PubMed Health⌕ Search

Biomedical subjects

Kazuyoshi Suga

Publications and source records attributed to Kazuyoshi Suga.

At least 19 recordsLinked to original sources

Computed tomography-diagnosed emphysema, not airway obstruction, is associated with the prognostic outcome of early-stage lung cancer.

PURPOSE: Because both emphysema and lung cancer can arise from biological damage caused by cigarette smoking, we investigated if the development of emphysema is associated with the clinical features of smoker's lung cancer. EXPERIMENTAL DESIGN: The subjects were a consecutive series of 100 smokers who underwent lobectomy with hilar and mediastinal dissection for clinical stage I non-small cell lung cancer. We studied the relationship between the presence or absence of emphysema at the onset of the lung cancer and clinicopathologic features. Emphysema was diagnosed by measuring the low-attenuation area using computed tomography densitometry. RESULTS: There were no differences in clinicopathologic variables, including the degree of smoking exposure between the patients with (n=58) and those without (n=42) emphysema, although male gender and airflow limitation were predominant in the patients with emphysema. The presence of emphysema, but neither male gender nor airflow limitation, adversely affected both overall and disease-specific survival. According to Cox regression analysis, emphysema was an independent prognosticator among age, gender, degree of smoking exposure, tumor size, nodal status, histologic subtype, histologic grade, and microvessel invasion. These results were stabilized by a bootstrap sampling model. CONCLUSIONS: Computed tomography-diagnosed emphysema, but not airway obstruction, is associated with poor prognosis in smokers with early-stage lung cancer. Thus, routine computed tomography densitometry in smokers with lung cancer should be mandatory.

Aged↗

Physiological rehabilitation after video-assisted lung lobectomy for cancer: a prospective study of measuring daily exercise and oxygenation capacity.

OBJECTIVE: Video-assisted thoracic surgery followed by fast-track rehabilitation has been claimed to accelerate physiological recovery after lung lobectomy for cancer; however, we are still uncertain when the exercise and oxygenation capacity recover and how to determine the rehabilitation time required by each patient. The aim of this study was to evaluate the rehabilitation time after this type of surgery and determine the best predictors of rehabilitation time. METHODS: We measured exercise and oxygenation capacity daily during the perioperative period on a prospective series of 40 patients who had scheduled to undergo video-assisted lung lobectomy for cancer. Postoperative rehabilitation was confirmed when patients had regained more than 80% of their baseline exercise capacity and more than 98% of their baseline oxygenation capacity without the use of routine tubes for oxygen supplementation, fluid transfusion, bladder catheterization, chest drainage, and epidural catheterization. The hypoxemia index, which we found to have correlated with early-postoperative oxygenation capacity, was calculated preoperatively using baseline arterial oxygen saturations and the severity of emphysema on computed tomography. RESULTS: The median rehabilitation time was 3 days. Stepwise Cox regression analysis revealed that the postoperative predicted forced expiratory volume in 1s (relative ratio 1.043, p < 0.01) and the hypoxemia index (relative ratio 1.343, p = 0.02) were the best independent determinants of the postoperative rehabilitation time. CONCLUSIONS: By conducting daily physiological assessments, we identified the rehabilitation time and its determinants in patients who underwent video-assisted lung lobectomy for cancer. Our results are valuable for planning patient-specific fast-track surgery in the hospital setting.

Aged↗

[Development of a new method of high-speed rotation multiplied projection single photon emission computed tomography of the triple-headed type: lung MAA SPECT based on phantom study].

