintenance phases while improving cardiovascular function and reducing the number of attempts needed to stand after the completion of anesthesia, compared with inhalation of sevoflurane.

Anesthesia↗

Detection of cone dysfunction induced by digoxin in dogs by multicolor electroretinography.

It is difficult to detect discrete cone function with the present conventional electroretinography (ERG) examination. In this study, we developed contact electrodes with a built-in color (red (644 nm), green (525 nm), or blue (470 nm)) light source (color LED-electrode), and evaluated an experimental model of digoxin in the dog. First, 17 normal Beagle dogs were used to determine which electrode works well for color ERG measurement on dogs. Then, color ERG was performed on seven normal Beagle dogs at various points during a 14-day period of digoxin administration. A single daily dose of 0.0125 mg/kg/day, which is within the recommended oral maintenance dosage range for dogs, was administered orally for 2 weeks. Ophthalmic examination, measurement of plasma concentration of digoxin, and color ERG examination were performed. On first examination, amplitudes of all responses were significantly (P < 0.01) lower with the red, than with the blue and green electrodes during ERG recording. In ERG using the red electrode, the standard deviation was large. According to these preliminary results, the red electrode was not used in the experimental dog model with digoxin. In the digoxin administrated animals, no significant change was observed in the ophthalmic examination findings. The digoxin level increased steadily throughout the dosing period but was always within the therapeutic range for dogs. In rod ERG, no abnormalities were detected with any electrode. In standard combined ERG, decreased amplitude of the a-wave was detected with every electrode. In single flash cone ERG, prolongation of implicit time was detected by color ERG with the blue and green electrodes. In 30-Hz flicker ERG, decreased amplitude was detected only by color ERG with the blue electrode. The decreased amplitude and prolonged implicit time recovered after termination of digoxin administration. Cone dysfunction induced by digoxin in the dog was revealed by multicolor ERG using blue and green LED-electrodes. Multi-color ERG was useful for detecting cone type-specific dysfunction in the dog.

Administration, Oral↗