PubMed Health⌕ Search

Biomedical subjects

Kazuyoshi Takayama

Publications and source records attributed to Kazuyoshi Takayama.

17 recordsLinked to original sources

Shock wave induced cytoskeletal and morphological deformations in a human renal carcinoma cell line.

Effects of shock waves on the morphology and cytoskeleton of a human renal carcinoma cell line (ACHN) were investigated in vitro. ACHN monolayer cultured on a cover slide glass was treated with 10 shots of focused underwater shock waves, with 16 MPa peak pressure at the focal area of a piezoceramic shock wave generator. After exposure to the shock wave, based on the severity of morphological deformations of the treated cells, the monolayer was divided into three morphological areas; focal, marginal and intact. Morphological deformations were found to be associated with disorganization of the intracellular cytoskeletal filaments. Deformation of the cytoskeletal proteins in the treated cells were separately studied with respect to the location of the cells within the three morphological areas. Among three major cytoskeletal proteins, actin and tubulin, but not vimentin, were affected by the shock waves. The deformed cells reorganized their cytoskeletal network within 3 h with a pattern similar to the control, indicating the transient characteristic of the shock wave induced cytoskeletal damage in the surviving cells. The remaining cell fragments on the slide glass, which contained short actin filaments, indicated the important role of shear stress in damaging the cytoskeletal fibers by shock waves.

Actins↗

[Intraoperative brain surface blood flow monitoring using IRIS V thermographic imaging system in patients with Moyamoya disease].

Surgical revascularization for moyamoya disease prevents cerebral ischemic attacks by improving CBF. But little is known about the changes of intraoperative cerebral hemodynamics and its effect on postoperative neurological status including symptomatic cerebral hyperperfusion. To address this issue, we applied a novel infrared camera system (IRIS-V thermographic system) for real-time, visual monitoring of surface CBF during surgery in patients with moyamoya disease. Seven patients (8 sides, male:female= 3:4, 7-62 years old) with moyamoya disease were included in the study. After STA-MCA anastomosis, STA were occluded transiently and recanalized, and whole sequence was recorded by IRIS-V system. Correlation between clinical, radiological findings and infrared imaging were investigated. Patency of bypass was confirmed by this camera during surgery in all cases. The intraoperative imaging patterns were divided into two groups. Group A: Change of brain surface color (++) (3 cases). Group B: Change of brain surface color (-) (4 cases). Transient symptomatic hyperperfusion occurred in all patients in Group A, whereas all patients in Group B showed non-symptomatic transient focal hyperperfusion on SPECT. No patient suffered permanent neurological deterioration compared to preoperative status. Characteristic pattern of the intraoperative cerebral hemodynamics as delineated by IRIS-V could be the optimal predictor for postoperative transient symptomatic hyperperfusion after direct bypass in patients with moyamoya disease.

Adult↗

Bead-like passage of chloride ions through ClC chloride channels.

The ClC chloride channels control the ionic composition of the cytoplasm and the volume of cells, and regulate electrical excitability. Recently, it has been proposed that prokaryotic ClC channels are H+-Cl- exchange transporter. Although X-ray and molecular dynamics (MD) studies of bacterial ClC channels have investigated the filter open-close and ion permeation mechanism of channels, details have remained unclear. We performed MD simulations of ClC channels involving H+, Na+, K+, or H3O+ in the intracellular region to elucidate the open-close mechanism, and to clarify the role of H+ ion an H+-Cl- exchange transporter. Our simulations revealed that H+ and Na+ caused channel opening and the passage of Cl- ions. Na+ induced a bead-like string of Cl- -Na+-Cl--Na+-Cl- ions to form and permeate through ClC channels to the intracellular side with the widening of the channel pathway.

Bacterial Proteins↗

Submicrosecond temperature measurement in liquid water with laser-induced thermal acoustics.

Using laser-induced thermal acoustics, we demonstrate nonintrusive and remote sound-speed and temperature measurements in liquid water. Unsteady thermal gradients in the water sample produce fast, random laser beam misalignments, which are the primary source of uncertainty in these measurements. For water temperatures over the range 10 degrees C to 45 degrees C, the precision of a single 300-ns-duration measurement varies from +/-1 to +/-16.5 m/s for sound speed and from +/-0.3 degrees C to +/-9.5 degrees C for temperature. Averaging over 10 s (100 laser pulses) yields accuracies of +/-0.64 m/s and +/-0.45 degrees C for sound speed and temperature, respectively.