PURPOSE: A chest phantom study was conducted to evaluate the image quality of newly developed high-speed rotation multiplied projection-single photon emission computed tomography (HSRMP-SPECT) images. MATERIALS AND METHODS: HSRMP-SPECT images of a chest phantom consisting of a simulated lung structure filled with 5000 ml of water containing 185 MBq Tc-99m-pertechnetate, and several small 11 mm simulated lung nodules of glass balls and one large 35 mm simulated lung nodule of a plastic sphere filled with water were obtained using a triple-headed SPECT system. During image acquisition, this phantom was regularly moving in the head-to-caudal direction with a range of 12 mm at a frequency of 15 cycles/min to simulate respiratory motion, and 360 degrees projection data of this moving phantom was acquired with an image acquisition time of 20 sec, which was repeated 10 times. To eliminate the setting time between projection and acquisition of multiple temporal samples of data, each detector was continuously rotated in the clockwise direction for 20 sec around a 120-degree arc. On the perspective SPECT images reconstructed from various numbers of the 20-sec projection data, the perfusion heterogeneity of the simulated lungs and perfusion defect clarity of the simulated nodules were assessed by the coefficient of variation (CV) of pixel counts and the defect-to-lung radioactivity ratios, respectively. The results were compared with those on conventional SPECT images of the moving phantom obtained with a data acquisition time of 8 min, and SPECT images of the standing phantom obtained with the same data acquisition time. RESULTS: The average CV value of 0.28+/-0.01 on the SPECT image reconstructed from 5 projection data sets was not significantly different from that of 0.27+/-0.01 on the SPECT image reconstructed from 10 projection data sets (p<0.05). The perfusion defect contrast of the simulated nodules obtained from 5 projection data was significantly higher than that on conventional SPECT images (0.50 vs. 0.73) . CONCLUSIONS: The present phantom study indicated that HSRMP-SPECT could be a useful technique for quickly obtaining high-quality SPECT images of a moving subject, thereby improving perfusion defect clarity in comparison with the conventional technique. This technique may have potential utility for obtaining high-quality breath-hold SPECT images of the chest in clinical practice.

Image Processing, Computer-Assisted↗

[Examination of three-detector high-speed-rotation SPECT acquisition under breathhold in body: clinical application of 99mTc-MAA].

In traditional pulmonary perfusion single photon emission computed tomography (SPECT), respiratory lung motion and cyclically varying changes in lung volume during image acquisition inherently degrade the image sharpness of ill-defined perfusion defects. However, because of the lack of an adequate fast imaging technique, perfusion SPECT has never been acquired under breathhold conditions, whereas breathhold images are commonly used for pulmonary magnetic resonance (MR) and computed tomographic (CT) images. Although a high-speed imaging technique combined with a multidetector SPECT system may enable SPECT images to be obtained during a short period of breathholding, image quality would be degraded owing to decreased radioactivity counts and increased statistical noise. To resolve this problem, we developed an innovative SPECT imaging technique using a triple-head SPECT system and the high-speed-detector rotation-multiplied projection (HSRMP) technique, where a single SPECT image was reconstructed from multiple respiratory dimensional breathhold projection data obtained at the same angle. HSRMP provided noiseless high-quality perfusion SPECT images by compensating for decreased radioactivity counts caused by high-speed imaging, and significantly improved image quality and perfusion defect clarity compared with traditional non-breathhold SPECT images.

Female↗

Cerebral air embolism during imaging of a sentinel lymphatic drainage in the respiratory tract.

We report a rare but notable case of cerebral air embolism complicating transthoracic intrapulmonary injection of an imaging agent used to locate sentinel lymph nodes. After a bolus injection of 2 mL of iopamidol into the peritumoral area with a 23-gauge needle, the patient complained of complete paralysis on his left side. Intraaortic gas was detected by computed tomography immediately after the injection. The patient recovered spontaneously without any additional complication. Surgeons should be aware of this rare but possible complication during sentinel lymph node assessment.

Aged↗

Breath-hold single-photon emission tomography and computed tomography for predicting residual pulmonary function in patients with lung cancer.

