PubMed Health⌕ Search

Biomedical subjects

Keat G Ong

Publications and source records attributed to Keat G Ong.

2 recordsLinked to original sources

A rapid highly-sensitive endotoxin detection system.

This paper presents a rapid, highly-sensitive, and low-cost method of endotoxin quantification based on the use of stress-responsive magnetoelastic sensors, that monitor the gel formation (viscosity change) of the Limulus Amoebocyte Lysate (LAL) assay in response to endotoxin. Ribbon-like magnetoelastic sensors, 12.7 mm x 6 mm x 28 microm, were immersed in a LAL assay after mixing with test samples of variable endotoxin concentration, and the decrease in resonance amplitude of the sensor was recorded as a function of time. Experimental results show excellent correlation between endotoxin concentration and the maximum clot rate, determined by taking the minimum point of the first derivative of the amplitude-time curve, as well as the clotting-time, defined as the time that corresponds to the maximum clot rate. Using a LAL gel-clot assay with a sensitivity of 0.06 EU/ml (EU: endotoxin unit), the magnetoelastic sensor based technology can detect the presence of endotoxin at 0.0105 EU/ml in test requiring approximately 20 min. Unlike optical methods used for determining endotoxin concentration, the color of the test solution does not impact the magnetoelastic sensor measurement. Due to the small size of the sensor reader electronics and low cost, the magnetoelastic sensor based endotoxin detection system is ideally suited for wide-spread use in endotoxin screening for sepsis prevention.

Biosensing Techniques↗

Tracking the harmonic response of magnetically-soft sensors for wireless temperature, stress, and corrosive monitoring.

This paper describes the application of magnetically-soft ribbon-like sensors for measurement of temperature and stress, as well as corrosive monitoring, based upon changes in the amplitudes of the higher-order harmonics generated by the sensors in response to a magnetic interrogation signal. The sensors operate independently of mass loading, and so can be placed or rigidly embedded inside nonmetallic, opaque structures such as concrete or plastic. The passive harmonic-based sensor is remotely monitored through a single coplanar interrogation and detection coil. Effects due to the relative location of the sensor are eliminated by tracking harmonic amplitude ratios, thereby, enabling wide area monitoring. The wireless, passive, mass loading independent nature of the described sensor platform makes it ideally suited for long-term structural monitoring applications, such as measurement of temperature and stress inside concrete structures. A theoretical model is presented to explain the origin and behavior of the higher-order harmonics in response to temperature and stress.

Corrosion↗