Journal Article↗

Compact monochromatic flash x-ray generator utilizing a disk-cathode molybdenum tube.

The high-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -50 to -70 kV by a power supply, and the electric charges in the condensers are discharged to an x-ray tube after closing gap switches in the surge generator with a trigger device. The x-ray tube is a demountable diode, and the turbo molecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Clean molybdenum Kalpha lines are produced using a 20 microm-thick zirconium filter, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. At a charging voltage of -70 kV, the instantaneous tube voltage and current were 120 kV and 1.0 kA, respectively. The x-ray pulse widths were approximately 70 ns, and the generator produced instantaneous number of Kalpha photons was approximately 3 x 10(7) photons/cm2 per pulse at 0.5 m from the source of 3.0 mm in diameter.

Animals↗

A proposed parent vessel geometry-based categorization of saccular intracranial aneurysms: computational flow dynamics analysis of the risk factors for lesion rupture.

OBJECT: The authors created a simple, broadly applicable classification of saccular intracranial aneurysms into three categories: sidewall (SW), sidewall with branching vessel (SWBV), and endwall (EW) according to the angiographically documented patterns of their parent arteries. Using computational flow dynamics analysis (CFDA) of simple models representing the three aneurysm categories, the authors analyzed geometry-related risk factors such as neck width, parent artery curvature, and angulation of the branching vessels. METHODS: The authors performed CFDAs of 68 aneurysmal geometric formations documented on angiograms that had been obtained in patients with 45 ruptured and 23 unruptured lesions. In successfully studied CFDA cases, the wall shear stress, blood velocity, and pressure maps were examined and correlated with aneurysm rupture points. Statistical analysis of the cases involving aneurysm rupture revealed a statistically significant correlation between aneurysm depth and both neck size (p < 0.0001) and caliber of draining arteries (p < 0.0001). Wider-necked aneurysms or those with wider-caliber draining vessels were found to be high-flow lesions that tended to rupture at larger sizes. Smaller-necked aneurysms or those with smaller-caliber draining vessels were found to be low-flow lesions that tended to rupture at smaller sizes. The incidence of ruptured aneurysms with an aspect ratio (depth/neck) exceeding 1.6 was 100% in the SW and SWBV categories, whereas the incidence was only 28.75% for the EW aneurysms. CONCLUSIONS: The application of standardized categories enables the comparison of results for various aneurysms' geometric formations, thus assisting in their management. The proposed classification system may provide a promising means of understanding the natural history of saccular intracranial aneurysms.

Aged↗

Ca2+ binding sites in calmodulin and troponin C alter interhelical angle movements.

Molecular dynamics analyses were performed to examine conformational changes in the C-domain of calmodulin and the N-domain of troponin C induced by binding of Ca(2+) ions. Analyses of conformational changes in calmodulin and troponin C indicated that the shortening of the distance between Ca(2+) ions and Ca(2+) binding sites of helices caused widening of the distance between Ca(2+) binding sites of helices on opposite sides, while the hydrophobic side chains in the center of helices hardly moved due to their steric hindrance. This conformational change acts as the clothespin mechanism.

Animals↗

Experimental application of pulsed Ho:YAG laser-induced liquid jet as a novel rigid neuroendoscopic dissection device.