OBJECTIVE: We sought to evaluate the utility of integrated breath-hold single-photon emission tomography and computed tomography imaging compared with that of simple calculation with the lung segment-counting technique for predicting residual pulmonary function in patients undergoing surgical intervention for lung cancer. METHODS: A prospective series of 22 patients undergoing anatomic lung resection for cancer were enrolled in this study. Postoperative residual forced expiratory volume in 1 second was predicted by measuring the radioactivity counts of the affected lobes or segments to be resected within the entire lungs by placement of regions of interest on single-photon emission tomography and computed tomography images. Residual forced expiratory volume in 1 second was also estimated by using the segment-counting technique. RESULTS: Both predicted values agreed well with postoperative forced expiratory volume in 1 second. Although the residual forced expiratory volume in 1 second predicted by means of single-photon emission tomography and computed tomography correlated well with that predicted by using segment counting, the values were significantly underestimated by the segment-counting technique in 4 outliers with severe emphysema. There were 2 patients with borderline pulmonary functional reserve whose residual forced expiratory volume in 1 second values were predicted more accurately by means of single-photon emission tomography and computed tomography than by using segment counting. CONCLUSION: Integrated breath-hold single-photon emission tomography and computed tomography images allow the accurate prediction of postoperative pulmonary function but without statistical superiority over the simple segment-counting technique. Further study of the usefulness of single-photon emission tomography and computed tomography in patients with severe emphysema and borderline lung function should prove valuable because the segment-counting technique underestimates pulmonary functional reserve in these patients.

Aged↗

CT lymphography-navigated sentinel lymph node biopsy in patients with superficial esophageal cancer.

BACKGROUND: To evaluate experimentally and clinically the feasibility of a newly developed technique of endoscopic computed tomography (CT) lymphography with endoscopic submucosal injection of iopamidol for esophageal sentinel lymph node (SLN) mapping and biopsy examination. METHODS: Nine anesthetized dogs underwent CT after endoscopic submucosal injection of 2 mL iopamidol; 1.25-mm thick CT images were obtained before and at 1, 3, 5, 7, and 10 minutes after contrast injection. Clinically, 12 patients with superficial esophageal cancer (preoperative imaging stage: cT1, cN0) underwent CT lymphography in a similar fashion at 1, 5, and 10 minutes after peritumoral injection, followed by radical esophagectomy and regional lymph node dissection under CT lymphography guidance. RESULTS: CT lymphography visualized the draining lymphatic vessels and SLNs within 5 minutes after contrast injection. All 14 SLNs in dogs (average, 1.5 nodes per animal; range, 1-2) and 28 SLNs in patients (average, 2.3 nodes per patient; range, 1-4) were found intraoperatively at the correct location under CT lymphography guidance. Lymph node metastasis could be detected with excellent sensitivity and accuracy in this small number of patients with no false-negative findings; metastasis was positive only in the preoperatively identified SLNs in 4 patients and in both SLNs and distant nodes in 1 patient, and was negative in all resected nodes in the remaining 7 patients. CONCLUSIONS: Endoscopic CT lymphography appears to allow accurate identification of direction and locations of lymph flow and SLNs, and has the potential clinical applicability for esophageal SLN mapping and biopsy examination, but will require a large study to determine its accuracy and usefulness.

Aged↗

Characterization of 133Xe gas washout in pulmonary emphysema with dynamic 133Xe SPECT functional images.

PURPOSE: To characterize regional ventilation impairment of pulmonary emphysema using dynamic 133Xe single photon emission computed tomography (SPECT) functional images, compared with other forms of chronic obstructive pulmonary disease (COPD). METHODS: Dynamic 133Xe SPECT was performed in 34 patients with emphysema and 15 patients with other forms of COPD. Three-dimensional voxel-based functional images of the half-clearance time (T1/2) mainly reflecting the initial rapid washout of 133Xe gas from the large airways, and of the mean transit time (MTT) reflecting 133Xe gas washout from the entire lungs, including the small airways and alveoli, were created based on an area-over-height method. T1/2 and MTT values were compared with the regional extent of low attenuation areas (%LAA) on density-mask computed tomography images and the diffusing capacity of the lungs for carbon monoxide (DLCO). RESULTS: The MTT/T1/2 ratio in each lung in emphysema was significantly higher than that in other forms of COPD (1.60+/-0.74 vs. 1.21+/-0.26; P<0.01). In the selected unilateral lungs with similar T1/2 values, MTT values were also significantly higher in emphysema. MTT values in each lung showed a significantly closer correlation with the corresponding %LAA values compared with T1/2 values in emphysema (R=0.698, P<0.0001 vs. R=0.338, P<0.01; P<0.05); while only the T1/2 values showed a significant correlation in other forms of COPD (P<0.0001). In correlation with DLCO, MTT values showed a significantly closer correlation compared with T1/2 values in emphysema (R=0.909, P<0.0001 vs. R=0.555, P<0.001; P<0.05); while either value did not show a significant correlation in other forms of COPD. CONCLUSION: MTT values are more critically affected in emphysema compared with other forms of COPD without significant alveolar destruction, and MTT and T1/2 values appear to be differently correlated with the regional extent of LAA between these two disorders. Direct comparison of regional T1/2 and MTT values on functional images may contribute to the demarcation of lung pathology of these two disorders.

Administration, Inhalation↗

Nonlinear motion correction of respiratory-gated lung SPECT images.

We propose a method for correcting the motion of the lungs between different phase images obtained by respiratory-gated single photon emission computed tomography (SPECT). This method is applied to SPECT images that show a preserved activity distribution in the lungs such as 99m-Tc macro aggregated albumin (99m-Tc-MAA) perfusion images and 99m-Tc-Technegas ventilation images. In the proposed method, an objective function, which consists of both the degree of similarity between a reference image and a deformed image, and the smoothness of deformation is defined and optimized using a simulated annealing algorithm. For the degree of similarity term in the objective function, an expansion ratio, defined as the ratio of change in local volume due to deformation, is introduced to preserve the total activity during the motion correction process. This method was applied to data simulated from computer phantoms, data acquired from a physical phantom, and 17 sets of clinical data. In all cases, the motion correction between inspiration and expiration phase images was successfully achieved.

Algorithms↗

Quantitative computed tomography versus spirometry in predicting air leak duration after major lung resection for cancer.

BACKGROUND: Emphysema is a well-known risk factor for developing air leak or persistent air leak after pulmonary resection. Although quantitative computed tomography (CT) and spirometry are used to diagnose emphysema, it remains controversial whether these tests are predictive of the duration of postoperative air leak. METHODS: Sixty-two consecutive patients who were scheduled to undergo major lung resection for cancer were enrolled in this prospective study to define the best predictor of postoperative air leak duration. Preoperative factors analyzed included spirometric variables and area of emphysema (proportion of the low-attenuation area) that was quantified in a three-dimensional CT lung model. Chest tubes were removed the day after disappearance of the air leak, regardless of pleural drainage. Univariate and multivariate proportional hazards analyses were used to determine the influence of preoperative factors on chest tube time (air leak duration). RESULTS: By univariate analysis, site of resection (upper, lower), forced expiratory volume in 1 second, predicted postoperative forced expiratory volume in 1 second, and area of emphysema (< 1%, 1% to 10%, > 10%) were significant predictors of air leak duration. By multivariate analysis, site of resection and area of emphysema were the best independent determinants of air leak duration. The results were similar for patients with a smoking history (n = 40), but neither forced expiratory volume in 1 second nor predicted postoperative forced expiratory volume in 1 second were predictive of air leak duration. CONCLUSIONS: Quantitative CT is superior to spirometry in predicting air leak duration after major lung resection for cancer. Quantitative CT may aid in the identification of patients, particularly among those with a smoking history, requiring additional preventive procedures against air leak.

Aged↗

Initial application of respiratory-gated 201Tl SPECT in pulmonary malignant tumours.