BACKGROUND AND OBJECTIVES: Although water jet technology has been considered as a feasible neuroendoscopic dissection methodology because of its ability to perform selective tissue dissection without thermal damage, problems associated with continuous use of water and the ensuing fountain-effect-with catapulting of the tissue-could make water jets unsuitable for endoscopic use, in terms of safety and ease of handling. Therefore, the authors experimented with minimization of water usage during the application of a pulsed holmium:yttrium-aluminum-garnet (Ho:YAG) laser-induced liquid jet (LILJ), while assuring the dissection quality and the controllability of a conventional water jet dissection device. We have developed the LILJ generator for use as a rigid neuroendoscope, discerned its mechanical behavior, and evaluated its dissection ability using the cadaveric rabbit ventricular wall. STUDY DESIGN/MATERIALS AND METHODS: The LILJ generator is incorporated into the tip of a stainless steel tube (length: 22 cm; internal diameter: 1.0 mm; external diameter: 1.4 mm), so that the device can be inserted into a commercial, rigid neuroendoscope. Briefly, the LILJ is generated by irradiating an internally supplied water column within the stainless steel tube using the pulsed Ho:YAG laser (wave length: 2.1 microm, pulse duration time: 350 microseconds) and is then ejected through the metal nozzle (internal diameter: 100 microm). The Ho:YAG laser pulse energy is conveyed through optical quartz fiber (core diameter: 400 microm), while cold water (5 degrees C) is internally supplied at a rate of 40 ml/hour. The relationship between laser energy (range: 40-433 mJ/pulse), standoff distance (defined as the distance between the tip of the optical fiber and the nozzle end; range: 10-30 mm), and the velocity, shape, pressure, and average volume of the ejected jet were analyzed by means of high-speed camera, PVDF needle hydrophone, and digital scale. The quality of the dissection plane, the preservation of blood vessels, and the penetration depth were evaluated using five fresh cadaveric rabbit ventricular walls, under neuroendoscopic vision. RESULTS: Jet velocity (7.0-19.6 m/second) and pressure (0.07-0.28 MPa) could be controlled by varying the laser energy, which determined the penetration depth in the cadaveric rabbit ventricular wall (0.07-1.30 mm/shot). The latter could be cut into desirable shapes-without thermal effects-under clear neuroendoscopic vision. The average volume of a single ejected jet could be confined to 0.42-1.52 microl/shot, and there was no accompanying generation of shock waves. Histological specimens revealed a sharp dissection plane and demonstrated that blood vessels of diameter over 100 microm could be preserved, without thermal damage. CONCLUSIONS: The present pulsed LILJ system holds promise as a safe and reliable dissection device for deployment in a rigid neuroendoscope.

Animals↗

Demonstration of enhanced K-edge angiography using a cerium target x-ray generator.

The cerium target x-ray generator is useful in order to perform enhanced K-edge angiography using a cone beam because K-series characteristic x rays from the cerium target are absorbed effectively by iodine-based contrast mediums. The x-ray generator consists of a main controller, a unit with a Cockcroft-Walton circuit and a fixed anode x-ray tube, and a personal computer. The tube is a glass-enclosed diode with a cerium target and a 0.5-mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively, and the focal-spot sizes were 1.0 x 1.3 mm. Cerium Kalpha lines were left using a barium sulfate filter, and the x-ray intensity was 0.48 microC/kg at 1.0 m from the source with a tube voltage of 60 kV, a current of 0.40 mA, and an exposure time of 1.0 s. Angiography was performed with a computed radiography system using iodine-based microspheres. In coronary angiography of nonliving animals, we observed fine blood vessels of approximately 100 microm with high contrasts.

Angiography↗

Pulsed holmium:yttrium-aluminum-garnet laser-induced liquid jet as a novel dissection device in neuroendoscopic surgery.

OBJECT: A pressure-driven continuous jet of water has been reported to be a feasible tool for neuroendoscopic dissection owing to its superiority at selective tissue dissection in the absence of thermal effects. With respect to a safe, accurate dissection, however, continuous water flow may not be suitable for intraventricular use. The authors performed experiments aimed at solving problems associated with continuous flow by using a pulsed holmium:yttrium-aluminum-garnet (Ho:YAG) laser-induced liquid jet (LILJ). They present this candidate neuroendoscopic LILJ dissection system, having examined its mechanical characteristics and evaluated its controllability both in a tissue phantom and in a rabbit cadaveric ventricle wall. METHODS: The LILJ generator was incorporated into the tip of a No. 4 French catheter so that the LILJ could be delivered via a neuroendoscope. Briefly, the LILJ was generated by irradiating an internally supplied column of physiological saline with a pulsed Ho:YAG laser (pulse duration time 350 microsec; laser energy 250-700 mJ/pulse) within a No. 4 French catheter (internal diameter 1 mm) and ejecting it from a metal nozzle (internal diameter 100 microm). The Ho:YAG laser energy pulses were conveyed by an optical fiber (core diameter 400 microm) at 3 Hz, whereas physiological saline (4 degrees C) was supplied at a rate of 40 ml/hour. The mechanical characteristics of the pulsed LILJ were investigated using high-speed photography and pressure measurements; thermal effects and controllability were analyzed using an artificial tissue model (10% gelatin of 1 mm thickness). Finally, the ventricle wall of a rabbit cadaver was dissected using the LILJ. Jet pressure increased in accordance with laser energy from 0.1 to 2 bar; this translated into a penetration depth of 0.08 to 0.9 mm per shot in the ventricle wall of the rabbit cadaver. The gelatin phantom could be cut into the desired shape without significant thermal effects and in the intended manner, with a good surgical view. CONCLUSIONS: The present results show that the pulsed LILJ has the potential to become a safe and reliable dissecting method for endoscopic procedures.

Animals↗

Computational simulation of therapeutic parent artery occlusion to treat giant vertebrobasilar aneurysm.

We applied computational fluid dynamics (CFD) analysis to assess 3D digital subtraction angiography findings in a patient with a giant vertebrobasilar aneurysm to simulate and compare the consequences of left and right vertebral artery occlusion. The balloon occlusion test suggested that occlusion of the right vertebral artery is the better way to treat this patient's aneurysm from the point of view of aneurysmal thrombosis and isolation from the circulation. The computer simulation supported this conclusion, at the same time indicating that from the point of view of pressure distribution on the wall of the aneurysm, the right vertebral occlusion may be also accompanied by an undesirable effect. A high-pressure area on the aneurysm wall in systole was revealed. This high pressure potentially could lead to subsequent aneurysmal growth, which indeed occurred, as was revealed by a follow-up examination 6 months later. This study is a good example of possible future applications of CFD in patients with cerebrovascular disease before therapeutic intervention.

Aged↗

Monochromatic polycapillary imaging utilizing a computed radiography system.

A fundamental study on quasi-parallel radiography using a polycapillary plate and a copper-target x-ray tube is described. In the experiments, the tube voltage was regulated from 12 to 22 kV, and the tube current was regulated within 3.0 mA by the filament temperature. The exposure time was controlled in order to obtain optimum x-ray intensity, and the maximum focal spot dimensions were approximately 2.0 x 1.5 mm. The thickness and the inner capillary tube diameter of the polycapillary were 1.0 mm and 25 microm, respectively. Monochromatic x-rays were produced using a 10 microm-thick nickel filter with a tube voltage of 17 kV, and these rays were formed into quasi-parallel beams by the polycapillary. The radiogram was taken using a computed radiography system utilizing imaging plates. In the measurement of image resolution, the spatial resolution hardly varied according to increases in the distance between the resolution-test chart and imaging plate using a polycapillary. A 50 microm tungsten wire could be observed, and fine blood vessels of approximately 100 microm were visible in angiography.

Angiography↗

Computational replicas: anatomic reconstructions of cerebral vessels as volume numerical grids at three-dimensional angiography.

BACKGROUND AND PURPOSE: We present a relatively simple approach that physicians can use to reconstruct cerebral vessels as 3D numerical grids or computational replicas. The method accurately duplicates their geometry to provide computer simulations of their blood flow. METHODS: Initial images were obtained by using any medical imaging technique, such as MR angiography, CT angiography, or 3D digital subtraction angiography. The data were collected in DICOM format and converted by a DICOM reader into a 3D gray-scale raster image. The image was then processed by using commercial visualization and mesh generation software, which allowed extraction of the luminal surface of the blood vessel (by using the isosurfacing technique). The subsequent final output was an unstructured tetrahedral grid that can be directly used for detailed analysis of cerebral vascular geometry for patient-specific simulations of blood flow. RESULTS: Four examples of grid reconstruction and blood flow simulation for patients with ruptured aneurysms were validated with angiographic and operative findings. The ruptured areas were correlated with areas of high fluid-induced wall-shear stress. CONCLUSION: This approach promises to be a practical tool for planning treatment and follow-up of patients after neurosurgical or endovascular interventions with 3D angiography. The proposed commercial packages or conceptually similar ones seem to be relatively simple and suitable for direct use by neurosurgeons or neuroradiologists.

Aneurysm, Ruptured↗

Application of shock waves as a treatment modality in the vicinity of the brain and skull.