AIM: Respiratory-gated thallium-201 chloride (201Tl) single photon emission computed tomography (SPECT) was used in preliminary investigations to reduce the adverse respiratory motion effects observed on standard ungated SPECT images and to obtain reliable fusion images with computed tomography (CT) in patients with malignant lung tumours. METHODS: Fifteen patients with primary lung cancer (n=10) or metastatic lung tumours (n=5) underwent gated SPECT 20 min after intravenous injection of 148 MBq 201Tl, using triple-headed SPECT and laser light respiratory tracking units. Projection data were acquired by a step and shoot mode, with 20 stops over 120 degrees for each detector and a preset time of 30 s for each 6 degrees stop. Gated end-inspiratory and ungated images were obtained from 1/8 data centred at peak inspiration for each regular respiratory cycle and for the full respiratory cycle data, respectively. The degree and size of tumour 201Tl uptake were compared between these images by regions of interest (ROI) analysis. Gated SPECT images were registered with rest inspiratory CT images using an automated three-dimensional (3D) image registration tool. Registration mismatch was assessed by measuring the 3D distance of the centroid of 14 201Tl-avid peripheral tumours. Attenuation correction of gated SPECT images was performed using CT attenuation values of these fusion images. RESULTS: Gated SPECT images improved image clarity and contrast of tumour 201Tl uptakes compared with ungated images, regardless of the decreased count density due to the use of gated images. The lesion-to-normal (L/N) lung count ratios and ROI size in 18 well-circumscribed 201Tl-avid tumours were significantly higher and smaller on gated images (both P<0.0001). Gated images showed positive 201Tl uptakes in two small peripheral tumours, although negative on ungated images, and demarcated 201Tl-avid tumours from adjacent 201Tl-avid lymph node or surrounding focal 201Tl uptakes caused by other pathology, although these were not clearly demarcated on ungated images. On fusion images, gated images yielded a significantly better SPECT-CT matching compared with ungated images (P<0.0001). Fusion images accurately localized 201Tl uptakes of tumour/lymph node and other focal pathological/physiological conditions. Attenuation-corrected gated SPECT images further facilitated the detection of 201Tl uptake in small or deeply located lesions, with significantly increased L/N ratios. CONCLUSION: Gated SPECT images facilitate the detection of tumour 201Tl uptake and provide reliable SPECT-CT fusion images, which contribute to accurate interpretation and attenuation correction of Tl SPECT images.

Adult↗

Preferential location of acute pulmonary thromboembolism induced consolidative opacities: assessment with respiratory gated perfusion SPECT-CT fusion images.

PURPOSE: Preferential location of acute pulmonary thromboembolism (PTE) induced consolidative opacities (infarction/atelectasis) was determined on respiratory gated perfusion SPECT-CT fusion images. METHOD: Gated end-inspiratory perfusion SPECT images were obtained in 21 patients with acute PTE and 17 patients with inflammatory diseases, using a triple-headed SPECT system and a respiratory tracking device. Anatomical relationships of consolidative opacities and perfusion defects were assessed on gated SPECT-rest inspiratory CT fusion images. The size and radioactivity of perfusion defects with acute PTE consolidative opacities were compared with those of defects without these opacities. The contribution of fusion images for differential diagnosis of acute PTE induced and inflammatory disease induced lesions was evaluated by receiver operating characteristic (ROC) curve analysis. RESULTS: Of the total 56 acute PTE induced consolidative opacities, 42 (75%) were located at the peripheral interface between the severely decreased and adjacent relatively preserved perfusion areas within wedge shaped perfusion defects on fusion images. These defects with consolidative opacities were significantly larger and had taken up less radioactivity compared with those in the 86 defects without these lesions (P<0.0001). In contrast, of the 29 inflammatory disease induced opacities, 14 (48.2%) had the matched defects and 13 (44.8%) were located at the proximal portion of defects. These preferential locations of acute PTE induced and inflammation induced lesions were significantly different (P<0.01). In ROC curves, the combined reading of fusion images showed a significantly higher differential diagnostic accuracy compared with the reading of CT and SPECT images alone (P<0.01). CONCLUSIONS: Acute PTE induced consolidative opacities preferentially occur at the peripheral lung interface between severely decreased and adjacent relatively preserved perfusion areas within relatively large and severely decreased perfusion defects. The fusion images, which provide an accurate assessment of the morphological-perfusion defect relationship could, potentially, provide a differential diagnosis between acute PTE induced and inflammatory disease induced lesions.

Acute Disease↗

Enhanced perfusion defect clarity and inhomogeneity in smokers' lungs with deep-inspiratory breath-hold perfusion SPECT images.

PURPOSE: Deep-inspiratory breath-hold (DIBrH) Tc-99m-macroaggregated albumin (MAA) SPECT images were developed to accurately evaluate perfusion impairment in smokers' lungs. METHODS: DIBrH SPECT was performed in 28 smokers with or without low attenuation areas (LAA) on CT images, using a triple-headed SPECT system and a laser light respiratory tracking device. DIBrH SPECT images were reconstructed from every 4 degrees projection of five adequate 360 degrees projection data sets with almost the same respiratory dimension at 20 sec DIBrH. Perfusion defect clarity was assessed by the lesion (defect)-to-contralateral normal lung count ratios (L/N ratios). Perfusion inhomogeneity was assessed by the coefficient of variation (CV) values of pixel counts and correlated with the diffusing capacity of the lungs for carbon monoxide/alveolar volume (DLCO/VA) ratios. The results were compared with those on conventional images. RESULTS: Five DIBrH projection data sets with minimal dimension differences of 2.9+/-0.6 mm were obtained in all subjects. DIBrH images enhanced perfusion defects compared with conventional images, with significantly higher L/N ratios (P<0.0001), and detected a total of 109 (26.9%) additional detects (513 vs. 404), with excellent inter-observer agreement (kappa value of 0.816). CV values in the smokers' lungs on DIBrH images were also significantly higher compared with those on conventional images (0.31+/-0.10 vs. 0.19+/-0.06, P<0.0001). CV values in smokers on DIBrH images showed a significantly closer correlation with DLCO/VA ratios compared with conventional images (R = 0.872, P<0.0001 vs. R=0.499, P<0.01). CONCLUSION: By reducing adverse effect of respiratory motion, DIBrH SPECT images enhance perfusion defect clarity and inhomogeneity, and provide more accurate assessment of impaired perfusion in smokers' lungs compared with conventional images.

Artifacts↗

Breast sentinel lymph node navigation with three-dimensional interstitial multidetector-row computed tomographic lymphography.

OBJECTIVE: Three-dimensional multidetector-row computed tomographic lymphography (3D MDCT-LG) with interstitial injection of a widely available nonionic monometric contrast medium iopamidol was used for navigation of breast sentinel lymph node (SLN) biopsy. METHODS: 3D MDCT-LG was obtained after massage of the interstitially injection sites of a total of 4-5 mL undiluted iopamidol at periareolar and peritumoral areas in 68 consecutive patients with early-stage breast cancer, using a 4 detector-row CT scanner. Drainage lymphatic patterns and SLN anatomy were assessed on 3D MDCT-LG images. 3D MDCT-LG-navigated SLN biopsy with combined use of blue dye was followed by backup axillary lymph node dissection to evaluate accuracy of SLN biopsy. RESULTS: The 3D MDCT-LG images clearly localized primary SLNs by visualizing the direct connection between these nodes and their afferent lymphatic vessels on detailed anatomy of the surrounding structures in all patients. Drainage lymphatic pathways on these images were classified into 4 patterns: single route/single SLN (39 cases, 57%), multiple routes/multiple SLNs (10 cases, 15%), single route/multiple SLNs (9 cases, 13%), and multiple routes/single SLN (10 cases, 15%). Under 3D MDCT-LG navigation, SLNs was found at the accurate location in all patients. With backup axillary lymph node dissection, metastasis was found in 14 (20%) patients, and 8 of these patients had metastasis only in the preoperatively identified SLNs. In other 5 positive patients, metastasis was found both in the SLN and non-SLNs. However, micrometastasis eventually was found only in non-SLN in an elderly patient. Overall, the sensitivity, false-negative rate, and accuracy of 3D CT-L-navigated SLN biopsy were 92% (13/14 patients), 7% (1/14 patients), and 98% (67/68 patients), respectively. CONCLUSIONS: Topographic 3D interstitial MDCT-LG can be a widely available and reliable navigator for breast SLN biopsy.