OBJECT: Shock waves have not previously been used as a treatment modality for lesions in the brain and skull because of the lack of a suitable shock wave source and concerns about safety. Therefore, the authors have performed experiments aimed at developing both a new, compact shock wave generator with a holmium:yttrium-aluminum-garnet (Ho:YAG) laser and a safe method for exposing the surface of the brain to these shock waves. METHODS: Twenty male Sprague-Dawley rats were used in this study. In 10 rats, a single shock wave was delivered directly to the brain, whereas the protective effect of inserting a 0.7-mm-thick expanded polytetrafluoroethylene (ePTFE) dural substitute between the dura mater and skull before applying the shock wave was investigated in the other 10 rats. Visualizations on shadowgraphy along with pressure measurements were obtained to confirm that the shock wave generator was capable of conveying waves in a limited volume without harmful effects to the target. The attenuation rates of shock waves administered through a 0.7-mm-thick ePTFE dural substitute and a surgical cottonoid were measured to determine which of these materials was suitable for avoiding propagation of the shock wave beyond the target. CONCLUSIONS: Using the shock wave generator with the Ho:YAG laser, a localized shock wave (with a maximum overpressure of 50 bar) can be generated from a small device (external diameter 15 mm, weight 20 g). The placement of a 0.7-mm-thick ePTFE dural substitute over the dura mater reduces the overpressure of the shock wave by 96% and eliminates damage to surrounding tissue in the rat brain. These findings indicate possibilities for applying shock waves in various neurosurgical treatments such as cranioplasty, local drug delivery, embolysis, and pain management.

Animals↗

Irradiation of intense characteristic x-rays from weakly ionized linear molybdenum plasma.

In the plasma flash x-ray generator, a high-voltage main condenser of approximately 200 nF is charged up to 55 kV by a power supply, and electric charges in the condenser are discharged to an x-ray tube after triggering the cathode electrode. The flash x-rays are then produced. The x-ray tube is a demountable triode that is connected to a turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to a rod molybdenum target of 2.0 mm in diameter by the electric field in the x-ray tube, weakly ionized linear plasma, which consists of molybdenum ions and electrons, forms by target evaporation. At a charging voltage of 55 kV, the maximum tube voltage was almost equal to the charging voltage of the main condenser, and the peak current was about 20 kA. When the charging voltage was increased, the linear plasma formed, and the K-series characteristic x-ray intensities increased. The K lines were quite sharp and intense, and hardly any bremsstrahlung rays were detected. The x-ray pulse widths were approximately 700 ns, and the time-integrated x-ray intensity had a value of approximately 35 micro C/kg at 1.0 m from the x-ray source with a charging voltage of 50 kV.

Electrodes↗

Holmium: YAG laser-induced liquid jet knife: possible novel method for dissection.

BACKGROUND AND OBJECTIVES: Making surgical incisions in vessel-rich organs without causing bleeding is difficult. Thus, it is necessary to develop new devices for this purpose, especially for surgery involving small vessels as in neurosurgery, where damage against even small cerebral vessels result in severe neurological deficits. STUDY DESIGN/MATERIALS AND METHODS: A laser-induced liquid jet was generated by irradiating pulsed Holmium Yttrium-Aluminum-Garnet (Ho: YAG) laser (beams of 350 microseconds pulse width) within a copper tube (internal diameter, 1 mm) with pure water (150 ml /hour). Ho: YAG laser beams were irradiated through an optical fiber (core diameter, 0.4 mm). The influence of the input of laser energy, structure of the nozzle, and the stand-off distance between the optical fiber tip and nozzle exit on the jet velocity was measured by a high-speed video camera to evaluate controllability of jet. The effect on artificial organs made of 10 and 30%(w/v) gelatin, each of which represent features of soft tissue and blood vessels. RESULTS: Jet velocity increased in proportion to gain in laser energy input, and maximum penetration depth into 10%(w/v) gelatin was 35 mm by single exposure at 350 mJ/pulse without impairing a vessel model. Shapes of nozzle also modified jet velocity with optimal nozzle/tube area ratio of 0.25. CONCLUSIONS: The laser-induced liquid jet has excellent potential as a new tool for removing soft tissue without damaging vital structures.

Dissection↗

Hemodynamic analysis of an adult vein of Galen aneurysm malformation by use of 3D image-based computational fluid dynamics.

We applied computational fluid dynamic (CFD) analysis on the numerical grid of a 3D rotational digital subtraction angiogram obtained in a 22-year-old male patient, with an accidentally discovered vein of Galen malformation associated with single feeder aneurysm, to understand the flow pattern through the two aneurysms and improve our general understanding of hemodynamic characteristics of this variety of fusiform aneurysm. This technical note provides a good example of the application of CFD to 3D digital subtraction angiography for studying the flow pattern in patients with cerebrovascular disease.

Adult↗