Adult↗

Lymphatic drainage from esophagogastric tract: feasibility of endoscopic CT lymphography for direct visualization of pathways.

PURPOSE: To evaluate the feasibility of an endoscopic computed tomographic (CT) lymphography technique with submucosal injection of iopamidol for direct visualization of lymphatic drainage pathways in dogs and in patients with operable esophageal cancer. MATERIALS AND METHODS: With institutional animal committee approval, a total of 2 mL of undiluted iopamidol was injected into the esophageal (n = 6) or gastric (n = 3) submucosa in nine dogs by using a flexible endoscope. Multi-detector row CT images (section thickness, 1.25 mm) were obtained before contrast material injection and during the 10 minutes after injection. The animals were euthanized so that their lymphatic anatomy could be examined. With ethical committee approval and patient informed consent, nine patients with esophageal cancer also underwent CT lymphography with peritumoral injection of 2 mL of iopamidol, followed by esophagectomy and regional lymph node dissection with CT lymphographic guidance. The histopathologic features of dissected nodes, including sentinel lymph nodes (SLNs), were examined. RESULTS: CT lymphography depicted the direct connection of lymphatic drainage vessels with enhanced and/or unenhanced nodes (ie, SLNs) as early as within 5 minutes after contrast material injection in all subjects. All 13 SLNs in dogs (1.4 nodes per animal) and 18 SLNs in patients (two nodes per patient) were found and dissected at the correct location by using CT lymphographic guidance. In patients, histopathologic examination revealed the high predictive value of CT lymphographic-guided SLN biopsy: Only one of the preoperatively identified SLNs in three patients and both SLNs and adjacent nodes in two patients were positive for metastasis; all resected nodes in the remaining four patients were negative. CONCLUSION: Endoscopic CT lymphography is a feasible method for visualizing the direct connection between and the accurate anatomic location of SLNs and lymphatic drainage vessels.

Aged↗

Role of quantitative CT in predicting hypoxemia and complications after lung lobectomy for cancer, with special reference to area of emphysema.

STUDY OBJECTIVES: To determine the ability of quantitative CT, with special reference to area of emphysema, to predict early postoperative oxygenation capacity and outcome after lung lobectomy for cancer. METHODS: Sixty-two consecutive patients scheduled to undergo lung lobectomy for cancer were enrolled in this study. The area of emphysema (< - 910 Hounsfield units) was measured on a three-dimensional CT lung model. Arterial oxygen saturation (Sao(2)) was calculated from Pao(2) measured 1 day before and 1 day after surgery with patients at rest breathing room air. A patient was considered to have recovered at the completion of a standardized management regimen. RESULTS: Postoperative Sao(2) (postSao(2)) was predicted by the baseline value and the area of emphysema with the use of a regression equation. Ten of the 62 patients (16%) had postoperative cardiopulmonary complications (CPCs). The median time to postoperative recovery was 3 days (range, 1 to 17 days). Predicted postSao(2) and predicted postoperative FEV(1) were shown to be significant independent predictors of postoperative CPCs as well as postoperative recovery time. CONCLUSION: Determining the area of emphysema by quantitative CT is useful in predicting early postoperative oxygenation capacity. Predicted oxygenation capacity and predicted ventilatory capacity independently affect perioperative outcomes. Therefore, using quantitative CT in combination with spirometry may improve risk prediction in patients undergoing lung lobectomy for cancer. However, the role of quantitative CT in grading nonemphysematous lung diseases, such as interstitial lung diseases, must be investigated.

Aged↗

Clinical utility of co-registered respiratory-gated( 99m)Tc-Technegas/MAA SPECT-CT images in the assessment of regional lung functional impairment in patients with lung cancer.

PURPOSE: The aim of the study was to provide preliminary validation of the utility of co-registered respiratory-gated ventilation/perfusion single-photon emission computed tomography-computed tomography (SPECT-CT) images in the assessment of regional lung functional impairment in patients with lung cancer. METHODS: Twenty untreated and three radiotherapy-treated patients with lung cancer underwent gated( 99m)Tc-Technegas/macroaggregated albumin (MAA) SPECT, using a triple-headed SPECT unit and a respiratory synchroniser. Gated SPECT images were obtained from 1/8 data centered at peak inspiration for each regular respiratory cycle and co-registered with tidal inspiration CT images using an automated three-dimensional registration tool. RESULTS: Gated SPECT images detected 10.2% more ventilation defects (205 vs 186) and 9% more perfusion defects (218 vs 200) compared with ungated images, with a significantly higher lesion-to-normal lung contrast ( P<0.0001). Co-registered gated SPECT-CT images accurately visualised the anatomy of ventilation and/or perfusion defects associated with bronchial and/or vascular involvement by tumours, resulting in changes in surgical planning in two patients with lung cancer. In the three patients who had received radiotherapy, perfusion defects along the radiation field were identified even in the lung areas without abnormal opacities on CT images. In the operated patients, the co-registered gated SPECT-CT images allowed accurate placement of regions of interest over the lung lobes to be resected, yielding a significantly better prediction of postoperative forced expired volume in 1 s (FEV(1)) compared with that predicted without use of these images ( R=0.993 vs R=0.890; P<0.05), with an excellent inter-observer reproducibility. CONCLUSION: Detailed functional-morphological correlation on co-registered gated SPECT-CT images contributes to accurate assessment of regional functional impairment, and may be useful for surgical planning, prediction of postoperative function and assessment of external beam radiotherapy effects in patients with lung cancer.

Administration, Inhalation↗

Assessment of regional lung function impairment in airway obstruction and pulmonary embolic dogs with combined noncontrast electrocardiogram-gated perfusion and gadolinium diethylenetriaminepentaacetic acid aerosol magnetic resonance images.

PURPOSE: To define regional function impairment in airway obstruction (AO) and pulmonary embolic (PE) dogs with a combination study of noncontrast electrocardiogram (ECG)-gated perfusion and gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) aerosol magnetic resonance (MR) images. METHODS: After acquisition of multiphase fast-spin-echo (FSE) MR images during cardiac cycles in 14 AO dogs and 19 PE dogs, ECG-gated perfusion-weighted (PW) images were obtained by subtraction between two-phase images of the minimum lung signal intensity (SI) during systole and maximum SI during diastole. Each dog subsequently inhaled Gd-DTPA aerosol for 20 minutes, and subtracted Gd-DTPA aerosol images were obtained from precontrast and maximally enhanced images. ECG-gated PW images were compared with intravenous Gd-DTPA-enhanced pulmonary arterial perfusion phase (PAPP) images. RESULTS: ECG-gated PW images were consistent with Gd-DTPA-enhanced PAPP images in all dogs, with significant correlations in the affected-to-unaffected lung perfusion ratios (P < 0.005). Gd-DTPA aerosol images showed sufficient and uniform enhancement in the unaffected lungs. In all the AO areas, these combined images showed the matched perfusion and aerosol deposition defects. These images showed perfusion defects without aerosol deposition defects in the relatively small embolized areas, but showed the matched defects in the widely embolized areas probably due to hypoxic bronchial constriction. CONCLUSION: The combination MR studies may be acceptable for noninvasively defining regionally impaired lung function in AO and PE.

Administration, Inhalation↗